AIC J5010-02, the high-performance PCIe Gen4 JBOX, offers exceptional flexibility and speed for various applications. It supports a wide range of graphics cards, including the latest NVIDIA and AMD models, enabling you to harness the power of cutting-edge GPUs for demanding tasks like video editing, 3D rendering, and AI computing.

AIC J5010-02, the high-performance PCIe Gen4 JBOX, offers exceptional flexibility and speed for various applications. It supports a wide range of graphics cards, including the latest NVIDIA and AMD models, enabling you to harness the power of cutting-edge GPUs for demanding tasks like video editing, 3D rendering, and AI computing.

UM_J5010-01_v1.1_090221
J5010-02
PCIe Gen 4 JBOX
User's Manual
Table of Contents
Preface ������������������������������������������������������������������������������������������������ i
Safety Instructions ������������������������������������������������������������������������������ ii
About This Manual ����������������������������������������������������������������������������� iv
Chapter 1� Product Features �������������������������������������������������������������� 1
1�1 Box Content ���������������������������������������������������������������������������������������1
1�2 Specifications �����������������������������������������������������������������������������������2
1�3 Feature ���������������������������������������������������������������������������������������������� 3
Chapter 2� Hardware Setup ���������������������������������������������������������������� 6
2�1 Top Cover ������������������������������������������������������������������������������������������6
2�2 Power Supply Unit �����������������������������������������������������������������������������7
2.2.1 Installation ............................................................................................................ 7
2.2.2 LED Indicator ........................................................................................................7
2�3 Fan ���������������������������������������������������������������������������������������������������8
2�4 GPU Card �������������������������������������������������������������������������������������������9
2.4.1 Installation ............................................................................................................ 9
2.4.2 Power Cable Routing ..........................................................................................10
2�5 Low Profile Riser Card ���������������������������������������������������������������������11
2�6 Pull Card �����������������������������������������������������������������������������������������13
2�7 Filter ������������������������������������������������������������������������������������������������14
2�8 Slide Rail �����������������������������������������������������������������������������������������15
Chapter 3� Technical Support ����������������������������������������������������������� 18
Content
Copyright © 2021 AIC®, Inc. All Rights Reserved.
This document contains proprietary information about
AIC® products and is not to be disclosed or used except in
accordance with applicable agreements.
Document Release History
Release Date Version Update Content
August
2021 1 User's Manual release to public.
September
2021 1.1 Spec update.
Copyright
No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photo-static, recording
or otherwise, without the prior written consent of the manufacturer.
Trademarks
All products and trade names used in this document are trademarks or registered
trademarks of their respective holders.
Changes
The material in this document is for information purposes only and is subject to change
without notice.
Warning
1. A shielded-type power cord is required in order to meet FCC emission limits and also
to prevent interference to the nearby radio and television reception. It is essential
that only the supplied power cord be used.
2. Use only shielded cables to connect I/O devices to this equipment.
3. You are cautioned that changes or modifications not expressly approved by the
party responsible for compliance could void your authority to operate the equipment.
Disclaimer
AIC® shall not be liable for technical or editorial errors or omissions contained herein.
The information provided is provided "as is" without warranty of any kind. To the extent
permitted by law, neither AIC® or its aliates, subcontractors or suppliers will be liable
for incidental, special or consequential damages including downtime cost; lost prots;
damages relating to the procurement of substitute products or services; or damages
for loss of data, or software restoration. The information in this document is subject to
change without notice.
Instruction Symbols
Special attention should be given to the instruction symbols below.
NOTE This symbol indicates that there is an explanatory or
supplementary instruction.
CAUTION
This symbol denotes possible hardware impairment. Upmost
precaution must be taken to prevent serious harware damage.
WARNING
This symbol serves as a warning alert for potential body
injury. The user may suffer possible injury from disregard or
lack of attention.
Preface
i
ii
Safety Instructions
Before you commence, please attentively read the following important discretions below. All
cautions and warnings on the equipment or in the manuals should be circumspectly noted
and reviewed.
Always ground yourself to prevent static electricity.Always ground yourself to prevent static electricity.
全程接地,以防止靜電。全程接地,以防止靜電。
全程接地,以防止静电。全程接地,以防止静电。
Всегда заземляйте себя, чтобы избежать статического электричества.Всегда заземляйте себя, чтобы избежать статического электричества.
Aard jezelf altijd om statische elektriciteit te voorkomen.Aard jezelf altijd om statische elektriciteit te voorkomen.
Firmly ground yourself at all times when installing or assembling the internal
components of the server. Most of electronic components in the server are highly
sensitive to electrical static discharge.
Use a solid grounding wrist strap and distintively place all electronic components in
static-shielded devices to prevent static. Grounding wrist straps can be purchased in
any electronic supply store.
Confirm that the power source is turned off and then disconnect the power cords from
your system before performing any type of installation or manual servicing. A sudden
surge of power could serverly damage the sensitive electronic components.
Do not precipitously open the systems top cover. If you must open the cover for
maintenance purposes, only a trained technician should be allowed to proceed this
action. Integrated circuits on computer boards are highly sensitive to static electricity.
Before operating a board or integrated circuit, touch an unpainted portion of the system
unit chassis for a couple of seconds to discharge any static electricity on your body.
Place the server in a stable environment. Place the server in a stable environment.
將伺服器放置在穩定的環境中。將伺服器放置在穩定的環境中。
将伺服器放置在稳定的环境中。将伺服器放置在稳定的环境中。
Поместите сервер в стабильную среду.Поместите сервер в стабильную среду.
Plaats de server in een stabiele omgeving.Plaats de server in een stabiele omgeving.
Place this equipment on a stable surface when installing. A small mild drop or fall could
cause fatal injury to both the equipment and the person handling the equipment.
Please keep this equipment away from humidity to prevent vast rust and disintergration.
Carefully and accurately mount the equipment into the rack. Uneven mechanical
loading may lead to hazadous consequences.
This equipment is to be installed for operation in an environment with maximum
ambient temperature below 35°C.
Review the environment before performing any installation or servicing. Keep the
equipment away from hazardous and uneven grounds.
This server must be installed only in Restricted Acess Locations.
Handle equipment with care.Handle equipment with care.
請謹慎操作設備。請謹慎操作設備。
请谨慎操作设备。请谨慎操作设备。
Обращайтесь с оборудованием осторожно.Обращайтесь с оборудованием осторожно.
Behandel de apparatuur voorzichtig.Behandel de apparatuur voorzichtig.
Do not cover the openings of the system. The openings on the system are for air
convection, which intentionally protect the equipment from overheating.
Never pour any liquid into ventilation openings of the system. This could cause
catastrophic fire or electrical shock.
iii
Ensure that the voltage of the power source is within the specification on the label
when connecting the equipment to the power outlet. The current load and output power
of loads must be within the specification.
This equipment must be firmly connected to reliable grounding before usage. Pay
special attention to power supplied other than direct connections, e.g. using of power
strips.
Place the power cord out of the way of foot traffic. Do not place anything over the
power cord. The power cord must be rated for the product, voltage and current marked
on the product’s electrical ratings label. The voltage and current rating of the cord
should be greater than the voltage and current rating marked on the product.
Pay attention to hardware maintenance.Pay attention to hardware maintenance.
注意硬體維護注意硬體維護
注意硬体维护注意硬体维护
Обратите внимание на обслуживание оборудования.Обратите внимание на обслуживание оборудования.
Besteed aandacht aan hardware-onderhoud.Besteed aandacht aan hardware-onderhoud.
If the equipment is not used for a long time, disconnect the equipment from mains to
avoid being damaged by transient over-voltage.
Module and drive bays must not be empty. They must have a dummy cover.
Never open the equipment without professional assistence. For safety reasons, only
qualified service personnel should open the equipment.
If one of the following situations arise, the equipment should be checked and tested by
service personnel:
1. The power cord or plug is damaged.
2. Liquid has penetrated the equipment.
3. The equipment has been exposed to moisture.
4. The equipment does not work well or will not work according to its user manual.
5. The equipment has been dropped and/or damaged.
6. The equipment has obvious signs of breakage.
7. Please disconnect this equipment from the AC outlet before cleaning. Do not
use liquid or detergent for cleaning. The use of a moisture sheet or cloth is
recommended for cleaning.
CAUTION
The equipment intended for installation should be placed in Restricted Access Location.
CAUTION
There will be a risk of explosion if battery is replaced by an incorrect type. Dispose
of used batteries according to the instructions. After performing any installation or
servicing, make sure the enclosure is correct in position before turning on the power.
CAUTION
This unit may have more than one power supply. Disconnect all power sources before
maintenance to avoid electric shock.
Chapter 1 Product Features
J5010-02 is a highly commendable PCIe Gen4 JBOX that is specifically designed to
accommodate diverse corporations and enterprises who pursue flexibility and high speed
performance. This product supports hotswap designs and is easily deployed for your
benefit. For the latest version of this user's manual, please visit our AIC® website: https://
www.aicipc.com/en/productdetail/51309.
Chapter 2 Hardware Setup
This chapter displays an easy installation guide for assembling the main components of
the JBOX. Utmost caution for proceeding to set up the hardware is highly advised. Do not
endanger yourself by placing the device in an unstable environment. The consequences for
negligent actions may be extremely severe.
Chapter 3 Technical Support
For more information or suggestion, please verify and contact the nearest AIC® corporation
representative in your district or visit the AIC® website: https://www.aicipc.com/en/index.
It is our pleasure to provide the best service for our customers.
About This Manual
iv
1
J5010-02 is a high density Gen4 JBOX that supports high perfomance and high speed. For
more information about our product, please visit our website.
Before removing the subsystem from the shipping carton, visually inspect the physical
condition of the shipping carton. Exterior damage to the shipping carton may indicate
that the contents of the carton are damaged. If any damage is found, do not remove
the components; contact the dealer where the subsystem was purchased for further
instructions. Before continuing, first unpack the subsystem and verify that the number of
components in the shipping carton is accurate and in good condition.
1�1 Box Content
This product contains the components listed below.
Please confirm the number and the condition of the components before
installation.
Pre-installed into the system Number
2000W redundant power supply 80+ Platinum 1+1
Easy swap 120*38mm fan 6
Accessory Item Number
EPE foam for front board: 575*300*105H 1
EPE foam for rear board: 575*300*105H 1
EPE foam for front tray: 575*300*105H 1
EPE foam for rear tray: 563*300*145H 1
Power cord vary per region
26-inch tool-less slide rail assembly 1
BTO 1200W redundant power supply 80+ Platinum 1+1
Product features are subject to change without notice�
Chapter 1� Product Features
2
Chapter 1. Product Features
1�2 Specifications
J5010-02 is a highly compact Gen4 PCIe JBOX with PCIe switch and 2 sets of SFF-8644
for host uplink. Featuring the PCIe Gen4 switch, Broadcom Altas PEX88096, this product
provides agile performance and productivity.
Based on Broadcom Atlas 88096 PCIe Gen.4 Switch solution
450mm Short depth system design
High efficiency/wattage redundant power supply
High performance/low noise swappable system fan
BMC for system remote monitoring
Extended PCIe slot pitch for better air cooling flow
4U height PCIe card carrier design for top insertion power input Gaming GPU cards
Modular BP design options for different applications
- PCIe x16 GPU / PCIe x8 Add-on cards
General
PCI Switches Chip
Broadcom Atlas
PEX88096
PCIe Gen4 Switch
Host/Expansion
Interface 2x sets of 4 SFF-8644 for Host uplink
PCIe card
SupportedForm Factor
Supports 8 x full-height, full-length
dual slot/double width cards
2x PCIe X16 HHHL add-on card
2x PCIe X1 link for PCIe switch
management
BMCASPEED AST2520 BMC moduleIPMI 2.0 compliance
Hot swap and
Redundancy
Cooling 6 x 12038 PWM fans
Power Supply
2000W 2+2 hot swap redundant
80 + Platinum
1200W 2+2 hot swap redundant
80 + Platinum
Power Entry
AC Inlet
• 2000W module C20
• 1200W module C14
Electrical and
Environmental
Universal A/C Input • 2000W module AC200-240V
• 1200W module AC90-240V
Operating
Environment
Operating temperature : 0° - 35°C
System relative humidity : 20% - 80%
Non-operating
Environment
Operating altitude condition : 0 ~ 10K ft
Storage temperature : -20° ~ 60°C
System relative humidity : 10% - 90%
Physical
Dimensions
(W x D x H)
mm : 435 x 450 x 219
inches : 17.1 x 17.7 x 8.6
Gross Weight
(w/ PSU, Rail;
w/o Pallet, Disks)
kgs : 34.5
lbs : 76.1
Packaging
Dimensions
(W x D x H)
mm : 615 x 830 x 448
inches : 24.2 x 32.7 x 17.6
Mounting Standard 26” tool-less slide rail
3
Chapter 1. Product Features
1�3 Feature
Front Panel
Item Description
Power Button Power LED Status
Normal Off Off
Press Green Boot up
Long press Off Shut down
System Alert System Fault Normal
Red Off
System ID LED On Normal
Blue Off
BMC LAN port
BMC Console port
4
Chapter 1. Product Features
Rear Panel
Item Description
12000W 2+2 redundant power supply 80+ Platinum
or 1200W 1+1 redundant power supply 80+ Platinum (BTO)
PSU1PSU1 PSU2PSU2 PSU3PSU3 PSU4PSU4
Option 1: Slot1~ 4Option 1: Slot1~ 4
Slot1Slot1 Slot2Slot2 Slot3Slot3 Slot4Slot4 Slot5Slot5 Slot6Slot6 Slot7Slot7 Slot8Slot8 Slot9Slot9 Slot10Slot10 Slot11Slot11 Slot12Slot12 Slot13Slot13 Slot14Slot14 Slot15Slot15 Slot16Slot16
11
22
33
44
11
22
33
44
Option 1:
4 bay backplane
x16 lane
slot 1~8
Option 2:
8 Bay backplane
x8 lane
slot 1~16
Option 2: Slot1 ~8Option 2: Slot1 ~8
Slot5~ 8Slot5~ 8
Slot9 ~16Slot9 ~16
5
Chapter 1. Product Features
Top View
Option 1:
4 bay backplane x16 lane
slot 1~8
Option 2:
8 Bay backplane x8 lane
slot 1~16
Item Description
1 6 * 120x38mm easy swap fans
Hot swap fanHot swap fan
Hot swap fanHot swap fan
slot8 slot7 slot6 slot5 slot4 slot3 slot2 slot1slot8 slot7 slot6 slot5 slot4 slot3 slot2 slot1
slot16 slot14 slot12 slot10 slot8 slot6 slot4 slot2slot16 slot14 slot12 slot10 slot8 slot6 slot4 slot2
slot15 slot13 slot11 slot9 slot7 slot5 slot3 slot1slot15 slot13 slot11 slot9 slot7 slot5 slot3 slot1
6
Dislodge the screws on the top cover.
Press the release button and pull the cover towards the nearest
panel of the cover.
Lift upward to remove.
screw location
2�1 Top Cover
Chapter 2� Hardware Setup
This information is provided for professional technicians only.
Press and push Lift
7
Chapter 2. Hardware Setup
2�2�1 Installation
Press the ejector to release the module.
Pull the handle to remove the module out of the chassis.
Push the replaced power supply unit into the chassis. Ensure that the
module is hooked into the cage.
2�2 Power Supply Unit
This information is provided for professional technicians only.
2�2�2 LED Indicator
Indicator Color Behavior
Green (solid) Power is on.
Green
(blinking) Only 12Vsb (PS off) or PSU is in cold redundant state
Red (solid) Power has failed.
8
Chapter 2. Hardware Setup
Remove the top cover from the chassis. Please refer to Section 2.1 Top Cover.
Unplug the cables and connectors from the server board.
Pull the fan out of the chassis.
Insert the replaced fan into the chassis. Verify the alignment of the rubber
connectors of the fan and the bracket. Ensure that the fan is inserted into
the correct slot.
2�3 Fan
Rubber connectors
This information is provided for professional technicians only.
FAN_1 FAN_2 FAN_3
FAN_4 FAN_5 FAN_6
Fan Location (Top View)
Airflow
9
Chapter 2. Hardware Setup
2�4�1 Installation
Remove the top cover from the chassis. Please refer to Section 2.1 Top Cover.
Unsrew the captive screw and pull out the handle.
Pull the handle to remove the GPU tray.
Dislodge the screws on the bracket retainer.
Unplug all the cables on the GPU card. Please refer to Section 2.4.2 Power Cable Routing
for more information.
Dislodge the screws on the GPU card holder to replace the GPU card.
Repeat procedures 2 to 6 to replace the other GPU card.
2�4 GPU Card
This information is provided for professional technicians only.
10
Chapter 2. Hardware Setup
2�4�2 Power Cable Routing
NOTE
Cable routing may vary according to the GPU card you use. Below are two examples
provided on how to route your power cable.
Example 1: Power cable over the top
Example 2: Power cable on the side
11
Chapter 2. Hardware Setup
Remove the riser card bracket from the chassis.
Pull the riser card tray out of the chassis.
Dislodge the screws from the bracket to remove the bracket retainer.
Replace the riser card.
2�5 Low Profile Riser Card
This information is provided for professional technicians only.
12
Chapter 2. Hardware Setup
Smart NIC Card/Retimer Card/PCIe Devices to Host Connection
Connect the smart NIC card/Retimer Card/PCIe Devices to JBOX with the SFF-8644 to SFF-
8644 cable. Connect the ports 1, 2, 3 and 4 on the switch board to the corresponding slots 1,
2, 3 and 4 in the chassis.
This information is provided for professional technicians only.
NOTE
Smart NIC card/retimer/PCIe devices must be installed into the host server
system before connecting to the JBOX system. The Smart NIC card and host
server image is for reference only.
NOTE
JBOX can support up to 2 host server systems with PCIe devices in each.
Host server
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Smart NIC
card
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

AIC J5010-02 User manual

Category
Server/workstation motherboards
Type
User manual

AIC J5010-02, the high-performance PCIe Gen4 JBOX, offers exceptional flexibility and speed for various applications. It supports a wide range of graphics cards, including the latest NVIDIA and AMD models, enabling you to harness the power of cutting-edge GPUs for demanding tasks like video editing, 3D rendering, and AI computing.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI