Meridian 36

Majestic Meridian 36 User manual

  • Hello! I've reviewed the specification document for the Majestic Meridian 36 Direct Vent Gas Fireplace. This document provides detailed information about the product's dimensions, framing requirements, and installation guidelines. It also covers crucial aspects like mantel projections and venting. If you have any questions about the fireplace's specifications or installation, feel free to ask!
  • What is the glass size of the Meridian 36 fireplace?
    What are the BTU/hour input ranges for the Meridian 36?
    What are the framing dimensions for the Meridian 36?
Specifications Meridian 36
Meridian 36
Direct Vent Gas Fireplace
Scan QR code for
installation manual
for nal dimensions
and requirements.
8-1/2"
[216]
2-1/16"
[52]
39-13/16"
[1011]
6" [152]
HEAT MANAGEMENT
SYSTEMS ACCESS
5-3/16"
[132]
24-3/4"
[629]
38-5/16"[973]
41" [1041]
34-1/4" [870] 33-1/2"
[851]
40-7/8"
[1038]
16"
[406]
26-7/8"
[683]
2-1/8"
[54]
41-3/4"
[1060]
8-1/2"
[216]
28-3/8" [721]
14-3/16"
[360]
11-3/16"
[284]
21-7/16"
[545]
1/2" [13]
6-3/8"
[162]
1-1/8"
[29]
6-3/8"
[162]
GAS
ACCESS
ELECTRICAL
ACCESS
ACTUAL
DIMENSIONS
FRONT WIDTH HEIGHT DEPTH GLASS SIZE BTU/HOUR INPUT
41" [1041] 40-7/8" [1038] 21-7/16" [545] 34-1/4" x 24-3/4"
[870 X 629]
16,000 - 30,000 BTUs (NG)
17,000 - 28,000 BTUs (LP)
TOP VIEW
FRONT VIEWLEFT SIDE RIGHT SIDE
FRAMING
DIMENSIONS
FRONT WIDTH HEIGHT DEPTH WEIGHT
42" [1067] 40-1/8" [1019] 22" [559] 163 LBS [74 KGS]
42"
[1067]
DVP pipe 10" [254]
SLP pipe 8-5/8" [219]
40-1/8"
[1019]
22" [559]
Adjust framing dimensions for interior
chase sheathing (such as sheetrock)
TOP VENT
ONE 900 ELBOW
51"
[1295]
51" [1295]
42"
[1067]
72" [1829]
1/2"
[13]
17-3/4"
[451]
Reference install manual for additional venting scenarios
BASIC CORNER INSTALLATION
Specifications Meridian 36
COMBUSTIBLE MANTEL PROJECTIONS
5
10
11
12
2-1/2
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
3
25
18
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2"
Note:
All measurements
in inches.
Note: Measurement is taken from top of the opening,
NON-COMBUSTIBLE MANTEL PROJECTIONS
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
25
18
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2"
Note: All
measurements
in inches.
Note: Measurement is taken from top of the opening,
COMBUSTIBLE MANTEL LEGS OR WALL
PROJECTIONS
Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
AB
INTERIOR WALL
TOP VIEW
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
If A minimum is ____, then B maximum is_____.
AInches2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Millimeters62 87 113 138 164 189
B
Inches12345
Millimeters25 51 76 102 127
NON-COMBUSTIBLE MANTEL LEGS OR WALL
PROJECTIONS
Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
If A minimum is ____, then B maximum is_____.
A
Inches
0-7-7/16 7-7/16
Millimeters
0-189 189
B
Inches
6
Millimeters
152
A
B
INTERIOR WALL
TOP VIEW
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
6 IN.
If using heat management please refer to the replace
installation manual for framing guidelines and reduced
mantel clearances. Additional information on venting,
TV clearances, nishing requirements, fronts, etc can be
found in the installation and owner's manual
Specifications Meridian 36
EXTERIOR CHASE MINIMUM HEIGHT REQUIREMENTS WALL PENETRATION
42-3/4"
*
[1086]
10" 12"
* Shows center of vent framing hole for top or rear venting. The center
of the hole is one (1) in. (25 mm) above the center of the horizontal
vent pipe.
DO NOT PACK VENT FRAMING HOLE WITH INSULATION
OR OTHER MATERIAL.
27-7/8"
*
[708]
41-3/4"
[1060]
26-7/8"
[683]
10" 12"
3 IN. MIN.
* NOTE: If overhang (A) is less than 2 inches, clearance from top of
termination cap to bottom of overhang (B) may be 0 inches.
A - Measured from back of vent cap to end of overhang
B - Measured from bottom of overhang to top of termination cap
Vinyl Siding Shield (TRAP-VSS) Information
TRAP-VSS required if overhang (A) is greater than 3 inches but less
than 5 inches and B dimension is less than 18 inches.
TRAP-VSS recommended if either of the below is true:
- Overhang (A) is less than 5 inches (to combat water infiltration)
- A vinyl overhang is present
A
B*
PRODUCT LISTING CODES
US ANSI Z21.88-2019
CAN CSA 2.33-2019
UL307B
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of re and potential injury.
MAJ/Meridian36_0623
Majestic — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044
877-486-9123 | majesticproducts.com | majesticproducts.ca
/