American Standard Jetbrook 1.0 GPF Blowout Urinal 6574.011, 6571.014, 6574.011 User manual

  • Hello! I am an AI chatbot trained to assist you with the American Standard Jetbrook 1.0 GPF Blowout Urinal 6574.011 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
M85
© 2008 AS America Inc.
JETBROOK™
URINAL
VITREOUS CHINA
JETBROOK™ 1.0 GPF BLOWOUT URINAL
Vitreous china
Front jetted, blowout-type ush action
21" Extended Lip
1-1/2" glazed trapway
Low-consumption (3.8 Lpf/1.0 gpf)
Flushing rim
1-1/4" inlet spud
Outlet connection threaded 2" inside (NPTF)
Wall hanger
Fixture only
Meets ANSI ush requirements at 1.0 GPF
6571.014 Top spud 2", outlet
6574.011 Back spud 2", outlet
Nominal Dimensions:
527 x 356 x 400mm
(20-3/4" x 14" x 16")
Recommended working pressure – between
20 psi at valve when ushing and 80 psi static
Compliance Certications -
Meets or Exceeds the Following Specications:
• ASME A112.19.2 for Vitreous China Fixtures
Revised 11/08
To Be Specied:
Color: White Bone Silver Linen
Flush Valve:
American Standard Selectronic
#6063.101.002
DC Power (Top Spud)
American Standard Selectronic
#6063.310.007
DC Power (Back Spud)
American Standard Selectronic
#6062.310.007
AC Power (Back Spud)
American Standard Selectronic
#6061.310.007
Multi AC Power (Back Spud)
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
BARRIER FREE
M86
© 2008 AS America Inc.
JETBROOK™
URINAL
VITREOUS CHINA
NOTES:
THIS URINAL IS DESIGNED FOR USE WITH FLUSH VALVE ONLY.
FLUSH VALVE NOT INCLUDED WITH FIXTURE AND MUST BE
ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
IMPORTANT: Dimensions of xtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND
FACILITIES - CHECK LOCAL CODES.
When installed so top of rim is 432mm (17") from finished floor.
2 N.P.T.
FEMALE
OUTLET
CONNECTION
3mm
(1/8)
3mm
(1/8)
2 N.P.T.
INSIDE THREADS
178mm
(7)
356mm
(14)
121mm
(4-3/4)
178mm
(7)
152mm
(6)
527mm
(20-3/4)
57mm
(2-1/4)
FINISHED
WALL
FINISHED
FLOOR
1-1/4
SPUD
292mm
(11-1/2)
406mm
(16)
187mm
(7-3/8)
64mm
(2-1/2)
432mm
(17)
495mm
(19-1/2)
OPTIONAL
TO FINISHED
FLOOR
C/L OF
OUTLET
HANGER
1" N.P.T. OR
C.W.T. SUPPLY
TO FLUSH VALVE
22mm
(7/8)
GASKET
DETAIL OF OUTLET CONNECTION
FINISHED WALL
2 N.P.T.
FEMALE
OUTLET
CONNECTION
3mm
(1/8)
3mm
(1/8)
2 N.P.T.
INSIDE THREADS
178mm
(7)
356mm
(14)
178mm
(7)
152mm
(6)
527mm
(20-3/4)
54mm
(2-1/8)
FINISHED
WALL
FINISHED
FLOOR
1-1/4
SPUD
406mm
(16)
187mm
(7-3/8)
64mm
(2-1/2)
432mm
(17)
495mm
(19-1/2)
OPTIONAL
TO FINISHED
FLOOR
C/L OF
OUTLET
HANGER
22mm
(7/8)
GASKET
DETAIL OF OUTLET CONNECTION
FINISHED WALL
6571.014 TOP SPUD
6574.011 BACK SPUD
BARRIER FREE
Revised 11/08
/