Supermicro SSE-X3648S, SSE-X3648SR Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Supermicro SSE-X3648S Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SSE-X3648S Switch
SSE-X3648SR Switch
Installation Manual
Revison 1.0
SSE-X3648S/SSE-X3648SR Switch Installation Manual
ii
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The
vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no
commitment to update or to keep current the information in this manual, or to notify any person or
organization of the updates. Please Note: For the most up-to-date version of this manual, please see
our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described
in this manual at any time and without notice. This product, including software and documentation, is the
property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction
of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE
THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE,
SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF
REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE,
SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara
County in the State of California, USA. The State of California, County of Santa Clara shall be the
exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not
exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital
device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the manufacturer’s instruction manual, may cause harmful interference with radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference,
in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials
: This Perchlorate warning
applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate
WARNING: HANDLING OF LEAD SOLDER MATERIALS USED IN THIS
PRODUCT MAY EXPOSE YOU TO LEAD, A CHEMICAL KNOWN TO
THE STATE OF CALIFORNIA TO CAUSE BIRTH DEFECTS AND
OTHER REPRODUCTIVE HARM.
SSE-X3648S/SSE-X3648SR Installation Manual
Release Date: June 24, 2015
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy
any part of this document.
Information in this document is subject to change without notice. Other products and companies referred
to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2015 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
iii
Preface
About this Manual
This manual is written for professional system integrators, Information Technology
professionals, service personnel, technicians and network administrators who are
responsible for installing and setting up network equipment; consequently, it assumes a
basic working knowledge of LANs (Local Area Networks). It provides information for the
installation and use of the Supermicro's SSE-X3648S and SSE-X3648SR switches.
Installation and maintenance should be performed by experienced professionals only.
Manual Organization
Chapter 1: Introduction
The first chapter provides an introduction to the switch.
Chapter 2: System Safety
You should familiarize yourself with this chapter for a general overview of safety
precautions that should be followed when using the switch.
Chapter 3: Installation Requirements
This chapter covers installation requirements, notices and security warnings for the
switches.
Chapter 4: Device Installation
Use this chapter for installation of the switches and connecting them to your systems.
SSE-X3648S Switch User’s Guide
iv
Notes
v
Table of Contents
Table of Contents
Chapter 1 Introduction.......................................................................1-1
1-1 Features and Benefits......................................................................1-1
1-2 Description of Hardware...................................................................1-1
Front Panel .............................................................................................1-1
Back Panel..............................................................................................1-2
1-3 Status LEDs .......................................................................................1-2
1-4 Port Description.................................................................................1-4
1-5 Power Supply Module.......................................................................1-5
460W Power Module...............................................................................1-5
1-6 Fan Module........................................................................................1-6
1-7 System Specifications.......................................................................1-7
Chapter 2 Standardized Warning Statements.....................2-1
2-1 About Standardized Warning Statements......................................2-1
Warning Definition...................................................................................2-1
Installation Instructions ...........................................................................2-3
Circuit Breaker........................................................................................2-4
Power Disconnection Warning................................................................2-5
Equipment Installation.............................................................................2-6
Restricted Area.......................................................................................2-7
Battery Handling .....................................................................................2-9
Comply with Local and National Electrical Codes.................................2-10
Product Disposal...................................................................................2-11
Power Cable and AC Adapter ..............................................................2-12
Chapter 3 Installation Requirements........................................3-1
3-1 Environmental Requirements .........................................................3-1
3-2 Dust and Particles.............................................................................3-1
3-3 Temperature and Humidity...............................................................3-2
3-4 Power Supply.....................................................................................3-3
3-5 Preventing Electrostatic Discharge Damage................................3-3
3-6 Anti-interference................................................................................3-3
3-7 Rack Configuration ...........................................................................3-4
3-8 Installation Notice..............................................................................3-4
3-9 Security Warnings.............................................................................3-5
SSE-X3648S/SSE-X3648SR Switch Installation Manual
vi
Chapter 4 Device Installation ........................................................4-1
4-1 Installation Preparation.....................................................................4-1
Verify the Package Contents...................................................................4-1
Required Tools and Utilities ....................................................................4-1
4-2 Device Installation.............................................................................4-2
Installing the Switch in a Shelf Rack.......................................................4-2
Installing the Switch into a Rail Rack......................................................4-3
Installing the Power Supply Module........................................................4-4
Installing the Fan.....................................................................................4-5
Connecting the Console..........................................................................4-6
SFP/SFP+/QSFP+ Transceiver Installation............................................4-6
Copper Cable/Fiber Cable Connection...................................................4-7
AC Power Supply Connection.................................................................4-9
Grounding Cable Connection................................................................4-10
Checking the Switch .............................................................................4-10
1-1
Chapter 1: Introduction
Chapter 1
Introduction
The SSE-X3648S and SSE-X3648SR switches are the latest generation of 10Gb
Ethernet routing switches from Supermicro. They are based on 10Gb switching
technology and are designed for aggregating connectivity to 40Gb servers in data
centers – or for 40Gb access to backbone networks. Preloaded with Open Networking
Installation Environment (ONIE), they are particularly suitable for use in an Open
Networking environment.
The SSE-X3648S and SSE-X3648SR switches with advanced intelligent and secure
features, can serve ideally as a distribution layer switch for campus networks, enterprise
networks and HP networks; as well as a core layer switch for small to medium-sized
networks.
1-1 Features and Benefits
Various Interfaces – The SSE-X3648S/SSE-X3648SR switches provide 48 10Gb
SFP+ and 6 40Gb QSFP+ ports. Each QSFP+ port can be split into 4 10Gb SFP+
ports.
Support 10Gb Ethernet – 10Gb Ethernet adopts full-duplex technology instead of
the half-duplex CSMA/CD protocol. 10Gb Ethernet can be deployed in star or ring
topologies. With 10Gb Ethernet, the SSE-X3648S/SSE-X3648SR switches provide
broad bandwidth and powerful processing capacity. Using the SSE-X3648S/
SSE-X3648SR switches, users can simplify network structures and reduce the
overall cost of building a network.
1-2 Description of Hardware
Front Panel
The front panel descriptions of the SSE-X3648S/SSE-X3648SR switches are shown in
the following table.
The front panel of the SSE-X3648S/SSE-X3648SR switches is shown below:
Table 1-1. Front Panel Descriptions of the SSE-X3648S/SSE-X3648SR Switch
Type SFP+ Port QSFP+ Port
SSE-X3648S 48 6
SSE-X3648S/SSE-X3648SR Switch Installation Manual
1-2
Back Panel
The SSE-X3648S/SSE-X3648SR switches provides an RJ-45 serial console port in the
rear of the switch. Users perform the local and telnet configuration through this port.
The back panel of the SSE-X3648S/SSE-X3648SR switch also includes two redundant
hot-swappable AC power supply modules, four fans and one rear panel card.
The console port supports asynchronous mode. To set this up just set the data bit as 8,
the stop bit as 1, the parity bit as none, and the default baud rate as 115,200bps.
Cautions:
1. The USB port on the rear panel card only supports data transmission. It does not
support power supply over USB.
2. The rear panel card does not support hot plug.
3. Replacement of the rear panel card must be done by a professional.
1-3 Status LEDs
There are indicator LEDs on the front panel of the SSE-X3648S/SSE-X3648SR
switches. There are 48 SFP+ Port Indicator LEDs, 24 QSFP+ Port Indicator LEDs, two
Power Supply Indicator LEDs, and a System Automatic Diagnosis LED. These LEDs
are described below in Table 1-3, Table 1-4 and Table 1-5.
Figure 1-1. Front Panel of the SSE-X3648S/SSE-X3648SR Switches
Table 1-2. Rear Panel Descriptions of the SSE-X3648S/SSE-X3648SR Switch
Type
10/100/1000Base-T
Ethernet Port
Console Port
USB2.0
Interface
SSE-X3648S 1 1 1
Figure 1-2. Back Panel of the SSE-X3648S/SSE-X3648SR Switch
SFP+ Ports QSFP+ Ports
Power
Supply
Console Ports
Fans
Power
Supply
Fans
USB Port
1-3
Chapter 1: Introduction
Table 1-3. Front Panel Status LEDs
Indicator
Light
Front Panel
Sign
State Description
Power Supply
Indicator Light
P-1/P-2
Green light always on Power supply module operating normally.
No Light No power supply or error.
System Status
Indicate Led
Start
Green light always on
The system is powered on and running
normally.
No Light The system is powered off.
Table 1-4. Rear Panel Status LEDs
Indicator
Light
Rear Panel
Sign
State Meanings
Fan Module
Indicator Light
Fan1/Fan2/
Fan3/Fan4
Green Light Always On Fan module is operating normally.
Red Light Always On No fan module or fan speed is 0
No Light Fan module is powered off
Table 1-5. Port Indicator LEDs
Indicator Light Panel Sign State
Ethernet Port Link
Light (Left)
Green Light Wink The port is transmitting data.
Put Out There is no data transmitting on the port.
Ethernet Port Activity
Light (Right)
Yellow Light Always On The port is configured at 10m/100M speed
Green Light Always On The port is configured at 1000M speed
Put Out No connection or fail to connect.
Indicator Light Of
SFP+ Port
Green Light Always On The port is connected at 10G.
Amber Light Always On The port is connected at 1G.
Wink The port is transmitting data.
Put Out No connection or fail to connect.
Indicator Light Of
QSFP+ Port
Green Light Always On The port is connected at 40G.
Amber Light Always On The port is connected at 4X10G.
Wink The port is transmitting data.
Red Light Always On There is a fault on the port.
Put Out No connection or fail to connect.
SSE-X3648S/SSE-X3648SR Switch Installation Manual
1-4
1-4 Port Description
The SSE-X3648S/SSE-X3648SR provides 48 10Gb SFP+ ports and 6 40Gb QSFP+
ports.
The following SFP transceivers are supported:
SFP-SX-L transceiver
SFP-LX-L transceiver
SFP-LX-20-L 20-km transceiver
SFP-LX-40 40-km mid distance transceiver
SFP-LH-70-L 70-km long distance transceiver
SFP-LH-120-L 120-km long distance transceiver
SFP-GT 1000 Base-T SFP interface cards module
Table 1-6 describes the ports.
The SSE-X3648S/SSE-X3648SR switch provides six QSFP+ ports and supports
QSFP+ cabling. Users can select from the cables in the Table 1-7 according to their
need.
Table 1-6. SSE-X3648S/SSE-X3648SR Switch Port Description
Port Mode Spec
RJ-45 Port
10/100/1000Mbps Auto Negotiation
MDI/MDI-X Cable Mode Auto Negotiation
QSFP+
40GBASE-CR4 Transceiver, Copper, 7m
40GBASE-SR4 Transceiver, 850nm, MMF, OM3/OM4, 100m
Table 1-7. Cables Supported by the SSE-X3648S/SSE-X3648SR Switch
Type Manufacturer Model Standard
40G QSFP+ Cable Tyco 2053638-3 30AWG, 3.0m
QSFP+ to 4Xsfp+
Cable
Amphenol 582410007 30AWG, 3.0m
QSFP to QSFP Cable
Molex
747571051 30AWG, 0.5m
747571101 30AWG, 1.0m
747571301 30AWG, 3.0m
1-5
Chapter 1: Introduction
1-5 Power Supply Module
460W Power Module
Figure 1-3 shows the power supply module for the SSE-X3648S/SSE-X3648SR switch.
The SSE-X3648S/SSE-X3648SR switch has two power supply modules, thus providing
redundancy. It provides airflow front to back (SSE-X3648S) or airflow back to front
(SSE-X3648SR).
The maximum power is 460W, while the input is 100VAC~240VAC, and the output is
12V +/- 5%. There is a fan and a handle for inserting or removing the module on the
back of the power supply. The power supply module supports hot-plug replacement.
Figure 1-3. 460W Power Supply Module
SSE-X3648S/SSE-X3648SR Switch Installation Manual
1-6
1-6 Fan Module
Figure 1-4 shows the fan module for the SSE-X3648S/SSE-X3648SR switch.
The SSE-X3648S/SSE-X3648SR switch has four fan modules in its standard
configuration. The rotation speed of the fan self-adjusts to adapt to system temperature,
and provides airflow front to back (SSE-X3648S) and airflow back to front
(SSE-X3648SR).
Cautions:
1. Different airflow fan modules cannot be mixed.
2. Airflow for power modules must be the same as that used for fan modules.
Figure 1-4. Fan Module
1-7
Chapter 1: Introduction
1-7 System Specifications
System specifications are shown in Table 1-8 below.
Table 1-8. System Specifications
Specification Description
Dimensions(W * H * D) (mm) 433.8 * 44 * 550
Weight 10.133 kg
Fixed Port 48 SFP+ ports; 6 QSFP+ ports
Management Port 1 RJ-45 serial console port
Power Input 100~240VAC(50~60Hz) 2.8A~5.6A
System Power Consumption <400W
Operating Temperature 0°C~40°C
Storage Temperature -40°C~75°C
Operating Relative Humidity 10%~90%, no condensate
Storage Relative Humidity 5%~95%, no condensate
SSE-X3648S/SSE-X3648SR Switch Installation Manual
1-8
Notes
2-1
Chapter 2: Standardized Warning Statements
Chapter 2
Standardized Warning Statements
2-1 About Standardized Warning Statements
The following statements are industry standard warnings, provided to warn the user of
situations which have the potential for bodily injury. Should you have questions or
experience difficulty, contact Supermicro's Technical Support department for assistance.
Only certified technicians should attempt to install or configure components.
Read this appendix in its entirety before installing or configuring components in the
Supermicro chassis.
These warnings may also be found on our web site at http://
www.supermicro.com/about/policies/safety_information.cfm.
Warning Definition
Warning!
This warning symbol means danger. You are in a situation that could cause
bodily injury. Before you work on any equipment, be aware of the hazards
involved with electrical circuitry and be familiar with standard practices for preventing
accidents.
此警告符号代表危险。
您正处于可能受到严重伤害的工作环境中在您使用设备开始工作之前必须充分意识到
触电的危险并熟练掌握防止事故发生的标准工作程序请根据每项警告结尾的声明号码
找到此设备的安全性警告说明的翻译文本。
此警告符號代表危險。
您正處於可能身體可能會受損傷的工作環境中在您使用任何設備之前請注意觸電的危
且要熟悉預防事故發生的標準工作程序請依照每一注意事項後的號碼找到相關
翻譯說明內容。
SSE-X3648S/SSE-X3648SR Switch Installation Manual
2-2
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu
Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren
elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen
vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen
Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de
manipular cualquier equipo, considere los riesgos de la corriente eléctrica y
familiarícese con los procedimientos estándar de prevención de accidentes. Al final de
cada advertencia encontrará el número que le ayudará a encontrar el texto traducido en
el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation
pouvant entraîner des blessures ou des dommages corporels. Avant de travailler sur un
équipement, soyez conscient des dangers liés aux circuits électriques et
familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents.
Pour prendre connaissance des traductions des avertissements figurant dans les
consignes de sécurité traduites qui accompagnent cet appareil, référez-vous au numéro
de l'instruction situé à la fin de chaque avertissement.
CONSERVEZ CES INFORMATIONS.
ןןונקת תורהצהאהרהז
ןה תואבה תורהצהא ינפמ שמתשמה תא ריהזהל תנמ לע ,היישעתה ינקת יפ לע תורהז הלבח
ה וא תולאש שיו הדימב .תירשפא תיזיפי ,יהשלכ היעבב תולקתרוציל שי הכימת תקלחמ םע רשק
רידגהל וא ןיקתהל םיאשר דבלב םיכמסומ םיאנכט רקימרפוס לש תינכט תאה .םיביכר
אורקל שי .ורקימרפוס יזראמב םיביכרה תרדגה וא תנקתה ינפל ואולמב חפסנה תא
. ﻲﻓ ﻚﻧا نأ ﻦﻜﻤﯾ ﺔﻟﺎ ﻲﻓ ﺐﺒﺴﺘﺗ ﺔﺑﺎﺻا ﺔﯾﺪﺴﺟ ﺰﻣﺮﻟا اﺬھ ﻲﻨﻌﯾ ﺮﻄﺧ !ﺮﯾﺬﺤﺗ
نأ ﻞﺒﻗ يأ ﻰﻠﻋ ﻞﻤﻌﺗ تاﺪﻌﻣ،ﻢﻠﻋ ﻰﻠﻋ ﻦ ﻦﻋ ﺔﻤﺟﺎﻨﻟا ﺮطﺎﺨﻤﻟﺎﺑ ﺮﺋاوﺪﻟا
ﺔﯿﺋﺎﺑﺮﮭﻜﻟا
ﻛوﺔﯾارد ﻰﻠﻋ ﻦ رﺎﻤﻤﻟﺎﺑتﺎﺳ ﺔﯿﺋﺎﻗﻮﻟا ﻊﻨﻤعﻮﻗو يأثداﻮﺣ
ﻢﻗر مﺪﺨﺘﺳا نﺎﯿﺒﻟا صﻮﺼﻨﻤﻟا ﺔﯾﺎﮭﻧ ﻲﻓ ﺮﯾﺬﺤﺗ ﻞﻛ رﻮﺜﻌﻠﻟ ﺎﮭﺘﻤﺟﺮﺗ
2-3
Chapter 2: Standardized Warning Statements
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwings symbool betekent gevaar. U verkeert in een situatie die lichamelijk
letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich
bewust te zijn van de bij een elektrische installatie betrokken risico's en dient u op de
hoogte te zijn van de standaard procedures om ongelukken te voorkomen. Gebruik de
nummers aan het eind van elke waarschuwing om deze te herleiden naar de
desbetreffende locatie.
BEWAAR DEZE INSTRUCTIES
Installation Instructions
Warning!
Read the installation instructions before connecting the system to the power
source.
警告
将此系统连接电源前 , 请先阅读安装说明。
警告
將系統與電源連接前,請先閱讀安裝說明。
Warnung
Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen
lesen.
¡Advertencia!
Lea las instrucciones de instalación antes de conectar el sistema a la red de
alimentación.
Attention
Avant de brancher le système sur la source d'alimentation, consulter les directives
d'installation.
אורקל שי רוקמל תכרעמה רוביח ינפל הנקתה תוארוה תאחתמ.
SSE-X3648S/SSE-X3648SR Switch Installation Manual
2-4
Waarschuwing
Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron aansluit.
Circuit Breaker
Warning!
This product relies on the building's installation for short-circuit (overcurrent)
protection. Ensure that the protective device is rated not greater than: 250 V,
20 A.
警告
此产品的短路 ( 过载电流 ) 保护由建筑物的供电系统提供 , 确保短路保护设备的额定电流
不大于 250V,20A
警告
此產品的短路 ( 過載電流 ) 保護由建築物的供電系統提供 , 確保短路保護設備的額定電
流不大於 250V,20A。
Warnung
Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw.
Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der
Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt.
¡Advertencia!
Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del
edificio. Asegúrese de que el dispositivo de protección no sea superior a: 250 V, 20 A.
Attention
Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend
de l'installation électrique du local. Vérifiez que le courant nominal du dispositif de
protection n'est pas supérieur à :250 V, 20 A.
ﻟا تادﺎﺷرإ ﺮﻗاﺐﯿﻛﺮﺘ ﻞﯿﺻﻮﺗ ﻞﺒﻗ ﻰﻟإ مﺎﻈﻨﻟا ﺔﻗﺎﻄﻠﻟ رﺪﺼﻣ
לע ךמתסמ הז רצומנגהה תעינמל םינבמב תנקתומה יכ אדוול שי .ילמשח רצק
רצקה ינפמ ןגמה רישכמה ילמשחהמ רתוי אל אוה-250 V, 20 A
2-5
Chapter 2: Standardized Warning Statements
Waarschuwing
Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische
installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan
220V, 20A.
Power Disconnection Warning
Warning!
The system must be disconnected from all sources of power and the power
cord removed from the power supply module(s) before accessing the chassis
interior to install or remove system components.
警告
在你打开机箱并安装或移除内部器件前 , 必须将系统完全断电 , 并移除电源线。
警告
在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。
Warnung
Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt
sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es auf den
Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder zu
entfernen.
ﺞﺘﻨﻤﻟا اﺬھ ﻰﻠﻋ ﺪﻤﺘﻌﯾ تاﺪﻌﻣ ﺔﯾﺎﻤﺤﻟا ةﺮﯿﺼﻘﻟاﺮﺋاوﺪﻟا ﻦﻣ ﺎﮭﺘﯿﺒﺜﺗ ﻢﺗ ﻲﺘﻟا ﻲﻓ
ﻰﻨﺒﻤﻟا
20A, 250V : ﻦﻣ ﺪﻛﺄﺗ نأ ﻢﯿﯿﻘﺗ زﺎﮭﺠﻟا ﻟاﻲﺋﺎﻗﻮ ﺲﯿﻟ ﻣ ﺮﺜﻛأ
SSE-X3648S/SSE-X3648SR Switch Installation Manual
2-6
¡Advertencia!
El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico
quitado de los módulos de fuente de alimentación antes de tener acceso el interior del
chasis para instalar o para quitar componentes de sistema.
Attention
Le système doit être débranché de toutes les sources de puissance ainsi que de son
cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour installer ou
enlever des composants de systéme.
Waarschuwing
Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of
verwijderen van systeem onderdelen, dient u alle spanningsbronnen en alle
stroomkabels aangesloten op de voeding(en) van de behuizing te verwijderen.
Equipment Installation
Warning!
Only trained and qualified personnel should be allowed to install, replace, or
service this equipment.
警告
只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。
警告
只有經過受訓且具資格人員才可安裝、更換與維修此設備。
יילמשח קותינ ינפמ הרהזא
!הרהזא
למשחה תורוקמ לכמ תכרעמה תא קתנל שי ריסהל שיו קפסהמ ילמשחה לבכ תא
נקתה ךרוצל זראמה לש ימינפה קלחל השיג ינפלת רסה ואת .םיביכר
ﻞﺼﻓ ﺐﺠﯾ مﺎﻈﻨﻟا ﻊﯿﻤﺟ ﻦﻣردﺎﺼﻣ ﺔﻗﺎﻄﻟا ﺔﻟازإو ءﺎﺑﺮﮭﻜﻟا ﻚﻠﺳ ﻦﻣ ةﺪﺣو داﺪﻣا
ﺔﻗﺎﻄﻟا ﻞﺒﻗ
ﻰﻟإ لﻮﺻﻮﻟا ﺔﯿﻠﺧاﺪﻟا ﻖطﺎﻨﻤﻟا ﻞﻜﯿﮭﻠ ﺔﻟازإ وأ ﺖﯿﺒﺜﺘﻟ تﺎﻧﻮﻜﻣ زﺎﮭﺠﻟا
/