  • Hello! I've reviewed the document you've provided, which contains instructions for testing and replacing a switch in a WarmlyYours towel warmer. The document includes step-by-step procedures, diagrams for wiring, and multimeter readings to verify the switch functionality. I am ready to answer your questions about the process and the device described in the document.
  • What is the first step in testing the switch?
    What should I do after pulling out the switch assembly?
    What does a resistance greater than 1 and a tone indicate when using a multimeter?
Installation Support • (800) 875-5285 • www.WarmlyYours.com
WarmlyYours
Be Connected.
Be Warm. Be Radiant.
Towel Warmer Switch Testing
and Replacing Instructions for
Hardwired Only Models
Testing the switch:
Step 1: Pull the switch assembly out.
Step 2: Unplug the switch assembly from the towel warmer connector.
Step 3: Place the switch in the “ON” position.
Step 4: Set the multimeter to ohm resistance (tone setting) and test between the NO (normally open center
prong) and C (common) prong. Any resistance value greater than 1 and a tone would indicate normal
operation. “1” , “OL” ,“Ω”, “0” and “no tone” would indicate that the switch is faulty and needs to be replaced.
Verify that the reading on the meter changes with each “ON” and “OFF” position change.
Replacing the switch:
Step 1: Pull the switch assembly out, label and disconnect the wires.
Step 2: Connect the wires to a new switch (SK15-59020-0000) in the same manner.
Step 3: Insert the switch into the towel warmer.
Note: All meters are not the same, information shown on the screen of the meter being used may
not match these instructions exactly.
NC
NO
C
NC
NO +
C
I O
I O
NC
NO
C
NC
NO +
C
I O
I O
NC
NO
C
NC
NO +
C
I O
I O
NC
NO
C
NC
NO +
C
I O
I O
NC
NO
C
NC
NO +
C
I O
I O
NC
NO
C
NC
NO +
C
I O
I O
Step 1
Step 1
Step 2
Step 2 Step 3
Step 4
Step 4
WHITE
WIRE
BLACK
WIRE
BLUE
WIRE
Test for continuity here.
When switch is depressed
(ON) meter will show
continuity if good.
No continuity when not
depressed (OFF)
C=Common
NO= Normally Open
Part #: SK15-59020-0000
/