JUNG 32SD Operating instructions

Type
Operating instructions

This manual is also suitable for

Blinds Management Sensor
Ref.-no.: 32 SD, 32 G, 32 K
Operating Instructions
Sun/Twilight Sensor
Glass Breakage Sensor
Adapter
1. Function
Together with the components of the Jalousie Management system,
these sensors facilitate the sun protection, twilight and glass breakage
functions.
These functions depend upon the attachment used (please refer to the
operating instructions of the attachment) and are not possible for
attachments without sensor connection.
Only one sensor plug can be connected to the attachment. If the sun
protection/ twilight sensor and the glass breakage sensor are to be
employed at the same time, please use an adapter.
The sensor or adapter can be connected to the the attachment through a
plug.
For buried installation, the sensor line can be connected to the insert
through a screw terminal (please refer to the Jalousie Management motor
control insert Operating Instructions).
2. Installation
Important: The sensor line carries protective low voltage (SELV).
Please observe the installation procedures as specified by VDE
0100.
To connect the sensors, please refer to the attachment and insert
operating instructions.
3. Sun/Twilight Sensor
The sun/twilight sensor (Fig. c) can be attached to the window pane by
its suction cup.
The sun protection function facilitates automatic shutting of the louver
after a programmed brightness value is exceeded. The end position of
the louver can be individually chosen by correspondingly positioning the
sensor on the window pane.
Applications: Sun protection at terminal workstations, sun protection for
flower windows or greenhouses etc.
Stand: Aug-08 325 181 03
Blinds Management Sensor
Ref.-no.: 32 SD, 32 G, 32 K
The twilight function facilitates automatic shutting of the louver after a
programmed brightness value is undercut. The louver moves into its
lower end position. The position of the twilight sensor can be individually
chosen on the window pane.
Application: Shutting the louver at nightfall.
Fig. 1
4. Glass Breakage Sensor
The glass breakage sensor (Fig. 2) monitors plane glass surfaces within
a maximum radius of 2 m (depending upon the pane thickness, frame,
puttying etc.) Mechanical vibrations which do not reach the sensor with
the corresponding intensity are not detected (e. g. gaps in the pane).
Window panes with uneven surfaces (structural glass, wire reinforced
glass) or multilayer glass panes produce excessively high reduction of
vibration and must not be monitored by the glass breakage sensor. The
glass must not be covered with film or foil and must not show any cracks.
The glass breakage sensor is a sensitive device.
Knocking or other improper handling may result in damage.
The glass breakage sensor must be attached to the window pane by a
suitable bonding agent (e. g. Loctite glass-metal adhesive set) (clean or
degrease the bonding surfaces of the sensor and the pane). Please
observe the information of the adhesive manufacturer. Foreign bodies
between the sensor and the window pane adversely affect sensitivity.
Please keep the distances from the window frame (please refer to Fig.
3). If the window pane is damaged, the louver will be moved into its
lower end position.
Application: Protection against weather influences in case of glass
breakage.
Fig. 2
Fig. 3
2
Blinds Management Sensor
Ref.-no.: 32 SD, 32 G, 32 K
5. Adapter
The adapter (Fig. f) can be connected to the attachment with sensor
connection or insert through the 3-pole connection terminal. The adapter
has two sockets for the connection of the sun/twilight sensor and the
glass breakage sensor.
For connecting, please refer to the ‘Insert’ Operating Instructions.
Fig. 4
6. Specifications
Sun/Twilight Sensor
Max. photodiode
sensitivity : At λ of approx. 850 nm
Max. number used : 1 piece
Temperature range : -30 °C to +70 °C
Protective system : IP 54
Glass Breakage Sensor
Contact : Single-pole normally closed
Max. switching capacity : 350 mW
Transition resistance
At rest : Max. 30 Ohms
Alarm condition : Min. 1 MOhm
Alarm duration : Approx. 0.5-5 sec
Connecting leads : LIYY 2x0.14 mm
Temperature range : -30 °C to +70 °C
Protective system : IP 67
Max. number used : 10 pcs. (to be connected in series)
Adapter
Max. number of sensors
at plug connector : 1 sun/twilight sensor
1 glass breakage sensor
3
Blinds Management Sensor
Ref.-no.: 32 SD, 32 G, 32 K
7. Guarantee
Our products are under guarantee within the scope of the statutory
provisions.
Please return the unit postage paid to our central service
department giving a brief description of the fault:
ALBRECHT JUNG GMBH & CO. KG
Service-Center
Kupferstr. 17-19
D-44532 Lünen
Service-Line: +(49) 23 55 . 80 65 51
Telefax: +(49) 23 55 . 80 61 65
General equipment
Service-Line: +(49) 23 55 . 80 65 55
Telefax: +(49) 23 55 . 80 62 55
KNX equipment
Service-Line: +(49) 23 55 . 80 65 56
Telefax: +(49) 23 55 . 80 62 55
The CE-Sign is a free trade sign addressed exclusively to the
authorities and does not include any warranty of any properties.