1 Regulatory Information ............................................................................................................... 3
Indications for Use ........................................................................................................................... 3
Warnings and Precautions ............................................................................................................... 4
Compliance with Applicable Standards ............................................................................................ 6
Typical X-ray Scatter Dose Rates .................................................................................................... 7
Certified Components ...................................................................................................................... 9
Device Labeling .............................................................................................................................. 10
Optional Cephalometric Extension Labeling .................................................................................. 11
EC Declaration of Conformity ........................................................................................................ 12
EMC Statement .............................................................................................................................. 13
Authorized Representatives ........................................................................................................... 16
2 Introduction ............................................................................................................................. 17
Product Description ........................................................................................................................ 17
Disclaimer about the Manual ......................................................................................................... 17
Symbols and Conventions ............................................................................................................. 18
Obtaining Technical Support .......................................................................................................... 19
3 System Overview ..................................................................................................................... 20
About the Vantage System ............................................................................................................ 20
About the Panoramic X-ray Device ................................................................................................ 20
About the Optional Cephalometric Extension ................................................................................ 22
4 Pre-Installation Planning .......................................................................................................... 26
Environmental Requirements ......................................................................................................... 26
Support Requirements ................................................................................................................... 27
Power and Cable Requirements .................................................................................................... 27
Space Requirements ...................................................................................................................... 28
Network and System Requirements .............................................................................................. 30
5 Installation ............................................................................................................................... 31
About Installation ............................................................................................................................ 31
Optional Right Entry Configuration ................................................................................................ 31
Installing the Vantage Panoramic Device on a Wood Stud Wall ................................................... 32
Installing the Vantage Panoramic Device on a Free-Standing Base ............................................. 41
6 Installing the Cables................................................................................................................. 48
Connecting the Vantage to your network ....................................................................................... 48
Installing the Exposure Button ....................................................................................................... 49
Installing a Generic Two-Wire Remote Exposure Switch .............................................................. 52
7 Starting Up ............................................................................................................................... 54
Turning the Vantage System On .................................................................................................... 54
Checking Image Quality ................................................................................................................. 55
8 Vantage Software Client Setup ................................................................................................ 57
About .............................................................................................................................................. 57
Installation Procedure .................................................................................................................... 57
Connecting to Vantage................................................................................................................... 61
9 Installing the Cephalometric Extension .................................................................................... 64
10 Midmark Imaging Support Information ..................................................................................... 99
Progeny
Vantage Panoramic
X
ray System Installation
Guide
1 Regulatory Information
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Do not stare into the beam. Do not place eyes closer than 100 mm. This equipment
contains class 2 lasers of 3 mW output at 650 nm. The beam is a 40° fan line. The
lensing on the laser is not removable. Laser on time does not exceed 100 seconds.
Use of procedures other than those contained within this manual may result in
exposure to damaging laser light
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Progeny
Vantage Panoramic
X
ray System Installation
Guide
A Rad-Cal model
160cc ion-chamber (µRem) meter was used to integrate the doses. M
0.005 mR
0.036
µR
0.012 mR
0
.035 mR
1 m
0.040 mR
0.039 mR
0.027 mR
0.003 mR
Front of the X-ray system
0.00 mR
0.00
mR
0.012 mR
0.003 mR
2 m
0.017 mR
0.008 mR
0.003 mR
0.008 mR
Front of the X-ray system
Progeny
Vantage Panoramic
X
ray System Installation
Guide
0.035 mR
0.0
37 mR
0
.
0
44
mR
0.175 mR
2 m
X
-
r
a
y
s
o
u
r
c
e
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Progeny
Vantage Panoramic
X
ray System Installation
Guide
imagingtechsupport@midmark.com
The Progeny Vantage Panoramic Dental X-ray System is considered as non-life-supporting equipment.
While using the Progeny Vantage X-ray System adjacent to other equipment, the configuration should be
carefully adjusted to ensure that electromagnetic interference (EMI) does not degrade performance.
Specifically, mobile RF communications equipment can effect medical electrical equipment. Please refer
to the EMC table below.
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Group
1
Class B
Class A
Complies
Not Applicable.
Not
Applicable.
Progeny
Vantage Panoramic
X
ray System Installation
Guide
3
V
𝑑
=
1
.
2
×
𝑃
3
V/m
𝑑
=
1
.
2
×
𝑃
𝑑
=
2
.
3
×
𝑃
P
d
V
𝑑
=
1
.
2
×
𝑃
𝑑
=
1
.
2
×
𝑃
𝑑
=
2
.
3
×
𝑃
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Progeny
Vantage Panoramic
X
ray System Installation
Guide
2 Introduction
Product Description
Disclaimer about the Manual
Symbols and Conventions
Obtaining Technical Support
The Progeny Vantage Panoramic X-ray System is an easy to use and easy to
install digital panoramic X-ray system.
The panoramic X-ray provides a broad overview of the teeth, jaw, and oral
structure of the entire mouth. The X-ray image supplies information about the
teeth, upper and lower jawbone, sinuses, and other hard and soft tissues of the
head and neck. The panoramic digital receptor is contained in a C-arm that
moves around the patient’s head.
The Vantage System has many applications that include evaluation of third
molars, evaluation of patients with past and present TMJ (temporomandibular
joint) problems, patients who require full or partial removable dentures, dental
implants, or braces, those who are at risk or suspected of having oral cancer or
other tumors of the jaw, those who have impacted teeth, and those who have
had any recent trauma to the face or teeth (i.e., can help identify a fractured jaw).
The optional Cephalometric Extension allows for lateral and PA views of oral
structures. The ceph digital receptor is mounted on a transit rail which scans
horizontally during ceph examinations. Cephalometric images are typically
useful in orthodontic evaluation and treatment.
Midmark pursues a policy of continual product development. Although every
effort is made to produce up-to-date product documentation, this publication
should not be regarded as an infallible guide to current specifications. We
reserve the right to make changes without prior notice. The original language of
this manual is English.
Progeny
Vantage Panoramic
X
ray System Installation
Guide
Symbol
Explanation
Type B: Protection against electric shock (IEC 60601.1-
1988).
Consult written instructions in the User Guide.
ATTENTION RAYONS-X:
OPERATION SEULEMENT PAR DU PERSONNEL
AUTORISE. VOIR MANUEL DE L’OPERATEUR.
WARNING X-RAY
THIS X-RAY UNIT MAY BE DANGEROUS TO
PATIENT AND OPERATOR UNLESS SAFE
EXPOSURE FACTORS AND OPERATING
INSTRUCTIONS ARE OBSERVED.
X-RAY EMISSION
Mains HOT WIRE
Mains NEUTRAL WIRE
Earth Ground
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT. 650 nm, 3 mW
Power off (circle)
Power on (line)
Waste Electrical and Electronic Equipment (WEEE). WEEE
distributed in the European Economic Area (EEA) must be
collected and disposed of separately from other waste, per
WEEE Directive 2012/19/EU. Contact your equipment dealer
for in
formation on local compliance schemes.
Progeny
Vantage Panoramic
X
ray System Installation
Guide
For Technical Support, contact:
MIDMARK CORPORATION
1001 Asbury Drive
Buffalo Grove, Illinois 60089 U.S.A.
Phone: 888-924-3800 (U.S. and Canada)
+1 847-415-9800 (International)
Fax: 847-415-9801
imagingtechsupport@midmark.com
Hours: 8:00 a.m. – 5:00 p.m. CT
Progeny
Vantage Panoramic
X
ray System Installation
Guide
3 System Overview
About the Vantage System
About the Panoramic X-ray Device
About the Optional Cephalometric Extension
The Progeny Vantage Panoramic X-ray System consists of the panoramic X-ray
device, the exposure button, and a Touch Control Panel.
The panoramic X-ray device consists of the telescoping column, the overhead
assembly, the patient positioning table, and the touch control panel.
The telescoping column has two main parts: the fixed section and the moving or
telescoping section. The fixed section contains the actuator to control up and
down movement of the panoramic X-ray device. The telescoping section mounts
the patient positioning features. Optical sensors in the telescoping section define
the maximum and minimum extension of the column.
The overhead assembly consists of an overhead arm and C-arm. The overhead
arm supports the C-arm, which rotates. The C-arm includes the tubehead and
the removable sensor. The tubehead produces the X-ray beam, and the sensor
is a digital image receptor.
The patient positioning table guides and supports the patient’s head during
acquisition of panoramic X-ray images by means of the chin rest, bite guide, and
positioning wands. The positioning control on the side of the patient positioning
table has 4 buttons for the operator to control the up/down movement of the
telescoping column, to apply and release the positioning wands, and to turn on
positioning lights. The patient positioning table also contains a storage
compartment.
The touch control panel is mounted on the fixed column section under the patient
positioning table. It is the main user interface for taking X-ray images with the
Vantage System and is activated by touch.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Midmark Vantage Panoramic X-ray System Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI