Allen-Bradley ULTRA 100 Series User manual

  • Hello! I am an AI chatbot trained to assist you with the Allen-Bradley ULTRA 100 Series User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ULTRA 100 Series
Digital Servo Drives
with DeviceNet
7KLVPDQXDOZDVFUHDWHGIRU
'HYLFH1HW)LUPZDUH
Important User
Information
Because of the variety of uses for the products described in this
publication, those responsible for the application and use of this
control equipment must satisfy themselves that all necessary steps
have been taken to assure that each application and use meets all
performance and safety requirements, including any applicable laws,
regulations, codes and standards.
The illustrations, charts, sample programs and layout examples shown
in this guide are intended solely for purposes of example. Since there
are many variables and requirements associated with any particular
installation, Allen-Bradley does not assume responsibility or liability
(to include intellectual property liability) for actual use based upon the
examples shown in this publication.
Allen-Bradley publication SGI-1.1, Safety Guidelines for the
Application, Installation, and Maintenance of Solid-State Control
(available from your local Allen-Bradley office), describes some
important differences between solid-state equipment and
electromechanical devices that should be taken into consideration
when applying products such as those described in this publication.
Reproduction of the contents of this copyrighted publication, in whole
or in part, without written permission of Allen-Bradley Company,
Inc., is prohibited.
Throughout this manual we use notes to make you aware of safety
considerations. For example:
Attention statements help you to:
l identify a hazard
l avoid the hazard
l recognize the consequences
© 1999 Rockwell International Corporation. All rights reserved.
Printed in the United States of America.
UL and cUL are registered trademarks of Underwriters Laboratories.
ATTENTION
!
This symbol identifies information about practices
or circumstances that can lead to personal injury or
death, property damage or economic loss.
TIP
This symbol identifies information that is critical
for successful application and understanding of the
product.
1 Publication 1398-5.4 - December 1999
Table of Contents
Chapter: 1 Safety
Using the ULTRA 100 Series, Digital Servo Drive with DeviceNet . . 1-1
Your Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Electrical Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Voltage Potentials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Motor Power Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Shield Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Mechanical Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Stored Energy Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Chapter: 2 Introduction
Purpose of this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
DeviceNet Interface Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Predefined Master/Slave Connection Set . . . . . . . . . . . . . . . 2-2
Explicit Response/Request Messages . . . . . . . . . . . . . . . . . . 2-2
Polled I/O Command/Response Messages . . . . . . . . . . . . . . 2-2
Change-of-State/Cyclic Messages . . . . . . . . . . . . . . . . . . . . . 2-3
Chapter: 3 Connect to the DeviceNet network
Wiring the open-style connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Chapter: 4 Network configuration of ULTRA 100 Drive with DeviceNet
Setting rotary DIP switches to node address and data rate . . . . . . . 4-1
Configuring the Network using Software . . . . . . . . . . . . . . . . . . . . . . . 4-2
Creating the EDS File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Modifying ULTRA 100 Drive with DeviceNet Configuration Data . . . 4-7
Appendix: A Using Messaging with a
1747-SDN DeviceNet Scanner
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Understanding Messaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
The Scanner Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Communicating with Your Device’s Input/Output Data . . . . . . . . . . .A-2
Communicating with the SLC 500 Processor . . . . . . . . . . . . . . . . . . . .A-3
Scanner Module Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-5
Scanner Module Configuration Table (SCT) . . . . . . . . . . . . .A-5
Scan List Table (SLT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-5
RSNetworx for DeviceNet Software . . . . . . . . . . . . . . . . . . . . . . . . . . .A-6
Explicit Messaging with the 1747-SDN Scanner . . . . . . . . . . . . . . . . .A-6
How it Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-6
How to Format the Explicit Message Transaction block . . . . . .A-7
Publication 1398-5.4 - December 1999
Table of Contents - 2
Appendix: B Polled I/O Examples
Example 1:
RAM Index Setup and Move . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2
Select Command and Response Assembly Object Data . . . . . . .B-2
Set the Logic Command Mask (Parameter 287) . . . . . . . . . . . . . .B-6
Enable the 1747-SDN Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-8
Enable Host Index Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-8
Set the RAM Index type for Absolute Move . . . . . . . . . . . . . . . .B-11
Set the RAM Index Position Using User Defined Scaling . . . . .B-13
Start Index Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-16
Example 2:
Display the Current Position in User Units . . . . . . . . . . . . . . . . . . . . .B-17
Select Command and Response Assembly Object Data . . . . . .B-17
Enable the 1747-SDN Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . .B-23
Read Current Motor Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-23
Appendix: C Explicit Message Examples
Example 1:
RAM Index Setup and Move . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-2
Enable Host Index Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-2
Set the RAM Index Type for Absolute Move . . . . . . . . . . . . . . . . .C-6
Set the RAM Index Position Using User Defined Scaling . . . . . .C-9
Start Index Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-13
Example 2:
Display the Current Position in User Units . . . . . . . . . . . . . . . . . . . . .C-17
Read the Current Motor Position . . . . . . . . . . . . . . . . . . . . . . . . .C-17
Appendix: D Programming Reference
Object Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-2
How Objects Affect Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-3
The Defined Object Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-3
Object Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-4
Data Type Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-5
Identity Object (Class ID 01
H
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-5
Message Router Object (Class ID 02
H
) . . . . . . . . . . . . . . . . . . . . . . . . .D-8
DeviceNet Object (Class ID 03
H
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-8
Assembly Object (Class ID 04
H
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-10
Logic Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-13
Torque Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-14
Integrator Inhibit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-14
Follower Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-14
Operation Mode Override . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-14
Selection Table of Presets . . . . . . . . . . . . . . . . . . . . . . . . . . .D-15
Start Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-15
Define Home . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-15
Disable Serial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-15
Publication 1398-5.4 - December 1999
Table of Contents - 3
Remove COMMAND Offset . . . . . . . . . . . . . . . . . . . . . . . . . .D-15
Start Homing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-16
Fault Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-16
Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-16
Feedback Data Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-16
Command Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-17
Logic Status Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-19
Brake Active . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-19
Drive Ready . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-19
Torque Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-19
Integrator Inhibit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-20
Follower Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-20
Operation Mode Override . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-20
Preset Select A, B, C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-20
At Home . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-20
Sequence Complete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-20
In Motion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-20
In Dwell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-20
Registration Detected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-20
Fault Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-21
Enable Active . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-21
DeviceNet Communication Fault Action . . . . . . . . . . . . . . . . . . .D-21
Using Explicit Messaging to Control the ULTRA 100 . . . . . . . . .D-22
DeviceNet Connection Object (Class ID 05
H
) . . . . . . . . . . . . . . . . . . .D-23
Parameter Object (Class ID 0F
H
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-24
New Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-58
Using the Fault Configured Input . . . . . . . . . . . . . . . . . . . . . . . . . .D-61
Get_Attribute_All Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-64
Parameter Group Object (Class ID 10
H
) . . . . . . . . . . . . . . . . . . . . . . .D-66
Acknowledge Handler Object (Class ID 2B
H
) . . . . . . . . . . . . . . . . . . .D-76
Appendix: E Problem Solving
Operator-level diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1
LED displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1
Node Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3
Device Failure - LED Status Check . . . . . . . . . . . . . . . . . . . . . . . . . E-3
Scanner Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3
Wiring Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4
Power Supply Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4
Cable Installation and Design Problems . . . . . . . . . . . . . . . . . . . . E-5
Adjusting the Physical Network Configuration . . . . . . . . . . . . . . . E-5
Appendix: F Specifications
DeviceNet Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1
Publication 1398-5.4 - December 1999
Table of Contents - 4
1 Publication 1398-5.4 - December 1999
Chapter
1
Safety
Using the ULTRA 100 Series,
Digital Servo Drive with
DeviceNet
,WLVUHFRPPHQGHGWKDW\RXDOVRUHDGWKH8/75$6HULHV,QVWDOODWLRQ0DQXDO
SXEOLFDWLRQLQDGGLWLRQWRWKLVPDQXDOEHIRUHDWWHPSWLQJWRLQVWDOORU
RSHUDWHWKH8/75$'ULYHZLWK'HYLFH1HW%\UHDGLQJWKHPDQXDOV\RX
ZLOOEHFRPHPRUHIDPLOLDUZLWKVDIHSUDFWLFHVDQGSURFHGXUHVIRURSHUDWLRQRI
WKH8/75$'ULYHZLWK'HYLFH1HW7KLVPDQXDOSURYLGHV'HYLFH1HW
VSHFLILFLQIRUPDWLRQ8VHWKH8/75$ 6HULHV,QVWDOODWLRQ0DQXDOSXEOLFDWLRQ
IRUUHIHUHQFHLQIRUPDWLRQDERXWLQWHUIDFHZLWKWKHGULYH
Your Responsibilities
7KHHTXLSPHQWGHVFULEHGLQWKHVHPDQXDOVDUHLQWHQGHGIRUXVHLQDQLQGXVWULDO
HQYLURQPHQW3HUVRQDOLQMXU\DQGGDPDJHWRHTXLSPHQWFDQUHVXOWIURPQRW
IROORZLQJDOODSSOLFDEOHVDIHW\FRGHVSURFHGXUHVDQGUHTXLUHPHQWV
$VDTXDOLILHGXVHURULQVWDOOHURIWKLVGHYLFH\RXDUHUHVSRQVLEOHIRU
GHWHUPLQLQJWKHVXLWDELOLW\RIWKHSURGXFWIRUWKHLQWHQGHGDSSOLFDWLRQ
5RFNZHOO$XWRPDWLRQLVQHLWKHUUHVSRQVLEOHQRUOLDEOHIRULQGLUHFWRUDQ\
FRQVHTXHQWLDOGDPDJHUHVXOWLQJIURPWKHLQDSSURSULDWHXVHRIWKLVSURGXFW
$TXDOLILHGSHUVRQRULQVWDOOHULVVRPHRQHZKRLVIDPLOLDUZLWKDOOVDIHW\
UHTXLUHPHQWVDQGHVWDEOLVKHGVDIHW\SUDFWLFHVUHODWLQJWRWKHLQVWDOODWLRQ
RSHUDWLRQDQGPDLQWHQDQFHRIWKLVHTXLSPHQW)RUPRUHGHWDLOHGGHILQLWLRQV
UHIHUWR,(&
,WLVUHFRPPHQGHGWKDWDQ\RQHZKRRSHUDWHVRUPDLQWDLQVHOHFWULFDORU
PHFKDQLFDOHTXLSPHQWVKRXOGKDYHDEDVLFNQRZOHGJHRI)LUVW$LG$VD
PLQLPXPWKH\VKRXOGNQRZWKHORFDWLRQRI)LUVW$LGHTXLSPHQWDQGWKH
LGHQWLW\RIWKHGHVLJQDWHG)LUVW$LGSHUVRQQHOLQWKHDUHD
Publication 1398-5.4 - December 1999
1-2 Safety
Installation
$VDIHDWWLWXGHLVHVVHQWLDOWR´ZRUNLQJVDIHµLQDQ,QGXVWULDO(QYLURQPHQW
%HLQJVDIHLVLPSRUWDQWWR\RXDQGWKRVHZRUNLQJDURXQG\RX6DIHW\ODEHOLQJ
RQHTXLSPHQWGRHVQRWUHSUHVHQWDQDOOLQFOXVLYHVHWRILQVWUXFWLRQWRHQVXUH
VDIHRSHUDWLRQRIHTXLSPHQW6DIHW\ODEHOLQJLVRQO\PHDQWWREHDJXLGHDQG
UHPLQGHURIVDIHW\KD]DUGV<RXVKRXOGNQRZZKDWKD]DUGVDUHDVVRFLDWHGZLWK
HTXLSPHQWLQ\RXUDUHDEHIRUHDWWHPSWLQJDQ\ZRUNRQDQ\HTXLSPHQW,I\RX
ZLVKIXUWKHULQIRUPDWLRQSOHDVHFRQWDFW\RXUQHDUHVWVDIHW\UHSUHVHQWDWLYH
7KHJHQHUDOKD]DUGVWKDWPD\EHHQFRXQWHUHGZLWKWKHXVHRIWKLVHTXLSPHQW
DUHHOHFWULFDOPHFKDQLFDODQGVWRUHGHQHUJ\
Electrical Hazards
3URSHUVL]LQJDQGLQVWDOODWLRQSURFHGXUHVDUHUHTXLUHGIRUHOHFWULFDOSRZHU
HTXLSPHQWLQDQLQGXVWULDOHQYLURQPHQW,QVWDOODWLRQPXVWEHXQGHUWDNHQE\
TXDOLILHGSHUVRQQHO
ATTENTION
!
2EVHUYHDOODSSOLFDEOHORFDOQDWLRQDODQGLQWHUQDWLRQDO
VDIHW\FRGHVZKHQXVLQJWKLVHTXLSPHQW
:LULQJSUDFWLFHVJURXQGLQJGLVFRQQHFWVDQGRYHUFXUUHQW
SURWHFWLRQDUHRISDUWLFXODULPSRUWDQFH
)DLOXUHWRREVHUYHVDIHW\FRGHVFRXOGUHVXOWLQSHUVRQDO
LQMXU\DQGRUGDPDJHWRHTXLSPHQW
ATTENTION
!
+LJKYROWDJHLVSUHVHQWRQWKHWHUPLQDOVRIWKH8/75$
'ULYHZLWK'HYLFH1HW
$IWHUUHPRYLQJSRZHUFKHFNIRUUHPDLQLQJYROWDJHEHIRUH
PDNLQJRUUHPRYLQJDQ\FRQQHFWLRQ
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
ATTENTION
!
*URXQGWKH8/75$'ULYHZLWK'HYLFH1HWHQFORVXUH
(QVXUHWKDWWKHGHYLFHHQFORVXUHLVFRQQHFWHGWRDVDIHW\
HDUWKJURXQG
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
Publication 1398-5.4 - December 1999
Safety 1-3
Voltage Potentials
9ROWDJHSRWHQWLDOVIRUWKHLQWHUQDODPSOLILHUFLUFXLWU\YDU\IURP9ROWV
DERYHWR 9ROWVEHORZHDUWKJURXQGZLWKD9ROWLQSXW9ROWDJHVFDQ
H[FHHG9'&RU9$&ZLWKLQWKH8/75$'ULYHZLWK'HYLFH1HW
$OOFLUFXLWVLQFOXGLQJWKHFRQQHFWLRQVRQWKHIURQWSDQHOVKRXOGEHFRQVLGHUHG
´KRWµZKHQSRZHULVFRQQHFWHGDQGDIWHUSRZHULVUHPRYHGIRUWKHOHQJWKRI
WLPHVSHFLILHGLQWKHZDUQLQJRQWKHIURQWRIWKHDPSOLILHU
Motor Power Cabling
7HUPLQDOEORFNFRQQHFWLRQVWKURXJKFRQQHFWWKHGHYLFHWRWKHZLQGLQJVRI
WKHPRWRU,IWKHVHFRQQHFWLRQVJHWFURVVHGWKHPRWRUFDQLPPHGLDWHO\VWDUW
WRUXQZLWKQRFRQWURODWIXOOUSP
ATTENTION
!
6WDWLFGLVFKDUJHRFFXUULQJDWWKH'HYLFH1HWFRQQHFWRURQ
WKH8/75$ZLWK'HYLFH1HWPD\FDXVHDPDOIXQFWLRQ
6WDWLFFRQWUROSUHFDXWLRQVDUHUHTXLUHGZLWKZLUH
FRQQHFWLRQVWRWKH8/75$'ULYHZLWK'HYLFH1HW
5HIHUWR*XDUGLQJ$JDLQVW(OHFWURVWDWLF'DPDJHSXEOLFDWLRQ
RURWKHUDSSOLFDEOH(6'SURWHFWLRQKDQGERRN
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
ATTENTION
!
/RRVHHOHFWULFDOFRQWDFWVFDQFDXVHDILUH
6ROGHURQFRQWDFWVFDQORRVHQRYHUWLPH'RQRWWLQ
VROGHUH[SRVHGOHDGVRQFDEOHVJRLQJWRKLJKYROWDJH
WHUPLQDOV
)DLOXUHWRREVHUYHWKLVVDIHW\SUDFWLFHFRXOGUHVXOWLQ
LQWHUPLWWHQWVHUYLFHDQGRUGDPDJHWRHTXLSPHQW
ATTENTION
!
:LUHPRWRUVLJQDOFRQQHFWLRQVFRUUHFWO\EHWZHHQWKH
PRWRUDQGDPSOLILHU
(QVXUH567DQGJURXQGFRQQHFWLRQVDUHFRUUHFWEHIRUH
DWWDFKLQJDPRWRULQWRDV\VWHP,IZLUHVDUHFURVVHG
PRWRUVFDQLPPHGLDWHO\UXQDWIXOOUSPVZLWKQRFRQWURO
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFDQUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
Publication 1398-5.4 - December 1999
1-4 Safety
Shield Termination
0RWRUSRZHUFDEOHVDUHVKLHOGHG7KHSRZHUFDEOHVKLHOGLVGHVLJQHGWREH
JURXQGHGGXULQJWKH8/75$'ULYHZLWK'HYLFH1HWLQVWDOODWLRQ$VPDOO
SRUWLRQRIWKHFDEOHMDFNHWLVVWULSSHGZKLFKH[SRVHVWKHVKLHOGZLUHV7KH
H[SRVHGDUHDPXVWEHFODPSHGDWWKHERWWRPRIWKHDPSOLILHUFKDVVLVXVLQJWKH
FODPSSURYLGHG,WLVFULWLFDOIRU(0&SHUIRUPDQFHWKDWWKHVKLHOGZLUHVEH
FODPSHGDJDLQVWWKHDUHDRIWKHFKDVVLVZKLFKLVQRWSDLQWHG
Terminal block for DC bus and motor connections
Position Identifier Description
1 DC BUS+ DC Bus+ voltage
2 DC BUS- DC Bus- voltage
3 L1 (Line 1) 100-240 VAC input power
4 L2/N (Line 2) 100-240 VAC input power
5 Ground Symbol Safety (earth) ground
6 R R phase power to motor
7 S S phase power to motor
8 T T phase power to motor
9 Ground Symbol Motor case ground
ATTENTION
!
(QVXUHDOOPRWRUZLULQJLVFRQQHFWHGVHFXUHO\WRWKH
WHUPLQDOVRQWKH8/75$'ULYHZLWK'HYLFH1HW
/RRVHZLUHVFDQFDXVHILUHDQGRUVWUD\VWDWLFGLVFKDUJH
$OZD\VUHPRYHSRZHUEHIRUHPDNLQJRUUHPRYLQJDQ\
FRQQHFWLRQRQWKH8/75$'ULYHZLWK'HYLFH1HW
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
ATTENTION
!
*URXQGVKLHOGLQJRQSRZHUFDEOHV
+LJKYROWDJHSRWHQWLDOVFDQEHGLVFKDUJHGIURPWKHVKLHOG
LILWLVQRWJURXQGHGWRWKHHQFORVXUHRIWKHGHYLFH
)DLOXUHWRJURXQGDVKLHOGHGSRZHUFDEOHWRWKHGHYLFHFDQ
UHVXOWLQSHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
Publication 1398-5.4 - December 1999
Safety 1-5
Figure 1.1
Motor Power EMC Shield Connection (on bottom of Drive)
ATTENTION
!
'RQRWFRQQHFWWRWKHLQWHUQDOFLUFXLWU\RIWKH8/75$
'ULYHZLWK'HYLFH1HW
7HUPLQDODQGSOXJFRQQHFWLRQVRQWKHIURQWSDQHODUHWKH
RQO\SRLQWVZKHUHFRQQHFWLRQVVKRXOGEHPDGH
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
ATTENTION
!
7KH'&WHUPLQDOFRQQHFWRUVKRXOGQHYHUEHFRQQHFWHGWR
HDUWKJURXQG
7KH8/75$'ULYHZLWK'HYLFH1HWUHTXLUHVDIORDWLQJ
'&EXV
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
Masked area
Shield
Cable Jacket
T
Power cable shield termination clamp on bottom of DDM-005, DDM-009 and DDM-019
Power cable shield termination clamp on bottom of DDM-005(X) DN, DDM-009(X) DN, DDM-019(X) DN.
Publication 1398-5.4 - December 1999
1-6 Safety
Mechanical Hazards
0HFKDQLFDOKD]DUGVDUHW\SLFDOO\DVVRFLDWHGZLWKWKHDXWRPDWLFPRYHPHQWRI
PDFKLQHFRQWUROOHGURWDWLQJDQGUHFLSURFDWLQJHTXLSPHQW$SSURSULDWH
SUHFDXWLRQVPXVWEHWDNHQWRHQVXUHSRZHUWRWKHGHYLFHLVGLVFRQQHFWHG
EHIRUHSHUVRQQHOKDYHDFFHVVWRWKHPRYLQJSDUWVRIDV\VWHP
ATTENTION
!
6HFXUHPRXQWLQJRIDOOPRYLQJFRPSRQHQWVEHIRUH
SRZHULQJDV\VWHP
0RWRUVDQGOLQNDJHVPXVWEHVHFXUHO\PRXQWHGEHIRUHD
V\VWHPLVRSHUDWHG'LVDVVHPEOHGHTXLSPHQWVKRXOGEH
DSSURSULDWHO\LGHQWLILHGWDJJHGRXWDQGDFFHVVWRHOHFWULFDO
SRZHUUHVWULFWHGORFNHGRXW
)DLOXUHWRREVHUYHWKHVHVDIHW\SURFHGXUHVFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
ATTENTION
!
5HVWULFWFDVXDOFRQWDFWWRHTXLSPHQW
7KH8/75$'ULYHZLWK'HYLFH1HWDQGDQ\H[WHUQDO
VKXQWGHYLFHVVKRXOGEHLQVWDOOHGLQDQLQGXVWULDOO\UDWHG
FDELQHWWRSURYLGHGHYLFHSURWHFWLRQDQGUHVWULFWHGDFFHVV
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
H[SRVXUHWRHOHFWULFDOKD]DUGVDQGRUGDPDJHWR
HTXLSPHQW
ATTENTION
!
$YRLGFRQWDPLQDWLQJHOHFWURQLFFRPSRQHQWV
3URYLGHDTXDOLW\DLUVRXUFHWRFDELQHWVIUHHRIGHEULVRLO
FRUURVLYHVRUHOHFWULFDOO\FRQGXFWLYHFRQWDPLQDWHV$OO
FDELQHWVVKRXOGKDYHVFKHGXOHGLQVSHFWLRQVDQGEHFOHDQHG
DVQHHGHG
)DLOXUHWRREVHUYHWKHVHVDIHW\SURFHGXUHVFRXOGUHVXOWLQ
EUHDNGRZQDQGRUGDPDJHWRHTXLSPHQW
Publication 1398-5.4 - December 1999
Safety 1-7
Stored Energy Hazards
6WRUHGHQHUJ\KD]DUGVDUHERWKHOHFWULFDODQGPHFKDQLFDO
(OHFWULFDOKD]DUGVFDQEHDYRLGHGE\GLVFRQQHFWLQJWKH8/75$'ULYHZLWK
'HYLFH1HWIURPLWVSRZHUVRXUFHDQGPHDVXULQJWKH'&EXVYROWDJHWRYHULI\
LWLVDWDVDIHOHYHO:DLWIRUWKHWLPHLQGLFDWHGLQWKHZDUQLQJRQWKHIURQWRI
WKHDPSOLILHUSULRUWRUHPRYLQJWKHSURWHFWLYHFRYHURUWRXFKLQJDQ\
FRQQHFWLRQV
0HFKDQLFDOKD]DUGVUHTXLUHDULVNDQDO\VLVRQWKHHIIHFWVRIDQ\VWRUHG
PHFKDQLFDOHQHUJ\DVZHOODVWKHSRWHQWLDOIRUWKHFRQYHUVLRQRIHOHFWULFDO
HQHUJ\VWRUHGLQWKH8/75$'ULYHZLWK'HYLFH1HWEHLQJFRQYHUWHGWR
PHFKDQLFDOHQHUJ\$XWRPDWLFPRYHPHQWRIPDFKLQHFRQWUROOHGURWDWLQJDQG
UHFLSURFDWLQJHTXLSPHQWFDQRFFXUIURPWKHVWRUHGHQHUJ\LQDV\VWHP
ATTENTION
!
+LJKYROWDJHLVSUHVHQWRQWKH'&%XVDQGWHUPLQDOEORFN
FRQQHFWLRQVIRUVHYHUDOPLQXWHVDIWHUHOHFWULFDOSRZHULV
UHPRYHG
0HDVXUHUHPDLQLQJYROWDJHRQWKHWHUPLQDOEORFNSULRUWR
UHPRYLQJWKHSURWHFWLYHFRYHURUWRXFKLQJDQ\FRQQHFWLRQV
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
ATTENTION
!
+LJKHQHUJ\LVWHPSRUDULO\VWRUHGLQV\VWHPFRPSRQHQWV
HYHQZKHQHTXLSPHQWLVVWRSSHG
+LJKHOHFWULFDODQGPHFKDQLFDOHQHUJ\FDQEHVWRUHGLQ
GHYLFHVDQGV\VWHPOLQNDJHV&KHFNDQGGLVVLSDWHDQ\VWRUHG
HQHUJ\EHIRUHZRUNLQJRQHTXLSPHQW
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
Publication 1398-5.4 - December 1999
1-8 Safety
Safety Guidelines
7KHIROORZLQJSRLQWVVKRXOGEHREVHUYHGIRUWKHVDIHW\RISHUVRQQHODQG
HTXLSPHQW
6\VWHPDQGVDIHW\GRFXPHQWDWLRQPXVWEHPDGHDYDLODEOHDQGREVHUYHGDW
DOOWLPHV
2QO\TXDOLILHGSHUVRQQHOIDPLOLDUZLWKWKHHTXLSPHQWDUHSHUPLWWHGWR
LQVWDOORSHUDWHDQGPDLQWDLQLW
$OOQRQTXDOLILHGSHUVRQQHODUHSK\VLFDOO\UHVWULFWHGIURPWKHHTXLSPHQW
6\VWHPVPXVWEHLQVWDOOHGLQDFFRUGDQFHZLWKDOODSSOLFDEOHVDIHW\DQG
UHJXODWRU\FRGHV
7KHHTXLSPHQWLVLQWHQGHGIRUSHUPDQHQWFRQQHFWLRQWRDPDLQSRZHU
LQSXW,WLVQRWLQWHQGHGIRUXVHZLWKDSRUWDEOHSRZHULQSXW
ATTENTION
!
&RPPLVVLRQLQJWKH8/75$'ULYHZLWK'HYLFH1HWFDQ
GLVUXSWQHWZRUNFRPPXQLFDWLRQV(QVXUH\RXUGHYLFHLV
QRWFRQQHFWHGWRDOLYH'HYLFH1HWQHWZRUN
6HWWKHQRGHDGGUHVVDQG'DWD5DWHYLDWKHURWDU\',3
VZLWFKHVZLWKWKH'HYLFH1HWFDEOHGLVFRQQHFWHGIURPWKH
8/75$'ULYHZLWK'HYLFH1HWRUWKHSRZHUWXUQHGRII
DWLWVVXSSO\
ATTENTION
!
7RVDIHO\VKXWGRZQGRQRWWRJJOHWKH(1$%/(LQSXW
FRPPDQG
$OZD\VUHPRYHSRZHUWRWKH8/75$'ULYHZLWK
'HYLFH1HWEHIRUHPDLQWDLQLQJRUUHSDLULQJWKHXQLW
)DLOXUHWRREVHUYHWKLVVDIHW\SURFHGXUHFRXOGUHVXOWLQ
SHUVRQDOLQMXU\DQGRUGDPDJHWRHTXLSPHQW
1 Publication 1398-5.4 - December 1999
Chapter
2
Introduction
Purpose of this manual
7KLVPDQXDOLVLQWHQGHGWREHXVHGE\SHUVRQVXVLQJWKH8/75$'ULYH
ZLWK'HYLFH1HW7KLVLQFOXGHV8/75$'ULYHZLWK'HYLFH1HW'1
;'1'1;'1'1RU;'1
7KH'HYLFH1HWQHWZRUNLVDQRSHQJOREDOLQGXVWU\VWDQGDUGFRPPXQLFDWLRQ
QHWZRUNGHVLJQHGWRSURYLGHDQLQWHUIDFHWKURXJKDVLQJOHFDEOHIURPD
SURJUDPPDEOHFRQWUROOHUGLUHFWO\WR´VPDUWµGHYLFHVVXFKDVVHQVRUVSXVK
EXWWRQVPRWRUVWDUWHUVVLPSOHRSHUDWRULQWHUIDFHVDQGGULYHV
DeviceNet Interface
Description
7KH8/75$'ULYHZLWK'HYLFH1HWFRQQHFWRUDQGLQWHUIDFHDOORZVIRU
FRQQHFWLRQWRD'HYLFH1HWQHWZRUN
Figure 2.1
ULTRA 100 Drive with DeviceNet
V+
V–
Can_H
Can_L
Shield
MSD
LSD
Node Address
(00-63, PGM)
Data Rate
125KB
250KB
500KB
Autobaud
Network
Status
Module
Status
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
A
llen
B
rad
ley
U
l
t
r
a
S
e
r
i
e
s
Publication 1398-5.4 - December 1999
2-2 Introduction
Predefined Master/Slave Connection Set
$VHWRIPHVVDJLQJFRQQHFWLRQVWKDWIDFLOLWDWHFRPPXQLFDWLRQVDQGLVW\SLFDOO\
VHHQLQDPDVWHUVODYHUHODWLRQVKLSLVNQRZQDVWKH3UHGHILQHG0DVWHU6ODYH
&RQQHFWLRQVHW7KHPDVWHULVWKHGHYLFHWKDWJDWKHUVDQGGLVWULEXWHV,2GDWD
IRUWKHSURFHVVFRQWUROOHU$'HYLFH1HWPDVWHUVFDQVLWVVODYHGHYLFHVEDVHGRQ
DVFDQOLVWLWFRQWDLQV$VODYHGHYLFHUHWXUQV,2GDWDWRLWVPDVWHUGHYLFH7KH
,2GDWDH[FKDQJHGRYHUWKLVFRQQHFWLRQLVSUHGHILQHG
7KHSURFHVVFRQWUROOHUQRUPDOO\D3/&RUDFRPSXWHUUXQQLQJ3/&HPXODWLRQ
VRIWZDUHFDQUHFHLYHLQIRUPDWLRQWKURXJKDPDVWHUVFDQQLQJGHYLFHDQGD
8/75$'ULYHZLWK'HYLFH1HW7KH8/75$'ULYHZLWK'HYLFH1HW
VXSSRUWV([SOLFLW3ROOHG ,2&KDQJH RI 6WDWHDQG&\FOLF 0HVVDJLQJ
Explicit Response/Request Messages
([SOLFLWUHTXHVWPHVVDJHVDUHXVHGWRSHUIRUPRSHUDWLRQVVXFKDVUHDGLQJDQG
ZULWLQJDWWULEXWHV([SOLFLWUHVSRQVHPHVVDJHVLQGLFDWHWKHUHVXOWVRIWKH
DWWHPSWWRVHUYLFHDQH[SOLFLWUHTXHVWPHVVDJH:LWKLQWKHVODYHGHYLFHH[SOLFLW
UHTXHVWVDQGUHVSRQVHVDUHUHFHLYHGDQGWUDQVPLWWHGE\DVLQJOHFRQQHFWLRQ
REMHFW
Polled I/O Command/Response Messages
7KH3ROOFRPPDQGLVDQ,2PHVVDJHWUDQVPLWWHGE\WKHPDVWHUGHYLFH$3ROO
FRPPDQGLVGLUHFWHGWRZDUGDVSHFLILFVODYHGHYLFH$VHSDUDWH3ROOFRPPDQG
PXVWEHVHQWWRHDFKVODYHGHYLFHWKDWLVWREHSROOHG7KH3ROOUHVSRQVHLVWKH
,2PHVVDJHWKDWWKHVODYHGHYLFHWUDQVPLWVEDFNWRWKHPDVWHUGHYLFH:LWKLQ
WKHVODYHGHYLFH3ROOFRPPDQGVDQGUHVSRQVHVDUHUHFHLYHGDQGWUDQVPLWWHGE\
DVLQJOHFRQQHFWLRQREMHFW
Publication 1398-5.4 - December 1999
Introduction 2-3
Change-of-State/Cyclic Messages
$&KDQJH RI 6WDWH&\FOLFPHVVDJHLVGLUHFWHGWRZDUGVDVLQJOHVSHFLILFQRGH
PDVWHURUVODYH$Q$FNQRZOHGJHUHVSRQVHPD\RUPD\QRWEHUHWXUQHGWR
WKLVPHVVDJH,QWKHPDVWHURUVODYHGHYLFHWKHSURGXFLQJ&KDQJH RI 6WDWH
PHVVDJHDQGWKHFRQVXPLQJ$FNQRZOHGJHPHVVDJHDUHUHFHLYHGWUDQVPLWWHG
E\RQHFRQQHFWLRQREMHFW
7KHFRQVXPLQJ&KDQJH RI 6WDWHPHVVDJHDQGSURGXFLQJ$FNQRZOHGJH
PHVVDJHVDUHUHFHLYHGWUDQVPLWWHGE\DVHFRQGFRQQHFWLRQREMHFW
8/75$'ULYHZLWK'HYLFH1HWLPSOHPHQWVWKH8QFRQQHFWHG0HVVDJH
0DQDJHU8&00ZKLFKLVXVHGWRHVWDEOLVKDQH[SOLFLWPHVVDJH
FRQQHFWLRQ7KLVFRQQHFWLRQLVWKHQXVHGWRPRYHLQIRUPDWLRQIURPRQH
QRGHWRDQRWKHU
)DXOWHGQRGH5HFRYHU\DOORZVWKHQRGHDGGUHVVRIDGHYLFHWREHFKDQJHG
HYHQZKHQLWLVIDXOWHGRQWKHQHWZRUN7KLVIHDWXUHUHTXLUHVWKHVXSSRUWRI
SURSHU3&VRIWZDUHWRROV
8VHUFRQILJXUHG)DXOW5HVSRQVHSURYLGHVWKHDELOLW\WRFXVWRPL]H
FRPPXQLFDWLRQHUURUPHVVDJHVWRWKHGULYHDFWLRQV
Publication 1398-5.4 - December 1999
2-4 Introduction
1 Publication 1398-5.4 - December 1999
Chapter
3
Connect to the DeviceNet network
$'HYLFH1HWQHWZRUNLVDDUUDQJHPHQWRIHOHFWULFDOSRZHUDQGGHYLFH
GLVWULEXWLRQ$'HYLFH1HWQHWZRUNLVSODQQHGDQGDGMXVWHGIRURSWLPDO
FRPPXQLFDWLRQV
%HIRUHSURFHHGLQJWRDGGGHYLFHV\RXQHHGWRUHFRUGWKHIROORZLQJ
QHWZRUNGDWDUDWH
QHWZRUNFDEOHV\VWHPPDSWRSRORJ\WRZKLFK\RXDUHFRQQHFWLQJ
GLVWDQFHVEHWZHHQFDEOHV\VWHPFRPSRQHQWV
GHYLFHFXUUHQWGUDZDQGYROWDJHGURSIRUHDFKGHYLFHRQWKHQHWZRUNDQG
OLPLWDWLRQRIWKHWUXQNDQGGURSFDEOHV
5HIHUWRWKHIROORZLQJUHFRPPHQGHGWUXQNDQGGURSOHQJWKV
5HIHUWRWKH'HYLFH1HW&DEOH6\VWHP3ODQQLQJDQG,Q VWDOODWLRQ0DQXDOSXEOLFDWLRQ
'1IRUVSHFLILFJXLGDQFHLQFDOFXODWLQJDQGDWWDFKLQJWKH8/75$
'ULYHZLWK'HYLFH1HWWRDQHWZRUN
Data Rates 125 Kbps 250 Kbps 500 Kbps
Thick Trunk Line 500 m (1,640 ft.) 250 m (820 ft.) 100 m (328 ft.)
Thin Trunk Lengths 100 m (328 ft.) 100 m (328 ft.) 100 m (328 ft.)
Maximum Drop Length 6 m (20 ft.) 6 m (20 ft.) 6 m (20 ft.)
Cumulative Drop Budget 156 m (512 ft.) 78 m (256 ft.) 39 m (128 ft.)
Publication 1398-5.4 - December 1999
3-2 Connect to the DeviceNet network
Wiring the open-style
connector
7RDWWDFKDSOXJDEOHRSHQVW\OHVFUHZFRQQHFWRUWRWKH'HYLFH1HWFDEOH
 6WULSPPLQWRPPLQRIWKHRXWHUMDFNHWIURPWKHHQGRIWKH
OLQHOHDYLQJQRPRUHWKDQPPLQRIWKHEUDLGHGVKLHOGH[SRVHG
 :UDSWKHHQGRIWKHOLQHZLWKPPLQRIVKULQNZUDSFRYHULQJSDUWRI
WKHH[SRVHGZLUHVDQGSDUWRIWKHWUXQNOLQHLQVXODWLRQ
 6WULSPPLQRIWKHLQVXODWLRQIURPWKHHQGRIHDFKRIWKHLQVXODWHG
ZLUHV7ULPWKHODVWPPLQRIWKHEDUHZLUHVVRWKDWWKHRXWVLGH
GLPHQVLRQGRHVQRWH[FHHGPPLQ
 ,QVHUWHDFKZLUHLQWRWKHDSSURSULDWHFODPSLQJFDYLW\RIWKHSOXJDEOHVFUHZ
FRQQHFWRUDFFRUGLQJWRWKHFRORURIWKHFDEOHLQVXODWLRQ7LJKWHQWKH
FODPSLQJVFUHZVWRVHFXUHHDFKZLUH
/