97638C (Rev. H - 5/08)PAGE 1
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
Halsey Taylor Owners Manual
Non-Refrigerated Fountains
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
FIG. 1
TUBE IS
SECURED
IN POSITION
SIMPLY PUSH IN
TUBE TO ATTACH
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
FIG. 2
OPERATION OF QUICK CONNECT FITTINGS
OVL-EBP OVL-SBP OVL-SEBP OVL-ESBP
FIG. 3 FIG. 4
23
24 15
14
Regulator Mounting
Bracket
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-
TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
Installer
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
97638C (Rev. H - 5/08) PAGE 2
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
OVL - EBP/SBP/SEBP/ESBP COOLER INSTALLATION
1. Fountains using the MPW Mounting Plate refer to Fig's. 6,8,10, or 12 for hanger bracket
location and rough-in dimensions.
NOTE: Review separate installation instructions for details of the MPW Mounting Plate.
Fountains using the Wall Plate Assy. refer to Fig's. 5,7,9, or 11 for rough-in dimensions.
2. Shown dimensions pertain to installation location (framing must support up to 150 lbs. weight
for single fountain and 300 lbs. for dual fountains). These dimensions are required for compliance
with ANSI Standard A117.0.
3. Install rough-in plumbing as shown in Fig’s. 5,6,7,8,9,10,11, or 12. Waste line should extend a
minimum of 2" (51mm) thru the back panel. Run supply water inlet line thru back panel.
Install a service stop (not provided). Turn on supply water and flush thoroughly.
4. Installing back panel.
Ftn. w/MPW Mounting Plate: Refer to Fig. 16 for placement of braces onto back panel.
Place the upper edge of the panel above hanger bracket. Slide the panel down until it engages the
hanger bracket. Be sure back panel is firmly engaged before releasing it.
Ftn. w/Wall Plate Assy.: Place the upper edge of the panel above mounting plate on the
wall. Slide the panel down until it engages the hanger. Be sure back panel is firmly engaged
before releasing it.
5. Remove bottom access panel from fountain basin and save the screws.
Ftn. w/MPW Mounting Plate: Install the fountain to the back panel and wall using (4) 5/16 “ x 6”
long threaded rods, washers, and nuts (provided). Tighten securely.
Ftn. w/Wall Plate Assy.: Install the founrain to the back panel and wall using
(4) 5/16" x 3/4" long bolts and washers (provided) thru holes in back panel. Washer used on
bottom two (2) holes only. Tighten securely.
6. Cut waste tube to required length using plumbing hardware and trap (not provided) as a
guide. Install hardware and trap. Tighten securely.
7. Make water supply connections from service stop to the fountain strainer. Insert the
water inlet line into the inlet side of strainer until it reaches a positive stop - about 3/4"
(See Fig. 2). Turn on water supply and check for leaks. Newly installed water supply line
should be insulated after leak check is completed. DO NOT SOLDER TUBES INSERTED
INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
8. Check stream height from bubbler. Stream height is factory set at 45-50 PSI. If supply
pressure varies greatly from this, adjust the screw on regulator (item 14, on page 1).
Clockwise adjustment will raise stream height and counter-clockwise will lower stream
height. For best adjustment stream height should be approximately 1-1/2" (38mm) above
the bubbler guard. (See Figure 3)
9. Water Valve Mechanism - ADJUSTMENT PROCEDURE:
- Turn adjustment screw (Item 26, page 11) counter-clockwise until water flow from
bubbler starts
- Turn adjustment screw clockwise until water flow stops, then turn an additional
1/2 turn
10. Replace bottom access panel to fountain using the screws provided. Tighten securely.
97638C (Rev. H - 5/08)PAGE 3
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
FIG. 5
LEGEND:
A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided)
B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet)
C = 1/4" (6mm) DIA. Holes For Mounting Plate To Wall
FINISHED FLOOR
ROUGH-IN FOR OVL-EBP WITH WALL PLATE ASSY.
97638C (Rev. H - 5/08) PAGE 4
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
ROUGH-IN FOR OVL-EBP WITH MPW100 MOUNTING PLATE
FIG. 6
43 7/8"
1114mm
HANGER
BRACKET
"A"
"B"
BACK PANEL
"C"
MPW100
MTG. PLT.
27 1/2"
698mm
28 1/2"
724mm
1/2"
13mm
8"
203mm
16"
406mm
27"
685mm
ADA
REQUIREMENT
7"
179mm
5/8"
16mm
18"
457mm
FINISHED WALL
FINISHED FLOOR
1 7/8"
47mm
8"
203mm
MPW100 MTG. PLT.
