Chesney's CUBB18 Alchemy User And Installation Instructions Manual

Category
Fireplaces
Type
User And Installation Instructions Manual

This manual is also suitable for

0
1
Decorative Fuel Effect Appliances
Technical Manual
PIN: 0558BS5932
User and Installation Instructions
Chesney’s Universal Basket Burner18
Burner Code: CUBB18
Available in Natural Gas or LPG.
NOTE
Chesneys 5 piece large log set are for Natural Gas Models only
Chesneys 12 piece small log set are for LPG Models only
2
Contents
Section
Pages
1
Unpacking / Unit Parts
3
2
Technical Data
4
3
Installation Parameters
5
-
6
4
7
-
9
5
Burner Information
10
-
31
6
Clay
Granules
32
7
Fibre coal / Log placement
33
-
39
8
Commissioning the fire unit
40
9
Briefing and handover to the customer
41
10
Servicing
42
-
45
11
Fault finding
46
12
User Instructions
47
-
56
47
Lighting the appliance
49
-
54
Changing th
55
Cleaning
56
13
Installer checklist
57
14
Dealer and Installer Information
57
Annual Service Record
58
3
1. Unpacking
Remove the appliance from its packaging, and check that it is complete and
undamaged.
If satisfied by the condition and the contents is as specified, proceed with the
installation.
The installation should only be carried out by a competent person and all gas work
must be carried out by a Gas Safe Registered person in accordance with national
and local regulations for both gas and electricity (If required).
The installation must comply with local and national building regulations.
For the Republic of Ireland, reference should be made to IS813 and ICP3 and any
guidance notes from Bord Gais.
Failure to comply with the regulations nullifies ALL guarantees.
Unit Parts
NG Logs (If supplied) Embers (If supplied Clay Granules Coals 2x Bags
with NG Logs) 1kg bag (If supplied)
LPG Logs
(If supplied)
4
2. Technical Data
Specifications for CUBB18
Oxypilot Assembly Marking
Natural Gas Burner : NG 9057, LPG Burner
LPG 9221
Gas Connection Size
8.0mm O.D. tubing
Minimum Flue Diameter (Millimetres/Inc
hes)
178.0/7.0
Minimum Flue Height (metres)
3.0
Appliance Mass (kilograms)
3.6
Gas
Type
Gas Category, Type
And Supply Pressure
Countries of Destination
AT
BE
CH
CY
CZ
DE
DK
EE
ES
FI
FR
GB
GR
HU
IE
IT
LT
NG
I
2H - G20 at 20mbar
I
2E - G20 at 20mbar
I
2E+ - G20G25at2025mbar
LPG
I
3P - G31 at 37mbar
I
3+ - G30G31 at 28-3037mbar
I
3B/P G30 G31 at 30mbar
Gas
Type
Gas Category, Type
And Supply Pressure
Countries of Destination
LU
LV
NL
NO
PL
PT
RO
SE
Sl
SK
TR
NG
I
2H - G20 at 20mbar
I
2E - G20 at 20mbar
LPG
I
3P - G31 at 37mbar
I
3+ - G30G31 at 28-3037mbar
I
3B/P G30 G31 at 30mbar
Gas
Type
Gas Category, Type
And Supply Pressure
Injector
(1 per appliance)
Heat Input
kW, Gross
(High / Low)
Burner Pressure
(Hot) mbar
(High/Low)
Marking Size
Remote (GV30/GV60)
NG
I2H - G20 at 20mbar 180
Multiholed
7x1.8mm
13.0/7.4 3.8/1.6
I2E - G20 at 20mbar 180
Multiholed
7x1.8mm
13.0/7.4 3.8/1.6
I2E+ - G20G25at2025mbar 180
Multiholed
7x1.8mm
13.0/7.4 3.8/1.6
LPG
I3P - G31 at 37mbar
18S
Single Hole
1.8mm
11.0/8.2 24.6/14.6
I3+ - G30G31 at 28-3037mbar
18S
Single Hole
1.8mm
11.0/8.2
19.0/11.3 (G30)
24.6/14.6 (G31)
I3B/P G30 G31 at 30mbar
18S
Single Hole
1.8mm
11.0/8.2 19.0/11.3
Recommended Opening Size
Model
Height Width
CUBB18
[NG]
580mm 580mm
CUBB18
[LPG]
545mm 580mm
NOTE Other types of larger flue/opening size combinations (and canopies) can
be used provided that the combustion products are cleared. If in doubt contact a
flue specialist for advice.
