VOLTCRAFT DL-111K Owner's manual

Category
Measuring & layout tools
Type
Owner's manual
14
TABLE OF CONTENTS
Page
1. Introduction 15
2. Intended Use 16
3. Delivery Content 16
4. Symbol explanation 16
5. Safety instructions 17
6. Operating elements 18
7. Software installation 18
8. Programming the data logger 19
9. Starting the measurement 21
10. Displaying data logger readout 22
11. Inserting/replacing the battery 23
12. Installing wall holder 23
13. Maintenance and cleaning 24
14. Disposal 24
15. Technical data 25
15
INTRODUCTION1.
Dear Customer,
In purchasing this Voltcraft® product, you have made a very good decision for which we would like
to thank you.
Voltcraft® - In the eld of measuring, charging and network technology, this name stands for
high-quality products which perform superbly and which are created by experts whose concern is
continuous innovation.
From the ambitious hobby electronics enthusiast to the professional user, products from the Voltcraft®
brand family provide the optimum solution even for the most demanding tasks. And the remarkable
feature is: we offer you the mature technology and reliable quality of our Voltcraft® products at
an almost unbeatable price-performance ratio. In this way, we aim to establish a long, fruitful and
successful co-operation with our customers.
We wish you a great deal of enjoyment with your new Voltcraft® product!
All names of companies and products are trademarks of the respective owner. All rights
reserved.
16
INTENDED USE2.
This product is designed to measure temperature via a type K temperature sensor. The measurement
range is from -200 to +1370 ºC (-328 to 2498 ºF). The measured temperature readings are saved
on the data logger and can be analysed using the software included. The internal memory can store
31,808 readings. In addition, alarm values can be set that trigger a visual warning signal if they are
exceeded/under-run. The measurements can be started automatically or manually. Power is supplied
via a 3.6 V lithium type 1/2 AA battery. The product is only to be used indoors in dry conditions.
This product fulls European and national requirements related to electromagnetic compatibility
(EMC). CE conformity has been veried and the relevant statements and documents have been
deposited at the manufacturer.
Unauthorisedconversionand/ormodicationofthedeviceareinadmissiblebecauseofsafetyand
approval reasons (CE). Any usage other than described above is not permitted and can damage the
productandleadtoassociatedriskssuchasshort-circuit,re,electricshock,etc.Pleasereadthe
operating instructions thoroughly and keep them for further reference.
Observe all safety instructions and information within this operating manual.
DELIVERY CONTENT3.
Data logger• Wall holder•
Type K temperature sensor• 2 screws•
CD-ROM• 2 dowels•
3.6 V Lithium battery type 1/2 AA• Operating instructions•
SYMBOL EXPLANATION4.
An exclamation mark in a triangle indicates important instructions in this operating
manual which absolutely have to be observed.
The symbol can be found when you are to be given tips and information on operation.
17
SAFETY INSTRUCTIONS5.
We do not assume liability for resulting damages to property or personal injury if
the product has been abused in any way or damaged by improper use or failure
to observe these operating instructions. The warranty/ guarantee will then expire!
The icon with exclamation mark indicates important information in the operating
instructions. Carefully read the whole operating instructions before operating the
device, otherwise there is risk of danger.
Dear Customer, the following safety instructions are intended not only for the protection of your health
but also for the protection of the device. Please read carefully through the following points:
Persons / Product
The product is not a toy and should be kept out of reach of children and pets!•
On commercial premises, the accident prevention regulations of the Association of Industrial •
Professional Associations with respect to electrical systems and operating equipment must be
observed.
In schools, training centres, Hobby and DIY workshops, the handling of measuring appliances •
must be responsibly supervised by trained personnel.
When used in conjunction with other devices, observe the operating instructions and safety notices •
of connected devices.
The product must not be subjected to heavy mechanical stress or intense vibration.•
Theproductmustnotbeexposedtoelectromagneticelds,extremetemperatures,directsunlight•
or dampness.
The device must not be exposed to humidity or liquids.•
The product should not be used immediately after it has been brought from an area of cold •
temperature to an area of warm temperature. Condensed water might destroy the product. Wait
until the product adapts to the new ambient temperature before use.
If there is reason to believe that safe operation is no longer possible, put the device out of operation •
and secure it against unintended operation. Safe operation is no longer possible if:
the product shows visible damages, -
the product no longer works and -
the product was stored under unfavourable conditions for a long period of time, -
the product was subject to considerable transport stress. -
The manufacturer or supplier accepts no responsibility whatsoever for incorrect displays or the •
consequences which can arise from such incorrect displays.
Batteries
Batteries must be kept out of the reach of children.•
When installing the battery, make sure to pay attention to the correct polarity.•
Do not let batteries/rechargeable batteries lie around openly. There is a risk of batteries being •
swallowed by children or pets. If swallowed, consult a doctor immediately.
Leaking or damaged batteries/rechargeable batteries may cause acid burns when coming into •
contact with skin, therefore use suitable protective gloves.
Makesurethatbatteries/storagebatteriesarenotshort-circuitedorthrownintore.Thereisa•
risk of explosion!
18
Never disassemble batteries/storage batteries!•
Do not recharge normal batteries. There is a risk of explosion!•
In case of longer periods of non-use (e.g. during storage) remove the inserted battery/accumulator •
to avoid damage through leaking batteries.
Miscellaneous
The product must not be used for medical or public purposes.•
Repair works must only be carried out by a specialist/ specialist workshop.•
If you have queries about handling the device, that are not answered in this operating •
instruction, our technical support is available under the following address and telephone number:
Voltcraft
®
, 92242 Hirschau, Lindenweg 15, Germany, phone 0180 / 586 582 7.
OPERATING ELEMENTS6.
1 USB plug 4 Green LED (REC)
2 Data logger button 5 Battery compartment cover
3 Red LED (ALM) 6 Temperature sensor socket
SOFTWARE INSTALLATION7.
Place the CD included in the delivery in the corresponding drive of your computer.1.
The installation program starts automatically after inserting the CD. Depending on the system and 2.
itssetup,youmayhoweverhavetostarttheinstallationmanually.Forthispurpose,startthele
“setup.exe” on the CD.
The installation program takes you semi-automatically through the program installation. During 3.
this,youhavetoacceptthelicenseagreementandhavetheoptiontodeneadifferentinstallation
directory than the suggested one. Still leave the CD in the drive after installation. The program icon
is created on the desktop (“Type K Temperature Datalogger”).
19
Connect the datalogger to the computer when it is ready for operation. After a brief moment, the 4.
computer reports a new hardware and starts installing the USB driver.
Follow the instructions of the installation program.5.
After the installation is complete, you can start the program “Type K Temperature Datalogger”.6.
For help or the exact descriptions of each software function, go to the menu “Help – Help Topics”. 7.
You can also click on the yellow question mark icon.
PROGRAMMING THE DATA LOGGER8.
Once you reprogram the data logger and save the settings, all previously saved
data are deleted. Thus, if required, save the readings prior to reprogramming the
data logger. Then proceed as described in the chapter “Data logger readout“.
Connect the data logger to a PC and start the “Type K Temperature Datalogger” program.1.
In the program, the menu item “Instrument – Data Logger Setup” or the small computer icon in the 2.
toolbarisusedtocongurethedatalogger(seechapter“Conguringthedatalogger”).
For help or the exact descriptions of each software function, go to the menu “Help – Help Topics”. 3.
You can also click on the blue question mark icon.
In the blue bar at the top, the setup program displays the connection to the data logger.4.
Connected = Data logger is ready for use -
Not Connected = Data logger is not ready for use or is not connected. -
After you have successfully programmed the data logger, click on “Setup” in order to save the 5.
settings in the data logger. The data logger is now programmed and can be started.
20
Sampling Setup
Sampling Rate Scanning frequency in seconds / minutes / hours
(1 second to 12 hours)
Alarm Setup
Unit Fahrenheit or Celsius
High Alarm Value triggering a warning when exceeded
Low Alarm Value triggering a warning when under-run
LED Flash Cycle Setup
10 s / 20 s / 30 s Flash frequency of the LED in seconds
No Light LEDdoesnotash
Start Method
Manual Manual start of the measuring operation by pressing the data logger
button
Automatic Measurement starts automatically after clicking “Setup”
Delay Time Time delay for automatic start of measurement
(0 seconds to 5 hours)
Default Reset settings
Setup Conrmsettingsforthedatalogger
Cancel Cancel programming operation
21
STARTING THE MEASUREMENT9.
The temperature sensor included in delivery is suitable for a temperature range •
of -50 to +250 ºC. To utilise the full measurement range of the data logger, you
will need a temperature sensor with a more extensive measurement range
(available separately).
Make sure only to use the temperature sensors specied to this effect for your
measurements (in this case: K type). Before connecting lines, check plugs or
sensor tips (“beads”) for good condition and for awless insulation (free of
damage).
Make sure that only the temperature sensors are exposed to the temperatures
to be measured. Make sure to observe the safety provisions and the technical
data as regards the service temperature. The max. input quantities must never
be exceeded.
Never try to press mixed-up connectors (+ and -) forcefully into the bushes.
This would destroy the bushes beyond repair, and they would have to be
replaced.
Do not connect voltages! This might destroy the device.
Hold the temperature sensor line end to/in the de-energized measuring uid
(heat sink, etc., but not in caustic or inammable uids!).
First you must program the data logger (see chapter “Programming the data logger”).1.
If you have selected the “Manual” function, hold down the Data Logger button for two seconds to 2.
start the measurement.
If you have selected the “Automatic” function, the data logger starts the measurement automatically 3.
after you have completed programming the data logger. If you have set a time delay, measurement
will commence after the preset time period.
Duringthemeasurement,thegreenLEDashesatthefrequencysetinthe“LEDFlashCycle4.
Setup”.
To stop the measurement manually, hold down the Data Logger button for two seconds.5.
Once the memory of the data logger is full, the measurement is terminated automatically.6.
The recording can also be terminated at any time by displaying the readout on the computer before 7.
the recording is complete (see chapter “Displaying data logger readout”).
22
LED signals and their meaning
LED Signal Description
Green (REC)
ashes once at the frequency set
under “LED Flash Cycle Setup”.
active measurement, readings do not exceed /
under-run the alarm limit values
ashes twice at the frequency set
under “LED Flash Cycle Setup”.
with time-delayed start of measurement
Red (ALM)
ashestwiceevery30seconds reading under-runs alarm lower-limit value
ashes three times every 30
seconds
reading exceeds alarm upper-limit value
ashesonceevery20seconds weak battery
ashesonceevery2seconds temperature sensor not properly connected
Red + Green ashesonceevery60seconds memory full
--- no LED on logger turned off or batteries empty
DISPLAYING DATA LOGGER READOUT10.
Start the “Type K Temperature Datalogger” program and connect the data logger to the computer.1.
From the menu, select “Instrument – Download Data”. You can also click on the icon with the white 2.
arrow with blue background.
Press“Download”toconrm.Themeasuringcurveofthemeasurementisdisplayed.3.
To save the data, choose “File – Save” from the menu. You can also click on the disc icon.4.
To exit, close the program window.5.
Afteryouarenishedreadingdatafromthedatalogger,alwaysdisconnectitfromthecomputer.6.
Keeping the data logger connected to the USB port of the computer for extended periods
can result in a premature discharge of the battery.
23
INSERTING / REPLACING THE BATTERY11.
With a pointed object (e.g. a small screwdriver or similar), open the casing. Lever the casing off in 1.
the direction of the arrow.
Pull the data logger from the casing.2.
Turn the data logger around and insert the battery into the battery compartment observing the right 3.
polarity. Observe of the polarity markings in the battery compartment.
Slide the data logger back into the casing until it snaps into place. Now the data logger is ready 4.
for programming.
ReplacementofthebatteryisrequiredwhentheredLEDashesevery20seconds.
INSTALLING WALL HOLDER12.
Make sure not to damage any cables or pipes behind the wall when drilling dowel
holes.
Select a level, vertical surface and drill two dowel holes.1.
Insert the dowels and secure the wall bracket in vertical alignment on the surface using the screws. 2.
The mounting holes of the wall bracket must face downwards.
Place the data logger in the wall bracket. The protective cap must point downwards. 3.
24
Alternatively, attach the wall bracket using the double-sided adhesive tape applied to
theback.Todothis,removetheprotectivelmandpressthewallbracketagainstthe
desired surface. The surface must be dry, dust-free and free of grease. The adhesive
tape reaches its full adhesive strength for bonding only at temperatures over 5 °C.
MAINTENANCE AND CLEANING13.
The device is maintenance-free apart from the need to replace the batteries and cleaning it once in
a while. Use a clean, lint-free, antistatic and slightly damp cloth to clean the device. Do not use any
abrasive or chemical agents or detergents containing solvents.
DISPOSAL14.
General
In order to preserve, protect and improve the quality of environment, protect human
health and utilise natural resources prudently and rationally, the user should return
unserviceable product to relevant facilities in accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately and
not as municipal waste.
Batteries / rechargeable batteries
The user is legally obliged (battery regulation) to return used batteries and rechargeable
batteries. Disposing used batteries in the household waste is prohibited! Batteries/
rechargeable batteries containing hazardous substances are marked with the crossed-
out wheeled bin. The symbol indicates that the product is forbidden to be disposed via
the domestic refuse. The chemical symbols for the respective hazardous substances are
Cd = Cadmium, Hg = Mercury, Pb = Lead.
You can return used batteries/ rechargeable batteries free of charge to any collecting point
of your local authority, our stores or where batteries/ rechargeable batteries are sold.
Consequently you comply with your legal obligations and contribute to environmental protection!
25
TECHNICAL DATA15.
Operating voltage: 3.6 V Lithium battery type 1/2 AA
Sampling rate: 1 s – 12 h (adjustable)
Logger measuring range: -200 to +1370 ºC / -328 to +2498 ºF
Sensor measuring range: -50 to +250 ºC / -58 to 482 ºF
Accuracy: ±1 ºC / ±2 ºF (general)
±2 ºC / ±4 ºF (max.)
Resolution: 0.1º
Operating temperature: 0 to +40 ºC / +32 to +104 ºF
Storage temperature: -10 to +60 ºC / +14 to +140 ºF
Rel. air humidity: ≤85%(Operation)
≤90%(Storage)
System requirements: Microsoft Windows® 2000, XP or Vista™
Temperature sensor wire length: 1 m
Dimensions (W x H x D): 101 x 24 x 22 mm
Weight: 172 g
Impressum
Diese Bedienungsanleitung ist eine Publikation von Voltcraft®, Lindenweg 15, D-92242 Hirschau,
Tel.-Nr. 0180/586 582 7 (www.voltcraft.de).
AlleRechteeinschließlichÜbersetzungvorbehalten.ReproduktionenjederArt,z.B.Fotokopie,Mikroverlmung,oderdieErfassungin
elektronischen Datenverarbeitungsanlagen, bedürfen der schriftlichen Genehmigung des Herausgebers.
Nachdruck, auch auszugsweise, verboten.
Diese Bedienungsanleitung entspricht dem technischen Stand bei Drucklegung. Änderung in Technik und Ausstattung vorbehalten.
© Copyright 2011 by Voltcraft®.
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany,
Phone +49 180/586 582 7 (www.voltcraft.de).
Allrightsincludingtranslation reserved. Reproductionbyanymethod, e.g. photocopy,microlming,orthe capture inelectronicdata
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2011 by Voltcraft®.
Information légales
Ce mode d’emploi est une publication de la société Voltcraft®, Lindenweg 15, D-92242 Hirschau/Allemagne,
Tél. +49 180/586 582 7 (www.voltcraft.de).
Tousdroitsréservés,ycomprisdetraduction.Toutereproduction,quellequ’ellesoit(p.ex.photocopie,microlm,saisiedans
des installations de traitement de données) nécessite une autorisation écrite de l’éditeur. Il est interdit de le réimprimer, même par
extraits.
Cemoded’emploicorrespondauniveautechniquedumomentdelamisesouspresse.Sousréservedemodicationstechniqueset
de l’équipement.
© Copyright 2011 par Voltcraft®.
Colofon
DezegebruiksaanwijzingiseenpublicatievandermaVoltcraft®,Lindenweg15,D-92242Hirschau/Duitsland,
Tel. +49 180/586 582 7 (www.voltcraft.de).
Allerechten,vertalinginbegrepen,voorbehouden.Reproductiesvanwelkeaarddanook,bijvoorbeeldfotokopie,microverlmingofde
registratie in elektronische gegevensverwerkingsapparatuur, vereisen de schriftelijke toestemming van de uitgever. Nadruk, ook van
uittreksels, verboden.
Deze gebruiksaanwijzing voldoet aan de technische stand bij het in druk bezorgen. Wijziging van techniek en uitrusting voorbehouden.
© Copyright 2011 by Voltcraft®.
V1_0111_02-SB
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

VOLTCRAFT DL-111K Owner's manual

Category
Measuring & layout tools
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI