Raytheon TMC Converter, 121-061 Operating instructions

Type
Operating instructions

Raytheon TMC Converter, 121-061, is a device used for transmitting course information to repeater compasses or other nautical signal loads. It is commonly used by ships under 500 gross tons that want to install an electrical heading input for their autopilot and compass repeaters. Additionally, it can be used as an independent magnetic compass system to transmit compass information to heading repeaters.

Raytheon TMC Converter, 121-061, is a device used for transmitting course information to repeater compasses or other nautical signal loads. It is commonly used by ships under 500 gross tons that want to install an electrical heading input for their autopilot and compass repeaters. Additionally, it can be used as an independent magnetic compass system to transmit compass information to heading repeaters.

Raytheon Anschütz GmbH
Postfach 1166
D -- 24100 Kiel
Germany
Tel+49--431--3019--0
Fax+49--431--3019--501
www.raytheon --anschuetz.de
3756.DOC010002 Edition: July 9, 2004
Revision: Feb. 12, 2008
TMC--Converter
Type 121--061 NG001
1 Description
2 Operation
3 Installation
4 Maintenance and Repair
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich
zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz.
Copying of this document, and giving it to others and the use or
communication of the contents thereof, are forbidden without express
authority. Offenders are liable to the payment of damages.
Toute communication ou reproduction de ce document, toute
exploitation ou communication de son contenu sont interdites, sauf
autorisation expresse. Tout manquement à cette règle est illicite et
expose son auteur au versement de dommages et intérêts.
Sin nuestra expresa autorización, queda terminantemente prohibida la
reproducción total o parcial de este documento, así como su uso
indebido y/o su exhibición o comunicación a terceros. De los infractores
se exigirá el correspondiente resarcimiento de daños y perjuicios.
Compass
TMC--Converter
Type 121--061
I
3756.DOC010002
Edition: Feb. 12, 2008
Section Content Page
Declaration of Conformity
1 Description 1............................................................
1.1 Application 1............................................................
1.2 Technical data 2.........................................................
1.2.1 Mechanical data 2.......................................................
1.2.2 Electrical data 2.........................................................
2 Operating 3................................................................
3 Installation of the TMC--Converter 4........................................
3.1 Mounting of the TMC--Converter 4.........................................
3.2 Establishing of cable connections 5........................................
3.2.1 General remarks 5.......................................................
3.2.2 General information about establishing an earth connection 7.................
3.2.3 Connection of the cables 8................................................
3.3 Adjustments of the data formats 11.........................................
4 Maintenance and Repair 12................................................
4.1 Maintenance 12..........................................................
4.1.1 Alignment (sensitivity of magnetic sonde) 12.................................
4.1.2 Repair 14...............................................................
Anhang:
TMC Converter Dimensional Drawing 121--061. HP009
TMC Converter Wiring Diagram 121--061. HP011
TMC--I/O PCB Assembly Drawing with Configuration 121--061. HP101
TMC--Converter
Type 121--061
II
3756.DOC010002 Edition: Feb. 12, 2008
Compass
TMC--Converter
Type 121--061
1
3756.DOC010002Edition: July 9, 2004
1 Description
1.1 Application
The TMC--Converter (TMC = T
ransmitting Magnetic Compass) for transmitting the
course information to the repeater compasses or other nautical signal loads.
The TMC--Converter is suitable for:
-- ships under 500 gross tons, which need no gyro compass but want an electrical
heading input for the autopilot and want a heading input for the compass
repeaters.
-- ships, which need, additional to a gyro compass, an independent magnetic
compass system to transmit compass information to a heading repeater
(for example ships under Dutch flag).
The TMC--Converter, type 121--061 reads the heading data from a connected magnetic
sonde and disposes it, at in total 5 outputs, to connected heading receivers:
-- 2 outputs (adjustable) as NMEA 0183 or Course bus
NMEA --dataformat adjustable for 2 different transmission rates.
-- 3 outputs as Step--Signal with 6/Step, 35VDC
Magnetic sonde
Typ 108--010
TMC--Converter
121--061
24VDC
3 x Step--Signal 6/Step 35VDC
2 x NMEA or Corse bus
Alarm (System Alarm and Sensor Alarm)
24 VDC or
Heading receivers
Magnetic compass
Fig. 1: TMC--Converter, type 121--061 NG001
TMC--Converter
Type 121--061
2
3756.DOC010002 Edition: July 9, 2004
1.2 Technical Data
1.2.1 Mechanical Data
Dimensions, weight and protection see Dimensional Drawing 121--061.HP009
1.2.2 Electrical Data
Supply voltage: 24VDC
Power consumption: max. 10W (w/o connected receiver)
Input signal Heading signal from magnetic sonde
(R1,R2, S1, S2 und S3)
Outputs: 2x NMEA/Course bus
Alarm contacts (galvanically separated)
3x Step--signal ( 6/Step, 35VDC/max. 10W)
The outputs are protected separately:
NMEA/Course bus with 1,0A T, 250V each
Step--output with 0,25A T, 250V each
Compass
TMC--Converter
Type 121--061
3
3756.DOC010002Edition: July 9, 2004
2 Operating
There are no operating elements at the TMC--Converter type 121--061 NG001.
After switching ON of the supply voltage of 24VDC the Converter is in operation.
To configurate the outputs,see section 3.3 .
TMC--Converter
Type 121--061
4
3756.DOC010002 Edition: July 9, 2004
3 Installation of the TMC--Converter
3.1 Mounting of the TMC--Converter
The TMC--Converter should be mounted at a location where shocks and vibrations are
minimal.
The mounting should be performed in that manner, that there are no influences of
seastate.
The TMC--Converter should be installed under consideration of
Dimensional Drawing 138--118.HP005.
The frontcover should be removable after installation.
Referring to the internal protection at the dimensional drawing should be observed.
Compass
TMC--Converter
Type 121--061
5
3756.DOC010002Edition: July 9, 2004
3.2 Establishing of cable connections
3.2.1 General remarks
Caution
When establishing cable connections ensure that the
cables are disconnected from the power supply.
It is essential to ensure that all cables are disconnected
from the power supply, if necessary measure the voltage
beforehand and/or disconnect the relevant distributor.
In order to ensure that the converter operates correctly, it is essential that you follow the
procedures described below for establishing cable connections.
-- Strip approx. 180 mm of the cable.
(Depending from the distance of the cable inlet to the connection terminal)
Make sure you do not damage the shielding layer.
-- Strip off the shielding to a remainder of approximately 15mm .
approx. 180mm
approx.
15mm
Fig. 2: How to strip the connection cable
-- Screw the cable gland out from respective housing and push the screw connection
components over the cable.
It is absolutely essential that the sequence (as shown in Fig. 3) is adhered to.
-- check the cone and counterpart on the earthing insert for corrosion and if necessary
remove corrosion using an appropriate process (emery board).
-- Push the counterpart of the earthing insert as far as the end of the cable shield.
TMC--Converter
Type 121--061
6
3756.DOC010002 Edition: July 9, 2004
-- Push the earthing insert cone below the shielding against the counterpart.
Observe a shared evenly distribution of the shielding via the cone (see Fig. 3).
Shielding
Seal
+ strain relief
Washer
Cable
Counter nut
Earthing insert
-- Cone
-- Counterpart
Wall and DIN socket
Fig. 3: Making the cable entry
-- Insert the earthing insert, the seal with and the washer into the cable gland, place the
counter nut on top and and hand--tighten.
-- Strip the cable cores to a length of approx. 15 mm, twist slightly and clamp on the
cable end sleeves. Connect the cable strands in the respective housing as shown in
the respective table. Hand--tighten the terminal screws concerned.
-- Check the connection is firm by pulling lightly.
Compass
TMC--Converter
Type 121--061
7
3756.DOC010002Edition: July 9, 2004
3.2.2 General information about establishing an earth connection
In order to comply with stringent EMC requirement, please abide by the information
given below regarding cable connections.
Use the cable types specified.
It is essential to ensure that these connections have a
common reference to ship‘s eart!
Any additional components (options) must also be con-
nected to the common earth!
Fig. 4: Example for establishing an earth connection
All earth connections must be made as shown in Fig. 4 .
The earthing cable must possess a cross--section of minimum 1,5mm
2
.
The cable bracket should be mounted between two toothed discs.
Earth connections must be free of corrosion and well fastened.
TMC--Converter
Type 121--061
8
3756.DOC010002 Edition: July 9, 2004
3.2.3 Connection of the cables
1
2
3
4
5
6789
1 B2 Connection for the magnetic sonde
2 B17 Contact for “Sensor Alarm TMC”
3 B11 Contact for “System Alarm”
4 B24 Serial output NMEA/Course bus
5 B23 Serial output NMEA/Course bus
6 B7 Step output 6/Step, 35VDC
7 B8 Step output 6/Step, 35VDC
8 B9 Step output 6/Step, 35VDC
9 L1 Connection for 24VDC Supply voltage
(1--2--3)
Fig. 5: Location of plugs and terminal boards
Cable connections for each plug or terminal board is shown in below mentioned table or
in wiring diagram 121--061.HP011 .
Compass
TMC--Converter
Type 121--061
9
3756.DOC010002Edition: July 9, 2004
Plug/Termi -
nal board
Figure/
Ref.no.
Contact Connection
B2 Fig. 5/1 1 Magnetic sonde R1
Fig. 5/1 2 Magnetic sonde R2
Fig. 5/1 3 Magnetic sonde S1
Fig. 5/1 4 Magnetic sonde S2
Fig. 5/1 5 Magnetic sonde S3
Fig. 5/1 6
Magnetic sonde
B11 Fig. 5/3 1 Contact “System Alarm”
1
Fig. 5/3 2 Contact “System Alarm”
1
2
Fig. 5/3 3 Contact “System Alarm”
3
B17 Fig. 5/2 1 Contact “Sensor Alarm””
1
Fig. 5/2 2 Contact “Sensor Alarm”
1
2
Fig. 5/2 3 Contact “Sensor Alarm”
3
B24 Fig. 5/4 1 Serial output NMEA/Course bus, 24VDC
Fig. 5/4 2 Serial output NMEA/Course bus, 0V
Fig. 5/4 3
Serial output NMEA/Course bus
Fig. 5/4 4 Serial output NMEA/Course bus, TXD+
Fig. 5/4 5 Serial output NMEA/Course bus, TXD--
Fig. 5/4 6 Serial output NMEA/Course bus, GND
B23 Fig. 5/5 1 Serial output NMEA/Course bus, 24VDC
Fig. 5/5 2 Serial output NMEA/Course bus, 0V
Fig. 5/5 3
Serial output NMEA/Course bus
Fig. 5/5 4 Serial output NMEA/Course bus, TXD+
Fig. 5/5 5 Serial output NMEA/Course bus, TXD--
Fig. 5/5 6 Serial output NMEA/Course bus, GND
TMC--Converter
Type 121--061
10
3756.DOC010002 Edition: July 9, 2004
Plug/Termi -
nal board
Figure/
Ref. no.
Contact Connection
B7 Fig. 5/6 1 Step output 6/Step, 35VDC, 35VDC
Fig. 5/6 2 Step output 6/Step, 35VDC, 0V
Fig. 5/6 3 Step output 6/Step, 35VDC, S1
Fig. 5/6 4 Step output 6/Step, 35VDC, S2
Fig. 5/6 5 Step output 6/Step, 35VDC, S3
B8 Fig. 5/7 1 Step output 6/Step, 35VDC, 35VDC
Fig. 5/7 2 Step output 6/Step, 35VDC, 0V
Fig. 5/7 3 Step output 6/Step, 35VDC, S1
Fig. 5/7 4 Step output 6/Step, 35VDC, S2
Fig. 5/7 5 Step output 6/Step, 35VDC, S3
B9 Fig. 5/8 1 Step output 6/Step, 35VDC, 35VDC
Fig. 5/8 2 Step output 6/Step, 35VDC, 0V
Fig. 5/8 3 Step output 6/Step, 35VDC, S1
Fig. 5/8 4 Step output 6/Step, 35VDC, S2
Fig. 5/8 5 Step output 6/Step, 35VDC, S3
L1 Fig. 5/9 1 Supply voltage 24VDC
Fig. 5/9 2 Supply voltage 0V
Fig. 5/9 3
Compass
TMC--Converter
Type 121--061
11
3756.DOC010002Edition: July 9, 2004
3.3 Adjustments of the data formats
(see also assembly drawing with configuration 121--061.HP101)
Both serial outputs are adjustable for data format, type of telegram and telegram repeti-
tion rate. Adjustable are (for each output separately):
-- NMEA or Course bus
-- NMEA HCHDG or NMEA HCHDT
-- NMEA repetition rate 0,1 second or 1 second
Adjustments are performed by Jumper B32 (Fig. 7).
No Jumper
B32
1/2
3/4
5/6
7/8
Fig. 6: Adjustments of data formats
Jumper B32
Fig. 7: Jumper B32
After the complete installation a alignment of the magnetic sonde has to be performed
according to section 4.1.1 .
TMC--Converter
Type 121--061
12
3756.DOC010002 Edition: July 9, 2004
4 Maintenance and Repair
4.1 Maintenance
The TMC--Converter is maintenance free.
4.1.1 Alignment (sensitivity of magnetic sonde)
Basic status:
-- TMC--Converter is installed.
-- Magnetic compass is installed together with the magnetic sonde.
-- Magnetic compass is connected to the TMC--Converter.
-- Heading repeater is connected.
-- Data format is adjusted (NMEA or Course bus)
After applying the supply voltage(s) the heading repeater synchronizes at its 0--position
and turns after that to the true heading value.
If the heading display from the heading receiver is differing from the heading from the
magnetic compass, the screws of the magnetic sonde must be loosened and the ma-
gnetic sonde has to be turned within its mounting until both heading values correspond.
Alignment:
(see Fig. 8)
At headings of “North”, “East”, “South” and “West” voltages have to be measured at the
test--points TP11 and TO 12 and have to be aligned with a potentiometer to a value ac-
cording to below mentioned table.
Heading of ma-
gnetic compass
Test--point Potentiometer voltage to be
aligned
03 TP12 R155 4,3VDC 0,1VDC
1803 TP12 R155 0,7VDC 0,1VDC
903 TP11 R155 4,3VDC 0,1VDC
2703 TP11 R155 0,7VDC 0,1VDC
The potentiometer R113 is pre--aligned by the company, but if there is a higher deviation
at the 45 intermediate--values, than the heading value of the connected heading re-
ceiver has to be adapted with potentiometer R113.
Compass
TMC--Converter
Type 121--061
13
3756.DOC010002Edition: July 9, 2004
TP12
TP11
R155 R113
Fig. 8: Alignment magnetic sonde TMC--Converter
TMC--Converter
Type 121--061
14
3756.DOC010002 Edition: July 9, 2004
4.1.2 Repair
Except of a replacement of fuses for connected heading receivers no further repair
works are possible.
In case of a defect the TMC--Converter has to be replaced complete.
The TMC--Converter has to be switched OFF from any supply
voltage to replace a fuse.
Only original spare parts are allowed to be used.
1
2
3
4
5
Fig. 9: Fuses of the TMC--Converter outputs
Figure/Ref.no.
Fuse Value Output
Fig. 9/1 E2 1,0 A T, 250V Serial output at plug B24
Fig. 9/2 E1 1,0 A T, 250V Serial output at plug B23
Fig. 9/3 E11 0,25A T, 250V Step output at plug B9
Fig. 9/4 E10 0,25A T, 250V Step output at plug B8
Fig. 9/5 E9 0,25A T, 250V Step output at plug B7
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Raytheon TMC Converter, 121-061 Operating instructions

Type
Operating instructions

Raytheon TMC Converter, 121-061, is a device used for transmitting course information to repeater compasses or other nautical signal loads. It is commonly used by ships under 500 gross tons that want to install an electrical heading input for their autopilot and compass repeaters. Additionally, it can be used as an independent magnetic compass system to transmit compass information to heading repeaters.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI