Pro-face GP-PRO/PB III for Windows V5.0, GP-PRO/PB III for Windows V6.3, GP-PRO/PB III for Windows V7.2 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Pro-face GP-PRO/PB III for Windows V5.0 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
Thank you for purchasing the GP Screen Editor Software, "GP-PRO/PB III for
Windows Ver. 6.3" for use with Pro-face’s GP series programmable operator
interfaces.
Please read this manual carefully in order to use this software properly, and be
sure to keep this manual handy for future reference.
NOTES
(1) The copyrights to all programs and manuals included in the GP-PRO/PB
III for Windows Ver. 6.3 (hereinafter referred to as "this product") are
reserved by the Digital Electronics Corporation. Digital grants the use of
this product to its users as described in the "Software Operating License
Conditions" documentation, included with this product's CD-ROM. Any
actions violating the above-mentioned conditions are prohibited by both
Japanese and foreign regulations.
(2) The contents of this manual have been thoroughly inspected. However, if
you should find any errors or omissions in this manual, please inform your
local GP representative of your findings.
(3) Regardless of article (2), the Digital Electronics Corporation shall not be
held responsible for any damages or third party claims resulting from the
use of this product.
(4) Differences may occur between the descriptions found in this manual and
the actual functioning of this product. Therefore, the latest information on
this product is provided in data files (i.e. Readme.txt files, etc. ) and in
separate documents. Please consult these sources as well as this manual
prior to using the product.
(5) Even though the information contained in and displayed by this product may
be related to intangible or intellectual properties of the Digital Electronics
Corporation or third parties, the Digital Electronics Corporation shall not
warrant or grant the use of said properties to any users and/or other third
parties.
(6) The specifications set out in this manual are for overseas products only. As
a result, some differences may exist between the specifications given here
and for those of the identical Japanese product. Digital Electronics Corpo-
ration accepts no liability for issues related to the intellectual property rights
of third parties or any issues related to the use of the information contained
in or displayed by this product.
PREFACE
For the rights to trademarks and trade names, see “TRADEMARK RIGHTS”.
© Copyright 2003 Digital Electronics Corporation. All rights reserved.
Digital Electronics Corporation, September 2003
PREFACE
2GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
All company or product names used in this manual are the trade names, trade-
marks (including registered trademarks), or service marks of their respective
companies.
This product omits individual descriptions of each of these rights.
The following terms differ from the above mentioned formal trade names and
trademarks.
TRADEMARK RIGHTS
Trademark / Trade Name Right Holder
Microsoft, MS, MS-DOS, Windows,
Windows 95, Windows 98, Windows
Me, Windows NT, Windows 2000,
Windows XP, Windows Explorer,
Microsoft Excel
Microsoft Corporation, USA
Intel, Pentium Intel Corporation, USA
Pro-face Digital Electronics Corporation
(in Japan and other countries)
Ethernet Western Digital Electric Corporation,
USA
IBM, VGA, IBM Compatible International Business Machines
Corporation (IBM), USA
TRADEMARK RIGHTS
Term used in this manual Formal Trade Name or Trademark
Windows 95 Microsoft® Windows®95 Operating System
Windows 98 Microsoft® Windows®98 Operating System
Windows Me Microsoft® Windows®Me Operating System
Windows NT Microsoft® Windows NT® Operating System
Windows 2000 Microsoft® Windows® 2000 Operating System
Windows XP Microsoft® Windows®XP Operating System
3
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
LIST OF SUPPORTED MODELS
The GP-PRO/PBIII for Windows Ver. 6.3 functions and settings available will
vary, depending on the model of GP used. Use the following table to identify your
GP.
List of GP Series Products
LIST OF SUPPORTED MODELS
Product
Name Model GP Type
GPH70-LG11-24V
GPH70-LG41-24VP
GPH70-SC11-24V
GPH70-SC41-24VP
GP270-LG11-24V
GP270-LG21-24VP
GP270-LG31-24V
GP270-SC11-24V
GP270-SC21-24VP
GP270-SC31-24V
GP370-LG11-24V
GP370-LG21-24VP
GP370-LG31-24V
GP370-LG41-24VP
GP370-SC11-24V
GP370-SC21-24VP
GP370-SC31-24V
GP370-SC41-24VP
GP470-EG11
GP470-EG21-24VP
GP470-EG31-24V
GP570-LG11-24V
GP570-LG21-24V
GP570-SC11
GP570-SC21-24VP
GP570-SC31-24V
GP570-TC11
GP570-TC21-24VP
GP570-TC31-24V
GP-57JS
GP57J-SC11
GP-570VM
GP570-TV11
GP570VM
GP-571 series
GP-571T
GP571-TC11
GP571T
GP-675S
GP675-SC11
GP675-TC11
GP675-TC41-24VP
GP-870 series
GP-870VM
GP870-PV11
GP870VM
GP-37W2 series
GP-37W2B
GP37W2-BG41-24V
GP37W2
GP377-LG11-24V
GP377-LG41-24V
GP377-SC11-24V
GP377-SC41-24V
GP377R-TC11-24V
GP377R-TC41-24V
GP477R-EG11
GP477R-EG41-24VP
GP577R-SC11
GP577R-SC41-24VP
GP577R-TC11
GP577R-TC41-24VP
GP370L
GP-370S
GP470
GP570
GP570L
GPH70L
GPH70S
GP270L
GP270S
GP577R
GP-577R series
GP-477RE
GP-577RS
GP-577RT
GP477R
GP377R
GP675
GP377L
GP377S
GP77R series GP-477R series
GP-377S
GP-377L
GP-377 series
GP-377R series GP-377RT
GP70 series
GP-570S
GP-570T
Series
GP-370L
GP-370S
GP-470 series GP-470E
GP-370 series
GP-H70 series
GP-270 series
GP-270L
GP-270S
GP-675T
GP-H70L
GP-H70S
GP-675 series
GP-570L
GP-570 series
4GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
LIST OF SUPPORTED MODELS
Product
Name Model GP Type
GLC100L GLC100-LG41-24V GLC100L
GLC100S GLC100-SC41-24V GLC100S
GLC300 series GLC300 series GLC300T GLC300-TC41-24V GLC300T
GLC2300L GLC2300-LG41-24V GLC2300L
GLS2300T GLC2300-TC41-24V GLC2300
GLC2400 series GLC2400T GLC2400-TC41-24V GLC2400
GLC2600 series GLC2600T GLC2600-TC41-24V GLC2600
GLC2000 series GLC2300 series
Series
GLC100 series GLC100 series
List of GLC Series Products
List of Supported Factory Gateway
Product name Model GP Type
Factory Gateway FGW-SE41-24V Factory Gateway FGW-SE
To use the GPWeb and GPViewer functions with the Factory Gateway, you
must have GPPRO/PB III C-Package02 or later installed.
Product
Name Model GP Type
GP-2301H series GP-2301HL GP2301H-LG41-24V GP2301HL
GP-2301HS GP2301H-SC41-24V GP2301HS
GP-2401H series GP-2401HT GP2401H-TC41-24V GP2401H
GP-2300L
GP2300-LG41-24V
GP2300L
GP-2300S
GP2300-SC41-24V
GP2300S
GP-2300T
GP2300-TC41-24V
GP2300
GP-2301L
GP2301-LG41-24V
GP2301L
GP-2301S
GP2301-SC41-24V
GP2301S
GP-2301T
GP2301-TC41-24V
GP2301
GP-2400 series
GP-2400T
GP2400-TC41-24V
GP2400
GP-2401 series
GP-2401T
GP2401-TC41-24V
GP2401
GP-2500L
GP2500-LG41-24V
GP2500L
GP-2500S
GP2500-SC41-24V
GP2500S
GP2500-TC11
GP2500-TC41-24V
GP-2501L
GP2501-LG41-24V
GP2501L
GP-2501S
GP2501-SC11
GP2501S
GP-2501T
GP2501-TC11
GP2501
GP2600-TC11
GP2600-TC41-24V
GP-2601 series
GP-2601T
GP2601-TC11
GP2601
GP2000
series
Series
GP-2501 series
GP-2600 series
GP2000H
series
GP-2300 series
GP-2500 series
GP-2301 series
GP-2600T GP2600
GP2500GP-2500T
List of Supported STs
Series Product name Model GP Type
ST400 ST400-AG41-24V ST400
ST401 ST401-AG41-24V ST401
ST402 ST402-AG41-24V ST402
ST400
series
5
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
NEW FEATURES OF VERSION 6.1
NEW FEATURES OF VERSION 6.1
New features of GPPRO/PBIII for Windows Ver. 6.1 include the CSV Data
Transfer function, CSV Data Display function, and File Manager Display function.
This section briefly describes each function and lists the GP Series units that
support that function.
<All GP Series>
Parts Palette
The parts are displayed within a palette on the Screen Editor. Simply drag an item
from the Parts Palette and drop it at the desired location on the screen.
1.3.1 Screen Editor Item Names and Functions
Address Conversion when changing the PLC
When the PLC type is changed, a conversion pattern can be specified for the
available device of the destination PLC. The addresses belonging to the specified
pattern can be converted in one operation. The conversion pattern can be edited
and appended.
4.2.7 Changing Your Project’s Device/PLC Type and
Addresses
Address Conversion with Global Cross Reference
The desired addresses can be converted via the global cross reference.
2.9.7 Cross Reference List
Extended Function of Keypad Input Display
These new features provide K-tag settings (except for “Arithmetic Operation”)
and a Pop-up Keypad interlock.
2.1.14 Keypad Display, Tag Reference Manual 2.12 K-
tag (Key Input)
Extended Function of Numeric Displays
The display style of the N-tag can be specified with a Numeric Display Part.
2.1.21 Numeric Displays
Project Backup Function
When a Project file is saved, the backup data of the most recently saved Project
file is saved in a backup file (*.bak).
4.2.2 Backing up Project Files
6GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
NEW FEATURES OF VERSION 6.1
<GP377/GP77R/GP2000 Series>
Extended Function of Message Display
Index text can be used as the character strings displayed on the Message Dis-
plays. Two or more lines of messages can be displayed with this function.
2.1.22 Message Display, 4.6 Table Editor Character
Strings
<GP2000 Series>
CSV Data Transfer Function
A specific data-transferring CSV file (ZR*****.CSV) on the CF Card can be
transferred from the CF Card directly to the PLC (filing), and from the PLC
directly to the CF Card (logging). The data transfer method can be selected as
either automatic transfer (using the Control Word Address) or manual transfer
(performed with the touch panel). The Data Transfer Display is used with manual
transfer. The Data Transfer Display is useful for searching files because the file
names of the data-transferring CSV file (ZR*****.CSV) can be displayed in a
list.
2.1.18 Data Transfer Display, Tag Reference Manual 4.4
CSV Data Transfer Function
The selected file can be viewed, edited and printed when this function is used
together with the CSV Display.
2.1.19 CSV Display, Tag Reference Manual 4.5 CSV
Data Display Function
CSV Data Display Function
The CSV file on the CF Card can be displayed, edited, and printed with the CSV
Display. Set up the CSV Data Display along with the File Manager Display or
Data Transfer Display.
2.1.19 CSV Display, Tag Reference Manual 4.5 CSV
Data Display Function
File Manager Display Function
The structure of folders and files on the CF Card can be displayed in a list with
the File Manager Display. When this function is used together with the CSV
Display, the selected file can be viewed, edited and printed.
2.1.20 File Manager Display, Tag Reference Manual 4.6
File Manager Display Function
Extended SIO Script Feature
This programming feature is dedicated to communication between the GP and the
I/O device connected to the extended SIO (Extended serial interface) built into
the GP.
This function is supported only by the GP2000 Series units with built-in Extended
SIO (GP2300/2400/2500/2600 Series). This function uses the Extended SIO
Script Protocol that is added to this series.
7
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
2.7 Extended SIO Script, Tag Reference Manual 3.2
Extended SIO Script
GLC Ladder Monitor Function
The logic programs in the GLC can be displayed on the GLC screen.
This function is supported only by the GLC-2400/2600 Series.
Pro-Control Editor Ver. 4.1 User's Manual
SRAM Auto Backup Function
Backups of the GP's SRAM data (data on the GP) can be made to the CF Card.
The Control Word Address is used to trigger this function.
Tag Reference Manual, 4.7.9 Making a Backup of
Backup SRAM
Extended Function of Trend Graphs
The trend graph functions are extended as follows:
• Data backup and previous data can be displayed.
• Up to 40 trend lines can be displayed, including data sampling.
2.1.12 Trend Graphs, Tag Reference Manual 2.31 Trend
Graph Display
Extended Scaleable Text and Display Size
The Character Size for text and part labels as well as the display size for tags and
loading marks can be selected from integers 1 through 8.
2.2.9 Text, Tag Reference Manual 2.1.3 Setting Param-
eters
New PLC Protocol
Fenwal Controls of Japan: AL Series Temperature Controller
Omron: SYSMAC-C Series (CQM1H-CPU51/CQM1H-CPU61) (For 1:n
connection)
Keyence: KV-700 Series (Direct connection with CPU)
Rockwell (Allen-Bradley): ControlLogix 5000 Series
Siemens: S7-200/300/400 Series (Direct connection with MPI port)
JT Engineering: JE-70 Series Analyzer
Meidensha: UNISEQUE Series (Ethernet connection)
Yasukawa Electric: G7/F7 Series and VS mini V7/J7 Series Inverter Variable
Speed
Device/PLC Connection Manual
NEW FEATURES OF VERSION 6.1
8GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
NEW FEATURES OF VERSION 6.2
NEW FEATURES OF VERSION 6.2
The upgrade from GP-PRO/PB III for Windows Ver. 6.1 to Ver. 6.2 adds the
following features. These include new functions such as the D-Script/Extend SIO
Script’s CF Card File Operation function, extended trend graph functions, and
monochrome LCD (eight levels of gray) support. This section briefly describes each
function and provides a list of the GP Series units that support each function.
<All GP Series>
Comparison of the project file (.prw) displayed on the GP screen and the file
selected with the PC
When the project file (.prw) selected with the PC is transferred to the GP, the
transferred file and the file on the GP screen are compared and any differences
are reported.
7.3.1 GP Internal Screen Data Information
Compare List
Transfer mode setting
Transfer modes can be selected in the [Transfer] dialog box.
You can select whether to prepare and execute the transfer simultaneously to
reduce the transfer time, or to complete the preparation and check errors before
executing the transfer.
7.2.1 Transferring Setting
Protection of project files
The selected project file (.prw) can be fully protected so that it can be opened
and edited only with a password.
4.2.9 Protect Setting
Background color selection for bar/pie/half pie graph Parts and G-tags
(available with GP-377, GP77R and GP2000 Series)
The background color of a graph can be selected during color setting of G-tags
and bar/pie/half pie graph parts.
2.1.7 Bar Graphs, 2.1.8 Pie Graphs, 2.1.9 Half Pie
Graphs, Tag Reference Manual 2.8 Graph Display <G-tag>
<GP2000 Series monochrome LCD model only>
Monochrome eight-level gray-scale display
Parts and images can be displayed on the GP screen in monochrome (eight levels
of gray). JPEG images of GP screens can also be captured and saved to a CF
Card (screen hard copy). With a GP-2300L, GP-2500L or GP-2501L, screen
data can be printed out in monochrome as well.
2.1 Parts
Selecting Colors and 6.1 Menu Setting
Items: GP Setup
Initial Screen Settings
Tag Reference Manual
4.11.3 Monochrome (eight levels of gray) mode
9
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
NEW FEATURES OF VERSION 6.2
<GP2000 Series only>
Extended trend graph function
The following new functions have been added to the "Block Display" trend graph.
The display range (display width of graph data) can be designated indirectly.
Also, magnification and reduction of display is possible.
A trend graph can be displayed with dots or with a combination of dots and
lines.
You can display assistant lines (upper-lower limit lines, standard value line) for
the X or Y axes. Assistant line positions can be designated either directly or
indirectly.
2.1.12 Trend Graphs, Tag Reference Manual 2.31 Trend
Graph Display
CSV data transfer function: Condition name search and transfer
When a condition name (product number, etc.) is entered in the GP's LS Area or
the device address of the connected device with a bar code reader or other
device, a search is made for CSV files matching the name. Any matching CSV
files found are automatically transferred from the CF Card to the connected
device according to the transfer condition.
Tag Reference Manual 4.4 CSV Data Display Function
New functions for D-Script
New functions are added for use with D-Script, global D-Script, and extended
SIO Script.
"CF file operation" statements
These can be used for files in a CF Card such as "File Write", "File Read" and
"File List".
"Printer port operation" statement
Outputs the number of bytes of data, specified with the "Printer port output"
function, from the printer port.
Tag Reference Manual 3.1 D-Script/Global D-Script, 3.2
Extended SIO Script
Serial I/F Switch function
The communication program used by the Serial I/F (COM1) and the Extended
Serial I/F (COM2) can be changed. In order to use RS-422 with Serial I/F
(COM1), a multi-drop connection with the external device (using the Extended
SIO Script’s Protocol) is possible. Communication via the Serial I/F (COM1)
using the Extended SIO Script’s Protocol is possible even for a GP2000 Series
unit that does not have an Extended Serial I/F (COM2).
4.2.8 Changing Extended SIO Type
10 GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
NEW FEATURES OF VERSION 6.2
Conversion from a backup file (.mem) to a project file (.prw)
The GP backup file (.mem) created with the CF Memory Loader Tool of the GP-
PRO/PB III can be converted into a project file (.prw).
10.6.6 Creating a PRW file
CF Memory Loader Tool: Downloading multiple projects
When the CF Memory Loader Tool is activated, a backup file (*.mem) can be
specified for uploading /downloading multiple projects from/to the GP unit;
Changing the GP unit’s data no longer requires data to be sent many times from
the GP-PRO/PBIII. It can be done using a single CF Card. Also, the details of
the selected CF Card can be listed; and files can be copied, deleted or renamed.
10.7 CF Memory Loader Tool
7-segment display
Numerical values for the keypad, numeric, date and time displays can be indi-
cated with a 7-segment display.
2.1.14 Keypad Display, 2.1.21 Numeric Displays,
2.1.23 Date Displays, 2.1.24 Time Displays
Support for Epson PM series and Epson Stylus series printers (except GP-
2301H/GP-2401H/GP-2301 Series units)
Now compatible with Epson PM/Stylus Series (6-color) and Epson Stylus Series
(4-color) printers.
6.1 Menu Setting Items: GP Setup
I/O Settings, 6.2
Printer Type
New PLC Protocols
Hitachi Industrial Equipment Systems: HIDIC H series (Ethernet connection)
Rockwell (Allen Bradley): SLC500 series (Ethernet connection)
RKC Instrument: CB/REX-F/LE100 series RKC protocol
Shimaden: SR253/SR90/SR80/MR13/FP93/SD16/EM70 series
Additional information on each protocol
11
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
NEW FEATURES OF VERSION 6.3
The upgrade from GP-PRO/PB III for Windows Ver. 6.2 to Ver. 6.3 adds the
following features. These include new functions such as support for the new ST
unit, security features, time schedules and others.
New ST Series unit Compatibility
Unit Models: ST400/ST401/ST402
ST Series units have a variety of new features and usage restrictions. For more
information,
GENERAL GP RESTRICTIONS, 2.11 Creating ST
Series Screen
<All GP Series>
Selectable copy direction for multiple copy feature.
When copying multiple objects or images in the Editor screen, any of 8 copy
directions can be selected, as well as the arrangement and position of the copies.
2.4.7 Duplicate
Extended Font Sizes
When selecting a text string, Part label or Tag's character size, 6 x 10 dot, 8 x 13
dot, and 13 x 23 dot sizes are available. (Except for CSV displays and Logging
settings) These fonts are available only for single-byte numbers and symbols. If
these settings are used with double-byte characters, the display may no appear as
expected.
2.2.9 Text
Half-2 Byte Character (Only Chinese, Taiwanese and Korean OS)
When displaying a 2-byte font (Chinese, Taiwanese or Korean), if the character
size (Font Size) setting is set to "half", 2-byte character is compressed vertically to
display as a half-height 2-byte character.
This feature can be used with Text strings, Bit Switches, Word Switches, Function
Switches, Toggle Switches, 4-State Switches, Lamps and Message Displays.
This function is not available with GP-270 Series units.
<GP-377/GP77R/GP2000 Series >
Index Text Centering Arrangement (inside of box)
When using index text in a Text or Message Display, depending on the number of
characters and rows used, this text will be centered within a single box/border.
4.6.3 Entering Settings via the Screen Editor
NEW FEATURES OF VERSION 6.3
12 GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
< ST Series only>
Security
Security levels can now be assigned to individual Base or Window screens. As a
result, when changing or calling up a new screen, password entry is required.
Security levels are from 0 to 15, where a screen requiring the highest level of
security would be designated as Level 15.
2.11.3 Security Feature
Time Schedule
This feature allows a designated time schedule (day and time) to be started via a
Bit/Word set, or a Bit reset. If the Filing data (recipe) or D-Script feature control
addresses are set for this feature, that feature can be activated/performed at the
designated start time (or finish time). Settings can be for less than one day, or can
span 2 days or more (within a week).
2.11.7 Time Schedule
OFFLINE Language Switching
A simple push of a key allows you to change the display language used for your
ST unit from Japanese to English, or vice versa. No need to send a new system
program to your ST unit.
ST Series User Manual
New PLC Protocol
• Yaskawa Electric MP2300 Series (Ethernet connection)
• Keyence KZ Series
• Mitsubishi Electric FX Series (Direct CPU and l:n Link Protocol)
• Chino Temperature Controller LT, JU Series
Device/PLC Connection Manual
NEW FEATURES OF VERSION 6.3
13
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
Structure of the Manual CD-ROM
The "Operation Manual" is the first of four manuals for this product and explains
how to use the "GP-PRO/PB III for Windows Ver. 6.3" software (hereinafter
referred to as "this product"). Please refer to all of the manuals named below
when using this product.These manuals can be found as PDF files in your
“Manual CD-ROM” (CD #2).
In addition to these manuals, data files containing supplemental information on
updated functions are also provided.To read these additional data files, click on
the [Start] button in your Windows OS main screen and select the
[Programs][Pro-face][ProPB3 C-Package] menu. Then, click on the [Read
Me] selection.
For detailed information about GP series products, please refer to each GP's
"User Manual". (Optionally available)
Screen Data Layout Sheets are useful for designing tag address settings, etc. and
example sheets are installed as part of the GP-PRO/PBIII for Windows standard
installation.
The following two layout sheets, "Device Allocation Table" and "Tag Layout
Sheet", are in Microsoft Excel format and are located in the PDF Manual CD-
ROM.
The following folder and file names are used.
HOW TO USE THIS MANUAL
For information on the use of Microsoft Excel, please refer to the Excel
software's User Manual.
Designation of Supported Models
The functions and settings supported by each model may vary depending on the
supported models. In this manual, explanations given are based on the variation of
the “Series” and “Product name” described in the “List of Supported Models”.
Folder Name File Name Contents
Pro-face\ Device1E.xls Device Allocation Table
propbwin\sheet TAG1E.xls
TAG2E.xls
TAG3E.xls
TAG4E.xls
Tag Layout Sheet
HOW TO USE THIS MANUAL
vol. 1 Operation Manual
(this manual) Describes this product's operation procedures and a
ll
standard functions. (provided as PDF data)
Vol. 2 Tag Reference
Manual Describes the function of and detailed settings for all
GP-PRO/PBIII Tags. (provided as PDF data)
Vol. 3 Parts List Describes this product's pre-made Parts and symbol
s.
(provided as PDF data)
Vol. 4 Device/PLC
Connection
Manual
Describes the methods for connecting the GP to
supported devices from other manufacturers.
(provided as PDF data)
14 GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
Chapter Breakdown
This manual contains 12 chapters and an appendix.
The following is a general description of each chapter:
CHAPTER 1: FUNDAMENTALS OF GP-PRO/PB III FOR WINDOWS
This chapter describes GP-PRO/PBIII usage from start to finish. Also explains
the overall structure of the GP-PRO/PBIII Project Manager and Screen Editor
areas.
CHAPTER 2: CREATING BASE SCREENS
This chapter describes the basic operations and terminology used for drawing
functions, such as “Part”, “Tag”, “Library”, and “D-Script”.
CHAPTER 3: DRAWING APPLICATIONS: CREATING and USING
SCREENS
This chapter describes the procedures for creating and using various screens,
such as the M, T, K, X, I and V screens, which enable you to create high-quality
images and provide advanced-level functionality.
CHAPTER 4: SCREEN AND PROJECT MANAGEMENT
This chapter describes the procedures for editing and saving created screens and
project files, and information management procedure.
CHAPTER 5: CREATING AND EDITING ALARMS
This chapter describes the alarm creating and editing procedures.
CHAPTER 6: GP INITIAL AND SYSTEM SETTINGS
This chapter describes the initial setup procedure required to use a GP series
display unit.
CHAPTER 7: TRANSFERRING DATA
This chapter describes the procedure for sending created screens to a GP series
display unit.
CHAPTER 8: SIMULATION
This chapter describes the procedures for simulating the operation between a GP
series panel and a PLC.
CHAPTER 9: PRINTING
This chapter describes the procedure for printing created screens.
CHAPTER 10: ADVANCED FEATURES
This chapter describes the procedures for using GP-PRO/PBIII’s advanced
functions such as sound output, filing data (recipe), CSV data transfer function,
logging functions, and CF Card usage. For the detailed information, refer to
Volume 3, Tag Reference Manual.
CHAPTER 11: PROJECT MANAGER HIERARCHICAL DISPLAY
This chapter describes the procedures for using the Project Manager in hierarchi-
cal display mode.
CHAPTER 12: DATA COMPATIBILITY
This chapter describes the procedure for converting existing screens created with
older generation screen editor software (e.g. GP-PRO, GP-PRO II, GP-PRO
III, Parts Box) with GP-PRO/PB III for Windows.
HOW TO USE THIS MANUAL
15
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
APPENDIX
• Error Messages
Lists the error messages that will be displayed during operation of this product.
• Troubleshooting
Provides problem diagnosis and suggests solutions for errors and software
operation problems.
• Address Conversion Tables
Lists the addresses available for each manufacturers supported models.
• Software Trouble Report
If a software problem persists, even after using the Troubleshooting section, write
down information about the problem using this sheet and send it by fax to your
local Pro-face support center.
HOW TO USE THIS MANUAL
16 GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
Symbol Description
Provides hints on correct product use, or supplementary
information.
Indicates an item's related information (manual name, chapter,
section, sub-section).
Refers to keys on the computer keyboard.
Keyboard Compatibility List
IBM Compatible Indicates a PC that can run the Windows® operating system.
Device A device connected to the GP, such as a programmable logic
controller, sequencer, thermoregulator or inverter.
Generic name for the "GP Series" of programmable operator
interface made by the Digital Electronics Corporation. For a
list of compatible GP products please see "Compatible
Products and Environmental Specifications".
LIST OF SUPPORTED MODELS
List of GP
Series Product
Generic name for the GLC Series of Graphic Logic Controllers
made by Digital Electronics Corporation.
LIST OF SUPPORTED MODELS
List of
GLC Series Product
GP
GLC
This manual uses the following symbols and terminology.
If you have any questions about the contents of this manual, please contact your
local GP distributor.
Also, If you have any question about your personal computer or Windows, please
contact your PC distributor or manufacturer.
Safety Symbols and Terms
This manual uses the following symbols and terms to identify important informa-
tion related to the correct and safe operation of this product.
General Information Symbols and Terms
This manual uses the following symbols and terms for general information.
MANUAL SYMBOLS AND TERMINOLOGY
Symbol Description
Indicates a potentially hazardous situation that could result in serious injury
or death.
Indicates a potentially hazardous situation that could result in minor injury or
equipment damage.
Indicates a potentially damaging action or dangerous situation that could
result in abnormal equipment operation or data loss.
Indicates instructions or procedures that must be performed to ensure
correct product use.
Indicates instructions or procedures that must not be performed.
MANUAL SYMBOLS AND TERMINOLOGY
Esc Ctrl
17
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
Type
Symbol PS/2 Compatible
101 Keyboard
Esc
Tab
Ctrl
-Shift
Alt
Delete
Backspace
Keyboard Compatibility List
This manual uses the following symbols to indicate computer keyboard keys.
The key names used by your computer keyboard may differ. Please use the chart
below for reference.
Typical User Configuration
This manual's description of this software's operating procedures and features is
based on the PC system configuration shown below.
If you use a different configuration, the PC and GP screens, as well as the names
used for pre-made Parts may differ. In this case, please substitute the equivalent
screen and part names of your system for those given in this manual.
Esc
Tab
Ctrl
Shift
Alt
Delete
Back
space
MANUAL SYMBOLS AND TERMINOLOGY
Hardware/Software Specification Remarks
Personal Computer Windows compatible
Memory 32MB
Mouse Windows compatible mouse
Windows 98
Device Mitsubishi MELSEC AnA series (Link)
GP GP-2600T
Connection between
the GP and PC RS-232C
Recommended Cable:
GPW-CB02
Made by Digital Electronic
s
Corporation
18 GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
CD-ROM Usage Precautions
To prevent CD-ROM damage or malfunctions, please observe the following
instructions:
Do not remove the CD-ROM from the CD-ROM drive while the drive’s opera-
tion lamp is lit.
•Do not touch the CD-ROM recording surface.
•Do not place CD-ROMs in a place where they may be exposed to extremely
high or low temperatures, high humidity, or dust.
Product Usage Precautions
To prevent program malfunction or accidents, be sure to observe the following
instructions:
Touch panel switches should NOT be used for
a device’s Emergency Stop Switch. Minister of
Health, Labour and Welfare speaking, all indus-
trial machinery/systems must be equipped with
a mechanical, manually operated emergency
stop switch. Also, for other kinds of systems,
similar mechanical switches must be provided
to ensure safe operation of those systems.
Do not turn off your personal computer’s power switch during the execution
of a program.
After you create a screen with this product and transfer it to the GP unit, do
not send the same screen from the GP to a DOS version of this screen
editor software (e.g. GP-PRO/PB III, GP-PRO III).
Do not change the contents of this product’s project files using the Text
Editor software.
Do not send a screen to a GP unit if that GP does not support the functions
provided by your screen editor software.
PRECAUTIONS
!!
!!
!
Warning
PRECAUTIONS
19GP-PRO/PB III for Windows Ver. 6.3 Operation Manual
GENERAL GP RESTRICTIONS
GENERAL GP RESTRICTIONS
The GP-PRO/PB III for Windows software displays screen data using your
personal computers fonts and graphic functions. Therefore, there may be a
slight difference between the data displayed on your personal computer and
the data displayed on the GP unit after that screen data is sent to the GP.
When characters are positioned on a tiling pattern, they may not be displayed
properly on the GP unit if the dot pattern of the characters matches that of the
tiling pattern and the characters are positioned on the same color. To solve the
problem, shift the characters by one dot.
When a GP unit is vertically installed, the panel’s coordinates will differ from
those used on the screen editor software. Therefore, when you enter screen
coordinates using tags or D-Script, please consider the GP’s orientation.
Software and GP Setting Controls
Certain functions and setting supported by the GP unit are not supported by
the GP-PRO/PB III for Windows program, and vice versa.
[Setting and functions items set via the GP unit (Not by GP-PRO/PB III
for Windows) ]
- Language Font selection
- GP Date/Time
- GP Self-Diagnosis Function
- Functions for adjusting the Video Display
[Functions and setting items supported by GP-PRO/PB III for Windows
only (Not by the GP unit)]
The following settings are included in the “GP System Settings” area:
- “Checksum Verification”
- “Buzzer Output”
- Screen Change Order in hierarchical display mode
- Turning the "Common Password" On/Off
- Screen Change according to standby mode time
- Shift to OFFLINE mode
- “K-tag” processing
- GP unit’s internal memory (LS area) backup function
- “Error Display Reset”
- “Watchdog” (Monitoring the communication status between the GP and
the device)
(0. 0) on the screen editor software
(0. 0) on the GP series’ panel
Double-byte characters used in a project may not display correctly when
displayed in a single-byte drawing environment. If you intend to use your
screen data in a single-byte environment, be sure to use only single-byte
characters for screen text.
Data should be edited using the same environment (OS) it was created with.If
a different OS is used, characters may change or be unreadable.
GP-PRO/PB III for Windows Ver. 6.3 Operation Manual20
GENERAL GP RESTRICTIONS
- Address setting for "CF Card Control Setting" (Data Storage/Space
Storage Address/SRAM Auto Backup)
- “Q-tag” settings (Display format, Print Settings, and Alarm Trigger
Count Write’s Start Address/Processing Performed at GP power-ON/
Perform External Operations/Q-tag: Time Character addition (format)
- Communication Monitoring Period settings (Designate transmission wait time)
- Data Backup
- Display Colors
- FEP Setting
- Serial code reader (LS storage start address/Read complete bit ad-
dress/Data storage setting)
- The Control Word Address setting for the "Screen Capture" function
- "Print Type" (Setting the print function with the tool connector)
This feature is only available with GLC2300 Series units.
- The following GP/PRO/PB III for Windows features, even though they can
be set using the GP-PRO/PBIII software, are currently not supported for
the following PLCs. Tag Reference Manual
Be sure to check that your type of PLC supports the features you wish
to use on the GP prior to creating your GP-PRO/PBIII for Windows
project data.
<Functions of GP-PRO/PB III for Windows Ver. 6.3>
O : Supported
: Depends on the type X: Not supported:
When a device/PLC shown in the table below is connected, some GP settings
and software features may be limited.
Before creatingnew screens, see the table below.
Device/PLC Connection Manual
Rockwell (Allen-Bradley) Modicon
Specified
in: Item SLC500/PLC-5
DataHighway+
PLC-5
Remote I/O
SLC500
DH485 Modbus
Slave Modbus
Plus
Communication setting X*1 X
*1 X
*1 O X*1
GP Operating environment X*1 X
*1 *2 O X*1
Use System Area O X O O O
Use Read Area O X O O O
E-tag, K-tag: Indirect setting X X X O X
H-tag: Read after startup X X O O X
S-tag: Read after startup X X O O X
Trend graph "block display" X*4 X O O X*4
D-script: Memory Copy X X O O X
D-script: Address Offset
Designation X X O O X
Filing data function X X O O X
CSV data transfer function X X O O X
Logging function X X O O X
GP resetting due to write error
X X O X X
Data backup X X O O X
Software
2-Way driver *3 *3 *3 O *3
*1 These items can be set using [GP Setup] of GP-PRO/PB III for Windows.
*2 "maximum id" can be set using [GP Setup] of GP-PRO/PB III for Windows.
*3 Only the LS area can be used.
*4 Displays support available when Device/PLC Device Addresses are used.
Use of the GP LS Area’s Read Area is supported (“O”).
/