Fujitsu UTG-UGGB-W Installation guide

Type
Installation guide

Fujitsu UTG-UGGB-W is a cassette-type air conditioner that provides efficient and reliable cooling and heating solutions for various indoor spaces. With its advanced features, it ensures optimal comfort and convenience for users. This air conditioner is designed for easy installation and maintenance, making it a suitable choice for both residential and commercial applications.

Fujitsu UTG-UGGB-W is a cassette-type air conditioner that provides efficient and reliable cooling and heating solutions for various indoor spaces. With its advanced features, it ensures optimal comfort and convenience for users. This air conditioner is designed for easy installation and maintenance, making it a suitable choice for both residential and commercial applications.

En-1
PART No. 9378730083
1. SAFETY PRECAUTIONS
WARNING
This mark indicates procedures which, if
improperly performed, might lead to the
death or serious injury of the user.
Never touch electrical components immediately after the power
supply has been turned off. Electrical shock may occur. After
turning off the power, always wait 5 minutes or more before
touching electrical components.
For the air conditioner to operate satisfactorily, install as outlined
in this installation manual.
Do not turn on the power until all installation work is complete.
CAUTION
This mark indicates procedures which, if
improperly performed, might possibly result
in personal harm to the user, or damage to
property.
The louver angle can not be changed if the power is not on.
(If moved by hand, it may be damaged.)
Please refer to the INSTALLATION MANUAL attached to the
indoor unit during installation.
Let the customer keep this INSTALLATION MANUAL because
it is needed when changing the direction of INTAKE GRILLE
or the lter maintenance.
Do not suspend very heavy weights from the INTAKE GRILLE.
2. ACCESSORIES
• The following installation parts are furnished. Use them as
required.
Name and shape Q’ty Application
Hexagon Screw
4
For mounting decoration panel
Screw
4
For installing grille holding wire
Strap
4
For installing corner panel
Grille holding Wire
2
For installing intake grille
INSTALLATION MANUAL
AIR CONDITIONER
OPTIONAL PARTS
CASSETTE GRILLE
For authorized service personnel only.
UTG-UG
*
B-W
3. INSTALLATION PROCEDURE
3.1. REMOVE THE INTAKE GRILLE
(1) Slide the 2 grille hook
(2) Open the intake grille and remove.
Corner panel
(3) Remove the corner panel (4 Positions).
3.2. INSTALL PANEL TO INDOOR UNIT
When installing the main indoor unit, please refer to the instructions on
supplied installation manual.
(1) Install the decoration panel on the indoor unit.
Align the stamped marks on the decoration panel against the pipe and
the drain of the indoor unit.
DRAIN
PIPE
“Drain”
“Pipe”
“Drain side”
“Piping side”
• Temporarily tighten at 2 positions with metal ttings.
English
En-2
CAUTION
Use only the supplied screws to install the decoration panel.
Install so that there is no gap between the decoration panel and
the air conditioner body.
I
f there is a gap, an error will occur as shown in the diagram below.
Tighten the screw securely so that there will not be a gap.
Condensation
Air leakage
Dirty ceiling
Condensation, dew drops
• Install with 4 hexagon screws.
Hexagon
screw
Ensure that there is no
gap between the hook
and the decoration panel
(4 Positions)
No Gap
When there is a gap between the ceiling
and the decoration panel even when the
screw is tightened, readjust the height of the
main indoor unit.
As long as it does not affect the levelness
of the main indoor unit and the drain pip-
ing, you may adjust the height of the main
indoor unit from the hole at the corner of the
decoration panel, with the decoration panel
still attached to the main indoor unit.
Tighten the screw until the seal material between the decoration panel
and the main indoor unit is compressed to a thickness of 5 to 7 mm
(3/16 to 9/32 in.).
Indoor unit
Ceiling
No gap between ceiling and decoration
panel around entire periphery
5 to 7 mm
(3/16 to 9/32 in.)
Decoration panel
Sealant
(2) Installation of corner panel.
As shown in the following gure, be sure to install the strap to prevent
falling down.
Strap
Hook
Corner
panel
Hook
(3) Removal of control box cover.
Cover
Slide
Control Box
Screw
(4) Connect the connector.
As shown in the gure below, put the 2 sets of connector with different
colors (red, white) together and make the connection.
Attach the IR receiver wire to connector CN13.
Wire for ap
CN13(IR receiver)
Connector
Tighten with cable tie
(Locally procured)
CAUTION
Connect connectors of the same colors.
(5) Attach control box cover.
Slide
Please tighten the screws.
3.3. ATTACH THE INTAKE GRILLE
Depending on the actual situation, the Open/Close direction for intake
grille can be installed freely.
(1) Tighten 2 grille holding wire.
Grille
holding wire
Screw
Screw
Screw
Intake grille
Intake grille
Screw
Grille Hook
(2) Close intake grille and slide grille hooks.
CAUTION
Install the grille holding wire to the Decoration panel, if it falls, it
may cause injuries.
  • Page 1 1
  • Page 2 2

Fujitsu UTG-UGGB-W Installation guide

Type
Installation guide

Fujitsu UTG-UGGB-W is a cassette-type air conditioner that provides efficient and reliable cooling and heating solutions for various indoor spaces. With its advanced features, it ensures optimal comfort and convenience for users. This air conditioner is designed for easy installation and maintenance, making it a suitable choice for both residential and commercial applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI