SETTING PARAMETERS
The LCD screen may display the temperature in degrees Celsius or Fahrenheit. To select the preferred display, press on the
Humidity (13) and Timer (12) keys simultaneously.
USE OF THE DEHUMIDIFIER
A. DEHUMIDIFIER FUNCTION
The principle of the dehumidifier involves the suction of humid air from
the room. This air is then filtered and directed to a condenser at a lower
temperature (the compressor acts on a coolant gas which lowers the
temperature of the condenser), which transforms the water vapour in the
air into water, which is then collected in a tank. The «dried» air is returned
to the room. The most comfortable relative humidity for human beings is
between 45 % and 55 %.
The dehumidifier can operate in manual or automatic mode.
Use in manual mode
• In manual mode, you may select between low (19) or high (18).
• To select the level of the dehumidifier, press on the Power key (10) and then on the Mode key(11) until the desired icon
appears.
Use in automatic mode
• In automatic mode, you may set the desired degree of humidity. This can vary between 40 % and 70 %.
• To select the degree of humidity, press on the Power key (10) and then on the Mode key(11) until the desired icon
appears.
• You must then press the Humidity key (13) to select the degree of humidity. The selected degree will flash for a few
seconds. When operating, the appliance will indicate the degree of humidity and the temperature of the room.
• The appliance will then automatically maintain or create the selected degree of humidity.
Automatic anti-freeze
• The appliance is equipped with an automatic anti-freeze system. If the temperature of the room is less than 5°, the
dehumidifier program cannot run.
• The dehumidifier is also equipped with a second temperature sensor located near to the condenser. The role of this
sensor is to measure the temperature of the air in this area and prevent freezing, which could affect the normal
operation of the appliance. This temperature is checked every 38 minutes. If the temperature detected is less than -5°C,
the compressor will stop and the anti-freeze program will automatically start. After the anti-freeze program, the fan
function will run for 5 minutes. After this period of time, if the temperature is less than 1°C, the appliance will trigger
ventilation for a further 3 minutes. When the temperature exceeds 1°C, the dehumidifier will restart.
• The following table indicates mean water quantities extracted over a 24-hour period based on a range of temperatures
and levels of humidity* for informative purposes:
Temperature Degree of humidity
60% 80%
22° 7,2L 13,5L
26° 9L 16,2L
*These figures are mean values and may vary depending on where the appliance is used