5
3. Installation Parameters
The fire unit must be installed and used in accordance with these
instructions.
This appliance is for decorative purposes.
For your safety it is law that all gas appliances must be installed by a
competent person, in accordance with the current gas safety
regulations applicable in the country of use.
The installation must be carried out in accordance with the relevant
local and national specifications and comply with building regulations.
The following must comply with the requirements and satisfy Building
Regulations Approved Document J.
Builders opening and Fire Chamber must be constructed of
non-combustible material
Hearth and clearance dimensions
The minimum flue opening is 178mm (7”) diameter 250 sq.
cm. (38.5 sq. inches) and a minimum height of 3m (10ft),
provided the flue which serves this appliance.
An in-line fan that complies with BS 5440: Part 1 can be used to
improve flue draught.
NOTE - The flue must not be shared with any other appliance.
Prior to installation, ensure the compliance of local distribution
conditions (E.g. The type of gas, pressure and the adjustment of the
appliance) are compatible.
The builder's opening or fireplace opening must be constructed of a
non-combustible material.
Before the fire is installed, the chimney should be swept and a flue
test in accordance with National Regulations should be carried out.
The flue must be fitted in accordance with National Regulations,
damper plates or flue restrictors must be removed or fixed
permanently in the fully open position.
The gas connection must be in accordance with National Regulations.
The pilot light and flame sensing system fitted to this fire is also an
atmosphere sensing device, this is not adjustable and must not be put
out of action. If the pilot light is damaged or faulty it should be replaced
only with the original identical unit supplied by Chesney’s Limited.
The room where the appliance is to be fitted must have a permanent
air vent with a minimum effective area of 100cm sq. to the outside air
in accordance with National Regulations and must be checked on a
regular basis to ensure there is no obstruction.
6
This appliance must not be fitted in any room where steam is present
(e.g. Bathroom).
The appliance is not fitted with an integral guard. It is recommended
that a guard be used for the protection of young children, the elderly or
infirm and also for normal use conforming to BS8423:2002, such that
access to the flame is minimised.
It is advised not to stand too close to the appliance for prolonged
periods of time; loose clothing is particularly at risk of burning due to
the presence of an unguarded flame.
It is also advised against placing combustible materials directly in front
of the appliance. Floor coverings, such as carpets, are considered to
be acceptable.
Due to the newness of materials, the fire may give off a slight smell for
a period of time after commissioning. This is quite normal and any
odours should dissipate within a few hours of operation.
7
4. Installation
Check flue soundness
A smoke pellet can be used to test the flue for effectiveness of the draw, also
checking other parts of the dwelling (including loft areas) for leakage, down-
draught etc.
If the flue is unsatisfactory seek advice from a flue specialist.
NOTE The smoke pellet gives a fair idea on the draw, but is no guarantee
that the products of combustion from the fire unit will clear, this is also to be
tested after the installation by carrying a spillage test.
Below is a guide to the flue diameter and minimum flue heights for different
size openings.
NOTE - This table is a rough guide, due to some complex flue systems in
some dwellings the suggested table may still be inadequate, contact a flue
specialist for more advice.
Opening Width
(mm)
Opening Height
(mm)
Opening
Width x Height
Floor to flue top height / Flue Diameter
Height
3.0m
Height
4.5m
Height
6.0m
Height
9.0m Height 15.0m
350 550 1925cm2 175 Dia. 175 Dia. 175 Dia. 175 Dia. 175 Dia.
400 550 2200cm2 175 Dia. 175 Dia. 175 Dia. 175 Dia. 175 Dia.
460
460
2116cm2
175
Dia.
175
Dia.
175
Dia.
175
Dia.
175
Dia.
460 550 2530cm2 200 Dia. 175 Dia. 175 Dia. 175 Dia. 175 Dia.
460 610 2806cm2 200 Dia. 200 Dia. 175 Dia. 175 Dia. 175 Dia.
610
460
2806cm2
200
Dia.
200
Dia.
175
Dia.
175
Dia.
175
Dia.
610 610 3721cm2 250 Dia. 225 Dia. 200 Dia. 200 Dia. 175 Dia.
610 760 4636cm2 300 Dia. 250 Dia. 250 Dia. 225 Dia. 200 Dia.
760 460 3496cm2 225 Dia. 225 Dia. 200 Dia. 200 Dia. 175 Dia.
760 610 4636cm2 250 Dia. 250 Dia. 250 Dia. 225 Dia. 200 Dia.
760
760
5776cm2
300
Dia.
300
Dia.
250
Dia.
250
Dia.
225
Dia.
760 910 6916cm2 350 Dia. 300 Dia. 300 Dia. 250 Dia. 250 Dia.
910 460 4186cm2 250 Dia. 225 Dia. 225 Dia. 200 Dia. 200 Dia.
910
610
5551cm2
300
Dia.
300
Dia.
250
Dia.
250
Dia.
225
Dia.
910 760 6916cm2 350 Dia. 300 Dia. 300 Dia. 250 Dia. 250 Dia.
910 910 8281cm2 350 Dia. 350 Dia. 300 Dia. 300 Dia. 250 Dia.
910
1070
9737cm2
*********
350
Dia.
350
Dia.
300
Dia.
300
Dia.
1070 460 4922cm2 300 Dia. 250 Dia. 250 Dia. 225 Dia. 200 Dia.
1070 610 6527cm2 300 Dia. 300 Dia. 300 Dia. 250 Dia. 250 Dia.
1070
760
8132cm2
350
Dia.
350
Dia.
300
Dia.
300
Dia.
250
Dia.
1070 910 9737cm2 ********* 350 Dia. 350 Dia. 300 Dia. 300 Dia.
1070 1070 11449cm2 ********* ********* 350 Dia. 350 Dia. 300 Dia.
1070
1220
13054cm2
*********
*********
*********
350
Dia.
350
Dia.
1220 460 5612cm2 300 Dia. 300 Dia. 250 Dia. 250 Dia. 225 Dia.
1220 610 7442cm2 350 Dia. 300 Dia. 300 Dia. 300 Dia. 250 Dia.
1220
76
0
9272cm2
*********
350
Dia.
350
Dia.
300
Dia.
300
Dia.
1220 910 11102cm2 ********* ********* 350 Dia. 350 Dia. 300 Dia.
1220 1070 13054cm2 ********* ********* ********* 350 Dia. 350 Dia.
1220 1220 14884cm2 ********* ********* ********* 350 Dia. 350 Dia.
1520 460 6992cm2 300 Dia. 300 Dia. 300 Dia. 250 Dia. 250 Dia.
1520
610
9272cm2
*********
350
Dia.
350
Dia.
300
Dia.
300
Dia.
1520 760 11552cm2 *********
*********
350 Dia. 350 Dia. 300 Dia.
1520 910 13831cm2 *********
*********
*********
350 Dia. 350 Dia.
1520
1070
16264cm2
*********
*********
*********
*********
350
Dia.
1520 1220 18544cm2 *********
*********
*********
*********
*********
8
Check Ventilation
Ensure the room the appliance is to be fitted has suitable ventilation the size
and type of ventilation should take into account any other gas appliance in
the room.
The room where the appliance is to be fitted must have a permanent
air vent to the outside air in accordance with Local and National
Regulations. The air vent must be checked on a regular basis to
ensure there is no obstruction.
Fitting the fire unit
The burner unit has been supplied in an assembled state with exception of
clay granules and coals/logs. All Chesney’s fire units have been tested to
ensure safety.
Ensure that the gas supply is capable of delivering the required amount of
gas, and is in accordance with the rules in force.
When laying the gas pipe work check the fire unit’s gas inlet location to
ensure a smooth run.
NOTE All gas work must be carried out by a qualified gas installer to all
relevant regulations.
An isolation valve or valves must be fitted adjacent to the appliance in
accordance with national regulations this is to allow the complete removal of
the burner control assembly, for maintenance or repair.
Chesney’s fire baskets (Sold separately) are supplied with a grate; this is not
needed for gas appliances and must be removed.
9
On certain types of fire baskets (mainly curved baskets) both grate structure bars
must be removed to enable the fitting of the burner unit.
Secure the fire unit to the fire basket.
When fitting the fire ensure that the unit is fitted under the flue opening so that no
part of the fire bed protrudes beyond the fireplace opening.
Before connecting the fire unit purge the pipes from air and debris.
Light the fire on maximum and run for approximately 20mins and check that the hot
burner pressure is in accordance with the values stated on page 4 within the
appliance specifications.
The Burner is fitted with a metal data plate supplied with the fire unit and is to
remain with the fire unit for annual services.
Image of the data plate shown below:-
10
5. Burner Information
Remote / Manual versions
11
Dimensions
12
Control Valve – Mertik GV34 / GV36
NOTE The GV36 does not have a motor attached but can be upgraded to the GV34.
13
14
Control Valve – Mertik GV60 (Fully remote controlled)
15
Features and Options
No external electrical power required.
Used with standard thermocouple and standard ODS pilot
Flame height adjustment with remote control or switch
Flame height knob may be adjusted manually, if required
AGA, CGA and CE approvals
Compact design with large capacity
Thermoelectric flame failure device
Safety interlock
Pressure regulator or throttle
Minimum rate selling with fixed or adjustable orifices
Pilot gas adjustment screw
Screen in the gas inlet area
Side outlet for second burner (not motor controlled)
GV34, 36 and 60 models require no external electrical power to operate. The battery-powered
motor allows main gas adjustment via an electric switch or remote.
In the event of a battery failure, the flame height may be adjusted by hand. The GV34 is
configured for on-off low to high main burner function. The thermoelectric flame failure device
functions with all standard thermocouple and ODS pilot burners (no powerpile necessary).
The GV34, 36, 60 Series multifunctional controls have been designed to be as interchangeable as
possible. This allows the different functions to be realized in one heating appliance.
16
Operation
Lighting Procedure
1) Turn Knob A (figure 1) slightly left towards the ignition position until reaching stop,
press down and hold for five seconds (only pilot gas flows).
2) Continue pressing down knob A while turning further left to activate piezo, continue to hold
down for 10 seconds after pilot has been lit. If pilot does not light, steps 1 and 2 can be
repeated immediately.
3) Upon lighting, release knob and turn further left to ON position. Pilot gas flows and main
gas flows in accordance to the setting (knob B).
Adjusting the flame height
To turn the fire on and/or to increase the flame height, press the ON button of the remote
handset. Continue pressing until the desired flame height is obtained. Press and hold the OFF
button to reverse the procedure. The receiver is equipped with a built-in delay, recognizable by
the flickering light, to facilitate fine adjustment of the flame.
The motorized valve is equipped with a slip clutch, allowing manual adjustment of main gas by
turning knob B.
Shut-off Procedure
1) Turn knob A right until reaching stop. In this position only pilot gas flows.
2) To shut off the valve completely, press down slightly and continue turning right from pilot
position to the OFF position. The safety interlock prevents re-ignition of the pilot flame
until the thermocouple has cooled down sufficiently (elapsed time will vary based on the
thermocouple type).
3) Switching off the remote is not necessary.
17
18
19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59