Haier QBJ1-270A58E Instructions For Use Manual

Type
Instructions For Use Manual
Instruction for use
QBJ1-130A58E
QBJ1-150A58E
QBJ1-175A58E
QBJ1-200A58E
QBJ1-230A58E
QBJ1-270A58E
Please read this manual before usage
Retain it for future reference
Solar Water Heater
Content
Features
Before use
Assembly Instruction
Appearance and parts
Technical parameter
1
1
1
2
3
4
5
5
5
6
7
7
8
11
11
10
Precautions
Notice
Technical data
4
The location
Exterior and installation dimension
Tank assembly
Frame assembly
Frame fastness
Glass tube assembly
Extraventricular plumbing instructions
Indoor plumbing instructions
Installation notice
Using Instruction
The operation method
Troubles treatment
3
Pipelines thermal insulation notice
9
The product with controller installation
and using notice
9
Packing list
Technical data
1
1. Inner cylinder:
2. Insulation: Polyurethane foam, thickness-45 mm, good heat preservation effect.
3. Outer shell: Aluminium / zinc coated steel sheet.
4. Frame: Steady structure, shapely and durable .
SUS 304 stainless steel, food grade.
Features
Technical parameter
Appearance and parts
Models
Specification of tubes
Collector frame angle
standard fixed
Number of tubes
Aperture area
Usable water
58mm 1800mm all glass evacuated tubular collector
45
Remarks:1. The warp of a parameters is 3%. the warp of usable water
parameters is 5%. The permitted error limit of other parameters is 10%
perture area
QBJ1-130A58E QBJ1-150A58E QBJ1-175A58E QBJ1-200A58E
14
16
19
22
2
1.79m
2
2.07m
2
2.48m
2
2.90m
130L
150L 175L 200L
Electric auxiliary
heating
Rated power: 1500W
Water level sensor
Using the water level sensor with the height of 360 mm
Outer shell
Evacuated tubes
Base support
Cover
Silicon seal ring
Frame
Foot cushion
QBJ1-230A58E QBJ1-270A58E
25
30
3.35
2
m 4.03
2
m
230L
270L
Total water volume
169L 195L 228L 262L
300L 354L
Precautions
Precautions
1.
2. Avoiding irradiation without water after installation, it can't be used immediately, it
should be sheltered.
3. When supplying water at the first time, it should be operated in the morning or
evening or the condition of short of light; avoid supplying water in strong sunshine,
in order to prevent vacuum tubes bombing.
4. If the water pressure isn't enough for water supply, please install an pressurize
equipment.
5. When the hot water is to be used, don't place the spray head face yourself until the
water temperature is suitable.
6. This product can supply the water depend on the fall of the tank and the water exit ,
an pressurize equipment is recommended while the water couldn't be supplied
normally due to the low fall.
7. Do not supply cold water more than once in a low solar irradiance day.
8. The energy is from solar, in the days that lack of solar such as rainy or snowy day,
the temperature of the water may can't reach your demand,
9. Make sure the evacuated tubes clean, hose off the dust and dirt on the tubes and
the reflector before the winter comes.
10. The evacuated tubes resist as low temperature as -70 when tubes is emptied.
The tank should remain filled up during continuously cloudy or snowing days in winter,
in addition every two days the cold water in the tank should be changed to prevent the
water in the tank from freezing which might damage the tubes.
When using the water heater with electric heating, ensure that electric heating and
electric tracing belt are closed.
If there isn't electric heating ,
it may not be used normally.
2
Before use
3
Notice
Please take time to read this manual and familiarize yourself with the function
of this production.
1. Please check out the packing list.
2.If you fix electric auxiliary heating and controller, please select Haier
equipped products.
3. To avoid the scald, please mix the hot and the cold water before use it.
4. In order to protect the tank ,please don't refit or wall up the air supply pipe
and the overflow pipe.
Assembly Instruction
Notice: The solar water heater shall be installed by professional.
Exterior and installation dimension:
4
Models
Exterior dimension(mm)
Installation dimension(mm)
1. Please install the solar water heater in the area that avoid the thunder.
2. Solar water heater angle range: east to south for 10 , west to south for 15 .
3. There shouldn't be any hindrance in front of the heater ,or the distance should over
L, L=H/tg(66.5
a) H:height of the hindrance; a: latitude of the area
Remarks: The permitted error limit of above parameters is 10%.
The location:
A
D
QBJ1-130A58E
QBJ1-150A58E
QBJ1-175A58E
QBJ1-200A58E
B
H
QBJ1-230A58E
QBJ1-270A58E
Tank assembly
1. Unpacking the tank, rip off the protection film. Uninstall the nut and cushion.
2. Place tank onto tank bracket cradle, inserting protruding bolts into holes.
fasten with nuts.
Notice:
1. Rip off the protection film after the installation to avoid the destroy of the tank,
and please don't use the sharp tool.
2. Leave nuts loose since some adjustment may be necessary after fitting tubes.
3. When assembling the water tank, keep the center line of vacuum tubes
connecting holes parallel with the diagonal pillar of bracket.
Frame assembly
Please consult the accessional paper for figure of the frame and packing list in
the packing of frame.
F
rame fastness
1. Peg the feet of the heater into the earth with prepared iron or into the concrete
brick with intumescent bolt.
2. Adjust the height of the frame with the water-proof cushion to keep the tank
aclinic and each foot balanceable.
Notice:
1. Make sure that the feet are all attach the floor closely, or it will cause the
distortion of the frame.
2. Please use the tight wire to fasten the tank and frame in the area that the
typhoon occurred frequently.
3. The installation of the solar water heater should be steadily or it will cause the
destruction and the accident.
Assembly Instruction
5
Assembly Instruction
Glass tube assembly
1. Keep tubes out of the irradiation while assembling the unit or a scald may be
caused.
2. Place the rounded side of rubber seal downwards on the open end of tubes.(A)
3. Insert the tube into base support of locating hole with gentle pressure and twisting
motion.
4. Holding the tube, fix base support into base bracket (B), insert tube into base
support (C).
5. Slide the tube down 1 cm, Slide black rubber seal up the tubes until it sits flush
with tank(D).
6. Insert one tube on either end of the tank to achieve alignment of unit.
Notice:
1. Make sure the s
ilicon seal ring are clean and well positioned.
2. Place the rounded side of rubber seal downwards on open end of tube.
Slide it down 10 cm. Wet open end of tube to make it easier to insert.
6
Silicon seal ring
Rubber seal
Evacuated tubes
Evacuated
tubes
Rubber seal
hold position
Base support
Base support
Base bracket
Base bracket
A
C
B
D
Extraventricular plumbing instructions
Assembly Instruction
7
Air supply pipe
Over flow pipe
Over flow hole (
conect to the room
A
Indoor plumbing instructions
Inlet/outlet hole (1/2 ), conect
to the room
Air supply hole(1/2 )
forbidden to stem
QBJ1-130A58E
QBJ1-150A58E QBJ1-175A58E QBJ1-200A58E
A
b
a
Remarks: The permitted error limit of above parameters is 10%.
Electric heating flange
a
b
Sensor hole 3/4
Sensor
Electric heating pipe
Connect
racing belt
the line
of t
Water level sensor
Electric heating
Pre-burrided
cord slot
Solar water heater
Hot water
Tap water
Controller
QBJ1-230A58E QBJ1-270A58E
1. Any alteration to the structure of the solar water heater may cause the trouble
while using it.
2. There are 5 connection methods of the water pipe into the room, they are smoke
way, vent-pipe hole on the wall appropriative solar well prepared cannula
and the first three kinds are common. Before the installation, our professional
will consult the room's situation and choose the suitable location to bring you
convenience. A upend slope is necessary ,and should be wind-tight to prevent
the rainy water or smell's entrance.
3. Keep the placket of the overflow pipe downwards and fasten it so that the liquid
can be lead to the cloaca directly, and please notice that the distance of the
overflow pipe and the cloaca should less than 15cm. Don't placed the pipe
optionally, so can avoid the water spatter.
4. Don't install the valve in the pipeline to insure that the signal which shows the
water is overflow will be worked normally.
5.To avoid the water in the tank flow inverted, an unilateralism valve should be
installed at the joint of the water pipe and the tap water.
6. The installation project should be confirmed by our professional service
personnel when install several sets of these series.
Assembly Instruction
8
Please install another one-
directional valve at the cold and hot
water pipes if the solar tank is
connected with other kinds of tanks
to avoid the exceed pressure in
these tanks flowing backwards to
the solar tank and lead accidents.
Other
water heaters
Tap water
Contact to the water tank
Illustration of connect the solar tank with other tanks
Hot water
Installation notice
Assembly Instruction
Pipelines thermal insulation notice
1.Outdoor pipelines should be thermal insulated according to local climate,
bad thermal insulation may lead to heat loss.
2.The outlet used by electric tracing belt must ground reliably. The rated current
of outlet is less than 10A, ensure is connected to plug reliably.
3.Fixing electric tracing belt on cold and hot water pipes, in order to touch well,
it should be fixed with insulating tape per 500 mm.
4.Waterproof should be tied up on thermal insulating pipes, for example
aluminum foil cloth, glass fibre cloth, ethylene polyester waterproof film etc.
Note: in cold area, electric tracing belt should be fixed on outdoor pipelines.
Otherwise when the environmental temperature is lower than -5 , any
innocent thermal insulation will lead to the pipelines frozen, resulting in the
pipelines damage.
The product with controller installation and using notice
1.If you fix controller, please select Haier products, otherwise our company
won't be responsible for personal injure and damage of water heater.
2.Haier has the controller used in domestic water heater, which has cord and
plug, and they are connected well. Please select the electrical outlet of good
quality, its rated current is not less than 16 A, and must ground reliably.
3.The cord of controller mustn't be layed in thermal insulating layer of pipelines,
should be layed out of thermal insulating layer along the thermal insulating
layer of pipelines.
4.The location used to hang up controller should be reserved, suggesting
height is 1.4 m~1.6m from ground.
5.According to the controlling function you choose, supply and signal cords
should be reserved between roofing and controller. Electric tracing belt needs
RVV2 0.75 protective cord, electric needs RVV3 1 protective cord, water
level display needs RVV3 0.12 protective cord, if electromagnetic valve is
fixed on roofing, it needs RVV2 0.2 protective cord.
6.If the controller you choose has water level display function, the water level
sensor whose height is 360mm should be chosen.
9
10
Assembly Instruction Using Instruction
7.If the controller you choose has automatic water supply function,
electromagnetic valve must be fixed in room horizontally; the direction of
arrowhead labled on valve is the direction of water running out. Suggest fixing
manual water supply side line, ensure that users can use water heater normally
when the electromagnetic valve is damaged.
8.If the supply cord is damaged, in order to avoid danger, it must be replaced by
factory or maintenance department or professional staff.
9.Other requirements refer to controller introduction.
The operation method
1.K1 valve is open before using water, K2, K3 valves are closed
2.The controller is set in the status of automatical water supply, the
electromagnetic valve won't close until arriving at the set water level, and water
supply is over
3.Open K2 when you want to use the water, open K3 to adjust the temperature if it
is too high.
4.Close K2 and K3 when finish using the water.
Air supply pipe
Controller
Back
valve
Solenoid
valve
Sensor
Over flow pipe
Electric heating pipe
Tap water
Troubles treatment
Phenomenon
No water supply
The temperature
isn't high enough
Possible reason
The tank is empty
The pipeline or the connection
is impeded
The evacuated tubes have
damaged
The water supply is paused or low
water pressure
The pipeline or the connection is
Damaged
Valve for water supply is unstuck
or already damaged
The evacuated tube can't work
effectively for there are hindrance
in front of it
Treatment
Supply water according to the
manual
Maintain the pipeline or clean
the connection
Replacing the tubes
Waiting for the supplying again
Maintain the pipeline and
the connection
Screw down the valve or
replacing it
Change the location or move
the hindranc
Using Instruction
11
The controller
can't reach the
programmed
level or there is
no water
Too much ash on the tube
Tidy the tube
Packing list
Main parts
Quantity
Storage
tank
box
Storage tank
Manual
Frame box
Tank
bracket
box
Left supportbracket
Right supportbracket
Evacuated tubes
Controller box
1
1
1
1
1
1
1
1
1
1
2
25
1
1
2
30
Rev. 01
Specific Number 0040500680F
Made in China
HR-QBJ1-KSD
Instruction for use
Solar water heater controller
Please read this manual before usage
Retain it for future reference
Content
Function Instruction
Using Instruction
System components
Working principle
1
1
2
3
4
8
9
11
11
9
Control panel
Installation Instructions
5
Safety Notice
Product Instruction
Main technical specification
Main function
Switch on/off the controller and
parameters setting
Main function operation
Error display and handling
Electric water heater, water temperature
and level sensor installation
Indoor pipe and electromagnet
ic valve
installation notice
Installation notice
Controller installation
Wiring
11
13
Packing list
Safety Notice
1.The product can't be watered directly
2.Containing 220V voltage, forbid user to open back cap
3.Live operation is forbidden when installing and maintaining
4.Forbid children under 10 years old to use a
lone
5.Stop electric heating before using hot water
6.If supply cord is damaged, in order to avoid risk, it must be replaced by factory
or maintenance department or full-time staff.
Product Instruction
System components
The system is composed of main controller, water temperature and water
level sensor, electromagnetic valve, electric heater, cable etc.
Working principle
Water level and temperature sensor detects real-time water level and temperature
signals, these s
ignals being amplified and A/D converted are transmitted into the
CPU, the CPU displays the relevant data and user's setting information with the
measured data and judging, CPU issues kinds of controlling instruction to achieve
the automatic intelligent controlling function. Wor king flow chart as follows:
Safety Notice Product Instruction
1
Display un it
Key set
CPU
Water level sensor
Temperature sensor
Cont rol
unit
Watersupply
equi pmen t
Electric heating
equi pmen t
Water level/
temperature signal
1.Power supply: AC220V 10%. 50Hz
2.Power loss: Power loss < 5W
3.Temperature accuracy :2
4.Temperature range: 0~99
5.Water supply grade: 5 grids
6.Electric heater power: 1500W
7.Controllable the length of self-limiting electricity heating be
lt:10 meters(power
is 20W/mh)
8.Controllable the power of pump: 200W
9.Leaking current action: 10~15mA/0.1s
Main technical specification
10.Electromagnetic valve: DC12V,work pressure 0.02MPa~0.8MPa
11.E xterior dimensions: 182mm 130mm 48mm
12.Allowable environment humidity: <90%RH
13.Waterproof grade: IPX4.
Function Instruction
2
C ontrol panel
Function Instruction
A
B
C
D
E
F
B : Time activated
A : Anti-freezing/adjusting
C : Manual heating
D : Manual water supply
E : Set
F : Power
1.Anti-freeze sign: the sign shows that self-limiting electricity heating belt is
working, flicker shows it is paused.
2.Time heating sign: the sign shows that electric heati
ng is waiting for timing
3.Time water supply: the sign shows that this operation is waiting for timing.
4.Clock display: display the current time.
.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Haier QBJ1-270A58E Instructions For Use Manual

Type
Instructions For Use Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI