Sencor SHF 3000WH User manual

Category
Humidifiers
Type
User manual

Sencor SHF 3000WH is an innovative humidifier designed to improve indoor air quality and create a comfortable living environment. Equipped with a 3L water tank, it provides up to 12 hours of continuous operation, effectively adding moisture to the air. Choose between three mist intensity levels to customize the humidity output. The automatic mode intelligently adjusts the mist intensity based on the real-time humidity level, ensuring optimal comfort. The sleep mode operates quietly, creating a peaceful atmosphere for restful sleep.

Sencor SHF 3000WH is an innovative humidifier designed to improve indoor air quality and create a comfortable living environment. Equipped with a 3L water tank, it provides up to 12 hours of continuous operation, effectively adding moisture to the air. Choose between three mist intensity levels to customize the humidity output. The automatic mode intelligently adjusts the mist intensity based on the real-time humidity level, ensuring optimal comfort. The sleep mode operates quietly, creating a peaceful atmosphere for restful sleep.

03/2021
- 1 -
Copyright © 2021, Fast ČR, a.s.
EN Humidier
Translation of the original manual
SHF 3000WH
03/2021
- 2 -
Copyright © 2021, Fast ČR, a.s.
EN Humidifier
Important safety instructions
READ CAREFULLY AND STORE FOR FUTURE USE.
General warnings
This appliance may be used by children 8 years of age and
older and by persons with physical or mental impairments
or by inexperienced persons, if they are properly supervised
or have been informed about how to use the product in
asafe manner and understand the potential dangers.
Children must not play with the appliance. Cleaning and
maintenance performed by the user must not be performed
by unsupervised children.
In the event that the power cord is damaged, have it
repaired at aprofessional service centre to prevent causing
adangerous situation. It is forbidden to use the appliance
if it has adamaged power cord.
Always only fill only to the marked maximum water level
mark. Never fill the water past the maximum mark.
When filling, cleaning, descaling or when changing the
dehumidifier filter, always follow the included in this
user'smanual.
Be especially careful when using the appliance since it
generates steam.
When filling or cleaning the appliance, disconnect it by
pulling the power plug out of the power socket.
Understand that high levels of moisture may facilitate the
growth of biological organisms in the environment.
Do not permit the area around the humidifier to become
damp or wet. In the event that this happens, set the
03/2021
- 3 -
Copyright © 2021, Fast ČR, a.s.
humidifier to a lower power level. In the event that it
is not possible to lower the power of the humidifier, use
the humidifier intermittently. Do not permit absorptive
materials such as carpets, curtains, drapes or table cloths
to become wet.
Never leave water in the water tank when the appliance is
not being used.
Empty out and clean the humidifier before storing it. Clean
the humidifier before using it again.
Keep the appliance out of children's reach. Steam and
boiling water may cause scalding.
Before connecting the appliance to apower socket, check that the technical details on its rating label match the electrical voltage in the socket.
Ensure that the power socket is properly grounded. In the event that the adapter were to be incorrectly connected in the power socket, it could heat up
excessively and be subsequently damaged.
Guide the power cord so that nobody can trip over or step on it, to prevent its damage and tilting over of the appliance in the event that the power cord is
pulled.
The appliance is designed for use in households, offices or similar types of areas.
Always install the appliance on an even, dry and stable surface.
Do not place the appliance in the vicinity of an open flame, gas appliances or devices that are sources of heat or expose it to direct sunlight.
Do not place any items on the appliance, do not sit or stand on the appliance.
Do not use the appliance in rooms where there is arisk of flammable gases or chemical vapours leaking or in rooms that are very dusty. When the appliance
is running, it must be located at asufficient distance from curtains or drapes and at least 2 metres from electrical or electronic devices or materials sensitive to
moisture in order not to damage them by the effect of increased humidity.
Do not use the appliance in locations or rooms where insecticides, oil-based or chemical agents were used, or where afragrance stick was lit.
Always use original parts and accessories specified by the manufacturer. Never replace any part of this appliance with parts or accessories from another
manufacturer.
Only fill the water tank with clean cold water without any additions. Do not pour water into the water tank through the steam outlet. Do not pour hot water
into the water tank.
Do not drink the water from the water tank, do not water flowers with it or provide it as drinking water to household pets. Always pour out any unused water
down the sink or drain.
Before putting the appliance into operation, check that it is properly assembled and that the water tank is filled.
Do not cover the appliance when it is in operation, particularly the steam outlets. Do not place any items into the steam outlets or into the vents. Make sure
that these openings are not blocked by foreign objects.
As aresult of increased humidity in the room, water may condensate on window panes or interior furnishings. If this situation arises, turn the appliance off.
Never tilt the appliance, move the appliance, disassemble or add water into an empty water tank, when it is in operation.
In the event that you need to move, clean, disassemble the appliance or add water to it, always first turn it off and wait for it to cool down and then disconnect
the power plug from the power socket.
Bacteria or moulds may form on the humidifying filter when the appliance is not used for an extended period of time and when it is incorrectly cleaned prior
to storage. For this reason, before putting the appliance into operation again, check the humidifying filter to see whether it is clean and that there are no signs
of mould. Otherwise it is necessary to replace it.
Clean the water tank and the humidifying filter every week. In the event of more frequent use, you may also clean it twice per week.
Do not use cleaning products, petrol, window cleaners, furniture cleaning agents, solvents or any other chemical agents to clean the appliance.
Be especially careful not to spill water when carrying the appliance with water in the water tank.
To avoid potential injury by electrical shock, do not submerge any part of the appliance'sbase unit in water or any other liquid.
Do not disconnect the appliance from the power socket by pulling on the power cord. This could damage it or the power socket. Always disconnect by pulling
on the adapter.
Do not use the appliance if it is damaged, if the adapter has adamaged power cord or power plug.
In no case should you attempt to repair the appliance yourself, do not make any modifications to it – danger of injury by electrical shock! Entrust all repairs
and adjustments to aspecialised company/service. Failure to do so will expose you to the risk of voiding the warranty policy.
03/2021
- 4 -
Copyright © 2021, Fast ČR, a.s.
SHF 3000WH
A1
2
3
4
5
6
7
8
9
10
11
12
03/2021
- 5 -
Copyright © 2021, Fast ČR, a.s.
B
AUTO
AUTOSLEEP
TURBO
LIGHT
I II III
FILTER RESET
ON/OFF
5
4
321
- 6 - 03/2021
Copyright © 2020, Fast ČR, a.s.
EN Humidifier
User'smanual
Prior to using this appliance, please read the user'smanual thoroughly, even in cases,
when one has already familiarised themselves with previous use of similar types of
appliances. Only use the appliance in the manner described in this user’smanual.
Keep this user'smanual in asafe place where it can be easily retrieved for future use.
We recommend saving the original cardboard box, packaging material, purchase
receipt and responsibility statement of the vendor or warranty card for at least the
duration of the legal liability for unsatisfactory performance or quality. In the event
of transportation, we recommend that you pack the appliance in the original box
from the manufacturer.
DESCRIPTION OF THE APPLIANCE
A1 Steam outlet
A2 Control panel
A3 Motor unit with afan
A4 Power adapter connection socket
(located at the rear)
A5 Float switch limiter
A6 Float switch
A7 Humidifying filter
A8 Motor unit release clip
A9 Vents
A10 Water tank
A11 Water level with MAX mark
A12 Power adapter
DESCRIPTION OF THE CONTROL PANEL
B1 Button - illumination / sleep
mode selection
B2 Button AUTO - automatic mode
selection
B3 Button - fan speed selection
B4 Humidifying filter replacement
indicator light
B5 Button - On / Off
BEFORE FIRST USE
Before first use, take the appliance and its accessories out of the packaging material
and remove all promotional labels and stickers. Check that neither the appliance nor
any of its parts is damaged.
Filling the water tank
1. Place the appliance on afirm, level and water-resistant surface. To achieve better
performance, check that the appliance is located at least 10 cm away from walls.
2. To ensure optimal operation, ensure that neither the vents nor the steam outlets are
blocked.
3. Ensure that neither the power adapter cord nor its plug are damaged.
4. Press the safety clip A8 and carefully lift up the motor unit A3.
5. In the event that there is aprotective cover on the humidifying filter A7, take it off
and remove the float switch A6.
6. Pour clean cold water into the water tank A10 up to the MAX mark.
7. Insert the float switch A6 and then insert the humidifying filter A7 with the limiter
A5 attached so that the float switch A6 can freely move through the hole in the
middle.
8. Put the motor unit A3 back on.
9. Insert the connector of the power adapter A12 into the socket A4 and insert the
power adapter plug into aproperly grounded power socket. Asound is made and
the humidifier is ready for use.
Turning on / off
Press button B5 to start the humidifier. The humidifier will automatically start
at speed II. The backlight underneath the control panel A2 will gradually change
through all the colours. The indicator lights "LIGHT" and "II" will be lit blue.
When not using the humidifier, press button B5 to turn the humidifier off.
Button
Button B1 serves to turn the coloured backlight on and off, and to turn the sleep
mode on and off. Repeatedly pressing the button will change the functions of the
humidifier in the following order:
- First press: indicator light "LIGHT" will flash three times, which indicates achange
in the mode. It is important to make the next press while the indicator light "LIGHT"
is flashing. Otherwise your desired change will not happen and the humidifier will
return to the mode used previously.
- Second press: activate the sleep mode. The indicator light "SLEEP" will start
flashing 10 times and then turn off the backlight and all the indicator lights. In the
sleep mode, the fan speed is set to "I" (lowest speed).
It is important to make the next press while the indicator light "SLEEP" is flashing.
Otherwise your desired change will not happen and the humidifier will set itself to
sleep mode.
- Third press: cancel the sleep mode. The humidifier will operate at speed "I" and the
backlight will be turned off.
- Fourth press: turn on the backlight at the last set speed level. The indicator lights of
the set speed and the indicator light "LIGHT" will be lit.
Automatic mode
Press button AUTO B2 to activate the automatic mode. In this mode, the humidifier
will monitor and measure the ambient air humidity and adjust the fan speed
automatically to achieve the optimal air humidity relative to ambient air humidity.
- Humidity 0 – 45 RH %: fan speed III and ared backlight
- Humidity 45 – 65 RH %: fan speed II and ablue backlight
- Humidity > 65 RH %: fan speed Iand an orange backlight
To cancel the automatic mode, press button AU TO B2.
Setting fan speed
Button B3 serves to set the fan speed. Repeatedly pressing the button will
change the speed of the fan in the following order: I(lowest speed) – II (middle
speed) – III (high speed) – TURBO (highest speed, where all the speed indicator
lights are lit).
Low water level indicator
As soon as the water level falls below the set level, the indicator light "ON/OFF" will
start flashing red.
Add water if necessary. Prior to adding water, check that the humidifier is turned
off and that the power adapter A12 is disconnected from the power socket. Then
you may continue according to the instructions in section "Filling the water tank".
When not using the humidifier, leave it turned on. The fan will remain in operation
even for several hours to ensure that the humidifying filter A7 is dried out, and then
it will stop automatically.
The fan will remain in operation for 7 hours (normal mode) or 10 hours (sleep mode)
and the indicator light "ON/OFF" will flash red for the entire time.
CLEANING AND MAINTENANCE
Disconnect the adapter power plug from the power socket and allow the appliance
to cool down before cleaning it.
For cleaning, do not use cleaning products with an abrasive effect, solvents, etc. that
could damage the appliance. No part of this appliance is intended for washing in
adishwasher.
Warning:
To prevent the risk of injury by electrical shock, do not submerge
the appliance, the adapter or its power cord in water or any
another liquid.
Regular cleaning
Regularly clean the appliance based on the amount of use. With standard use, clean
the humidifier once per week. The more frequently you use the humidifier, the more
frequently you will need to clean it.
1. Turn off the humidifier using button B5 and disconnect the power adapter A12
from the power socket.
2. Press the safety clip A8 and carefully lift up the motor unit A3.
3. Wipe the motor unit with asoft sponge lightly dampened in warm water. Wipe it
with adry wiping cloth.
4. Remove the humidifying filter A7 with the attached limiter A5 and float switch A6
from the water tank A10.
5. Rinse out the water tank with clean warm water and wipe it dry.
6. If necessary, rinse the float switch under clean running water and wipe it dry.
6. Rinse the humidifying filter A7 under clean running water. In the event of greater
soiling, you may soak it in clean water. The water temperature should not exceed
60°C, otherwise there is arisk that the filter A7 will change colour.
7. You can carefully squeeze the walls of the filter to remove any soils from the creases.
8. In the event that the filter A7 is heavily soiled, you can add asmall amount of
avinegar or fine alkaline cleaning product. Then thoroughly rinse it under running
water.
However, the cleaning time should not exceed 8 minutes.
Note:
None of the cleaning methods described above will affect the absorption
characteristics of the humidifying filter A7. The filter A7 can absorb alarge
amount of water during the cleaning process, which reduces its strength.
After being cleaned and dried, its strength returns to more than 85% of
the normal strength.
Removing limescale deposits
In the event that limescale deposits form in the water tank A10, use a1:1 vinegar-
water solution or asolution of avinegar-based cleaner with water at aratio of 1:3.
Apply the solution using asponge with which the inside of the water tank A10 is
wiped out. In the event of heavier soiling, you can pour the solution into the water
tank A10 and allow it to act for awhile. Then thoroughly rinse it with warm water.
- 7 - 03/2021
Copyright © 2020, Fast ČR, a.s.
Replacing the humidifying filter
When the indicator light "FILTER RESET" starts flashing, it is necessary to purchase
a new humidifying filter and replace it. The lifetime of the humidifying filter is
approximately 4,320 hours.
1. Turn off the humidifier using button B5 and disconnect the power adapter A12
from the power socket.
2. Press the safety clip A8 and carefully lift up the motor unit A3.
3. Take out the humidifying filter A7 and carefully take the limiter A5 out of it.
4. Take the new filter out of the protective package and place it on the limiter A5.
5. Insert anew humidifying filter A7 with the limiter A5 attached into the water tank so
that the float switch A6 can freely move through the hole in the middle.
6. Put the motor unit A3 back on.
7. Insert the connector of the power adapter into the socket A4 and insert the power
adapter plug into aproperly grounded power socket. Asound is made.
8. To reset the lifetime timer of the new filter A7, hold down button B5 for
approximately 3 seconds, until a sound is made and the indicator light "FILTER
RESET" turns off.
Storage
When not using the appliance for an extended period of time, disconnect the
connector of the power adapter A12 from the socket and the power adapter A12
from the power socket, allow the appliance to cool down and clean it according to
the instruction above.
Before storing it, check that the appliance and all its accessories are thoroughly
clean and dry, and that there is no water in the water tank A10. Ensure that the
humidifying filter is thoroughly dry, to prevent the formation of moulds and
bacteria.
Store the appliance in a dry, clean and well-ventilated location not exposed to
extreme temperatures and out of children'sreach.
TROUBLESHOOTING
It is not possible to turn on the humidifier.
- Check that the connector of the power adapter A12 is correctly inserted in the
socket A4 and that the power adapter A12 is correctly inserted in the power socket.
- Check that the humidifier is correctly assembled.
The indicator light "ON/OFF" is flashing red.
- There is not enough water in the water tank A10. Fill it up. Proceed according to the
instructions in section "Filling the water tank".
The humidifier becomes clogged and it is not possible to select any mode.
- Check that the humidifying filter A7 is correctly inserted.
- Check that the humidifying filter A7 is not excessively clogged with soils, and clean
it out if necessary.
- Check that there are no open windows or doors in the room, which would increase
the extraction of air.
- Check that the size of the room corresponds to the recommended size.
The indicator light "FILTER RESET" is flashing.
- It is necessary to replace the humidifying filter A7. Proceed according to the
instructions in section "Replacing the humidifying filter".
Note:
In the event that the above do not describe your problem or if any of
the describe problems persist, turn off the humidifier and stop using it.
Contact an authorised service centre.
TECHNICAL SPECIFICATIONS
Power adapter
Input .................................................................................................... 100 – 240 V~, 50 / 60 Hz, 0.5 A
Output ................................................................................................................................. 12 V , 1 A
Humidifier
Rated power input ....................................................................................................... 12 V 12 W
Noise level ...............................................25 ± 3 dB(A) (low speed), 52 ± 3 dB(A) (high speed)
Water tank capacity ......................................................................................................................... 2.8 l
Humidifier output ....................................................................................................................300 ml/h
Operating time per single water tank ............................................................................... 10 hours
Recommended room area ..........................................................................................................44 m2
Dimensions (w × d × h) .................................................................................... 236 × 236 × 341 cm
Length of power cord ................................................................................................................180 cm
Weight ............................................................................................................................................... 2.1 kg
The declared noise emission level of the appliance is 25 ± 3 dB(A) (low speed),
52±3dB(A) (high speed), which represents alevel Aof acoustic power with respect to
areference acoustic power of 1 pW.
Safety class for electrical shock protection:
Class II – Electrical shock protection is provided by double or
heavy-duty insulation.
The product is intended for household use only. The product is
not intended for outdoor use.
We reserve the right to change text and technical specifications.
INSTRUCTIONS AND INFORMATION REGARDING THE
DISPOSAL OF USED PACKAGING MATERIALS
Dispose of used packaging material at asite designated for waste in your municipality.
DISPOSAL OF USED ELECTRICAL AND ELECTRONIC
EQUIPMENT
This symbol on products or original documents means that used
electric or electronic products must not be added to ordinary
municipal waste. For proper disposal, renewal and recycling, hand
these products over to determined collection points. Alternatively, in
some European Union states or other European countries you may
return your appliances to the local retailer when buying an equivalent
new appliance.
Correct disposal of this product helps save valuable natural resources
and prevents potential negative effects on the environment and human health, which
could result from improper waste disposal. Ask your local authorities or collection
facility for more details.
In accordance with national regulations penalties may be imposed for the incorrect
disposal of this type of waste.
For business entities in European Union states
If you want to dispose of electric or electronic equipment, ask your retailer or supplier
for the necessary information.
Disposal in other countries outside the European Union.
This symbol is valid in the European Union. If you wish to dispose of this product,
request the necessary information about the correct disposal method from the local
council or from your retailer.
This product meets all the basic requirements of EU directives related to
it.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Sencor SHF 3000WH User manual

Category
Humidifiers
Type
User manual

Sencor SHF 3000WH is an innovative humidifier designed to improve indoor air quality and create a comfortable living environment. Equipped with a 3L water tank, it provides up to 12 hours of continuous operation, effectively adding moisture to the air. Choose between three mist intensity levels to customize the humidity output. The automatic mode intelligently adjusts the mist intensity based on the real-time humidity level, ensuring optimal comfort. The sleep mode operates quietly, creating a peaceful atmosphere for restful sleep.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI