Stylus Pro 4000 Field Repair Guide 4/28/05
Printer Component, Software Item, LCD Display, Printer Button Page 9.
PF Resolution: Initialize OK? (Resets this counter only)
Head Record: Initialize OK? (Resets this counter only)
Wiping Record: Initialize OK? (Resets this counter only)
Rab. Record: Initialize OK? (Resets this counter only)
Waste Record: Initialize OK? (Resets this counter only)
CRmot Record: Initialize OK? (Resets this counter only)
PFmot Record: Initialize OK? (Resets this counter only)
Lever Record: Initialize OK? (Resets this counter only)
Cover Record: Initialize OK? (Resets this counter only)
Ink Lever Record: Initialize OK? (Resets this counter only)
Update: InkParameter: Init. Fill: (Set, Reset) (Reset, turns off the initial fill)
MntTank: (On, Off) (Turn on or off the Maintenance Tank CSIC)
Mask Type: Dispersion, Regular (?)
PF BiD Adjust: (+/- n) (?)
Uni-D Trap: (On, Off) (?)
Display: Address: (Used for displaying data at specific RAM addresses)
Life: CR Motor, PF Motor, CR+PF Motor, Roller, Roller Rel, D/E Chg, Hopper, ASFLoad, Cutter, Head U/D,
Head Lock, Cleaning, Print, Total Life, CR+PF+Fire, TotalLife2, TotalLife3, Check (Used for design testing
of these devices and assemblies)
Service Config
Chg DEVICE-ID: *Sty Pro 4000, PX-6000 (Used for choosing the Plug and Play printer name)
NPD: *1, 0, 2 (Defines the ink type (1= pigment, 0 = new/undefined, 2 = dye))
EDMODE: *X, O,N (X=CSIC used fully, N=Non-USA Cartridges are OK, O=CSIC is disabled)
MD TBL: ID = (1-7D Hex) (“Modifying parameter of media table is available”)
View Counters (Displays the usage/life counter information for the following devices/operations)
Cutter, Cutter Total, Total Pages, Maint Tank, CR Motor, CR Total, PF Motor, Nozzle A, Nozzle B,
Nozzle C, Nozzle D, Nozzle E, Nozzle F, Nozzle G, FL Box, Cleaner, Sponge, ASF, Feed Roller, PG