Desa VT36ENR1 User manual

Category
Fireplaces
Type
User manual
NATURAL GAS “TUDOR MODEL (V)T32EN, (V)T36EN SERIES
PROPANE/LP GAS TUDOR MODEL (V)T32EP, (V)T36EP SERIES
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage. Refer
to this manual for correct installation and
operational procedures. For assistance or
-
staller, service agency, or the gas supplier.
Installation and service must be performed

gas supplier.
This appliance is only for use with the type
of gas indicated on the rating plate. This ap-
pliance is not convertible for use with other

This appliance may be installed in an after-

(mobile) home, where not prohibited by state
or local codes.

from the manufacturer.
WARNING: If the information in this manual is

result causing property damage, personal
injury, or loss of life.
FOR YOUR SAFETY

vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call

DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
INSTALLER: Leave this manual with the ap-
pliance
     
reference.
For more information, visit www.desatech.com
www.desatech.com
108860-01D2
SAFETY INFORMATION
WARNING: This product contains and/or generates

cancer or birth defects, or other reproductive harm.
IMPORTANT: Read this owners manual carefully and
completely before trying to assemble, operate, or service

       

 
to death!
This replace must be installed by a qualied (certied or licensed)
service person. It has a sealed gas combustion chamber that uses
a coaxial pipe (pipe within a pipe and having the same center)
venting system. It brings in fresh air for combustion through the
outer pipe and combustion gases are exhausted through the inner
pipe. If the glass door assembly and venting pipe are not properly
seated, connected, and sealed, carbon monoxide leakage (spillage)
can occur.
   Early signs of carbon monoxide
poisoning resemble the u, with headaches, dizziness, or nausea.
If you have these signs, the replace may not have been installed
properly. Get fresh air at once! Have replace inspected and ser-
viced by a qualied service person. Some people are more affected
by carbon monoxide than others. These include pregnant women,
people with heart or lung disease or anemia, those under the inu-
ence of alcohol, and those at high altitudes.
Propane/LP gas and natural gas are both odorless. An odor-making
agent is added to each of these gases. The odor helps you detect
a gas leak. However, the odor added to these gases can fade. Gas
may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this replace.
-
trols can be dangerous.
1. This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases unless a certied kit is used.
2. For propane/LP replace, do not place propane/LP supply
tank(s) inside any structure. Locate propane/LP supply tank(s)
outdoors. To prevent performance problems, do not use pro-
pane/LP fuel tank of less than 100 lbs. capacity.
3. If you smell gas
shut off gas supply
do not try to light any appliance
do not touch any electrical switch; do not use any phone in
your building
immediately call your gas supplier from a neighbors phone.
Follow the gas supplier's instructions
if you cannot reach you gas supplier, call the re department.
4. Never install the replace
in a recreational vehicle
in windy or drafty areas where curtains or other combustible
(ammable) objects can make contact with the replace front
in high trafc areas
5. This replace reaches high temperatures. Keep children and
adults away from hot surfaces to avoid burns or clothing igni-
tion. Fireplace will remain hot for a time after shutdown. Allow
surfaces to cool before touching.
6. Carefully supervise young children when they are in the room
with replace.
7. Do not modify this replace under any circumstances. Any
parts removed for servicing must be replaced prior to operating
replace.
8. Turn replace off and let cool before servicing, installing, or
repairing. Only a qualied service person should install, ser-
vice, or repair this replace. Have replace inspected annually
by a qualied service person.
9. You must keep control compartments, burners, and circulating
air passages clean. More frequent cleaning may be needed due
to excessive lint and dust from carpeting, bedding material, etc.
Turn off the gas valve and pilot light before cleaning replace.
10. Have venting system inspected annually by a qualied service
person. If needed, have venting system cleaned or repaired. See
Cleaning and Maintenance, page 25.
11. Keep the area around your replace clear of combustible ma-
terials, gasoline, and other ammable vapor and liquids. Do
not run replace where these are used or stored. Do not place
items such as clothing or decorations on or around replace.
TABLE OF CONTENTS
Safety Information ........................................................................2
Product Identication ....................................................................3
Local Codes..................................................................................3
Product Features ..........................................................................3
Pre-Installation Preparation ..........................................................4
Location of Termination Cap .........................................................6
Venting Installation Instructions ....................................................7
Fireplace Installation...................................................................14
Wiring Diagram ...........................................................................22
Operating Fireplace ....................................................................23
Inspecting Burners......................................................................24
Cleaning and Maintenance .........................................................25
Troubleshooting ..........................................................................26
Replacement Parts .....................................................................28
Service Hints ..............................................................................28
Technical Service........................................................................28
Specications .............................................................................28
Accessories ................................................................................29
Illustrated Parts Breakdown and Parts List.................................30
Warranty Information ................................................... Back Cover
www.desatech.com
108860-01D 3
12. Do not use this replace to cook food or burn paper or other
objects.
13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.)
in this replace. Use only the gas type indicated on replace
nameplate.
14. This appliance, when installed, must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
15. Do not use replace if any part has been exposed to or under
water. Immediately call a qualied service person to arrange
for replacement of the unit.
16. Do not operate replace if any log is broken.
17. Do not use a blower insert, heat exchanger insert, or other ac-
cessory not approved for use with this replace.
18. Do not operate replace with glass door removed, cracked, or
broken.
19. Provide adequate clearances around air openings.
PRODUCT IDENTIFICATION
SAFETY INFORMATION
Continued
Figure 1 - Tudor Direct-Vent Fireplace with Electronic Ignition
LOCAL CODES
Install and use replace with care. Follow all local codes. In the
absence to local codes, use the current National Fuel Gas Code
ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal-
lation Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT FEATURES
These are a few facts that can help you understand and enjoy your
direct-vent replace:
The venting system may be routed to the outside of your home
in several ways. It may vent through the roof (vertical) or it may
vent to an outside/exterior wall (horizontal). The vent pipe instal-
lation is very important to allow for proper operation. You must
follow the venting instructions very carefully for either vertical
or horizontal applications.
This replace may be installed in any room of your house
provided all local codes and these installation instructions are
followed.
The blower requires electricity if installed and if you plan to
install the blower at a later date, do not forget to wire the outlet
at the bottom of the replace when framing.
The electronic ignition creates spark to ignite the pilot light. It
does not require any matches, batteries or any other sources of
ignition to light the pilot.
Each time you turn on your replace, you may notice some
amount of condensation on the inside of the replace glass. This
is normal and will disappear after 10-20 minutes of operation.
Your direct-vent gas replace system (replace and venting) is a
balanced and sealed gas operating unit. It requires approximately 10-
20 minutes of operating time before theame pattern stabilizes.
Glass
Door
Assembly
Blower Switch
(Optional Installation)
Control
Valve
Log
Set
Grate
Assembly
Lava
Rock
Glowing
Embers
Upper Louver
Panel
Lower
Louver
Panel
Flue Collar
Nailing
Flange
ON/OFF/REMOTE Switch
(Optional Installation)
www.desatech.com
108860-01D4
PRE-INSTALLATION
PREPARATION

Determine the safest and most efcient location for your DESA
direct-vent replace. Make sure that rafters and wall studs are not
in the way of the venting system. Choose a location where the heat
output is not affected by drafts, air conditioning ducts, windows
or doors. Figure 2 shows some common locations. Be aware of all
restrictions and precautions before deciding the exact location for
your replace and termination cap.
When deciding the location of your replace, follow these rules:
Do not connect this replace venting to a chimney ue serving
a separate solid-fuel burning replace or appliance.
Due to high temperatures, do not locate this replace in high traf-
c areas, windy or drafty areas, or near furniture or draperies.
Proper clearances must be maintained.
If your replace is to be installed directly on carpeting, vinyl tile,
or any combustible material other than wood, it must be installed
on a metal or wood panel extending the full width and depth of
the replace. See Figure 3.
Your replace is designed to be used in zero clearance instal-
lations. Wall or framing material can be placed directly against
any exterior surface on the back, sides, or top of your replace,
except where standoff spacers are integrally attached. If standoff
spacers are attached to your replace, these spacers can be placed
directly against wall or framing material. See framing details on
page 5.
If you plan on installing a television or entertainment center re-
cessed above your replace, it is recommended that you maintain
a minimum 18" above top of louver opening.
When locating termination cap, it is important to observe the
minimum clearances shown in Figure 7, page 6.
If recessing into a wall, you can avoid extra framing by position-
ing your replace against an already existing framing member.
Do not recess termination cap into a wall or siding.
You may paint the termination cap with 450º F (232º C) heat-
resistant paint to coordinate with the exterior nish.
There must not be any obstruction such as bushes, garden sheds,
fences, decks, or utility buildings within 24" from the front of
the termination cap.
Do not locate termination cap where excessive snow or ice build up
may occur. Be sure to clear vent termination area after snow falls to
prevent accidental blockage of venting system. When using snow
blowers, do not direct snow towards vent termination area.
Fireplace size D x FW x RW
32" 16
5
/8" 34
3
/8" 22
1
/2"
36" 21
1
/8" 41" 29"
Figure 2 - Common Fireplace Locations
Flush with a wall
Through exterior wall
enclosed in a chase
Corner
installation
Figure 3 - Fireplace Bottom Dimensions
D
RW
FW

Minimum clearances to combustibles for the replace are as follows:
Back, and sides 0"/mm
Perpendicular walls 6" (152 mm)
Floor 0"/mm
Ceiling to louver opening 42" (1067 mm)
Front 36" (914 mm)
Top 0"/mm
Vent (See venting instructions for
specic venting clearances.)
Combustible material with a maximum thickness of 5/8" may be
ush with the top front of replace .
-

-
mary heat source. If you have a central heating system,
you may run system’s circulating blower while using

the house.
www.desatech.com
108860-01D 5
B
C
A
FRAMING AND FINISHING
Figure 4 shows typical framing of this replace. Figure 5 shows fram-
ing for corner installation. All minimum clearances must be met.
For available accessories for this replace, see Accessories on page
29. If you are using a separate combustible mantel piece, refer to
Figure 6 for proper installation height. You can install noncombustible
mantels at any height above the replace. Note: Noncombustible
mantels may discolor!
PRE-INSTALLATION
PREPARATION
Continued
Figure 4 - Framing Clearances for Installation Against an
Exterior Wall
32" Models 36" Models
A 32
3
/8" 36
1
/8"
B 34
5
/8" 41
1
/4"
C 19" 23
1
/2"
C
B
A
D
E
F
G
Top of Louver Opening
3
2
1
4
5
6
7
Wall
A
B
E
F
G
H
D
C
Nailing Tabs
Figure 5 - Framing Clearances for Corner Installation
Ref. Mantel Ref. Mantel from Top
Depth of Louver Opening
1 14" A 16"
2 12" B 14"
3 10" C 12"
4 8" D 10"
5 6" E 8"
6 4" F 6"
7 2" G 4"
32" Models 36" Models
A 28
1
/2" 35
3
/4"
B 13
5
/8" 15"
C 39
3
/8" 49
5
/8"
D 9
1
/2" 10
3
/8"
E 9
7
/8" 13
3
/4"
F 34
3
/8" 41"
G 34
5
/8" 41
1
/4"
H 54
1
/8" 68
1
/2"
Figure 6 - Clearances for Combustible Mantels
www.desatech.com
108860-01D6
Fixed
Closed
Openable
Fixed
Closed
Openable
V
V
V
V
V
V
V
V
X
X
V
X
G
G
J
F
B
B
K
N
H
I
A
N
E
L
D
B
M
A
C
B
V
V
A
G
G
B
TERMINATION CAP
AIR SUPPLY INLET
GAS METER RESTRICTED AREA
(TERMINATION PROHIBITED)
A = clearance above grade, veranda, porch, deck, or balcony
[*12" (30.5 cm) minimum]
B = clearance to window or door that may be opened
[12" (30.5 cm) minimum]
C = clearance to permanently closed window [minimum 12" (30.5 cm)
recommended to prevent condensation on window]
D = vertical clearance to ventilated soffit located above the terminal
within a horizontal distance of 24" (61cm) from the
center-line of the terminal [18" (45.7 cm) minimum]
E = clearance to unventilated soffit [12" (30.5 cm) minimum]
F = clearance to outside corner (see below)
G = clearance to inside corner (see below)
H = *not to be installed above a meter/regulator assembly within
36" (91.4 cm) horizontally from the center-line of the regulator
I = clearance to service regulator vent outlet [*72" (182.9 cm)
minimum]
J = clearance to non-mechanical air supply inlet to building or the
combustion air inlet to any other fireplace [*12" (30.5 cm)
minimum]
K = clearance to a mechanical air supply inlet [*72" (182.9 cm)
minimum]
L = † clearance above paved side-walk or a paved driveway located on
public property [*84" (213.3 cm) minimum]
M = clearance under veranda, porch, deck [*12" (30.5 cm) minimum ‡]
N = clearance above a roof shall extend a minimum of 24" (61 cm)
above the highest point when it passes through the roof surface and
any other obstruction within a horizontal distance of 18" (45.7 cm)
vent shall not terminate directly above a side-walk or paved driveway which is located between two
single family dwellings and serves both dwellings*
only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*
* as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.
Note: Local codes or regulations may require different clearances
A = 6" (15.2 cm)
Inside Corner
V
B
E
V
B = 6" (15.2 cm)
C = Maximum depth of 48" (121.9 cm) for
recessed location
D = Minimum width for back wall of
recessed location -
Combustible - 38" (96.5 cm)
Noncombustible - 24" (61cm)
E = Clearance from corner in
recessed location-
Combustible - 6" (15.2 cm)
Noncombustible - 2" (5.1 cm)
Outside Corner Recessed Location
G
H
G = 12" (30.5 cm) minimum clearance
Balcony with No Side Wall
V
J
Combustible &
Noncombustible
H = 24" (61 cm)
J = 20" (50.8 cm)
Balcony with Perpendicular Side Wall
C
D
C
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
Figure 7 - Minimum Clearances for Termination Cap
LOCATION OF TERMINATION CAP
www.desatech.com
108860-01D 7
VENTING INSTALLATION
INSTRUCTIONS
     
attempting installation.
These models are tested and approved for use with DESA (direct-
vent) pipe components and terminations.
The venting system must terminate on the outside of the structure
and can not be attached to a chimney or ue system serving a
separate solid fuel or gas burning appliance. A direct-vent appli-
ance must have its own venting system. DO NOT common vent
this appliance.
These models are approved to be vented either horizontally through
an outside wall or vertically through a roof or chase enclosure using
the following guidelines:
When venting system terminates horizontally on an outside
wall, you must install a standoff if the termination cap is to be
installed directly on a combustible nish such as vinyl, wood,
stucco, etc.
Never run the vent downward as this may cause excessive tem-
peratures which could cause a re.
Vent pipe air space clearances to combustibles are 1" on all sides
except on the horizontal sections, which requires 2" clearance
from the top of the pipe. Where the termination cap penetrates
a combustible wall, 1" air space clearance is required.
Snorkel terminations are required when minimum clearance to
grade cannot be met (see Figure 16 on page 11).
Have replace and selected vent components on hand to help
determine the exact measurements when elbowing or offsetting.
Always use wall restops when penetrating walls and restops
when penetrating ceilings or attic spaces.
If using a venting conguration of only horizontal venting with
no vertical run, a 1/4" rise for every 12" of run toward the ter-
mination is required.
WARNING: Read all instructions completely and
thoroughly before attempting installation. Failure to
do so could result in serious injury, property damage
or loss of life.

the warranty.

Wear gloves and safety glasses for protection
Use extreme caution when using ladders or when on roof tops
Be aware of electrical wiring locations in walls and ceilings
The following actions will void the warranty on your venting system:
Installation of any damaged venting component
Unauthorized modication of the venting system (Do not cut or
alter vent components)
Installation of any component part not manufactured or approved
by DESA
Installation other than as instructed by these instructions

must be vented directly to the outside. The venting
system must NEVER be attached to a chimney serving
a separate solid fuel burning appliance. Each direct-
vent gas appliance must use a separate vent system.
Do not use common vent systems.
WARNING: Vent pipe air space clearances to com-
bustibles are 1" on all sides except on the horizontal
sections, which require 2" clearances from the top of
the pipe. Where the termination cap penetrates a com-
bustible wall, 1" air space clearance is required.
INSTALLATION PLANNING
There are two basic types of direct-vent installation:
Horizontal Termination
Vertical Termination
Horizontal Termination Installation
IMPORTANT: Horizontal square terminations require only inner
portion of wall restop. Horizontal installations using round ter-
mination require exterior portion of wall restop available only in
vent kit HTK (see Figure 14, page 10).
1. Set the replace in its desired location and determine the route
your horizontal venting will take. Do not secure the replace
until all venting has been installed. Some installations require
sliding the replace in and out of position to make nal venting
connections. Figures 14 through 18 on pages 10 and 11 show
different congurations for venting with horizontal termina-
tion that will help you decide which application best suits your
installation. Check to see if wall studs or roof rafters are in the
path of your desired venting route. If they are, you may want
to adjust the location of the replace.
www.desatech.com
108860-01D8
Figure 10 - Installing Horizontal Vent Cap
Wood Screw
Vent Cap
Apply Mastic to
All Four Sides
VENTING INSTALLATION
INSTRUCTIONS
Continued
2. Direct vent pipe sections and components are designed with
special twist-lock connections.
 The female ends of the pipes have
locking lugs (indentations). These lugs will slide straight into
matching slots on the male ends of adjacent pipes. Push pipe
sections together and twist one section clockwise approxi-
mately one-quarter turn until the sections are fully locked (see
Figure 8). Note: Horizontal runs of vent must be supported
every three feet. Use wall straps for this purpose.
3. Use a 45° elbow to connect venting system to replace ue
collar. The elbow is designed to be twist-locked onto the ue
collar as described in step 2. IMPORTANT: Do not attempt
to alter the conguration of the elbow by cutting, twisting,
bending, etc.
4. Assemble the desired combination of pipe and elbows to the
replace. If there are long portions of venting run, pre-as-
sembled pipe sections may be installed as subassemblies for
convenience.
5. Carefully determine the location where the vent pipe assembly
will penetrate the outside wall. The center of the hole should
line up with the center-line of the horizontal vent pipe. Mark
the wall for a 10" x 10" square hole. Cut and frame the square
hole in the exterior wall where the vent will be terminated. If
the wall being penetrated is constructed of noncombustible
material, such as masonry block or concrete, a 7
3
/4" hole with
zero clearance is acceptable (see Figure 9).
WARNING: Do not recess vent termination into any

6. Noncombustible Exterior Wall: Position the horizontal vent
cap in the center of the 7
3
/4" round hole and attach to the
exterior wall with four wood screws provided. Before attach-
ing the vent cap to exterior wall, run a bead of non-hardening
mastic (pliable sealant) around the outside edges to make a seal
between it and the outside wall. Note: The four wood screws
provided should be replaced with appropriate fasteners for
stucco, brick, concrete, or other types of sidings.
 For vinyl siding, stucco, or wood
exteriors, a siding standoff must be installed between the vent
cap and exterior wall. The siding standoff prevents excessive
heat from damaging the siding materials. Siding material
must be cut to accommodate standoff. Bolt the vent cap to the
standoff. Apply non-hardening mastic around outside edge of
standoff. Position the standoff/cap assembly in the center of the
10" square hole and attach to exterior wall with wood screws
provided (see Figure 11, page 9). The siding standoff must sit
ush against the exterior fascia material.
Figure 8 - Vent Pipe Connections
Female
Locking Lugs
Male
Slots
(Framing
Detail)
10"
(254 mm)
10" Inside Framing
(254 mm)
10"
(254 mm)
7
3
/
4
"
(197 mm)
Vent Opening
Combustible Wall
Vent Opening
Noncombustible Wall
Figure 9 - Vent Opening Requirements
Center
of Hole
www.desatech.com
108860-01D 9
VENTING INSTALLATION
INSTRUCTIONS
Continued
Figure 11 - Installing Siding Standoff
Vent Cap
(Horizontal
Termination)
Interior Wall
Surface
Wall
Firestop
Horizontal
Vent Pipe
Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe
Screw
Cut Siding Away
to Fit Standoff
Wood Screw
Screws
Standoff
Vent Cap
Apply Mastic to
All Four Sides
7. Slide the wall restop over the vent pipe before connecting
horizontal run to vent cap (see Figure 12).
8. Carefully move replace, with vent assembly attached, toward
wall and insert vent pipe into horizontal termination. The pipe
overlap should be a minimum of 1
1
/4".
9. Slide wall restop against interior wall surface and attach with
screws provided. See Figure 13 for horizontal termination
details.
10. Place replace into position and shim with noncombustible
material if needed. Nail or screw side anges to framing to
secure unit in place. IMPORTANT: Make sure replace is
level before securing. If replace is not level it will not work
properly.
Figure 13 - Typical Horizontal Termination Cap Mounting with
Additional Siding Standoff Installed
Siding Standoff
Screws
High Wind
Termination
Apply Mastic to
Outside Edge of
Standoff
Exterior Wall
with Vinyl Siding
10" x 10"
Framed
Opening
Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall
Minimum Pipe
Overlap 1
1
/
4
"
Wall
Firestop
Direct Vent
Pipe
www.desatech.com
108860-01D10
Vertical (V) Required Horizontal (H)
32" 36" Vertical Pipe (32"/36")
40
1
/2" min. 43
1
/4" min. None 30" max.
51
1
/2" min. 54
1
/4" min. 1 ft. 48" max.
63
1
/2" min. 66
1
/4" min. 2 ft. 60" max.
75
1
/2" min. 78
1
/4" min. 3 ft. 84" max.
87
1
/2" min. 90
1
/4" min. 4 ft. 20' max.
Figure 15 - Horizontal Termination Conguration for Corner
Installation Using One 90° Elbow
Square
Termination
Wall
Firestop
Not to Exceed
(H) Limits
As Required for (V)
See Chart for Pipe
Section Required
45°
Elbow
90° Elbow
90° Elbow
Square
Termination
Wall
Firestop
45° Elbow
12" Minimum
*Note: Ground Floor Corner Venting
Not to Exceed
(H) Limits
Square Termination
Vertical (V) Horizontal (H)
32" Series 29" min. 17" max.
36" Series 32" min. 17" max.
Horizontal High
Wind Square
Termination
Wall Firestop
45° Elbow
CORNER AND ALTERNATE INSTALLATION
Recommended Applications:
Corner ground oor installation
Ground oor installation where pipe vents horizontally through
wall (over 12" horizontal pipe)
Basement installation where one foot clearance from ground to
termination is possible
VENTING INSTALLATION
INSTRUCTIONS
Continued
Adjustable
Pipe 12" Max.
Figure 14 - Horizontal Termination Conguration for Square
and Round Terminations
45° Elbow
Wall
Firestop
Round
Termination
Cap
Exterior Portion of
Wall Firestop (Round
Termination Only)
Round Termination
(Kit HTK Shown)
Slide Ring
Over Elbow
to Complete
Connection

Figures 14 through 18 show different congurations and alterna-
tives for venting with horizontal termination. Each gure includes
a chart with critical minimum and maximum dimensions which
MUST be met. IMPORTANT: If using a venting conguration of
only horizontal venting with no vertical run, a 1/4" rise for every
12" of run toward the termination is required.
WARNING: Never run vent downward as this may
cause excessive temperatures which could cause a

venting system could result in serious injury, property
damage or loss of life.
GROUND FLOOR INSTALLATION
Recommended Applications:
Installation using cabinet surrounds
Through the wall using round or square termination (up to 12"
horizontal pipe)
NOT FOR CORNER INSTALLATION
www.desatech.com
108860-01D 11
SNORKEL TERMINATION INSTALLATION
Recommended Applications:
Installations requiring a vertical rise on building exterior
Any installation using snorkel termination to achieve one foot above ground
Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termina-
tion below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back ll
around snorkel termination.
VENTING INSTALLATION INSTRUCTIONS
Continued
12"
Minimum
Snorkel
Termination
Snorkel
Termination
12"
Minimum
Snorkel Termination
Wall
Firestop
90° Elbow
45°
Elbow
Figure 16 - Snorkel Termination Congurations for Below Ground Installation
12"
Minimum
Adequate
Drainage
HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS
The following congurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows.
45° Elbow
Venting with Two 90° Elbows
Vertical (V) Horizontal Horizontal (H
1
) +
(H
1
) Horizontal (H
2
)
5' min. 2' max. 6' max.
6' min. 4' max. 12' max.
7' min. 6' max. 18' max.
8' min. 8' max. 20' max.
20' max. 8' max. 20' max.
Figure 17 - Horizontal Termination Conguration for Venting
Using Two 90° Elbows
45° Elbow
Figure 18 - Horizontal Termination Conguration for Venting
Using Two 90° Elbows with Termination at 90° with Fireplace
Venting with Two 90° Elbows
Vertical (V) Horizontal (H
1
)
Horizontal (H
2
)
5' min. 6' max.
6' min. 12' max.
7' min. 18' max.
8' min. 20' max.
20' max. 20' max.
www.desatech.com
108860-01D12

Note: Vertical restrictor must be installed in all vertical installations.
1. Determine the route your vertical venting will take. If ceiling
joists, roof rafters, or other framing will obstruct the venting
system, consider an offset (see Figure 19) to avoid cutting
load bearing members. Note: Pay special attention to these
installation instructions for required clearances (air space)
to combustibles when passing through ceilings, walls, roofs,
enclosures, attic rafters, etc. Do not pack air spaces with insu-
lation. Also note maximum vertical rise of the venting system
and any maximum horizontal offset limitations.
2. Set the replace in desired location. Drop a plumb line down
from the ceiling to the position of the replace exit ue. Mark
the center point where the vent will penetrate the ceiling. Drill
a small locating hole at this point.
Drop a plumb line from the inside of the roof to the locating
hole in the ceiling. Mark the center point where the vent will
penetrate the roof. Drill a small locating hole at this point.
VENTING INSTALLATION
INSTRUCTIONS
Continued

1. Cut a 10" square hole in the ceiling using the locating hole
as a center point. The opening should be framed to 10"x10"
(254 mm x 254 mm) inside dimensions, as shown in Figure 9
on page 8 using framing lumber the same size as the ceiling
joists. If the area above the ceiling is an insulated ceiling or an
attic space, nail restop from the top side. This prevents loose
insulation from falling into the required clearance space. If the
area above the ceiling is a living space, install restop below
the framed hole. The restop should be installed with no less
than three nails per side (see Figure 20).
Figure 19 - Offset with Wall Strap and 45° Elbows
Figure 20 - Installing Firestop
If area above is a living
space, install restop
below framed hole.
If area above is an attic
space or insulated area,
install restop above
framed hole.
2. Assemble the desired lengths of pipe and elbows necessary to
reach from the replace ue up through the restop. Be sure all
pipe and elbow connections are fully twist-locked (see Figure
8, page 8).
3. Cut a hole in the roof using the locating hole as a center point.
(Cover any exposed open vent pipes before cutting hole in
roof.) The 10" x 10" hole must be measured on the horizontal;
actual length may be larger depending on the pitch of the roof.
There must be a 1" clearance from the vent pipe to combustible
materials. Frame the opening as shown in Figure 9, page 8.
4. Connect a section of pipe and extend up through the hole.
Note: If an offset is needed to avoid obstructions, you must
support the vent pipe every 3 feet. Use wall straps for this
purpose (see Figure 19). Whenever possible, use 45° elbows
instead of 90° elbows. The 45° elbow offers less restriction to
the ow of the ue gases and intake air.
5. Place the ashing over the pipe section(s) extending through
the roof. Secure the base of the ashing to the roof and framing
with roong nails. Be sure roong material overlaps the top
edge of the ashing as shown in Figure 19. There must be a
1" clearance from the vent pipe to combustible materials.
6. Continue to add pipe sections until the height of the vent cap
meets the minimum building code requirements described in
Figure 7 on page 6. Note: You must increase vent height for
steep roof pitches. Nearby trees, adjoining roof lines, steep
pitched roofs, and other similar factors may cause poor draft
or down-drafting in high winds. Increasing the vent height may
solve this problem.
7. Twist-lock the vent cap onto the last section of vent pipe.
Note: If the vent pipe passes through any occupied areas above the
rst oor, including storage spaces and closets, you must enclose
pipe. You may frame and sheetrock the enclosure with standard
construction material. Make sure and meet the minimum allow-
able clearances to combustibles. Do not ll any of the required air
spaces with insulation.
45° Elbow
Wall Strap
Roof Flashing
Ceiling Firestop
www.desatech.com
108860-01D 13
VENTING INSTALLATION
INSTRUCTIONS
Continued

Figures 21 through 24 show four different congurations for verti-
cal termination.
Venting with Two 90° Elbows
Vertical (V) Horizontal (H
1
) +
Horizontal (H
2
)
5' min. 2' max.
6' min. 4' max.
7' min. 6' max.
8' min. 8' max.
20' max. 8' max.
Figure 21 - Vertical Venting Conguration Using Two 90°
Elbows with Two Horizontal Runs (Vertical Round High Wind
Termination Shown)
Venting with One 90° Elbow
Vertical (V) Horizontal (H)
5' min. 2' max.
6' min. 4' max.
7' min. 6' max.
8' min. 8' max.
20' max. 8' max.
Figure 22 - Vertical Venting Conguration Using One 90°
Elbow (Vertical Round High Wind Termination Shown)
Note: Install restrictor
into inner collar of
replace as shown.
Venting with Two 90° Elbows
Vertical (V
1
) Horizontal (H)
5' min. 6' max.
6' min. 12' max.
7' min. 18' max.
8' min. 20' max.
Note: Vertical (V
1
) + Vertical (V
2
) = 40' max.
Figure 23 - Vertical Venting Conguration Using Two 90°
Elbows (Vertical Round High Wind Termination Shown)
Note: Install restrictor
into inner collar of
replace as shown.
45° Elbow
45° Elbow
45° Elbow
Note: Install restrictor
into inner collar of
replace as shown.
Vertical Venting
V = 40' max.
Figure 24 - Vertical Venting Conguration With No Horizontal
Run (Vertical Round High Wind Termination Shown)
Note: Install restrictor
into inner collar of
replace as shown.
45° Elbow
www.desatech.com
108860-01D14
VENTING INSTALLATION
INSTRUCTIONS
Continued
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent replace has been CSA tested and approved
for elevations from 0-2000 feet (USA) and elevations from 0-4500
feet (Canada).
When installing this replace at an elevation above 2000 feet (in the
USA), you may need to decrease the input rating by changing the
existing burner orice to a smaller size. Reduce input 4% for each
1000 feet above sea level. Check with your local gas company for
proper orice size identication.
When installing this replace at an elevation above 4500 feet (in
Canada), check with local authorities.
Consult your local gas company to help determine the proper orice
for your location.
For assistance with any high altitude installation contact DESA
Customer Service Department at 1-866-672-6040.
PARTS LISTS FOR VENTING KITS AND

DESA Pipe & Vent Kits
Number Description
P47-6 6" Section Coaxial Pipe - Galvanized
P47-12 12" Section Coaxial Pipe - Galvanized
P47-24 24" Section Coaxial Pipe - Galvanized
P47-36 36" Section Coaxial Pipe - Galvanized
P47-48 48" Section Coaxial Pipe - Galvanized
PA47-712 Adjustable 7"-12" Section Coaxial Pipe - Galvanized
VKG-47 Ground Floor Vent Kit - Galvanized
Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Fire-
stop, Horizontal Square Termination, and 16 Screws
VKB-47 Basement Vent Kit - Galvanized
Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall
Firestop, Horizontal Square Termination, 4' Pipe, 90°
Elbow, and 20 Screws
VKS-47 Snorkel Kit - Galvanized
Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Fire-
stop, 36" Snorkel Termination, 4' Pipe, 90° Elbow, and
26 Screws
VKR-47 Roof Vent Kit - Galvanized
Includes: 45° Elbow, 7"-12" Adjustable Pipe, Flue
Restrictor, Vertical High Wind Termination, 2' Pipe, 4'
Pipe, Firestop Plate, Roof Flashing (0/12-6/12), and
26 Screws
VKC-47 Corner Vent Kit - Galvanized
Includes: 45° Elbow, 7"-12" Adjustable Pipe, Horizon-
tal Termination, 6" Pipe, 90° Elbow, Wall Firestop, and
18 Screws
HTK Horizontal Round Termination Kit
Includes: Round Termination, Wall Firestop, and 45°
Elbow
DESA Elbows
Number Description
E47-45 45° Elbow - Galvanized
E47-90 90° Elbow - Galvanized
DESA Terminations
Number Description
HT-47 Horizontal Round Termination - Galvanized
HTS-47 Horizontal Square Termination - Galvanized
VT-47 Vertical Round Termination - Galvanized
ST-47-14 14" Snorkel Termination - Galvanized
ST-47-36 36" Snorkel Termination - Galvanized
DESA Venting Accessories
Number Description
SC-47 Storm Collar - Galvanized
WF-47 Wall Firestop - Galvanized
RF-47-6 Roof Flashing - 0 to 6/12 Pitch - Galvanized
RF-47-12 Roof Flashing - 6/12 to 12/12 Pitch - Galvanized
VR-47 Vertical Restrictor - Galvanized
S-47 Combustible Siding Standoff - Galvanized
WS-47 Wall Strap
FP-47 Firestop Plate
FIREPLACE INSTALLATION

Use proper gas type for the replace unit you are installing. If you
have conicting gas types, do not install replace. See retailer
where you purchased the replace for proper replace according
to your gas type.
INSTALLING OPTIONAL BLOWER


gas connections, shut off gas supply and disconnect
       
person to do this.
WARNING: If there is a duplex electrical outlet in-

base area, be sure that the electrical power to the outlet
is turned off before proceeding with blower installation.
Failure to do this may result in serious injury.
Model BK Installation
Follow all instructions provided in the blower accessory kit.
1. Attach the power cord to the blower motor by rmly pushing
the two female terminals at the end of the power cord onto the two
spade terminals on the blower motor (see Figure 25, page 15).
2. Attach green ground wire from power cord to blower housing
using screw provided (see Figure 25, page 15). Tighten screws
securely.
www.desatech.com
108860-01D 15
3. Place the blower against the lower rear wall of the rebox outer
wrapper with the exhaust port directed upward. The blower will
t inside the back opening and be held in position against the
back wall by the magnets (see Figure 25).
4. Be certain that all wire terminals are securely attached to ter-
minals on blower motor and that the screw retaining the green
ground wire is tight.
5. Mount speed control box to switch bracket by placing the plastic
control shaft forward through the opening in the switch bracket
(see Figure 26).
6. While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise until
it is tight against front panel. Place control knob provided on
shaft.
7. Turn on power to duplex outlet if previously turned off per the
warning in column 2, page 14.
8. Plug in blower power cord.
a. If your rebox is installed as a freestanding unit with an
accessory mantel, determine whether the power cord will
exit the left side or the right side of the rebox. Route power
cord through exit hole and plug the power cord into a wall
receptacle near the rebox.
b. If your rebox installation is recessed and/or pre-wired, plug
the power cord into the duplex outlet provided. Refer to your
rebox owner’s manual for instructions on wiring the duplex
outlet.

operation.
9. Check to make sure that the power cord is completely clear of
the blower wheel and that there are no other foreign objects in
blower wheel. Turn blower on and check for operation. Turn
blower off by turning knob fully counterclockwise before
continuing.
10. Peel off the backing paper and stick the supplied wiring diagram
decal on the rebox bottom approximately 12" in front of the
blower (see Figure 27).
FIREPLACE INSTALLATION
Continued
Figure 25 - Blower Model BK
Magnetic
Strips
Exhaust
Port
Screw
Green
Ground Wire
Spade
Terminals
Side View
Lower Firebox
Cavity
Blower
Location
Figure 26 - Attaching Speed Control to Firebox
Speed Control
Control Shaft
Locknut
Control Knob
Switch
Bracket
Duplex Outlet (Located
underneath rebox
oor against lower right
outside wall)
Blower
Plug-In
V
a
r
i
a
b
l
e
F
a
n
S
w
i
t
c
h
W
h
i
t
e
W
h
i
t
e
B
l
a
c
k
G
r
e
e
n
O
n
1
1
0
/
1
1
5
V
.
A
.
C
.
Blower
Moto
r
B
l
a
c
k
B
l
a
c
k
B
l
a
c
k
O
f
f
Figure 27 - Location of Wiring Diagram Decal (Model May
Vary From Illustration)
Wiring Diagram Decal
12" in Front of Blower
Model BKT Installation
Note: When installing the BKT thermostatically-controlled blower,
you must rst secure the thermal switch bracket to the blower if it
has not already been factory installed.
1. Place the green ground wire with ring terminal between the
bottom hole on the thermal switch bracket and the top ear hole
on the blower assembly. Insert the Phillips screw into all three
pieces and tighten securely (see Figure 28, page 16).
2. Connect wire harness and power cord terminals. Connect the
blue jumper wire to the blower motor terminal and the right
side terminal of the thermal switch. Connect the black wire to
the left side of the thermal switch and the white wire to the
other remaining blower motor terminal.
Note: The power cord outer insulation sleeve may have to be
stripped slightly to allow enough wire length to reach and make
all connections. DO NOT trim excessive length away. Just enable
enough to make all connections securely.
www.desatech.com
108860-01D16
FIREPLACE INSTALLATION
Continued
Figure 29 - Blower Wiring Diagram for Thermostat-Controlled
Models
Blower Wiring Diagram
      
when servicing controls. Wiring errors can cause im-
proper and dangerous operation. Verify proper opera-
tion after servicing.
3. Place the blower against the lower rear wall of the rebox outer
wrapper with the exhaust port directed upward and the thermo-
disc positioned up near the replace bottom. The thermodisc
must be oriented near the replace bottom as shown in Figure 28
in order to sense temperature and properly operate. The blower
will be held in position against the back wall by the magnets
incorporated onto the blower housing (see Figure 28).
4. Be certain that all wire terminals are securely attached to ter-
minals on blower motor and thermal switch, and that the screw
for the thermodisc bracket and green ground wire is tight.
5. Mount the speed control box against the mounting plate provided
in the lowerreplace cavity by placing the plastic control shaft
forward through the round hole (see Figure 26, page 15).
6. While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise until
it is tight against mounting plate. Place control knob provided
on shaft (see Figure 26, page 15).
7. Check to make sure that the power cord is completely clear of
the blower wheel and that there are no other foreign objects in
blower wheel. Also double check all wire leads and make sure
wire routing is not pinched or in a precarious position. Correct
accordingly.
8. Turn on power to duplex outlet if previously turned off per the
warning in column 2, page 14.
9. Plug in blower power cord to duplex outlet.
10. The blower will only run when the speed control knob is in the
ON position and the thermal switch senses temperature after the
replace begins to heat up. The blower speed can be adjusted by
rotating the control knob. To turn off, turn knob fully counterclock-
wise until it clicks off. If the blower is ON and has been running
with the replace operating, the blower will continue to run for a
short time after thereplace has been turned off. As the thermal
switch cools down, the blower shuts down automatically.
11. Peel off the backing paper and stick the supplied wiring diagram
decal on the rebox bottom approximately 12" in front of the
blower (see Figure 27, page 15).
Thermodisc
Figure 28 - Blower Model BKT
Air Flow Direction
Route BKT Blower
Through This Area
Magnets
Blower
Location
Side View Firebox Bottom
Black
Wire
Phillips
Screw
Blue Wire
Ring Terminal
on Green Wire
White Wire
Thermal Switch
Thermal
Switch
Bracket
Power Cord
Air Flow
Direction
Magnetic
Strips




     

requires an external regulator (not supplied). Install
-
pane/LP supply.
Installation Items Needed
Before installing replace, make sure you have the items listed below.
external regulator (supplied by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
test gauge connection *
sediment trap
tee joint
pipe wrench
approved exible gas line with gas connector (if allowed by local
codes)
* A CSA design-certied equipment shutoff valve with 1/8" NPT tap
is an acceptable alternative to test gauge connection. Purchase the
CSA design-certied equipment shutoff valve from your retailer.
Blue
Variable
Fan Switch
Fan Switch
(N.O.)
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
Black
www.desatech.com
108860-01D 17
FIREPLACE INSTALLATION
Continued
For propane/LP connection only, the installer must supply an
external regulator. The external regulator will reduce incoming
gas pressure. You must reduce incoming gas pressure to between
11" and 14" of water. If you do not reduce incoming gas pressure,
replace regulator damage could occur. Install external regulator
with the vent pointing down as shown in Figure 30. Pointing the
vent down protects it from freezing rain or sleet.

Internally-tinned copper tubing may be used in certain


pipe is too small, undue loss of volume will occur.
Installation must include an equipment shutoff valve, union, and
plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream fromreplace (see Figure 31).
IMPORTANT: Install main gas valve (equipment shutoff valve)
in an accessible location. The main gas valve is for turning on or
shutting off the gas to the appliance.
Check your building codes for any special requirements for locating
equipment shutoff valve to replaces.
Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged replace valves.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
We recommend that you install a sediment trap/drip leg in supply
line as shown in Figure 31. Locate sediment trap/drip leg where it
is within reach for cleaning. Install in piping system between fuel
supply and replace. Locate sediment trap/drip leg where trapped
matter is not likely to freeze. A sediment trap traps moisture and
contaminants. This keeps them from going into replace gas con-
trols. If sediment trap/drip leg is not installed or is installed wrong,
replace may not run properly.
Figure 30 - External Regulator with Vent Pointing Down
(Propane/LP Only)
Propane/LP
Supply Tank
External
Regulator
Vent
Pointing
Down
Figure 31 - Gas Connection
CSA Design-Certied
Equipment Shutoff Valve
with 1/8" NPT Tap*
3" Minimum
Approved Flexible
Gas Line
Cap Pipe Nipple Tee Joint
Sediment Trap/Drip Leg
Natural - From
Gas Meter (5.5"
W.C. to 10.5"
W.C. Pressure)
Propane/LP
From External
Regulator (11"
W.C. to 14" W.C.
Pressure)
* The CSA design-certied equipment shutoff valve may be supplied
with the appliance or you can purchase it from your retailer.

Installation Items Needed
5/16" hex socket wrench or nut-driver
sealant (resistant to propane/LP gas, not provided)
1. Open lower louver door panel by gently pulling forward.
2. Route exible gas line (provided by installer) from equipment
shutoff valve to replace. Route exible gas supply line through
one of the access holes on side of replace.
3. Attach exible gas line from gas supply to control valve (see
Figure 32).
4. Check all gas connections for leaks. See Checking Gas
Connections, page 18.
Figure 32 - Connecting Flexible Gas Line to Electronic Valve
1/2" NPT Incoming
Gas Line
Inlet Pressure Tap
Outlet Pressure Tap
Equipment
Shutoff Valve
Flexible Gas Line
Do NOT Kink
Note: Wire Connections Not Shown for Clarity
Red Surface Indicates
For Propane/LP Use Only
www.desatech.com
108860-01D18
Open
FIREPLACE INSTALLATION
Continued

WARNING: Test all gas piping and connections for

once.



at once.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

1. Disconnect replace and its individual equipment shutoff valve
from gas supply piping system. Pressures in excess of 1/2 psig
(3.5 kPa) will damage replace gas regulator.
2. Cap off open end of gas pipe where equipment shutoff valve
was connected.
3. Pressurize supply piping system by either opening propane/LP
supply tank valve for propane/LP gas replace or opening main
gas valve located on or near gas meter for natural gas replace,
or using compressed air.
4. Check all joints of gas supply piping system. Apply noncor-
rosive leak detection uid to all joints. Bubbles forming show
a leak. Correct all leaks at once.
5. Reconnect replace and equipment shutoff valve to gas supply.
Check reconnected ttings for leaks.

1. Close equipment shutoff valve (see Figure 33).
2. Pressurize supply piping system by either opening propane/LP
supply tank valve for propane/LP gas replace or opening main
gas valve located on or near gas meter for natural gas replace,
or using compressed air.
3. Check all joints from propane/LP supply tank or gas meter to
equipment shutoff valve (see Figure 34 or 35). Apply noncor-
rosive leak detection uid to all joints. Bubbles forming show
a leak. Correct all leaks at once.
Figure 33 - Equipment Shutoff Valve
Closed
Equipment
Shutoff
Valve
Figure 35 - Checking Gas Joints for Natural Gas Fireplace
Figure 34 - Checking Gas Joints for Propane/LP Gas
Fireplace
Propane/LP
Supply Tank
Gas Valve
Equipment
Shutoff
Valve
Gas
Meter
Gas Valve
Equipment
Shutoff
Valve

1. Open equipment shutoff valve (see Figure 33).
2. Open propane/LP supply tank valve for propane/LP replace
or main gas valve located on or near gas meter for natural gas
replace.
3. Make sure control knob of replace is in the OFF position.
4. Check all joints from equipment shutoff valve to gas valve (see
Figure 34 or 35). Apply noncorrosive leak detection uid to all
joints. Bubbles forming show a leak. Correct all leaks at once.
5. Light replace (see Operating Fireplace, page 23). Check all
other internal joints for leaks.
6. Turn offreplace (see To Turn Off Gas to Appliance, page 23).
www.desatech.com
108860-01D 19
FIREPLACE INSTALLATION
Continued

-

securely in place. For replacement part information see
Replacement Parts, page 28.


glass is hot. Keep children and pets away from glass.


door or louvers.
Removing Louver Panels
Remove the top and bottom louver panels by simultaneously pulling
both top end spring latches towards the center of the appliance until
they are disengaged from the locating holes (see Figure 36). Repeat
for bottom spring latches and pull the louvers outward. To install or
replace items removed, simply reverse the procedures above.
Lock
Unlock
Figure 36 - Removing Louver Panel
Louver Panel
Glass
Frame
Assembly
Screw
Figure 37 - Removing/Replacing Glass Door
Spring Latch
Hinge
Removing Glass Door
If replacement of glass is necessary, the entire assembly, glass and
frame, must be replaced. If glass is broken, wear gloves and tape
the remaining fragments onto the frame.
1. Remove screen assembly by pushing the rod either left or right
and then down and forward to remove screen/rod assembly
from the rebox. Set assembly aside.
2. Lift up on latches to unlock. There are two on top ofrebox and
two belowrebox that hold glass door in place (see Figure 37).
3. While holding glass door to prevent it from falling and causing
injury, remove the ve screws from the hinge located on the
left side of door frame assembly (see Figure 37).
4. Remount the new frame at the hinge with ve new screws
before closing door. This will ensure seating of the gasket.
Latch

See Cleaning and Maintenance on page 25.

MODELS BL32D, BL36D(S), BL36DH(S)


This brick liner kit is optional. You may purchase brick liner from
your local retailer or see Accessories, page 29.
      


1. Remove top and bottom louvers to allow access to door
latches.
2. Unlock door latches and open glass door. See steps 1 and 2 of
Removing/Replacing Glass Door.
3. If installing brick liner in new replace, go to step 4. If install-
ing brick liner in an existing replace, carefully remove logs,
lava rock, and ember material.
4. Remove three screws from deector shield on the inside top
of rebox. Set shield and screws aside.
5.
Close glass door frame. Lock latches by placing the bar under the
tab on door and pushing down and back on latch (see Figure 37).
6. Replace screen/rod assembly by reversing step 1.
7. Replace louvers by reversing procedure under Removing Lou-
ver Panels.
www.desatech.com
108860-01D20
FIREPLACE INSTALLATION
Continued
Figure 38 - Installing Rear Brick Panel
Figure 39 - Installing Left Side and Top Brick Panels
Rear Brick Panel
Left Side
Brick Panel
Top Brick Panel
(T36 Series Only)

GLOWING EMBERS
Note: 36" models shown. Logs will vary slightly for 32" models.
Each log is marked with a number. These numbers will help you
identify the log when installing. It is very important to install these
logs exactly as instructed. Do not modify logs. Only use logs sup-
plied with replace.
Open louvers, remove screen, unlock door latches, and open glass
door. See steps 1 and 2 of Removing/Replacing Glass Door, page 19.
Install logs according to instructions for replace model numbers.
1. Place log #1 (rear log) on top of grate. Make sure the notches
in the bottom of the log t over the grate (see Figure 40).
2. Rest log #2 (large front log) on the pins on the front part of the
grate (see Figure 41).
2
Figure 40 - Installing Log No. 1
Figure 41 - Installing Log No. 2
5. Install rear brick panel rst. Rest bottom edge of panel on back
edge of grate (see Figure 38).
6. Install top brick panel (36" Series only) by resting on the top
of the rear panel. Hold the top brick panel in place and install
left side brick panel by sliding it between the grate and the side
of the rebox, securing top panel (see Figure 39).
7. Install the right brick panel using the same method described
in step 6 for the left brick panel.
8. Replace deector shield using screws removed in step 4.
9. Follow instructions starting in column 2 to install logs, lava
rock, and ember material.
10. Close glass door, lock latches on top and bottom of door and
replace screen (see steps 5 and 6 of Removing/Replacing Glass
Door, page 19).
11. Close top and bottom louvers.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Desa VT36ENR1 User manual

Category
Fireplaces
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI