netvox R711 User manual

Type
User manual

The netvox R711 is a wireless temperature and humidity sensor that uses LoRaWAN open protocol (Class A) to transmit data over long distances with low power consumption. It's easy to set up and install, and it can be used to monitor indoor air temperature and humidity. The R711 also has a low-power alarming feature that will notify you if the battery voltage drops below 2.4V.

The netvox R711 is a wireless temperature and humidity sensor that uses LoRaWAN open protocol (Class A) to transmit data over long distances with low power consumption. It's easy to set up and install, and it can be used to monitor indoor air temperature and humidity. The R711 also has a low-power alarming feature that will notify you if the battery voltage drops below 2.4V.

ModelR711
Wireless Temperature and Humidity Sensor
Temperature and Humidity Sensor
User Manual
1
Table of Content
1. Introduction................................................................................................................................................................ 2
2. Appearance................................................................................................................................................................. 3
3. Main Features............................................................................................................................................................. 3
4.Set up Instruction.........................................................................................................................................................4
4.1 Power on and Turn on / off...............................................................................................................................4
4.2 Join Into Lora Network.................................................................................................................................... 4
4.3 Function Key.................................................................................................................................................... 4
4.4 Data Report.......................................................................................................................................................4
5. Restore to Factory Setting.......................................................................................................................................... 5
6. Sleeping Mode............................................................................................................................................................5
7. Low Voltage Alarming............................................................................................................................................... 6
8. MyDevice Dashboard Demonstration........................................................................................................................6
9. Important Maintenance Instruction............................................................................................................................ 6
10. FCC Certification Statement.................................................................................................................................... 7
2
1. Introduction
R711 is a long distance wireless temperature and humidity sensor based on LoRaWAN open protocol (Class A).
LoRa Wireless Technology:
LoRa is a wireless communication technology dedicated to long distance and low power
consumption. Compared with other communication methods, LoRa spread spectrum modulation
method greatly increases to expand the communication distance. Widely used in long-distance,
low-data wireless communications. For example, automatic meter reading, building automation
equipment, wireless security systems, industrial monitoring. Main features include small size, low
power consumption, transmission distance, anti-interference ability and so on.
LoRaWAN:
LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure
interoperability between devices and gateways from different manufacturers.
3
2. Appearance
3. Main Features
Compatible with LoRaWAN
2 section 1.5V AA Alkaline battery
Report voltage status, temperature and humidity of indoor air
Easy set up and installation
Temperature / Himidity Sensor Probe
LED Indicator
Function Key
Battery Cover
4
4.Set up Instruction
4.1 Power on and Turn on / off
(1) Power on = Insert batteries: open the battery cover; insert two sections of 1.5V AA batteries and
close the battery cover.
(2) If the device had never joined in any network or at factory setting mode, after powering on, the
device is at off mode by default setting. Press function key to turn on the device. The green indicator
will flash green once to show that R711 is turned on.
(3) Press and hold function key for 5 seconds till the green indicator flashes quickly and release.
The green indicator will flash 20 times and enter off mode.
(4) Remove batteries (power off) when R711 is on. Wait till 10 seconds after the capacitance
discharging. Insert batteries again, R711 will be setted to be previous mode by default. There is not
need to press function key again to turn on the device. The red and green indicators will both flash
and then light off.
Note:
1. The interval between shutting down twice or power off/on is suggested to be about 10 seconds to
avoid the interference of capacitor inductance and other energy storage components.
2. Do not press function key and insert batteries in the same time, otherwise, it will enter engineer
testing mode.
4.2 Join Into Lora Network
To join R711 into LoRa network to communicate with LoRa gateway
The network operation is as following:
(1) If R711 had never joined any network, turn on the device; it will search an available LoRa
network to join. The green indicator will stay on for 5 seconds to show that it joins into the network,
otherwise, the green indicator does not work.
(2) If R711 had been joined into a LoRa network, remove and insert the batteries to re-join the
network. Repeat step (1).
4.3 Function Key
(1) Press and hold function key for 5 seconds to reset to factory setting. After restoring to factory
setting successfully, the green indicator will flashes quickly 20 times.
(2) Press function key to turn on the device; the green indicator flash once and it will send a data
report.
4.4 Data Report
When the device is turned on, it will immediately send a version package and a data report of
5
temperature/humidity/voltage. The transmission frequency of data report is once every hour.
Temperature default report value: mintime = maxtime = 3600s, reportchange = 0x0064 (1 ),
Humidity default report value: mintime = maxtime = 3600s, reportchange = 0x0064 (1%),
Battery voltage default report value: mintime = 3600s maxtime = 3600s, reportchange = 0x01
(0.1V).
Note: MinInterval is the sampling period for the Sensor. Sampling period >= MinInterval.
Data report configuration and sending period are as following:
5. Restore to Factory Setting
R711 saves data including network key information, configuration information, etc. To restore to
factory setting, users need to execute below operations.
1. Press and hold function key for 5 seconds till the green indicator flashes and then release; LED
flashes quickly 20 times.
2. R711 will enter off mode after restoring to factory setting. Press function key to turn on R711 and
to join a new LoRa network.
6. Sleeping Mode
R711 is designed to enter sleeping mode for power-saving in some situations:
(A) While the device is in the network → the sleeping period is 3 minutes. (During this period,
if the reportchange is larger than setting value, it will wake up and send a data report).
(B) When it is not in the network to join → R711 will enter sleeping mode and wake up every
15 seconds to search a network to join in the first two minutes. After two minutes, it will wake
up every 15 minutes to request to join the network.
If it’s at (B) status, to prevent this unwanted power consumption, we recommend that users
remove the batteries to power off the device.
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable
Change
Current Change≥
Reportable Change
Current Change
Reportable Change
Any number
between 1~65535
Any number
between 1~65535 Can not be 0. Report
per Min Interval
Report
per Max Interval
6
7. Low Voltage Alarming
The operating voltage threshold is 2.4V. If the voltage is lower than 2.4V, R711 will send a
low-power report to the Lora network.
8. MyDevice Dashboard Demonstration
9. Important Maintenance Instruction
This device is NOT truly waterproof/ resistant and is for indoor use.
Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or
moisture can contain minerals that corrode electronic circuits. In cases of accidental liquid spills
to a device, please leave the device dry properly before storing or using.
Do not use or store the device in dusty or dirty areas.
Do not use or store the device in extremely hot temperatures. High temperatures may damage
the device or battery.
Do not use or store the device in extremely cold temperatures. When the device warms to its
normal temperature, moisture can form inside the device and damage the device or battery.
Do not drop, knock, or shake the device. Rough handling would break it.
Do not use strong chemicals or washing to clean the device.
Do not paint the device. Paint would cause improper operation.
Handle your device, battery, and accessories with care. The suggestions above help you keep your
7
device operational. For damaged device, please contact the authorized service center in your area.
10. FCC Certification Statement
The OEM integrator has to be aware of not to providing information to end users regarding how to install or
remove this RF module in the user manual of the end product.The user manual which is provided by OEM
integrators for end users must
Include the following information in a prominent location.
“ To comply with FCC RF exposure compliance requirement, the antenna user for this transmitter must be
installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating
in conjunction with any other antenna or transmitter .”
Label for the end product must include “Contains FCC ID :NRH-ZB-Z100B”or “A RF transmitter inside,FCC
ID :NRH-ZB-Z100B”.
You are cautioned that changes or modifications not expressly approved by the party responsible for compliance
could void your authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is to the following two conditions:(1)this device
may not cause harmful interference and (2)this device must accept any interference received, including interference
that may cause undesired operation.
FCC RF Radiation Exposure Statement:
1This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
2.This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and
your body.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

netvox R711 User manual

Type
User manual

The netvox R711 is a wireless temperature and humidity sensor that uses LoRaWAN open protocol (Class A) to transmit data over long distances with low power consumption. It's easy to set up and install, and it can be used to monitor indoor air temperature and humidity. The R711 also has a low-power alarming feature that will notify you if the battery voltage drops below 2.4V.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI