Assembly Instructions
Column-mounted jib crane lift capacity = 650 kg with anchor
attachment
Information sheet for anchor attachments
Note: This information sheet was originally written in German and has been translated into English. It describes the basic
technical requirements for installing anchors and is intended to provide a quick start for experienced users. The anchor
installation must be carried out per the enclosed assembly instructions and detailed operating instructions. This information
sheet makes no claim to be exhaustive. Store in a safe place for future reference. Subject to technical changes without
notice. No responsibility is taken for printing or other types of errors.
J. Schmalz GmbH · Johannes-Schmalz-Str. 1 · 72293 Glatten, Germany · T: +49 (0) 7443 2403-0
EN · 30.30.01.02618 · 02 · 09/23
2 | EN EN · 30.30.01.02618 · 02 · 09/2023
1 Basic Specifications
Attachments using chemical anchors FHB dyn may only be carried out in accordance with the provisions of
the general building approval Z-21.3.1748. Non-compliance with the provisions leads to the exclusion from
responsibility and liability of the anchor manufacturer, supplier, and technician.
The transfer of loads from crane operation to the component via the anchor attachment must be verified by
the building contractor or his representative. Possible damage to the ceiling or floor reinforcements due to
drilling work, which has a static effect on the building structure, must be taken into account. If necessary, the
permitted position of the drilled holes for mounting must be indicated.
Schmalz will only perform mounting if all requirements have been met by the time of mounting and the mounting site
has been prepared accordingly. If the requirements are not met, alternative solutions must be found. If, during
mounting, it is determined that the requirements have not been fulfilled as stated in this confirmation, additional
costs will be charged to the client.
2 Technical Requirements
The following requirements apply to the attachment of cranes via anchoring. The criteria must be checked by the
building contractor or a person authorized by them:
Floor conditions
Yes
No
Concrete strength class must be:
min. C20/25, max. C50/60 according to DIN EN 206-1
min. B25, max. B55 according to old DIN 1045
The load-bearing capacity of the concrete floor to absorb the crane forces is verified
Freshly poured floors/ceiling are at least 4 weeks old
Anchoring ONLY in reinforced and unreinforced, cracked and non-cracked standard concrete;
no steel fiber concrete!
Environmental conditions
Constantly < 50° C in the area of the mortar; temperatures < 11° C for the installation lead to
increased installation times.
Closed and dry interior;
DO NOT use cleaning agents around the anchors.
Installation conditions
Leveling layers applied to the concrete (e.g. screed) are not permitted and must be removed
at least above the surface of the anchor plate +100 mm on each side (for mounting and
undergrouting).
Load-bearing component thickness and edge spacings (see following figure) are maintained
3 | EN EN · 30.30.01.02618 · 02 · 09/2023
DUE-SET-DYN-M12x100/25 (lift capacity 650kg)
Crane base plate thickness 10 mm
Required concrete floor thickness [D]
(without leveling layers)
Required edge spacing on all sides [R]
(also to expansion joints)
145 199 mm
≥ 200 mm
≥ 200 mm
≥ 100 mm
Drill hole depth [t]
120 mm
Drilling depth through
attachment
(crane base plate) [td]
130 mm
Rated drill diameter [d]
14 mm
Crane base plate thickness 15 mm
Required concrete floor thickness [D]
(without leveling layers)
Required edge spacing on all sides [R]
(also to expansion joints)
140 199 mm
≥ 200 mm
≥ 200 mm
≥ 100 mm
Drill hole depth [t]
115 mm
Drilling depth through
attachment
(crane base plate) [td]
130 mm
Rated drill diameter [d]
14 mm
Crane base plate thickness 20 mm
Required concrete floor thickness [D]
(without leveling layers)
Required edge spacing on all sides [R]
(also to expansion joints)
135 199 mm
≥ 200 mm
≥ 200 mm
≥ 100 mm
Drill hole depth [t]
110 mm
Drilling depth through
attachment
(crane base plate) [td]
130 mm
Rated drill diameter [d]
14 mm
Horizontal and
level concrete floor without
insulating layer, bitumen coating,
screed, or other floor coverings at a
distance of at least 100 mm around
the base plate of the crane column