Eagle AVI Installation & Owner's Manual

Category
Gate Opener
Type
Installation & Owner's Manual
Installation & Owners Manual
Slide Gate Operator
AV I
AVI
TM
ACCESS CONTROL SYSTEMS, INC.
Made in the USA
P
OW
ER
E
D BY
EAGL
E
AV I
Maximum Gate Capacity 14 ft & 200 lbs
AVI Slide Rev - C
2
AVI Slide Rev - C
1
AVI Slide Rev - C
UL 325 Class I, II, III and IV
Motor Power 1/2 HP - 120 VAC @ 60 Hz - 4.3 amp
Chain Type #41
Max Gate Length 14 ft
Max Gate Weight 200 lbs
Normal Gate Cycles Continuous
Entrapment Protection:
Built-In ERD adjustable reversing sensor
Input for photo sensor
Input for edge sensor
TABLE OF CONTENTS
© 2017 Eagle Access Control Systems, Inc.
All rights reserved. No part of this manual may be reproduced in any means: graphics, electronics or mechanical. Including photocopying
without the expressed written permission of the publisher. Materials components and specifications are subject to change without notice.
SAFETY
UL 325 Listings
UL 325 Model Classifications
UL 325 Required Entrapment Protection
Important Safety Information
General Safety Information
2
3
3
4
4-6
2
METHODS OF INSTALLATION
Front Position
Rear Position
Gate Connection
Concrete Pad Installation
Post Mount Installation
Reverse and Exit In-Ground Loop Installation
External Entrapment Protection
7
8
8
9
9
10
10
7
CONTROL BOARD ADJUSTMENTS AND WIRING
Feature Selector Switches #1 - #4
Control Board Overview
120 VAC Input Power Connection
Setting the: Limit Nuts & Open Left or Open Right
Power Fail Operation
Radio Receiver Installation and “Learning” Remote Button
Close Timer for a Single or Master Operator
Two-Way Adjustable Reverse Sensor / ERD
Input/Output Connection Descriptions
Connecting Accessories
Master / Slave Setup
Troubleshooting
AVI Wiring Diagram
AVI Replacement Parts
11
11
12
12
13
13
14
14
15
16
17
18
18
19-20
11
AVI SLIDE GATE OPERATOR SPECIFICATIONS
13.5”
15.3/8”
8”
12.5”
POWERED BY EAGLE
AV I
Chain
Height
3”
2
AVI Slide Rev - C
SAFETY
1. Install the gate operator only when:
a) The operator is appropriate for the construction of the gate and the usage class of the gate.
b) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.83 m) above the
ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion
of the adjacent fence that the gate covers in the open position.
c) All exposed pinch points are eliminated or guarded, and
d) Guarding is supplied for exposed rollers.
2. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The
pedestrian access opening shall be designed to promote pedestrian usage. Locate the pedestrian gate such that persons will not come in
contact with the vehicular gate during the entire path of travel of the vehicular gate.
3. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and
closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
4. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the
operator clutch or pressure relief valve to compensate for a damaged gate.
5. For gate operators utilizing Type D protection:
a) The gate operator controls must be placed so that the user has full view of the gate area when the gate is not moving.
b) The placard provided marked in letters at least 1/4 in. (6.4-mm) high with the word “WARNING” and the following statement or the
equivalent: “Moving Gate Has the Potential of Inflicting Injury or Death – Do Not Start Gate Unless Path is Clear” shall be placed adjacent
to the controls,
c) An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and
d) No other activation device shall be connected.
6. Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is
prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a
security feature to prevent unauthorized use.
7. The Stop and /or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to
start.
8. A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
9. For gate operators utilizing a non-contact sensor in accordance with Usage Class:
a) See instructions on the placement of non-contact sensors for each type of application,
b) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving,
and
c) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable
by a moving gate or barrier.
10. For gate operators utilizing a contact sensor in accordance with Usage Class:
a) One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing
edge, and post-mounted both inside and outside of a vehicular horizontal slide gate.
b) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
c) One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
d) A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate
operator is not subjected to mechanical damage.
e) A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection
functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural
landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
f) One or more contact sensors shall be located on the inside and outside leading edge of a swing gate.
Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one
or more contact sensors shall be located on the bottom edge.
g) One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
UL 325 Listings
UL 325 Listings
3
AVI Slide Rev - C
UL 325 Model Classifications
UL 325 Entrapment Protection
CLASS I
Residential Vehicular Gate Operator - A vehicular gate
operator (opener or system) intended for use in a home
of one to four single family dwellings, or a garage or
parking area associated therewith.
CLASS II
Commercial/General Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for
use in a commercial location or building such as a
multi-family housing unit (five or more single family
units) hotel, garages, retail store or other building
servicing the general public.
CLASS III
Industrial/Limited Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for
use in a industrial location, loading dock area or other
location not intended to service the general public.
CLASS IV
Restricted Access Vehicular Gate Operator - A vehicular
gate operator (opener or system) intended for use in a
guarded industrial location or buildings such as airport
security area or other restricted access locations not
servicing the general public, in which unauthorized
access is prevented via supervision by security
personnel.
Entrapment Protection Requirements for Each Type of Operator.
Proper installation must satisfy the entrapment protection chart as shown.
A - Inherent (built into the gate operator) entrapment
protection.
B1 - Non-contact sensor such as photo-eye or equivalent.
B2 - Contact sensor such as edge sensor or equivalent.
C - Inherent adjustable clutch or pressure relief device.
D - Actuating device requiring continuous pressure to
maintain gate motion.
CLASS I
CLASS II
CLASS III
CLASS IV
* UL 325 requires that B1 and B2 means of entrapment protection must be MONITORED.
A, B1*, B2* or D
A, B1*, B2* C or D
Gate Type
Horizontal Slide
Vertical Lift
Vertical Pivot Gate
Swing Gate or
Vertical Barrier (arm)
Entrapment Protection
UL 325 Classifi cations
4
AVI Slide Rev - C
General Safety
Important Safety Information
General Safety Information
Install Warning Signs
Installing Opening Devices
1. Never let children operate or play with gate controls. Keep the remote control away from children.
2. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
3. Test the operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact
sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can
increase the risk of injury or death.
4. Use the emergency release ONLY when the gate is not moving and verify that operator power has been turned OFF.
5. KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware.
6. The entrance is for vehicles only. Pedestrians must use separate entrance.
7. BE SURE TO CONTINUE TO KNOW AND PRACTICE THESE INSTRUCTIONS. SAVE THESE INSTRUCTIONS
To reduce the risk of injury or death read and follow the instructions
WARNING
Be sure to read and follow all the Eagle Access Control Systems, Inc. before installing and operating any Eagle
Access Control System, Inc. products. Eagle Access Control Systems, Inc. is not responsible for any improper
installation procedures caused by failure to comply with local building codes.
Install warning signs on BOTH sides of the gate.
Be sure to mount gate operating
devices at least six feet (6’) away from
any moving part of the gate. They
must NOT be able to be operated
reaching through the closed gate.
CAUTION
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Closing Gate
5
AVI Slide Rev - C
General Safety Information Continued
Entrapment Protection
Vehicular Use ONLY
Vehicular Use ONLY
DO NOT let pedestrians cross the path of
a moving gate.
Eagle gate operators are for vehicular use
only. They are NOT for pedestrian use.
Pedestrian MUST use a separate entrance.
DO NOT allow anyone to hang or ride on
the gate.
Eagle gate operators are for vehicular use
only. They are NOT for pedestrian use.
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Closing Gate
Closing Gate
Mo
v
i
ng Ga
t
e Ca
n
Cause
S
eri
ous
I
nj
ury or D
eat
h
K
E
E
P
CL
E
A
R!
Gate
m
a
y
m
o
v
e
a
t a
n
y
t
i
m
e
wi
th
o
u
t p
ri
o
r
wa
r
n
i
n
g
.
Do
n
o
t
l
e
t
ch
i
l
d
re
n
o
p
e
ra
te
th
e
g
a
te
o
r pl
a
y
i
n
t
h
e
g
a
te
a
r
e
a
.
T
h
i
s
e
n
t
r
a
n
c
e
i
s
fo
r
v
e
h
i
c
l
e
s
on
l
y.
P
e
d
e
s
t
r
i
a
n
s
m
u
s
t
u
s
e
s
e
p
a
r
a
te
e
n
t
ra
n
c
e
.
Entrapment Danger
Entrapment Danger
Safety
Loop
Optional
Exit Loop
Safety
Loop
Separat
e
Pedestrian
Entrance
In-Ground Loops: Help
protect the gate operator
from accidentally opening
and/or closing on vehicles
in the gate’s path
Opening Direction Edge Sensor:
Helps guard against the opening
gate from entrapment.
Warning Signs:
Mounted on BOTH
sides of gate.
Closing Direction Edge Sensor:
Helps guard against the closing
gate from entrapment.
Non-Contact Sensor:
Can protect the areas
of entrapment.
Physical Stops:
Install on both ends of
gate to prevent the gate
from derailing during
gate cycling.
Opening Direction Edge Sensor:
Helps guard against the opening
gate from entrapment between
wall and gate.
Physical
Stop
P
O
W
E
R
E
D
B
Y
E
A
G
L
E
AV I
See page 16 for more information.
General Safety
6
AVI Slide Rev - C
General Safety Information Continued
Closing Gate
Incorrect Correct
Obstructing
Wall
Catch Rollers
(Safety Cover)
Catch Post
Minimum of 3" Clearance between gate and
obstructing wall or other object in OPEN Position.
3"
4"
DO NOT install a stop or catch post in front of the gates path. To do so will cause the gate to hit the post in certain instances. Install catch rollers on the side of
a post or wall. When gate is fully OPEN, the end of the gate MUST stop at least three inches from a obstructing wall or object. The CLOSED gate should overlap
at least four inches from the wall or fence. Positive stops MUST be installed. Install screen or mesh on gate if necessary (see below).
Gate in Fully OPEN Position
Gate in
Fully
CLOSED
Position
Minimum of 4" gate overlap from
wall or fence in CLOSED Position.
Wall or Fence
Closing Gate
POSITIVE STOPS MUST be installed on EACH end
of the gate so the gate does NOT exceed the limit
of the rail and derail while OPENING or CLOSING.
Gate in
Fully
CLOSED
Position
6 ft min above ground
Ornamental Grill Styled Gates: Injuries may be avoided if a mesh screen is
installed on the gate. Injuries resulting from hands and feet becoming stuck in
the gate or children riding on the gate while gate is moving can be greatly
reduced if this “screen” or “mesh” is applied to the gate as a safety precaution.
Guide Rollers
Gate Stopping Positions
Positive Stops Screen or Mesh
General Safety
7
AVI Slide Rev - C
FRONT Installation
METHODS OF INSTALLATION
FRONT Position
An experienced installer should perform the installation. Improper installation may result in property damage, severe injury or death.
Read the entire manual before proceeding with the installation.
Eagle Access Control Systems, Inc. is not responsible for researching and complying with local building codes. Be sure to check all local
building codes before installation.
NOTE: FRONT installation can be mounted on a
concrete pad or post mount, see page 9.
Standard method of installation.
POWERED BY EAGLE
AV I
Top View
COMMON MISTAKES
TO BE AWARE OF:
Proper FRONT Chain Position
Operator and
chain are NOT
parallel to gate.
Chain bracket
does NOT
align with
idler wheels.
Chain brackets
positioned
too low.
Chain
brackets
positioned
too high.
Operator and chain
MUST be parallel to gate!
Chain bracket MUST align
with idler wheels!
4.5”
8” Min
8”
Correct
Chain
Bracket
Height
Chain brackets MUST be
mounted so the chain
remains the same height
as it is on the idler wheels!
NOTE: Make sure safety guidelines are
followed on pages 4-6 for installation.
POWERED BY EAGLE
AV I
NO
NO
NO
NO
NO
NO
Idler Wheels
Chain
Bracket
Gate
Gate
8
AVI Slide Rev - C
Additional Idler Wheel/Sprocket required.
Eagle part number: E651 Idler Wheel
Assembly Complete (No mounting post).
The “NO Weld Chain Kit”
comes with the gate operator.
Gate Connection
REAR Position
Conceals chain from outside of property.
Top View
2” Gate
Frame
Master Chain Link
Additional chain required.
Eagle part number: XM200 - 10 ft #41 Chain.
See previous page for “COMMON MISTAKES TO BE AWARE OF”
Proper REAR Chain Position
8”
3”
4.5”
8” Min
Idler
Wheel/Sprocket
Operator and chain
MUST be parallel to gate!
Chain bracket MUST align with
idler wheels and sprocket!
Chain brackets MUST be
mounted so the chain
remains the same height
as it is on the idler
wheels and sprocket!
Sprocket
Idler Wheel
NOTE: REAR installation can be mounted on a
concrete pad or post mount, see next page.
NOTE: Make sure safety guidelines are
followed on pages 4-6 for installation.
Idler Wheel/Sprocket
POWERED BY EAGLE
AV I
REAR Installation
Gate
Connection
9
AVI Slide Rev - C
Concrete Pad or Mount Post Installation
Concrete Pad Installation
Post Mount Installation
POW
E
RE
D
B
Y
E
A
GL
E
AV I
Run any 1/2”
conduit
needed for the
installation.
Recommended dimensions
5” min above ground.
19”
24”
18”
pipe d
epth
in concrete
recommended.
18” Min
Above
Grou
nd
24”
Below ground depth of the
concrete pad is determined
by soil conditions and local
building codes (reinforced
concrete recommended).
Drill holes in 2” ID pipes
that match holes on
plate’s pipes and secure
with bolts.
1/2”
Conduit
Holes
P
OW
E
RE
D
BY
E
A
GL
E
AV I
Bolt
2” Inside Dia. Pipe
Not provided
1/2” x 3 1/2”
Sleeve anchors
(Not provided)
Eagle Post Mount Sold Separately
Eagle Part Number: EG099
10
AVI Slide Rev - C
Loops
Entrapment Protection
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
INPUT/OUTPUT
Reverse and Exit In-Ground Loop Installation
External Entrapment Protection
Reversing loops are used to prevent the gate from closing on a vehicle while it is in the gates path.
A exit loop is used to automatically open the gate when a vehicle approaches to exit.
A phantom loop is NOT used for slide gates.
An experienced installer should perform this installation.
Installation of a reversing edge(s) or photocells for the OPENING direction of the gate is recommended.
Mount reversing edge(s) where needed (end of gate along entire height of gate and/or next to opening on operator side).
Mount photocells for entrapment protection during the OPENING cycle of gate if needed as shown below (they are typically mounted 21”
above the ground but no higher that 27.5” high).
Multiple external entrapment devices may be connected in parallel to #4 M-FCN Input. Multi-Function switches 1 and 2 MUST be set to OFF.
Loop wire must be wrapped inside
the groove three times. Fill the
grooves with a proper sealant.
External Loop Detector
Connect loop wires directly to external loop detector.
See page 16 to wire loop detectors to control board.
Loop feed must have the loop
wires twisted in them approx.
6 twists per foot.
Groove
4’
4’
4’
4’4’
Reverse Loop
Cutaway of Groove Loop Feed
Loop
Feed
4’ Min.
4’
4’4’
Reverse Loop
Exit Loop
1 1/2”
1/4”
Backer Rod
Sealant
Twisted
Loop Wire
Inside
PVC Conduit
Separate
Power
MULTI FUNCTION
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
M-FCN
#4
OFF
Multi-Function switches
Miller
Reversing Edge
Opening Direction
Photocells
Closing Direction
Photocells
CLOSED Gate
OPENING Direction Edge
OPENING
Direction
Edge
CLOSING
Direction
Edge
OPENING Direction Photocells
CLOSING Direction Photocells
S
ep
arate
Po
w
er
R
ec
e
iv
er
Tr
ansm
itte
r
T
r
a
nsmi
tte
r
Receiver
S
eparate
P
owe
r
MOTOR 15A
OPENING
TIMER
ERD CONTROL
MULTI FUNCTION
GATE STATUSFEATURE SELECTOR
10
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
OPEN
LIMIT
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
M-FCN
#4
#1
COMM PORTINPUT/OUTPUT
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT POWER
11
AVI Slide Rev - C
Control Board
FEATURE SELECTOR
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
234
OFF—ON
SELECT
MOTOR 15A
OPENING
TIMER ERD CONTROL
MULTI FUNCTION
GATE STATUSFEATURE SELECTOR
M/S PHASE
10
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
M-FCN
#4
GND
GND
RCVR
24VAC
#1
COMM PORTINPUT/OUTPUT
RECEIVER ERD M/P
RESET
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT POWER
CONTROL BOARD ADJUSTMENTS AND WIRING
Feature Selector Switches #1 - #4
Control Board Overview
The Feature Selector Descriptions:
NOTE: The power MUST be turned OFF before changing the features selector switches.
Switch #1: Slave/Master - Sets the operator to work as Master or Slave. Single operator
installation MUST be set to MASTER.
Switch #2: Gate Opening - designates left or right opening direction. See page 12.
Switch #3: Motor Brake - If the ON position is selected, the gate will stop instantly when
the limit switch is activated. This is useful for uphill/downhill applications and on all
fail-safe operators.
Switch #4: Close Timer (ON/OFF) - Turns the close timer ON or OFF. See page 14.
M/S Phase
DO NOT remove jumper or operator will NOT function.
Designates communication between master and slave
operators only. M/S operators can be set for the same
or opposite phase, depending on operators
communication (can vary). See page 17.
Reset Button
Press for soft reset of operator (resets board microprocessor,
applies any changes that have been made to switches).
Turns OFF activated alarm. Try this button before preforming
a hard shutdown of operator (turn power switch OFF/ON)
when operator fails.
Multi Function
See page 15
Input/Output Connections
Descriptions - See page 15
Wiring Accessories - See page 16
Fuse
15 Amp
250V
Slow-Blow
Factory Set
ERD Sensor
“Fine Tune”
Adjustment.
Please call
Eagle
Access
before any
adjustment.
See page 14
Master/Slave
See page 17
Radio Receiver
See page 13
See page 14
Not Used
Not Used
Feature Selector
Close Timer - See page 14
Reverse ERD
Sensor
See page 14
Limit Switches
See page 12
12
AVI Slide Rev - C
Input Power Connection
Limit Switches & Open Left/Right
MOTOR 15A
OPENING
TIMER ERD CONTROL
MULTI FUNCTION
GATE STATUSFEATURE SELECTOR
M/S PHASE
10
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
M-FCN
#4
GND
GND
RCVR
24VAC
#1
COMM PORTINPUT/OUTPUT
RECEIVER ERD M/P
RESET
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT POWER
120 VAC Input Power Connection
Setting the: Limit Switches & Open Left or Open Right
WARNING: Eagle Access Control Systems, Inc. is not responsible for
researching and complying with local building codes. Be sure to check
all local building codes before installation.
Be sure that the circuit breaker for the input power is turned OFF
before connecting the input power to the operator.
All operators MUST be properly grounded.
Installing surge protection is recommended.
The limit nuts MUST be set so the
gate stops at the correct open and close
positions. the control board MUST have power
for the limit LEDs when setting the limit nuts.
Adjust the close limit nut FIRST when the gate
is in the closed position.
Removing Release Knob will
allow control board plate to be
rotated up and gain easier
access to limit box, see above.
IMPORTANT: DO NOT cycle the operator before
setting the limit nuts. Damage or injury could occur
if limit nuts are NOT set correctly. (See below)
Limit
Nut LED
Limit
Nut LED
OPEN LEFT OPEN RIGHT
Wire Color Description
Black - 120 VAC input power
White - Neutral input
Green - Ground input
(from an approved grounding method)
CAUTION
CAUTION Be sure that power is turned OFF.
To Set the Limit Nuts:
GATE STATUS
OPEN
LIMIT
OPENING CLOSING CLOSE
LIMIT
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
CLOSE
CLOSE
CLOSE
CLOSE
CLOSE
CLOSE
CLOSE
CLOS
Indicates the direction
the gate is cycling.
250 ft
14 AWG
400 ft
12 AWG
650 ft
10 AWG
1000 ft
8 AWG
2000 ft
125 ft 200 ft 325 ft 500 ft 1000 ft
4 AWG
Single Operator
Dual Operators
Black wire to Black wire.
White wire to White wire.
Green wire to Green wire.
120 VAC
FEATURE SELECTOR
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
With power turned ON, press and
hold spring loaded locking tab
and rotate limit nuts accordingly
until LEDs light. Make sure nuts
are locked in position after
releasing locking tab.
120 VAC Input Power Wire
Locking Tab
Limit
S
witch
Limit
Switch
Limit Nut
Limit Nut
Release Knob
Control
Board
Plate
Limit Box
Control
Board
Plate
Release
Knob
13
AVI Slide Rev - C
Power Fail Operation
Radio Receiver
Power Fail Operation
Make sure power is turned OFF on operator
BEFORE inserting hand crank.
Insert hand crank into hole and rotate to move gate.
Radio Receiver Installation and “Learning” Remote Button
The radio receiver is wired to the control board #1 as shown.
Eagle offers a
wireless keypad.
Sold separately
1. Press and release button on the receiver. LED will turn red.
2. Press button on remote twice and the LED will flash and turn back to green.
3. Repeat steps for other desired remote buttons.
4. To delete all remotes, hold the receiver program button for 8 seconds.
5. The EG650 receiver has a maximum capacity of 30 remotes.
Optional: EG652 receiver has a maximum capacity of 300 remotes.
GND
GND
RCVR
24VAC
#1
RECEIVER
Control Board Connection #1
Blue
Black
Red
Yellow
NOTE: Radio Receiver can be connected to the master or slave o
p
erator for master/slave installation.
PO
WE
RED
BY EAGL
E
AV I
Hand Crank
(5/16” Allen Wrench)
LEARN Remote Button
Radio Receiver
Location
Receiver
Program
Button
Remote Button
Green wire
not used.
LED
Run wires
through hole
in plate.
Run antenna
through hole
to increase
wireless range.
Radio
Receiver
Eagle Part
Number:
EG650
Remote
2
5
8
0
1
4
7
A
3
6
9
B
2
5
8
0
1
4
7
A
3
6
9
B
Eagle Wireless Keypad
Eagle Part Number: EG654
MOTOR 15A
ERD CONTROL
MULTI FUNCTION
GATE STATUS
CLOSING
OPEN
LIMIT
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
M-FCN
#4
GND
GND
RCVR
24VAC
#1
COMM PORTINPUT/OUTPUT
RECEIVER
ON ON STOP N/C
OFF ON PHANTOM
OFF OFF EDGE SENSOR
COMM PORT POWER
E
RD
CO
NTR
O
L
MU
LTI F
U
N
C
TI
O
N
CLOSING
O
O
N
O
N
S
T
O
P N
/C
O
FF
O
N PHANT
O
M
OFF OFF EDGE SENSOR
14
AVI Slide Rev - C
TimerERD Reverse Sensor
MOTOR 15A
OPENING
TIMER ERD CONTROL
MULTI FUNCTION
GATE STATUSFEATURE SELECTOR
M/S PHASE
10
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
M-FCN
#4
GND
GND
RCVR
24VAC
#1
COMM PORTINPUT/OUTPUT
RECEIVER ERD M/P
RESET
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT POWER
OPENING
TIMER ERD CONTROL
MULTI FUNCTION
GATE STATUSFEATURE SELECTOR
M/S PHASE
10
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ ALARM
- 12 VDC
#6
POWER
24VAC
#7
COMM PORTINPUT/OUTPUT
RESET
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT POWERINPUT
/
OUTPUT
TIMERFEATURE SELECTOR
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
234
OFF—ON
SELECT
MIN
MAX
O
Two-Way Adjustable Reverse Sensor / ERD Emergency Reversing Device
Close Timer for a Single or Master Operator
IMPORTANT: The level of sensitivity has to do with the weight of the
gate and the condition of the installation. A heavier gate will require
LESS sensitivity and a lighter gate will require MORE sensitivity.
Only a qualified service technician must make all adjustments to these sensors.
Proper function of reverse sensor (ERD):
When meeting an obstruction in the CLOSING direction, the gate will STOP, reverse direction and return to the FULL OPEN position.
When meeting an obstruction in the OPENING direction, the gate will STOP and reverse its direction and stop again after 4-6 inches. The gate
operator will stay in an “ERD OVERLOAD” state for 5 minutes or until manually reset (Reset button or power switch OFF/ON).
If the gate operator enters overload status two times in a row, the alarm will sound until manually reset.
When adjusting the sensors sensitivity:
TOO sensitive - If the gate stops or reverses by itself.
NOT sensitive enough - If the gate strikes an object
and does NOT stop or reverse.
Fine tune adjustment is ONLY necessary when stopping force
cannot be achieved within normal reverse sensor ERD range.
Three (3) full turns sets ERD in the “Normal Range”:
Turn Clockwise for MORE force beyond normal range.
Turn Counter-Clockwise for LESS force than normal range.
The Control Board has a sensitivity adjustment for the OPENING direction and CLOSING direction of
the gate. Both MUST be adjusted.
Adjustment must be made so that the gate stops and reverses when meeting an obstruction.
NOTE: See page 17 for
master/slave close timer setup.
Switch #1 MUST be ON. Turn the close timer ON (Switch #4) and adjust the TIMER from 1 to 60 seconds (Single operator mode).
OVERLOAD LED: The OVERLOAD
LED warning light will light up when
the gate is heavier than normal for the
operator. During this warning, the
operator will NOT function properly.
CAUTION
Feature Selector #1 and #4 must be ON.
Less
Force
More
Force
More
Force
Less
Force
More
Sensitive
Less
Sensitive
Factory Set ERD Sensor “Fine Tune” Adjustment:
Please call Eagle Access before adjusting this sensor!
Opening
Gate
Direction
Closing
Gate
Direction
Clockwise increases close time.
ERD OVERLOAD
ERD OVER
ERD OVE
RD OVE
RD OVE
RD OVE
RD OVE
RD OV
RD OV
DOV
See page 11 for Features Selector.
E
OPENING
ERD CONTROL
CLOSING
15
AVI Slide Rev - C
Input/Output Connection Descriptions
#2 REVERSE LOOP Input: Momentary or continuous signal - This input is
active only when the gate is closing or when its fully open, if this input is
active. The close timer is disabled. Vehicle loop detectors and photo sensors
should be connected here. Multiple devices may be connected in parallel.
#3 KEY Input:
Close Timer ON - Momentary or continuous signal - Once activated, the
gate will fully open. Activation while the gate is closing will cause
the gate to re-open. Continuous activation while the gate is open will
disable the close timer from automatically closing the gate.
Close Timer OFF - Momentary input - This function must be released and reentered to be recognized. This input is to be used for
COMMAND OPEN / COMMAND CLOSE applications. The first signal will cause the gate to begin opening. The second signal will close the
gate only when the gate is in the fully open position.
Exit Loop: Momentary or continuous signal - Once activated, the gate will fully open. Activation while the gate is closing will cause the gate
to re-open. Continuous activation while the gate is open will disable the close timer from automatically closing the gate.
#4 M-FCN (Multi function) Input: Two Multi function switches need to be set according to type of connection desired.
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
INPUT/OUTPUT
M-FCN
#4
#5 MAGLOCK/24VDC Output: Provides 24 VDC power and relay output for Maglocks or Solenoids.
#6 ALARM/12VDC Output: Factory installed alarm. If the gate hits an obstruction TWICE in a row while closing or opening, the alarm will
sound and system will shut down for 5 minutes if not manually reset. Press reset button or turn power switch OFF and back ON to reset
operator.
#7 POWER/24VAC Output: Provides 24 VAC power. Used to power loop detectors or radio receivers.
EDGE SENSOR (External Entrapment Device(s), multiple devices may be connected in parallel to the
Edge Sensor Input): Momentary or continuous signal - This signal is active when the gate is OPENING
and/or CLOSING.
If activated when the gate is OPENING: (entrapment protection) The gate will stop, pause and
reverse in the close direction for 1 1/2 seconds and stop. Continuous activation will prevent the gate from
moving in the opening direction. If the second activation occurs before the limit switch is activated, the
gate will stop and reverse direction for 1 1/2 seconds and stop. Thus activating the ALARM. At this point,
the operator must be manually reset (Reset button or Power switch OFF/ON) before normal operation can
resume. Check for obstructions before resetting operator.
If activated when the gate is CLOSING: The gate will stop, pause and fully re-open. During this
mode, the timer to close, reverse loop, exit loop are disabled. The key/keypad and receiver will cause the
gate to close if a second activation occurs before the limit switch is activated. The gate will stop and
reverse direction for 1 1/2 seconds and stop again, thus activating the ALARM. At this point, the operator
must be manually reset (Reset button or Power switch OFF/ON) before normal operation can resume.
Check for obstructions before resetting operator.
PHANTOM LOOP (SHADOW LOOP): Not used for slide gate operators.
STOP (Normally Closed): Momentary or continuous signal - This function OVERRIDES all other signals.
Once momentarily activated, the gate will immediately stop and wait for a new command.
If the stop input is continuously activated, the gate will not move. This is used as a “stop button” for
doors built into the gate. When the door is OPEN, door switch is Normally Closed (NC), the gate operator
will NOT function.
CLOSE: Momentary or continuous signal - Once activated the gate will FULLY CLOSE. This is used as a
close button connection ONLY (single-push button, dry contact). If close timer is ON, this input will
override close timer setting.
MULTI FUNCTION
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
1
2
MULTI FUNCTION
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
1
MULTI FUNCTION
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
2
MULTI FUNCTION
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
MOTOR 15A
OPENING
TIMER ERD CONTROL
MULTI FUNCTION
GATE STATUSFEATURE SELECTOR
M/S PHASE
10
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
M-FCN
#4
GND
GND
RCVR
24VAC
#1
COMM PORTINPUT/OUTPUT
RECEIVER ERD M/P
RESET
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT POWER
Input/Output Descriptions
16
AVI Slide Rev - C
Connecting Accessories
Connecting Accessories
Edge
Sensor
Sep
arate
Pow
er
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
INPUT/OUTPUT
M-FCN
#4
Closing-Direction ONLY
Close ONLY
Switch 1 - ON
Switch 2 - OFF
Switch 1 - OFF
Switch 2 - OFF
Photocell Sensor
Entrapment Protection
24 VDC
Max
Maglock or
Solenoid Lock
External Alarm
Reset Button
Receiver
Tran
sm
i
tter
MULTI FUNCTION
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
1
MULTI FUNCTION
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
Single-Push Button (Dry Contact)
Edge Sensor Setting
NOTE: Multiple
sensors can be
connected.
Button will shut off alarm and reset
operator. Install in a secure location if
external alarm reset button is desired in
addition to circuit board reset button.
Provides 24 VDC
and a relay output.
Provides 24 VAC power for
loop detectors, radio receivers
or similar accessories.
Separate
Po
wer
Opening-Direction ONLY
See page 10.
Closing-Direction ONLY
See page 10.
See page 10 for loops position.
See page 10 for loop position.
Entrapment
Photocell
Sensors
External Exit Loop
Detector
Key Switch
Lock Box
Dry Contact
Fire Dept.
Lock Box
Dry Contact
Phone Entry System
Sep
arate
Pow
er
Sep
arate
Power
In-Ground
Ex
i
t Loop
External Reverse Loop
Detector
Separat
e
Power
I
n-Ground
Re
verse Loop
In-Ground
Reverse Loop
Wired in series
Multi Function Input Options
Opening Device Options
Eagle Wireless Keypad
Eagle Part Number: EG654
2
3
2
3
Alar
m
Reset
See connection descriptions on previous page.
Receiver
Tran
sm
i
tter
17
AVI Slide Rev - C
Master / Slave Setup
Master / Slave Setup
IMPORTANT: The 120 VAC power for the master and slave operators MUST be on the SAME circuit breaker.
It is recommended that each gate operator’s initial set-up is completed (Direction of gate travel, limit nuts,
ERD reverse sensor and feature selector switches #1 - #4) before connecting the operators together.
After each operator functions individually, proceed to Master/Slave connection and operation.
Connect Master and Slave Operators Together
Choose your board type (Master or Slave) and use 20
GA stranded wire. Correct polarity is VERY important.
DO NOT cross polarity. Operators will NOT function
properly if not wired correctly. Make sure to use color
coated wire.
Use the Close Timer (Feature
Selector #4 ON) on the master
board ONLY to set the gates
closing time 1 - 60 seconds.
Clockwise increases close time.
ACCESSORIES NOTE: Connect accessories to
the master or slave boards).
See page 16 for accessory wiring connections.
M/S PHASE NOTE: If the Master and Slave
operators are NOT communicating properly,
verify that they are on the same phase by
switching the M/S Phase jumper on either
the master or the slave unit. Make sure to
reset both boards.
Master Operator
Master Board
Slave Board
Slave Operator
Slave
Operator
Master
Operator
Negative to Negative 20 AWG Wire
Positive to Positive 20 AWG Wire
SLAVE MASTER
+ – + –
#9#8
COMM PORTCOMM PORT
SLAVE MASTER
+ – + –
#9#8
COMM PORTCOMM PORT
FEATURE SELECTOR
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
234
OFF—ON
SELECT
O
FEATURE SELECTOR
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
234
OFF—ON
SELECT
NOTE: #1 & #2 switch settings are
based on the illustration above.
TIMER
MIN
MAX
MASTER
Operator
SLAVE
Operator
Opens to the Left
Opens to the Right
MOTOR 15A
GATE STATUSFEATURE SELECTOR
M/S PHASE
10
CLOSING
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
REVERSE
#2
GND
GND
RCVR
RECEIVER ERD M/P
POWER
MOTOR 15A
OPENING
TIMER ERD CONTROL
MULTI FUNCTION
GATE STATUSFEATURE SELECTOR
M/S PHASE
10
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
M-FCN
#4
GND
GND
RCVR
24VAC
#1
COMM PORTINPUT/OUTPUT
RECEIVER ERD M/P
RESET
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT POWER
MOTOR 15A
OPENING
TIMER ERD CONTROL
MULTI FUNCTION
GATE STATUSFEATURE SELECTOR
M/S PHASE
10
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
M-FCN
#4
GND
GND
RCVR
24VAC
#1
COMM PORTINPUT/OUTPUT
RECEIVER ERD M/P
RESET
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT POWER
R
GHT
N
OP
R
Switch #1 MUST be ON. Refer to
page 11 for more information
about each of the features.
Close Timer (Master Operator)
Switch #1 MUST be OFF.
Switch #4 MUST be OFF. Refer to
page 11 for more information
about each of the features.
POWERED BY EAGLE
AV I
POWERED BY EAGLE
AV I
M/S PHASE
10
EATURE SELECTO
MA
S
TER
O
PEN RI
G
H
T
BRAKE
ON
CLOSE TIMER ON
S
LAV
E
O
PEN LEFT
BRAKE
O
F
F
C
L
OS
E TIMER
O
F
F
1
O
N
2
3
4
O
FF—
O
N
S
ELE
C
T
Jumper
18
AVI Slide Rev - C
Troubleshooting
Gate stops and
reverses direction in
mid cycle and the
OVERLOAD LED
remains ON.
(A) Gate operator is not plumb and level.
(B) ERD current sensor may be set too sensitive.
(C) Gate encountered an obstruction while cycling.
(A) The radio receiver’s LED remains on.
(B) One or more of the global input LEDs remain active.
(C) Gate has re-opened because it encountered an obstruction
while closing.
(D) The loop detector LED is on.
(E) CLOSE TIMER is not functioning.
(A) The radio receiver or remote control has
malfunctioned in the “ON” position.
(B) Check input/output connections for a short circuit.
(C) Only #3 “Key” input will resume normal operation.
(D) Reset loop detector. Verify correct loop wiring. Set loop
detector to a different frequency and/or change the sensitivity
of the loop detector.
(E) Be sure Switch #4 is in the “ON” position.
(A) Motor Overload LED is on.
(B) Radio receiver is not “ON” when the remote control
button is activated.
(C) The green “Power” LED is off.
(D) The Fuse is blown.
• Feature selector Switch #1 MUST be set to the “MASTER” (ON) position unless the operator is being used as a slave operator.
• Safety external loop detectors must be connected to the #2 “REVERSE LOOP” input (see pages 15 & 16).
• If the CLOSE TIMER feature is desired, Feature selector Switch #4 MUST be in the “ON” position (see page 11).
• It is OK to call the Eagle Access Customer Service Department with any questions... we are here to serve YOU!
1-800-708-8848
(A) Motor’s built-in thermal breaker has been tripped, let motor
cool down, try again.
(A) Gate is too heavy.
(B) Radio receiver has malfunctioned in the “OFF” position.
(C) Turn ON operator power switch and/or reset the main circuit
breaker.
(D) Check and/or replace the fuse with same amp fuse.
(A) Remount operator.
(B) Turn the ERD current sensor slightly in the clockwise
direction.
(C) Check and remove all obstructions
Gate will not close.
Gate will not open.
SYMPTOMS PROBABLE CAUSE
COMMON OVERSIGHTS TO BE AWARE OF:
REMEDY
MOTOR 15A
OPENING
TIMER ERD CONTROL
MULTI FUNCTION
GATE STATUSFEATURE SELECTOR
M/S PHASE
10
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2 3 4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ – + –
#9#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24VAC
#7
KEY
#3
M-FCN
#4
GND
GND
RCVR
24VAC
#1
COMM PORTINPUT/OUTPUT
RECEIVER ERD M/P
RESET
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT POWER
AVI Wiring Diagram
Red
Black
Capacitor
Yellow N.O.
Limit Switches
Orange N.O.
Green Com
Alarm
White
Red
Blue
Yellow
Orange
1/2 HP
Motor
Power Switch
120 VAC
Input Wires
White
Black
Green
White
Green
Black
Black
OFF
ON
Ground
Blue
Yellow
Red
Black
Eagle
Radio
Receiver
AVI Wiring DiagramTroubleshooting
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24