Four-Faith F2164 User manual

Type
User manual
F2X64(RTU) Series
User Manual
Documentation No.
Product Version
Page
Product Name
Total:
F2X64(RTU) Series User Manual
The user manual is suitable for the following model:
Model
Product Type
F2164
GPRS RTU
F2264
CDMA RTU
Xiamen Four-Faith Communication Technology Co., Ltd.
AddJ1-J3,3rd Floor,No.44,GuanRi Road,SoftWare
Park,XiaMen,China Zip Code:361008
Tel+86 592-6300326 63003256300324
Fax:+86 592-5912735
http://www.fourfaith.com
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 2 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Files Revised Record
Date
Remark
Author
Copyright Notice
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 3 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
All contents in the files are protected by copyright law, and all copyrights are reserved by Xiamen
Four-Faith Communication Technology Co., Ltd. Without written permission, all commercial
use of the files from Four-Faith are forbidden, such as copy, distribute, reproduce the files, etc.,
but non-commercial purpose, downloaded or printed by individual (all files shall be not revised,
and the copyright and other proprietorship notice shall be reserved) are welcome.
Trademark Notice
Four-Faith信、 are all registered trademarks of Xiamen
Four-Faith Communication Technology Co., Ltd., illegal use of the name of Four-Faith,
trademarks and other marks of Four-Faith is forbidden, unless written permission is authorized in
advance.
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 4 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 5 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Contents
Contents ............................................................................................................................................ 5
Chapter 1 Brief Introduction of Product ......................................................................................... 11
1.1 General .............................................................................................................................. 11
1.2 Features and Benefits ........................................................................................................ 11
1.3 Working Principle ............................................................................................................. 12
1.4 Specifications .................................................................................................................... 14
Chapter 2 Installation Introduction ................................................................................................. 16
2.1 General .............................................................................................................................. 16
2.2 Encasement List ................................................................................................................ 16
2.3 Installation and Cable Connection .................................................................................... 16
2.4 Power ................................................................................................................................ 21
2.5 Indicator Lights Introduction ............................................................................................ 21
Chapter 3 RTU Function Introduction ......................................................................................... 22
3.1 Multiple servers funticon .................................................................................................. 22
3.2 MODBUS protocol ........................................................................................................... 22
3.2.1 MODBUS settings ................................................................................................. 22
3.2.2 TCP2COM description ........................................................................................... 23
3.2.3 MODBUS digital IO input introduction ................................................................. 23
3.2.4 MODBUS digital IO output introduction ............................................................... 24
3.2.5 MODBUS counter introduction ............................................................................. 24
3.2.6 MODBUS analog input introduction ..................................................................... 26
3.3 RTU extended protocol ..................................................................................................... 27
3.4 Alarm funtion .......................................................................................................... 28
3.5 Multiply configure parameters ................................................................................ 28
3.6 Remotely upgrade ..................................................................................................... 28
Chapter 4 Configuration .................................................................................................................. 29
4.1 RS232/RS485 Configuration ............................................................................................ 29
4.1.1 Configuration introduction ..................................................................................... 29
4.1.2 Run the configure tool ............................................................................................ 30
4.1.3 Re-power RTU ....................................................................................................... 31
4.1.4 Configuration ......................................................................................................... 32
4.1.4.1 Digital channel settings ............................................................................... 32
Digital input function ................................................................................ 32
MODBUS function ................................................................................... 33
MODBUS logic 1 corresponding function ................ 错误!未定义书签。
MODBUS logic 0 corresponding function ................ 错误!未定义书签。
Acquisition function .................................................................................. 33
Acquisition interval ................................................................................... 33
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 6 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Alarm function .......................................................................................... 33
Alarm trigger condition ............................................................................. 34
Alarm content ............................................................................................ 34
Alarm phone number ................................................................................. 34
Active report function ............................................................................... 35
4.1.4.2 Optocoupler and relay settings .................................................................... 36
Digital output function .............................................................................. 36
MODBUS logic 1 output........................................................................... 36
MODBUS logic 0 output........................................................................... 37
MODBUS logic 1 square-wave cycle ....................................................... 37
MODBUS logic 0 square-wave cycle ....................................................... 37
Default output voltage ............................................................................... 38
4.1.4.3 Analog channel settings ............................................................................... 39
Analog input function................................................................................ 39
Set sensor range ......................................................................................... 39
Set sensor voltage or current output .......................................................... 41
MODBUS function ................................................................................... 42
Acqisition function .................................................................................... 42
Acqisition interval ..................................................................................... 42
Alarm function .......................................................................................... 42
Alarm trigger condition ............................................................................. 43
Alarm content ............................................................................................ 43
Alarm phone number ................................................................................. 43
Active report function ............................................................................... 44
.4.1.4.4 RTU counterreportAlarm settings ................................................... 45
Counter function ........................................................................................ 45
Counter work mode ................................................................................... 45
Counter initial value .................................................................................. 46
Alarm function .......................................................................................... 46
Alarm content ............................................................................................ 46
Alarm phone number ................................................................................. 46
Alarm upper limit ...................................................................................... 47
Active report function ............................................................................... 47
Active report interval ................................................................................ 48
Alarm upload style .................................................................................... 48
Continuous alarm interval ......................................................................... 48
Alarm administrator number ..................................................................... 49
4.1.4.5 ModBus Setting ........................................................................................... 49
ModBus work mode .................................................................................. 50
ModBus address ........................................................................................ 50
RTU work mode ........................................................................................ 51
4.1.4.6 Data Service Center Settings ....................................................................... 52
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 7 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Data Center Number.................................................................................... 52
Main Center Addr+Port: .............................................................................. 53
Backup Center Addr+Port: .......................................................................... 53
Multi DSC Configuration ............................................................................ 54
Main and Backup Center DNS Server ........................................................ 55
Center 2~5 DNS Server ............................................................................... 55
4.1.4.7 device Settings ............................................................................................ 56
Work Mode ................................................................................................ 56
Trigger Type .............................................................................................. 57
Disconnect to Trigger mode ...................................................................... 58
Debug Level .............................................................................................. 58
Databit, Parity, Stopbit .............................................................................. 58
Communication Baudrate .......................................................................... 59
Offline detect interval ................................................................................ 59
Auto Back To Main Server ........................................................................ 59
Device ID .................................................................................................. 60
SIM Card No ............................................................................................. 60
Bytes Interval ............................................................................................ 60
Custom Register String ............................................................................. 61
Custom Heartbeat String ........................................................................... 61
Reconnect setting ...................................................................................... 61
Transfer meanning ..................................................................................... 62
4.1.4.8 Other Settings .............................................................................................. 63
Network ..................................................................................................... 63
SMS Center ............................................................................................... 64
Heartbeat Interval ...................................................................................... 64
Call Trigger Phone No............................................................................... 65
SMS Trigger Password .............................................................................. 65
Data Trigger Password .............................................................................. 65
TCP MTU .................................................................................................. 66
Multi Center Reconnect Interval ............................................................... 66
Set parameter of configure SMS ............................................................... 66
4.1.4.9 Scheduled Power ON/OFF Setting.......................................................... 67
RTC(Real Time Clock) Time Setting ........................................................ 67
Power On/Off Setting ................................................................................ 68
4.1.4.10 SMS Setting .............................................................................................. 77
Destination number ................................................................................... 77
SMS Sending Format ................................................................................ 78
Data upload Style ...................................................................................... 78
4.1.4.11 Functions ................................................................................................... 79
Show Configure ........................................................................................ 79
Show Baudrate .......................................................................................... 79
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 8 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Auto Detect ............................................................................................... 79
Version Display ......................................................................................... 79
Signal Value............................................................................................... 79
Factory setting ........................................................................................... 80
Clear Output .............................................................................................. 80
Save Output ............................................................................................... 80
Browse ...................................................................................................... 80
Save Configure .......................................................................................... 80
Load Configure ......................................................................................... 80
4.1.5 Work State Switch .................................................................................................. 81
4.2 Setting by SMS ................................................................................................................. 81
4.2.1 Setting by AT command of SMS ............................................................................ 81
4.2.2 Setting by simple command of SMS ...................................................................... 82
4.2.2.1 Format description ...................................................................................... 82
4.2.2.2 Overall setting by SMS ............................................................................... 82
Query overall command ............................................................................ 82
Query setting command ............................................................................ 83
setting remote upgrade .............................................................................. 83
4.2.2.3 Data Service Center Settings(S1 series) ...................................................... 84
Data Center Number.................................................................................. 84
Main Center Addr+Port: ............................................................................ 84
Backup Center Addr+Port: ........................................................................ 85
Multi DSC Configuration .......................................................................... 85
Main and Backup Center DNS Server ...................................................... 86
Center 2~5 DNS Server ............................................................................. 87
4.2.2.4 device Settings(S2 series) ............................................................................ 87
WorkMode ................................................................................................. 87
Trigger Type .............................................................................................. 88
Disconnect to Trigger mode ...................................................................... 88
Offline detect interval ................................................................................ 88
Debug Level .............................................................................................. 89
Device ID .................................................................................................. 89
SIM Card No ............................................................................................. 90
4.2.2.5 Other Settings(S3 series) ............................................................................. 90
Network ..................................................................................................... 90
Heartbeat Interval ...................................................................................... 91
4.2.5.6 SMS Setting(S4 series)................................................................................ 91
Set parameter of configure SMS ............................................................... 91
Destination number ................................................................................... 92
SMS Sending Format ................................................................................ 92
Data upload Style ...................................................................................... 93
4.2.5.7 Functions(S5 series) .................................................................................... 93
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 9 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Restart ....................................................................................................... 93
Factory setting ........................................................................................... 93
RTC(Real Time Clock) Time Setting ........................................................ 93
4.2.5.8 ModBus Setting(S5 series) .......................................................................... 94
ModBus work mode .................................................................................. 94
ModBus address ........................................................................................ 94
4.2.5.9 report and alarm settings(S5 series) ............................................................ 95
Active report function ............................................................................... 95
Active report interval ................................................................................ 95
Alarm upload style .................................................................................... 95
Continuous alarm interval ......................................................................... 96
Alarm administrator number ..................................................................... 96
4.2.5.10 Digital channel settings(S6 series) ............................................................ 97
Digital input function ................................................................................ 97
MODBUS function ................................................................................... 97
MODBUS logic 1 corresponding function ................ 错误!未定义书签。
MODBUS logic 0 corresponding function ................ 错误!未定义书签。
Acquisition function .................................................................................. 98
Acqisition interval ..................................................................................... 98
Alarm function .......................................................................................... 98
Alarm trigger condition ............................................................................. 99
Alarm content ............................................................................................ 99
Alarm phone number ................................................................................. 99
Active report function ............................................................................. 100
Digital output function ............................................................................ 101
MODBUS logic 1 output......................................................................... 101
MODBUS logic 0 output......................................................................... 102
MODBUS logic 1 square-wave cycle ..................................................... 102
MODBUS logic 0 square-wave cycle ..................................................... 102
Default output voltage ............................................................................. 103
4.2.5.12 Analog channel settings(S8 series) .......................................................... 103
Analog input function.............................................................................. 103
Set sensor range ....................................................................................... 104
Set sensor voltage or current output ........................................................ 105
MODBUS function ................................................................................. 106
Acqisition function .................................................................................. 106
Acqisition interval ................................................................................... 107
Alarm function ........................................................................................ 107
Alarm trigger condition ........................................................................... 108
Alarm content .......................................................................................... 108
Alarm phone number ............................................................................... 109
Active report function ............................................................................. 109
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 10 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
4.2.5.13 Counter settings(S9 series) ...................................................................... 110
Counter function ...................................................................................... 110
Counter work mode ................................................................................. 110
Counter initial value ................................................................................ 111
Alarm function ........................................................................................ 111
Alarm content .......................................................................................... 111
Alarm phone number ............................................................................... 112
Alarm upper limit .................................................................................... 112
4.3 Setting by RTU extended protocol .................................................................................. 113
Chapter 5 Software Manual .......................................................................................................... 114
5.1 TCP2COM manual.......................................................................................................... 114
5.1.1 Open software ...................................................................................................... 114
5.1.2 Install the driver ................................................................................................... 115
5.1.3 Add virtual serial port ........................................................................................... 116
5.1.4 Setting the server parameters ............................................................................... 118
5.1.5 Server connection state ........................................................................................ 119
5.1.6 Monitor................................................................................................................. 120
5.1.7 Not transmited data query .................................................................................... 121
5.1.8 Delete database data ............................................................................................. 122
5.1.9 Quit....................................................................................................................... 123
5.2 RTU center service .......................................................................................................... 123
5.2.1 Open software ...................................................................................................... 123
5.2.2 Service setting ...................................................................................................... 124
5.2.3 Start equipment and connect ................................................................................ 124
5.2.4 View the acquisition data ..................................................................................... 125
5.2.5 Send data to RS232/RS485 .................................................................................. 125
5.2.6 Control optocoupler and relay .............................................................................. 126
5.2.7 Alarm information ................................................................................................ 126
5.2.8 Center service information ................................................................................... 126
5.2.9 Query data ............................................................................................................ 127
5.2.10 Remote configure ............................................................................................... 128
5.2.11 Upgrade .............................................................................................................. 128
5.2.12 Reset device ....................................................................................................... 129
Appendix ....................................................................................................................................... 131
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 11 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Chapter 1 Brief Introduction of Product
1.1 General
F2x64 series is wireless Remote Terminal Unit(abbreviation: RTU). It has multiple functions
(analog inputdigital inputdigital outputpulse counting and wireless data communication, etc).
It adopts high-powered industrial 32 bits MCU and embedded real time operating system. It
supports RS232 and RS485 (or RS422) port that can conveniently and transparently connect
devices to a cellular network, Easy to make your existing devices connect to network just with
basic configurations. It has low power consumption work mode in which the power consumption
could be 1ower than 1mA@12VDC. It has compatible digital I/O channel, ADC, input pulse
counter and pulse wave output functions.
It has been widely used in M2M fields, such as intelligent transportation, smart grid, industrial
automation, telemetry, finance, POS, water supply, environment protection, post, weather, and so
on.
1.2 Features and Benefits
Design for Industrial Application
High-powered industrial cellular module
High-powered industrial 32 bits MCU
Support low power consumption mode, including multi-sleep and trigger modes to reduce the
power dissipation farthest
Embedded Real Time Clock(RTC) circuit which can realize timing online/offline function
Housing: iron, providing IP30 protection.
Power range: DC 5~35V
Stability and Reliability
Support hardware and software WDT
Support auto recovery mechanism, including online detection, auto redial when offline to
make it always online
RS232/RS485/RS422 port: 15KV ESD protection
SIM/UIM port: 15KV ESD protection
Power port: reverse-voltage and overvoltage protection
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 12 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Antenna port: lightning protection(optional)
Standard and Convenient
Adopt terminal block interface, convenient for industrial applications
Support standard RS232 and RS485(or RS422) port that can connect to serial devices directly
TTL logic level RS232 interface can be customized
Support intellectual mode, enter into communication state automatically when powered on
Provide management software for remote management
Support several work modes
Convenient configuration and maintenance interface
High-performance
8 analog input channelsresolution16bitInput voltage0-5V,Input current0-20mA,
Sampling rate(1.365kSPS).
4 relay outputs5A/30VDC,5A/250VAC.
4 optocoupler isolated digital outputs10mA.
8 digital inputsVoltage range3.3V-24V. one of these input ports can be configured as
pulse counter function.
2MB SPI FLASH for data log.
Support dual data centers, one main and another as backup
Support multiple data centers , it can support maximum 5 data centers
Support multi-center multi-function(for example: one data center is MODBUS RTU protocol
function, another data center is RTU extended protocol function)
Support multiple online trigger ways, including SMS, ring and data. Support link
disconnection when timeout
Support dynamic domain name(DDNS) and IP access to the data center
Support RS232/RS485 MODBUS RTU protocol.
Support TCP MODBUS RTU protocol using TCP2COM software that converts TCP to
virtual serial port.
Support 8 digital inputs and 8 analog input manual query and automatic report.
Support 4 optocoupler isolated output ports and 4 relay outputs controlled via MODBUS
RTU protocol.
Support pulse counter initiate value configurable, Its realtime value can be queried via
MODBUS RTU protocol
Support RTU extended protocol.
Acquisition data(8 analog inputs and 8 digital inputs) is reported periodically via RTU
extended RTU protocal.
Support RTU extended protocol. Reporting mode can be selected. there are three reporting
mode, including Network only, SMS only and Main network SMS backup(it uses SMS. when
network connect fail)
Support RTU extended protocol.When reporting acquisition data failure, acquisition data are
saved to 2M byte SPI FALSH.
Support RTU extended protocol. The data center can query acquisition data actively
Support RTU extended protocol. It has counter function that the initial value of the timer is
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 13 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
set and the value of the timer is queried
Support RTU extended protocol. It has the data center and RS232/RS485 transparent
transmission function.
Support RTU extended protocol. it has alarm function, alarm information is reported
automatically(alarm trigger conditions can be configured independently).
Support RTU extended protocol. Can remotely reboot RTU
Support RTU extended protocol. Can remotely configure the parameters
Support RTU extended protocol. The remote upgrading parameters can be configured, RTU
support remote upgrade firmware.
Alarm function: Alarm information are reported through RTU extended protocol , SMS, or
both SMS and RTU extended protocol
When alarm information are reported through SMS, alarm number and alarm content of each
channel can be configured independently
The remote upgrading parameters can be configured by SMS. RTU upgrade the firmware
immediately when it received the upgrade command.
Built-in industrial clock, the acquisition time can be recorded through this clock
Network is automatically connected, when device power on. Network is automatically
reconnected when network is offline.
Scheduled turn on and turn off power function make the device work in low-power mode
1.3 Working Principle
The principle chart of the RTU is as following:
Cellular
Module
MCU
Antenna
SIM/UIM
Interface
Indicator
Lights
SRAM&
FLASH
WDT Module
RTC Module
User Interface
RS232/RS485/RS422
Module
Power Module
8 digital input
ports
8 analog input
channels
4 relay
out
4 digital
output ports
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 14 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
1.4 Specifications
Cellular Specification
Standard and Band
Bandwidth
TX power
RX
sensitivity
F2164 GPRS RTU
EGSM900/GSM1800MHz,
GSM850/900/1800/1900MHz(optional)
Compliant to GSM phase 2/2+
GPRS class 10, class 12(optional)
85.6Kbps
GSM850/900
<33dBm
GSM1800/1900
<30dBm
<-107
dBm
F2264 CDMA RTU
CDMA2000 1xRTT 800MHz
800/1900MHz(optional)
450MHz(optional)
153.6Kbps
<30dBm
<-104
dBm
Hardware System
Item
Content
MCU
Industrial 32 bits CPU
FLASH
2MBExtendable 8MB
SRAM
512KBExtendable 1MB
Interface Type
Item
Content
Serial
1 RS232 port and 1 RS485port, 15KV ESD protection
Data bits: 5, 6 ,7, 8
Stop bits: 1, 1.5, 2
Parity: none, even, odd, space, mark
Baud rate: 110~230400 bps
Indicator
"Power", "ACT", "Online"
Antenna
Cellular: Standard SMA female interface, 50 ohm
GPS: Standard SMA female interface, 50 ohm
lighting protection(optional)
SIM/UIM
Standard 3V/1.8V user card interface, 15KV ESD protection
Power
Terminal block interface, reverse-voltage and overvoltage
protection
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 15 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Power Input
Item
Content
Standard Power
DC 12V/0.5A
Power Range
DC 5~35V
Power Consumption
Working States
Power Consumption
Communication
60mA@12VDC118mA@5VDC
Standby
39mA@12VDC73mA@5VDC
Timing Power
Off
1.1mA@12VDC1.1mA@5VDC
Physical Characteristics
Item
Content
Housing
Iron, providing IP30 protection
Dimensions
157x97x25 mm
Weight
500g
Environmental Limits
Item
Content
Operating
Temperature
-25~+65ºC -13~+149℉)
Extended
Operating
Temperature
-30~+75ºC -22~+167℉)
Storage
Temperature
-40~+85ºC-40~+185℉)
Operating
Humidity
95% ( Non-condensing)
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 16 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Chapter 2 Installation Introduction
2.1 General
The RTU must be installed correctly to make it work properly.
Warning: Forbidden to install the RTU when powered on!
2.2 Encasement List
Name
Quantity
Remark
RTU host
1
Cellular Antenna
1
Power adapter
1
RS232 data cable
1
optional
Terminal Block
1
5 pin
1
7 pin
1
8 pin
2
9 pin
RS485 data cable
1
optional
Manual CD
1
Certification card
1
Maintenance card
1
Table 2-1 Encasement List
2.3 Installation and Cable Connection
Dimension: (unit: mm)
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 17 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Figure 2-1 Installation Chart
Installation of SIM/UIM card:
Firstly power off the RTU, and press the out button of the SIM/UIM card outlet with a needle
object. Then the SIM/UIM card sheath will flick out at once. Put SIM/UIM card into the card
sheath (Pay attention to put the side which has metal point outside), and insert card sheath back to
the SIM/UIM card outlet.
Warning: Forbidden to install SIM/UIM card when powered on!
Installation of antenna:
Screw the SMA male pin of the antenna to the female SMA outlet of the RTU tightly.
Warning: The antenna must be screwed tightly, or the signal quality of antenna will be influenced!
User Interface Signal Definition
Pin
Number
Function
Interface
Default function
Function expansion
1
Power
PWR
Power input positive
None
2
GND
Power input negative
None
3
RS232
G/232
RS232 GND
None
4
RXD
RS232 Data receiving
None
5
TXD
RS232 Date sending
None
6
RS485
A
RS485 positive
Reserved for compatible
RS232 DTR
7
B
RS485 negative
Reserved for compatible
RS232 DSR
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 18 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
8
Digital
Input
DI1/C
Digital input1
Counting function
9
DI2
Digital input 2
None
10
DI3
Digital input 3
None
11
DI4
Digital input 4
None
12
DI5
Digital input 5
None
13
Digital
Input
DI6
Digital input 6
None
14
DI7
Digital input 7
None
15
DI8
Digital input 8
None
16
DIG
Digital input GND
None
18
Optocoupl
er output
DO1
Optocoupler output1
None
19
DO2
Optocoupler output 2
None
20
DO3
Optocoupler output 3
None
21
DO4
Optocoupler output 4
None
22
COM
COM GND
None
23
Relay
output
K1-
Relay output 1-
None
24
K1+
Relay output 1+
None
25
K2-
Relay output 2-
None
26
K2+
Relay output 2+
None
27
K3-
Relay output 3-
None
28
K3+
Relay output 3+
None
29
K4-
Relay output 4-
None
30
K4+
Relay output 4+
None
31
ADC
A1
ADC1
None
32
A2
ADC 2
None
33
A3
ADC 3
None
34
A4
ADC 4
None
35
A5
ADC 5
None
36
A6
ADC 6
None
37
A7
ADC 7
None
38
A8
ADC 8
None
39
AG
AGND
None
Installation of cable:
F2X64 adopts industrial terminal block interface. The recommendatory cable is 28-16AWG.
The detail description of standard layout adapter and communication cables as following:
AdapterRating Output 12VDC/0.5A):
Cable Color
Power Output Polarity
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 19 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Black &White Alternate
Anode
Black
Cathode
RS232 Cable
Cable Color
Corresponding DB9-M Pin Number
Brown
Pin 2
Blue
Pin 3
Black
Pin 5
RS485 Cable
Cable Color
Signal definition
Red
RS485(A)
Black
RS485(B)
Power adapter and communication cable connection chart as following:
Digital Input cable connection
F2X64(RTU) Series User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd. Page 20 of 133
Add J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http//www.fourfaith.com Tel +86 592-6300326 6300325 6300324 Fax+86 592-5912735
Optocoupler output cable connection
Relay output cable connection
ADC cable connection
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133

Four-Faith F2164 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI