  • Hello! I am an AI chatbot trained to assist you with the Emerson Liebert IntelliSlot Unity Communications Interface Card Case Studies. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Background
Growing global demand has driven Sidney, Ohio-based
Copeland Corporation to continue to boost production and
efficiency throughout its organization. Manufacturing automation
is one way the company responded to this challenge. Yet,
as manufacturing automation increased, the tolerance for
downtime decreased, making high availability network
protection a higher priority.
Case Summary
Locati
on:
Si
dney, Ohi
o
Products/Services:
• Liebe
rt GXT UPS
Liebert Intellislot OpenComms Web Card
Liebert Npo
wer UPS
Critical Needs: Deliver improved power availability to support
increasing manufacturing automation.
Results
Successful implementation of manufacturing
automation program.
100 percent perfect availability of remote network systems.
Increased visibility into remote business-critical
ne
t
w
or
k loca
tions.
Copeland
Corporation
A Customer Success
f
rom the Experts in
B
usiness-Critical Continuity™
Copeland Corporation, part of
Emerson Climate Technologies,
is a pioneer in the heating,
ventilation, air conditioning
and refrigeration industry
and is the world’s leading
manufacturer of compressors.
M03248_COPELAND CS_V2.2 10/11/06 4:17 PM Page 1
The Situation
An established leader in the HVACR industry,
Copeland produces high-efficiency compressors,
condensing units and electronics for commercial
refrigeration and residential and commercial air
conditioning applications. The company’s Copeland
Scroll™ compressor is renowned for its proven
pe
rformance, enhanced reliability and high efficiency.
In addition to a main computer room housing
mainframes and servers protected by a 130 kVA
Liebert Npo
wer UPS, the Si
dney facility has 17 network
closets in the main plant and seven at remote locations.
Network lines from both the office and factory come
into these sub-computer rooms, which hold Cisco
switches and routers to tie the shop-floor machines
to the main computer room.
Before the latest round of plant modernization began,
network closets were vulnerable to power loss. “In the
p
a
st, the only way we knew if we had an issue with a
UPS was if we had a power failure and the UPS would
not work,” says Phil Stickel, manager of Information
Systems at Copeland. “Sometimes switches wouldn’t
r
oll o
ver to UPS and other times we would discover
that the batteries were dead.
But as manufacturing automation increased, the
tolerance for downtime decreased. In response, Stickel
t
ook a h
ar
d look a
t the UPS s
y
s
t
e
ms supporting his
incr
e
a
singly mission-critical network devices.
“If the machines on the shop floor can’t communicate
with our SQL servers, we can’t make compressors,
Stickel says. “We could no longer be exposed to that
risk. We needed to deliver 100 percent uptime, and
w
e h
a
d to prove to management that we could
guarantee it.
The Solution
To develop a more proactive approach to power
management, Stickel and network engineer Cameron
Franklin consulted the SMS Group, a Liebert Solutions
Partner that provides systems integration solutions for
m
an
u
facturing businesses. The SMS Group worked
closely with the local Liebert Representative, Uptime
Solu
ti
ons, to deliver exceptional local support.
After analyzing the network closets, Sales Engineer
Mark Winner recommended replacing the existing
UPS s
y
s
t
ems with the Liebert GXT UPS. This
rack-mountable UPS delivers true fault-tolerant,
double-conversion power protection in a compact
si
z
e th
a
t is pe
r
f
ect for areas where space is at
a p
remium.
“With the Liebert UPS, I can now confidently
guarantee management that we will have
100 percent power to our systems.
Phil Stickel, Manager of Information Systems, Copeland
A Customer Success
from the Experts in
Business-Critical Continuity ™
Stickel (right) pictured here
with Cameron Franklin,
Network Engineer
M03248_COPELAND CS_V2.2 10/11/06 4:17 PM Page 2
Emerson. Consider It Solved is a trademark and Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks
o
f Eme
r
s
on Electric Co. ©2006 Emerson Electric Co.
0906
Emerson Network Power.
The global leader in enabling Business-Critical Continuity
.
A
C P
o
wer Systems
Connectivity
DC P
o
w
e
r Sy
stems
Embed
ded C
om
puting
Embedded Power
In
t
egr
a
t
ed Cabinet Solutions
O
u
tsi
de Plant
Power Switching & Control
Se
r
vi
ces
Site Monitoring
Pr
ec
isi
on C
oolin
g
EmersonNetworkPower.com
Surge & Signal Protection
A Customer Success
from the Experts in
B
usiness-Critical Continuity ™
The Liebert Intellislot OpenComms Card added
SNMP and Web-based management to the Liebert
GXT UPS systems. The card allows users to monitor
and control a Liebert UPS from a Network
M
anagement Station, or any Web-enabled PC.
The Results
Since standardizing on Liebert UPS in the network
closets, Stickel has met his 100 percent uptime goal,
even when an ice storm left the city of Sidney without
commercial power for several hours.
Stickel is especially pleased with the monitoring
capability of the Liebert UPS. “The monitors send an
alert if the UPS requires maintenance before we have a
utility power failure,” he says. “That way, we know our
UPS is always available, and so is our network. With
the Liebert UPS, I can now confidently guarantee
m
an
a
gement that we will have 100 percent power
t
o o
ur s
ystems.
Liebert GXT UPS