REF. SEPARATE INSTALLATION
INSTRUCTIONS FOR DETAILS
LEGEND:
A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided)
B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet)
C = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
97638C (Rev. H - 5/08)PAGE 5
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
LEGEND:
A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided)
B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet)
C = 1/4" (6mm) DIA. Holes For Mounting Plate To Wall
FIG. 7
FINISHED FLOOR
ROUGH-IN FOR OVL-SBP WITH WALL PLATE ASSY.
97638C (Rev. H - 5/08) PAGE 6
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
ROUGH-IN FOR OVL-SBP WITH MPW100 MOUNTING PLATE
FIG. 8
43 7/8"
1114mm
33 5/8"
854mm
34 5/8"
879mm
8"
203mm
1/2"
13mm
MPW100
MTG. PLT.
HANGER BRACKET
BACK PANEL
"C"
"A"
"B"
16"
406mm
FINISHED FLOOR
33"
837mm
7"
179mm
5/8"
16mm
13 5/16"
338mm
FINISHED WALL
1 7/8"
47mm
8"
203mm
MPW100 MTG. PLT.
REF. SEPARATE INSTALLATION
INSTRUCTIONS FOR DETAILS
LEGEND:
A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided)
B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet)
C = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
97638C (Rev. H - 5/08)PAGE 7
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
FIG. 9
LEGEND:
A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided)
B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet)
C = 1/4" DIA. (6mm) Holes For Mounting Plate To Wall
FINISHED FLOOR
ROUGH-IN FOR OVL-SEBP WITH WALL PLATE ASSY.
97638C (Rev. H - 5/08) PAGE 8
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
ROUGH-IN FOR OVL-SEBP WITH MPW200 MOUNTING PLATE
FIG. 10
18"
457mm
5/8"
16mm
13 5/16"
338mm
FINISHED WALL
FINISHED FLOOR
27"
687mm
ADA
REQUIREMENT
7"
179mm
43 7/8"
1114mm
3 1/4"
82mm
16"
406mm
32"
813mm
6 5/8"
168mm
18 3/4"
476mm
1/2"
13mm
1/2"
13mm
"A"
"A"
"B"
"B"
27 1/2"
698mm
28 1/2"
724mm
33 5/8"
854mm
34 5/8"
879mm
33"
838mm
"C"
HANGER BRACKET
BACK PANEL
MPW200
MTG. PLT.
MPW200 MTG. PLT.
REF. SEPARATE INSTALLATION
INSTRUCTIONS FOR DETAILS
LEGEND:
A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided)
B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet)
C = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
97638C (Rev. H - 5/08)PAGE 9
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
FIG. 11
LEGEND:
A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided)
B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet)
C = 1/4" DIA. (6mm) Holes For Mounting Plate To Wall
FINISHED FLOOR
ROUGH-IN FOR OVL-ESBP WITH WALL PLATE ASSY.
97638C (Rev. H - 5/08) PAGE 10
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
ROUGH-IN FOR OVL-ESBP WITH MPW200 MOUNTING PLATE
FIG. 12
3 1/4"
82mm
16"
406mm
32"
813mm
27 1/2"
698mm
28 1/2"
724mm
33 5/8"
854mm
34 5/8"
879mm
1/2"
13mm
1/2"
13mm
HANGER BRACKET
"C"
"B" "B"
"A"
"A"
BACK PANEL
FINISHED FLOOR
FINISHED WALL
18"
457mm
43 7/8"
1114mm
5/8"
16mm
13 5/16"
338mm
27"
687mm
ADA
REQUIREMENT
7"
179mm
33"
840mm
6 5/8"
168mm
18 3/4"
476mm
MPW200
MTG. PLT.
MPW200 MTG. PLT.
REF. SEPARATE INSTALLATION
INSTRUCTIONS FOR DETAILS
LEGEND:
A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided)
B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet)
C = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
97638C (Rev. H - 5/08)PAGE 11
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
FIG. 14
FIG. 15
19
2
20
29
26
29
26
27
30
22 31
25Stream Height Adjustment
18
5
10
9
12
13
6
7
8
11
1See Fig. 15
21
See Fig. 4
3, 4
16
17
See Fig. 14
FIG. 13
PUSH BAR MECHANISM
REGULATOR MOUNTING MECHANISM
Installing Back Panel: When install-
ing back panel assy. (Item 34) with
MPW (Mounting Plate), attach channel
braces as shown above. Remove the
protective backing from the tape
installed on the braces. Line up the
corresponding holes in the braces and
back panel and press firmly in place.
FIG. 16
34
97638C (Rev. H - 5/08) PAGE 12
OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F
DESCRIPTION
26990C
26988C
55836C
55991C
51546C
45396C
100322740560
160270508640
45400C
101570540560
51575C
110346220550
101637451550
161637308640
45398C
45683C
45682C
100023340560
161570808550
61314C
50986C
27006C
27342C
27000C
27344C
70861C
55840C
55839C
27002C
27338C
27004C
27340C
28328C
15005C
40045C
27008C
70856C
70854C
50198C
51667C
28327C
28326C
22797C
27886C
22799C
27888C
26958C
27890C
22795C
27892C
28120C
28121C
28168C
28169C
28838C
28839C
28811C
28821C
55996C
56159C
56092C
75541C
111577243890
27089C
27090C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
NS
NS
NS
NS
NS
NS
NS
PART NO.
Bottom Cover (OVL-S)
Bottom Cover (OVL-E)
Push Arm Actuator
Push Arm Actuator - AG
Bubbler
Bubbler - AG
Bubbler Gasket
Strainer Plate
Strainer Plate - AG
Drain Gasket
Packing Ring
Drain Nut
Friction Ring
Drain Plug
Drain Plug - AG
Waste Elbow (OVL-E)
Waste Elbow (OVL-S)
Waste Tube Gasket
Slip Nut
Regulator
Regulator Holder
Basin
Basin - AG
Basin Liner
Basin Liner - AG
Screw # 10-24 x 2
Top Plate - Actuator
Bottom Plate - Actuator
Arm w/Weldnuts (OVL-E)
Carrier Arm - AG (OVL-E)
Arm w/Weldnuts (OVL-S)
Carrier Arm - AG (OVL-S)
Regulator Mounting Bracket
Nut - Retaining
Nut Hex - UNPLTD
Reaction Bracket
Screw #10-24 x .38 PHMS
Rod - Pivot
Bushing Snap
Bumper - Reg. Valve Assy
Arm - Reg. Activating
Arm - Reg. Adjustment
Back Panel (OVL-EBP)
Back Panel (OVL-EBP) (AG)
Back Panel (OVL-SBP)
Back Panel (OVL-SBP) (AG)
Back Panel (OVL-SEBP)
Back Panel (OVL-SEBP) (AG)
Back Panel (OVL-ESBP)
Back Panel (OVL-ESBP) (AG)
Wall Plate Assembly - OVL-SBP
Wall Plate Assembly - OVL-SEBP
Wall Plate Assembly - OVL-EBP
Wall Plate Assembly - OVL-ESBP
Back Panel Assy. (OVL-EBP)
Back Panel Assy. (OVL-SBP)
Back Panel Assy. (OVL-SEBP)
Back Panel Assy. (OVL-ESBP)
Strainer
Bubbler Nipple Assy
Tube - Poly (Cut To Length)
Washer-Flat .339/.359ID Steel
Screw-Mach. 5/16-18 x 3/4
Hanger Bracket (OVL-EBP/SBP)
Hanger Bracket (OVL-SEBP/ESBP)
ITEM NO.
PARTS LIST
FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
TROUBLE SHOOTING AND MAINTENANCE
Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or
not regulate. Mineral deposits may be removed from the orifice with a
small round file or small diameter wire.
CAUTION: DO NOT file or cut orifice material.
Stream Regulator: If orifice is clean, regulate flow as in
“STREAM HEIGHT ADJUSTMENT” instructions on pg 2. If replacement
is necessary, see parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings: Fountain is provided with
lead-free connectors which utilize an o-ring water seal. To remove
tubing from the fitting, relieve water pressure, push in on the gray collar
while pulling on the tubing.(see Fig.2) To insert tubing, push tube
straight into fitting until it reaches a positive stop, approximately 3/4".
CAUTION: To preserve the quality and keep this AZTEC GOLD finish clean
and spot free, clean this surface with only mild detergent or window
cleaner and polish with a soft cloth. DO NOT use any abrasive cleaners
or harsh chemicals. They WILL damage the finish!
32
SEE PUSH BAR MECHANISM
(ON PAGE 11)
SEE PUSH BAR MECHANISM
(ON PAGE 11)
SEE DETAIL
(ON PAGE 11)
SEE DETAIL
(ON PAGE 11)
32
33
33
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Halsey Taylor OVL_(EBP_SBP.C)_(ESBP_SEBP.F) (2) Owner's manual

Category
Sanitary ware
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI