Foundation Armor UTN603GAL is a high-gloss industrial coating designed to protect interior concrete surfaces from deterioration, stains, and chemicals. It provides a long-lasting, UV-stable finish that resists wear, oil, gas, and harsh liquids. Ideal for garage floors, warehouses, retail spaces, and more. Easy to apply and maintain, with up to 10 years of life before recoating.

Foundation Armor UTN603GAL is a high-gloss industrial coating designed to protect interior concrete surfaces from deterioration, stains, and chemicals. It provides a long-lasting, UV-stable finish that resists wear, oil, gas, and harsh liquids. Ideal for garage floors, warehouses, retail spaces, and more. Easy to apply and maintain, with up to 10 years of life before recoating.

PRODUCT DESCRIPTION
BENEFITS/FEATURES
SUGGESTED APPLICATIONS
TECHNICAL INFORMATION
COVERAGE
SHELF LIFE
PACKAGING
The Armor UTN60 is a commercial grade, solvent-based, high gloss aliphatic urethane coating is designed to enhance and pro-
tect a variety of interior surfaces from deterioration, oil and gas stains, harsh liquids and chemicals. It is manufactured in the
U.S., and made from high quality resins and solvents. The Armor UTN60 will provide a long-lasting, UV-stable high gloss fin-
ish that wont peel, chip, or flake. It is available in clear, as well as several color options. Non-slip additives and matte packs are
available.
Abrasion Resistance………………...……………...35 mg loss
(Tabler Index, ASTM 4060-81, CS-17 Abrasion Wheel, 1000 gram load)
Gloss 60…….............................................................90-95
Flexibility (1/8” Mandrel).........................................Pass
Hardness - Shore D....................................................62
Water Resistance.......................................................Excellent
Solids % Weight (Federal Spec. TTP-141B).............60%
Density lbs/Ga. (Federal Spec. TTP-141B)...............8.49
VOC ………………………………………………..< 250 g/l
When properly sealed and stored, the shelf life of the UTN60 is up to 1 year.
The Armor UTN60 is available in 3 Gallon Kits and 15 Gallon Kits.
First Coat (Mixed 3-gallon kit) 750-900 ft
2
/3 gallon kit
Second Coat (Mixed 3-gallon kit) 800-1000 ft
2
/3 gallon kit
Coverage rates will vary depending upon surface porosity and texture, and application method. Excessive build up should be avoided.
Mix Ratio (a/b volume)....................................2 to 1
Coverage (3-5 mils dft.)................. .................250-340 sq. ft./ga
Viscosity..........................................................400-600 cps
Pot Life.............................................................25-30 minutes
Dry Time-Set to Touch……………….............8-10 hours
Dry Time-Recoat…..........................................10 - 14 hours
Dry Time-Foot Traffic.......................................24 - 36 hours
Dry Time-Wheel Traffic....................................3 - 5 days
Application temperature…...………….…….....45-85 degrees F
Armor UTN60 High Gloss Industrial Coating
Foundation Armor
472 Amherst Street #14
Nashua, NH 03063
(866) 306-0246
FoundationArmor.com
For Professional Use
Provides a long-lasting, UV stable high gloss finish
Reduces deterioration caused by surface abrasion
Offers excellent long term wear resistance
Stops concrete surface stains
Resists oil, gas, harsh liquids, and chemicals
Easy to apply and maintain.
Can provide up to 10 years of life before the need for a recoat.
Stops concrete dusting
Interior concrete floors that have been diamond-ground to a
25-80 grit finish (concrete surface profile 3).
Garage and shop floors, aircraft hangar floors
Warehouse and manufacturing plant floors
Kennel floors
Retail and showroom floors
CHEMICAL RESISTANCE
NO EFFECT: Urine, Blood, Xylene, Gasoline, Oil, Skydrol B-4, Ethylene Glycol, MEK, 10% and 50% Sodium Hydroxide, 25% Sulfuric
Acid, 25% Acetic Acid, 20% Nitric Acid, 10% Hydrochloric Acid.
PLEASE NOTE: A chemical exposure test should always be performed prior to application to ensure satisfactory resistance.
APPLICATION INSTRUCTIONS
CLEAN-UP
PRODUCT REMOVAL
PRECAUTIONS AND LIMITATIONS
SURFACE PREPARATION: Surface preparation is key to the success and life of the UTN60. UTN60 must be applied to fully cured unsealed interior concrete that has been properly prepped with a
diamond grinder to a 25-80 grit finish (concrete surface profile 3). Surface needs to be completely dry and free of oil, dirt, grime, wax, detergent or any incompatible paint or coating.
If applying the Armor UTN60 as a top coat over the Armor Epoxy Primer, UTN60 must be applied within the recoat window of the Armor Epoxy. If applying the UTN60 to an existing coating, it is im-
portant to first speak with a Foundation Armor Technician regarding compatibility, required surface preparation and application.
Product Mixing
Clear UTN60: Slow drill mix 2 Parts A with 1 Part B in a clean 5 gallon pail. Mix for 60-90 seconds, or until material is thoroughly blended and homogenous. Avoid whipping air into the coating. Im-
proper mixing can result in coating failure.
UTN60 w/Color Pack: Before adding in Part B, slow drill mix color into pre-mixed Part A for roughly 30 seconds. 4.5-6 oz. of color should be added to each gallon of material. For example, if you are
mixing a 3 gallon UTN60 kit, you would mix in a total of 13.5-18 oz of color. Once the color has been mixed into Part A, add in Part B and slow drill mix for 60-90 seconds, or until material is thorough-
ly blended and homogenous
Non-Slip: For best results, apply the Armor non-slip additive with an appropriate hand-held broadcast spreader. When applying the second coat, add the non-slip additive to the coating using a broad-
cast spreader, and back roll to encapsulate the non-slip additive.
Product Application
Apply the mixed material using a 3/8” shed-less nap roller. It is important to apply within estimated pot life and recommended temperature guidelines. Please note that pot life may vary. If the material
becomes thick while applying, or starts sticking to the roller , stop applying and discard the mixed material. At this point it has reached the end of the usable pot life. While applying keep a wet edge to
prevent roller marks. It is recommended to work in sections usually using control joints as dividers to ensure proper application results. Do not allow to Puddle! If recoating after 24 hours you must wait
5-7 days to allow the coating to cure. Once 5-7 days has passed, a light sanding using an 80 grit screen pad (and a thorough surface cleaning) is required prior to applying an additional coat to ensure
adequate coat adhesion.
Blending roller lines: When rolling the UTN60 it is considered a best practice to lift the roller at the end of the stroke so there are no roller lines/stop lines. Applying the UTN60 is very similar to apply-
ing paint, be sure to always maintain a wet edge. Work fast, but controlled, you only have about 25-30 minutes of working time before the pot life is reached.
PLEASE NOTE:
When applying the UTN60 in a color, you may see small areas of concrete through the first coat of material. Applying a second color coat will help to achieve a consistent opaque surface finish.
The UTN60 should be applied in thin, even coats. Do not attempt to apply large amounts of material in an attempt to fill in concrete cracks, holes, divots, or surface imperfections.
Applying UTN60 outside of the suggested parameters may result in application failure. It is always recommended to test the product in a small, inconspicuous area (on the same concrete substrate)
for desired results prior to application. Coverage rates may vary for all coatings and substrates depending on porosity, density, texture etc.
The applicator is responsible for suitability of application, and the results of the application. We suggest applying to a test area first to verify compatibility, absorption, coverage rate, and project suita-
bility.
Use MEK. Dispose of containers in accordance with local and federal regulations.
Dried, cured sealer may be removed with a commercial paint stripper, or by using a diamond grinding method, sandblasting method or similar
mechanical action.
Concrete must be cured for at least 28 days.
Coverage rates depend upon many conditions including application method, surface porosity, and applicator.
Armor UTN60 should be applied in thin coats, it is not designed as a high build coating. Do not puddle.
Be aware that this product may be slippery when wet. Non-Slip additives are available.
Armor UTN60 may darken the surface of many new and existing concrete substrates. Test prior to use.
Physical properties listed on this technical data sheet are typical values, not specifications.
Do not let sweat or other liquids come into contact with the uncured coating.
Do not apply to exterior concrete surfaces.
Do not apply to anything other than interior unsealed poured and properly prepped concrete.
It is recommended to wear the proper personal protective equipment when applying this product.
Properly protect and cover any areas not intended or suggested to be sealed during application.
•• If applying over an existing coating, proper adhesion and compatibility tests are essential. In this application the substrate preparation, application, performance and all other
liabilities are strictly the end users responsibility. Foundation Armor also offers no guaranty, warranty or other claims to the success or results of a job or project.
CONTACT
Still have questions? Contact a Foundation Armor Technician at 866-306-0246.
  • Page 1 1
  • Page 2 2

Foundation Armor UTN603GAL User manual

Type
User manual

Foundation Armor UTN603GAL is a high-gloss industrial coating designed to protect interior concrete surfaces from deterioration, stains, and chemicals. It provides a long-lasting, UV-stable finish that resists wear, oil, gas, and harsh liquids. Ideal for garage floors, warehouses, retail spaces, and more. Easy to apply and maintain, with up to 10 years of life before recoating.