Perlick CR24R-1-2R Installation guide

Type
Installation guide
FORM NO. Z2496
REV. A-01/30/2018
PERLICK COLLECTION 24” COLUMN REFRIGERATION
To prevent appliance damage and injury, read these instrucons thoroughly
prior to installaon.
CR24
INSTALLATION
INSTRUCTIONS
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
2 | perlick.com/residential
PRODUCT IDENTIFICATION PLATE
Your product informaon can be found on the products
idencaon plate. The idencaon plate for CR24 column
refrigeraon models is located on the sidewall behind the toe
kick plate. To access the indencaon plate, simply remove
the toe kick plate (grill). The idencaon plate will be adhered
to the right sidewall.
INTRODUCTION
Congratulaons on your purchase of a Perlick Collecon column
refrigeraon appliance. This manual has been prepared to assist
you in the installaon of your column refrigerator, freezer and
wine reserve.
We dedicate considerable me to ensure that our products
provide the highest level of customer sasfacon. We thank
you for selecng Perlick products for your home and assure you
of our connuing interest in your sasfacon.
WARRANTY REGISTRATION
To register your Perlick product, visit our website at
www.perlick.com/RegisterMyPerlick and ll out the form.
Once completed, click on the ‘Submit Warranty Registraon’. Be
sure to register your product immediately upon installaon to
receive the warranty from installaon date instead of shipment
date. If le blank, the date will revert back to shipment date.
CONTENTS
3 Safety Consideraons
4 Prior to Installaon
4 Opening Dimensions (Single and Dual)
5 Niche/Product Dimensions
6 Electrical
6 An-p Bracket
7 Leveling/Alignment
10 Door/Side Panel Informaon
16 Door Panel Installaon/Adjustment
18 Door Trim Installaon
19 Compleon - Grill Installaon
20 Toe Kick Clearance
21 Installing Filters
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 3
SAFETY CONSIDERATIONS
IMPORTANT SAFETY INFORMATION
Please review the following safety precauons and read all
instrucons prior to product installaon. Aer the compleon
of installaon, keep these instrucons in a safe place for future
reference.
Please take special care when reading the highlighted
informaon in this guide. This informaon is coded as follows:
DAN Thisindicatesthatahazardoussituaon
mayoccurwheninstruconsarenotfollowed.Itisimperive
thatdireconsinthisguidearefollowedtopreventpossible
serious injury or death.
Thisindicatesasituaonwhereminor
injury,productorcabinetdamagemayoccurifthefollowing
instruconsarenotfollowed.
This highlights informaon that is of
signicant importance.
WARNING
DANGER
!
CAUTION
SAFETY PRECAUTIONS
Please take note of the following safety precauons prior to
moving, unpacking and installing your Perlick column.
DAN Takecarewhenhandling,movingorusing
therefrigeratedcabinettoavoiddamagingtherefrigerant
tubing.Damagingtherefrigeranttubingincreasestheriskof
leakageandcanbedangerous.
Perlickcolumnsweighupto550lbs.Take
specialcarewhenmovingtopreventseriousinjury.
Perlickcolumnsaretopheavy.Itis
importantthatthedoorissecuredclosedunlinstalled.
Installasdirectedtopreventpping.
Donotuseorstoreammableliquids(ie;
gasoline)orvaporsnearappliances.
Inspecttheelectricalcordandplugfor
damage prior to plugging the unit in.
Intheeventthatserviceisneccessary,
repairworkmustbeperformedbyaPerlickauthorized
servicerastominimizetheriskofpossibleigniondue
toincorrectpartsorimproperservice.Workdoneby
unqualiedindividualscouldpotenallybedangerousand
willvoidthewarranty.Componentpartswillbereplaced
withlikecomponentsfromPerlick.
DANGER
!
DANGER
!
DANGER
!
DANGER
!
DANGER
!
DANGER
!
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
4 | perlick.com/residential
PRIOR TO INSTALLATION
PRIOR TO INSTALLATION
Before beginning installaon, carefully
inspect the cabinet for hidden damage. If damage is discovered,
immediately le a claim with the transportaon company.
Perlick is not responsible for damage in transit.
When moving the unit, be sure to protect
nished ooring with appropriate material to avoid damage
from moving the appliance.
If the unit has been laid on its back or sides,
place unit upright and allow minimum of 24 hours before
connecng the unit. Failure to do so can aect the funcon and
performance of the appliance.
This appliance should be installed in dry,
venlated indoor locaon. The ambient temperature of the
locaon must be between 55°F (13°C) and 100°F (43°C) for
opmal performance.
This product must be installed on a level
oor for safety and opmal performance. The base must be
at to ensure an-p brackets properly funcon and that
the refrigeraon system is level. Any walls and surrounding
furniture/xtures need to be securely aached to the oor, wall
studs or concrete prior to installaon of the column.
To ensure proper performance, the air
intake (toe kick) must not be blocked. Perlick refrigeraon is
front-breathing — covering the intake will cause the system to
overheat and fail.
In addion, the appliance must not be in direct exposure of
constant sunlight or excessive heat. If it must be installed next
to a heat source, such as a cooking appliance or radiant heat,
you must install an insulang plate between the column and
heat source.
When fully stocked, Perlick column refrigeraon is very heavy.
To ensure the safety and prevent home damage, the load-
bearing capacity of your oor must be 846 lbs (384 kg).
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
INSTALLATION TOOLS AND MATERIALS
Screwdrivers (standard and #2 Phillips)
Power drill
Drill bits
13mm socket or wrench set
2’ and 4’ levels
Material to protect ooring and surrounding cabinetry
OPENING DIMENSIONS - SINGLE UNIT
The depth of each Perlick column is 24” (610). Allow for
panel thickness when planning the nished opening depth. A
minimum of a 4” (102) nished return is required on all sides
of the opening. See page 5 for niche and product dimension
drawings.
It is important that the side walls of the niche are plumb prior
to installaon. The minimum thickness of both the side walls
and the top wall must be 5/8” (16). A thickness of 3/4” (19) is
recommended for toe kick panels.
Framed cabinets will require addional nished ller material
behind the face frame for a proper installaon. Refer to the
illustraon on page 5.
OPENING DIMENSIONS - TWO UNITS
When installing two units side-by-side, a Perlick Dual Installaon
Kit (part number CR-ACC-D1) is required. You must plan for
both units plus dual installaon kit when planning the cut-out
dimensions. Thecutoutwidthfordualinstallaonsis48-1/2”
For more informaon, see instrucons that accompany the CR-
ACC-D1.
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 5
NICHE / PRODUCT DIMENSIONS
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
6 | perlick.com/residential
ELECTRICAL
Serious electroculon hazard. Electrical
grounding is required. This appliance is equipped with a
3-prong (grounding) polarizing plug for your protecon against
possible shock hazards. Failure to comply with these electrical
guidelines may result in possible death or serious injury, re or
loss of property.
Never use an extension cord to connect unit
to electrical source. Do not use a two-prong adapter or remove
the power cord grounding prong.
Installaon must comply with all applicable electrical codes.
The electrical supply must be located within the shaded area
of the illustraon below. A separate circuit, servicing only this
appliance, is required. A ground fault circuit interrupter (GFCI)
is not recommended and may cause interrupon of operaon.
The outlet should be placed in the hatched area dimensioned
below.
Electrical Supply 115V, 60 Hz., Phase 2, 3.3 amps
Service Dedicated 15 amp circuit
Power/Cord Type/ Length NEMA 5-15P w/5’ power cord
WARNING
DANGER
!
ANTI-TIP BRACKET
To prevent the unit from pping forward,
the an-p bracket must be installed. Use all an-p bracket
hardware as instructed. Level as instructed on page 7 prior to
installing an-p bracket(s)
The an-p bracket and supporng hardware is included with
your unit. Please note that four an-p brackets are required
for each unit or dual installaon. In the case of dual installaon,
each individual unit must be ouied with the two an-p
brackets on cabinet sides for a total of four.
For drawings of the an-p bracket installaon on integrated
(built-in) units, see page 8. For drawings of the an-p bracket
installaon on freestanding units, see page 9.
Verify there are no electrical wires or
plumbing in the area which the screws could penetrate.
Always wear safety glasses and use other
necessary protecve devices or apparel when installing or
working with anchors. Anchors are not recommended for use in
lightweight masonry material such as block or brick, or for use
in new concrete which has not had sucient me to cure. The
use of core drills is not recommended to drill holes for anchors.
WARNING
WARNING
CAUTION
ELECTRICAL / ANTI-TIP BRACKET / PRODUCT PLACEMENT
PLACEMENT
Before moving unit into posion, secure the
door closed and protect any nished ooring.
Use an appliance dolly to move the unit near the opening.
CAUTION
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 7
LEVELING / ALIGNMENT
LEVELING/ALIGNMENT
Move the unit near the opening. Plug the power cord into the
grounded outlet and roll the unit into posion. Push unit into
place.
Front and rear leveling legs can be adjusted from the front once
the unit is posioned. To access leveling adjustment access
holes, remove toe kick grill.
Once the unit is in posion, height adjustment can be made
from the front. Using the hex driver leveling tool, turn clockwise
to raise the unit or counterclockwise to lower. Refer to the
illustraon below.
WARNING
CAUTION
When the unit is properly leveled, door adjustments are less
likely to be needed.
To reduce the possibility of the unit pping
forward, the front leveling legs must be in contact with the
oor.
The refrigerated cabinet should be level for
proper operaon, such as door closing, drawer and shelf slide
operaon.
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
8 | perlick.com/residential
ANTI-TIP BRACKET INSTALLATION FOR INTEGRATED INSTALLATION
NOTE: Do not fasten an-p brackets to
adjacent cabinetry unl the cabinet has been
leveled.
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 9
ANTI-TIP BRACKET INSTALLATION FOR FREESTANDING INSTALLATION
NOTE: Cabinet must be leveled before securing
to wall with an-p bracket.
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
10 | perlick.com/residential
DOOR / SIDE PANEL INFORMATION
Finish sides of surrounding cabinetry — they will be visible
when the door is open. The height of the custom door panel
can extend beyond the typical panel height provided the door
and overlay combined do not exceed 242 lbs (110) .
See page 15 for screw zone for overlay panels. Hatch areas
should provide enough thickness for wood screw and overlay
aachment brackets.
SIDE PANELS
Units that are freestanding or parally built-in need to be
nished with custom panels. Custom panels can be built to
customer specicaons to match surrounding cabinetry.
DOOR PANELS
Perlick column refrigeraon comes ready to accept a customer
supplied overlay door panel and customer supplied handle.
Stainless steel door panels and Perlick handles are also
available, and are sold separately of the unit itself. Stainless
steel panels and handles can be purchased through an
authorized Perlick dealer.
STAINLESS STEEL DOOR PANELS
Stainless steel door panels for solid and glass door models
are available through an authorized Perlick dealer. Panels are
constructed of 304 stainless steel (front) and 403 (back plate)
and have a thickness of 3/4” (19). Always allow for panel
thickness when planning the nished opening depth.
Stainless steel panels come pre-drilled for a Perlick handle.
Please note that the Perlick Pro Handle is included with the
purchase of a stainless steel panel.
CUSTOM OVERLAY DOOR PANEL
Perlick columns come ready to accept customer-supplied door
panel and handle hardware. The thickness of the custom panel
can vary. A minimum 5/8” (16) thick panel is required, but
the thickness can be increased provided it does not exceed
the maximum panel weight is 65 lbs (29). Please note that
the combined door and overlay weight cannot exceed 242 lbs
(110). The depth of each model is 24” (610) without a nished
overlay. Allow for panel thickness when planning the nished
opening depth. Templates for 4” and 6” solid and glass door
models can be found on pages 11-14.
Reveals between panels can vary – 1/8” (3) is the minimum.
When installing a panel thicker than 3/4”
(19), the 90° stop may be required to prevent damage to the
unit and adjacent cabinetry.
As reveals between cabinetry and the unit
decrease, severe nger pinching can occur while the door is
closing.
CAUTION
CAUTION
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 11
SOLID DOOR TEMPLATE FOR 4” TOE KICK
23
3
4
"
79
7
8
"
12
1
2
"
36
1
2
"
60
1
2
"
3
8
"
3
8
"
3
8
"
(4X)
.136 .500
2
1
16
"
19
5
8
"
2
1
16
"
1
3
4
"
2
1
4
"
7
5
8
"
9
3
8
"
14
3
8
"
16
1
8
"
11
7
8
"
1
11
16
"
(2X)
.136
.250
6
3
4
"
A
3
4
"
1
8
"
1/2" (6X)
3
16
"
1/2" (6X)
DETAIL A
SCALE 1 : 2
OVERLAY MTG CLIP DETAIL
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
C
REVISED CLIP HOLE LOCATIONS AND COND.
AIRFLOW MTG HOLE LOCATIONS
11/8/2017
JMP
B
ADDED CONDENSER DIVIDER HOLES
10/3/2017
JMP
A
RELEASE FOR PRODUCTION
8/25/2017
JMP
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007916.slddrw
04/11/2017
11/08/2017
GJ
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
Ang = ±1.0°
Frac. = ±1/16
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPVD BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007916
1007916-1
COLUMN REFRIGERATOR / FREEZER
DOOR WOOD FASCIA - 4" TOE KICK
SCALE = 1:10
SHEET 1 OF 2
A
WOOD
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
12 | perlick.com/residential
SOLID DOOR TEMPLATE FOR 6” TOE KICK
23
3
4
"
77
7
8
"
12
1
2
"
36
1
2
"
60
1
2
"
3
8
"
3
8
"
3
8
"
(4X)
.136 .500
2
1
16
"
19
5
8
"
2
1
16
"
7
5
8
"
9
3
8
"
14
3
8
"
16
1
8
"
1
3
4
"
2
1
4
"
(12X)
.188
.250
11
7
8
"
1
3
4
"
4
7
8
"
(2X)
.136
.250
B
3
4
"
1
8
"
1/2" (6X)
3
16
"
1/2" (6X)
DETAIL B
SCALE 1 : 2
OVERLAY MTG CLIP DETAIL
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
C
REVISED CLIP HOLE LOCATIONS AND COND.
AIRFLOW MTG HOLE LOCATIONS
11/8/2017
JMP
B
ADDED CONDENSER DIVIDER HOLES
10/3/2017
JMP
A
RELEASE FOR PRODUCTION
8/25/2017
JMP
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007916.slddrw
04/11/2017
11/08/2017
GJ
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
Ang = ±1.0°
Frac. = ±1/16
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPVD BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007916
1007916-2
COLUMN REFRIGERATOR / FREEZER
DOOR WOOD FASCIA - 6" TOE KICK
SCALE = 1:10
SHEET 2 OF 2
A
WOOD
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 13
GLASS DOOR TEMPLATE FOR 4” TOE KICK
7
5
8
"
16
1
8
"
12
1
2
"
3
8
"
36
1
2
"
60
1
2
"
6
5
8
"
60"
CUTOUT
17" CUTOUT
2
1
16
" TYP
19
5
8
" TYP
1
3
4
"
3
4
"
FOR LOCK OPTIONAL
USE DRILL FIXTURE TO
LOCATE HOLE
23
3
4
"
79
7
8
"
3
3
8
"
.136
.500 (4X)
3
8
"
3
8
"
2
1
4
"
14
3
8
"
9
3
8
"
11
7
8
"
.136
.500 (2X)
1
11
16
"
6
3
4
"
A
3
4
"
1
8
"
1/2" (6X)
3
16
"
1/2" (6X)
DETAIL A
SCALE 1 : 2
OVERLAY CLIP MTG HOLES
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
F
REVISED MTG HOLE LOCATIONS AND COND. AIRFLOW
DIVIDER MTG HOLES
11/8/2017
JMP
E
UPDATED CLIP MTG HOLE LOCATIONS
10/6/2017
JMP
D
REVISED WINDOW SIZE BY INCREASE CUTOUT WIDTH AND
HEIGHT BY 1-1/4" OVERALL
10/5/2017
JMP
C
ADDED HOLES FOR CONDENSER AIR DIVIDER
10/3/2017
JMP
B
UPDATED HOLE PATTERN FOR ADJUSTMENT BRKT
8/25/2017
JMP
A
INITIAL RELEASE
11/8/2016
TEC
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007917.slddrw
11/28/2016
11/08/2017
JMP
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPROVED BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007917
1007917
FOR COLUMN WINE
OVERLAY, WOOD, 4'' TOE KICK
SCALE = 1:10
SHEET 1 OF 4
A
WOOD
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
14 | perlick.com/residential
GLASS DOOR TEMPLATE FOR 6” TOE KICK
7
5
8
"
16
1
8
"
12
1
2
"
3
8
"
36
1
2
"
60
1
2
"
6
5
8
"
60"
CUTOUT
17" CUTOUT
2
1
16
" TYP
19
5
8
" TYP
1
3
4
"
3
4
"
FOR LOCK OPTIONAL
USE DRILL FIXTURE TO
LOCATE HOLE
23
3
4
"
77
7
8
"
3
3
8
"
.136
.500 (12X)
.136
.500 (4X)
3
8
"
3
8
"
2
1
4
"
9
3
8
"
14
3
8
"
1
3
4
"
11
7
8
"
.136
.500 (2X)
4
7
8
"
A
3
4
"
1
8
"
1/2" (6X)
3
16
"
1/2" (6X)
DETAIL
A
SCALE
1 : 2
OVERLAY CLIP MTG HOLES
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
F
REVISED MTG HOLE LOCATIONS AND COND. AIRFLOW
DIVIDER MTG HOLES
11/8/2017
JMP
E
UPDATED CLIP MTG HOLE LOCATIONS
10/6/2017
JMP
D
REVISED WINDOW SIZE BY INCREASE CUTOUT WIDTH AND
HEIGHT BY 1-1/4" OVERALL
10/5/2017
JMP
C
ADDED HOLES FOR CONDENSER AIR DIVIDER
10/3/2017
JMP
B
UPDATED HOLE PATTERN FOR ADJUSTMENT BRKT
8/25/2017
JMP
A
INITIAL RELEASE
11/8/2016
TEC
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007917.slddrw
11/28/2016
11/08/2017
JMP
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
Ang = ±1.0°
Frac. = ±1/16
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPROVED BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007917
1007917
FOR COLUMN WINE
OVERLAY, WOOD, 6'' TOE KICK
SCALE = 1:10
SHEET 2 OF 4
A
WOOD
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 15
SCREW ZONE FOR OVERLAY TEMPLATES
3
1
16
"
3
1
16
"
3
1
4
"
23
3
4
"
66"
3"
69
1
2
"
1"
11
3
8
"
C
L
3
4
"
NOTE:
HATCH AREAS SHOULD PROVIDE ENOUGH
THICKNESS FOR WOOD SCREW FOR
OVERLAY ATTACHMENT BRACKETS.
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
F
REVISED MTG HOLE LOCATIONS AND COND. AIRFLOW
DIVIDER MTG HOLES
11/8/2017
JMP
E
UPDATED CLIP MTG HOLE LOCATIONS
10/6/2017
JMP
D
REVISED WINDOW SIZE BY INCREASE CUTOUT WIDTH AND
HEIGHT BY 1-1/4" OVERALL
10/5/2017
JMP
C
ADDED HOLES FOR CONDENSER AIR DIVIDER
10/3/2017
JMP
B
UPDATED HOLE PATTERN FOR ADJUSTMENT BRKT
8/25/2017
JMP
A
INITIAL RELEASE
11/8/2016
TEC
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007917.slddrw
11/28/2016
11/08/2017
JMP
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPROVED BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007917
1007917
FOR COLUMN WINE
OVERLAY, WOOD, 4'' TOE KICK
SCALE = 1:10
SHEET 3 OF 4
A
WOOD
NOTE:HATCHAREASSHOULD
PROVIDEENOUGHTHICKNESS
FORWOODSCREWSFOROVERLAY
ATTACHMENTBRACKET.
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
16 | perlick.com/residential
DOOR PANEL INSTALLATION
Typical panel dimensions are based on 84” (2134) nished
height with 1/8” (3) reveals. Template must be adjusted for
panels exceeding typical dimensions.
Place panel face down on a protected work surface. Aach
six clips to the back of overlay in locaons indicated in wood
overlay drawing below.
Use provided #10 x 1/2” screws to aach clips to overlay.
Overlay then slides onto door face. Aach overlay to door
adjustment brackets using remaining #10 x 1/2” screws. Once
mounted, adjust overlay to match adjacent cabinetry.
INSTALLING DOOR OVERLAY PANELS
DOOR OVERLAY PANEL ADJUSTMENT
Close the door to make adjustments to align panels and reveals.
For up and down adjustments, turn the height adjustment
screws in the top bracket (see Top of Door illustraon on page
17) in and out. Adjust the screws as needed to achieve an even
reveal on each side of the door overlay.
Once nal adjustments are made to the posion of the door
overlay, secure the overlay in place by installing the boom
overlay brackets as shown in Boom of Door illustraon below.
BOTTOM OF DOOR
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 17
TOP OF DOOR ILLUSTRATION
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
18 | perlick.com/residential
DOOR TRIM INSTALLATION
Once overlay is adjusted, mount the door trim bracket onto the
door adjustment bracket using the provided screws.
DOOR TRIM INSTALLATION
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 19
COMPLETION - GRILL INSTALLATION
GRILL INSTALLATION
Install the grill by snapping into latch catches.
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
20 | perlick.com/residential
TOE KICK CLEARANCE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Perlick CR24R-1-2R Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI