1. SAFETY PRECAUTIONS
• BesuretoreadthisManualthoroughlybeforeinstallation.
• ThewarningsandprecautionsindicatedinthisManualcontainimportantinformation
pertainingtoyoursafety.Besuretoobservethem.
• HandthisManual,togetherwiththeOperatingManual,tothecustomer.Requestthe
customertokeepthemonhandforfutureuse,suchasforrelocatingorrepairingtheunit.
WARNING
Indicatesapotentiallyorimminentlyhazardoussituation
which,ifnotavoided,couldresultindeathorseriousinjury.
•Installationofthisproductmustbedonebyexperiencedservicetechniciansorprofes-
sionalinstallersonlyinaccordancewiththismanual.Installationbynon-professionalor
improperinstallationoftheproductmightcauseseriousaccidentssuchasinjury,water
leakage,electricshock,orre.Iftheproductisinstalledindisregardoftheinstructions
inthismanual,itwillvoidthemanufacturer’swarranty.
•Donotturnonthepoweruntilallworkhasbeencompleted.Turningonthepowerbe-
foretheworkiscompletedcancauseseriousaccidentssuchaselectricshockorre.
•Ifrefrigerantleakswhenyouareworking,ventilatethearea.Iftheleakingrefrigerantis
exposedtoadirectame,itmayproduceatoxicgas.
•Installationmustbeperformedinaccordancewithregulations,codes,orstandardsfor
electricalwiringandequipmentineachcountry,region,ortheinstallationplace.
CAUTION
Indicatesapotentiallyhazardoussituationthatmayresultin
minorormoderateinjuryordamagetoproperty.
•Readcarefullyallsafetyinformationwritteninthismanualbeforeyouinstallorusethe
airconditioner.
•Installtheproductbyfollowinglocalcodesandregulationsinforceattheplaceof
installation,andtheinstructionsprovidedbythemanufacturer.
•Thisunitmustbeinstalledbyqualiedpersonnelwithacapacitycerticateforhandling
refrigerantuids.Refertoregulationandlawsinuseoninstallationplace.
•Thisproductispartofasetconstitutinganairconditioner.Theproductmustnotbe
installedaloneorbeinstalledwithadevicenotauthorizedbythemanufacturer.
•Alwaysuseaseparatepowersupplylineprotectedbyacircuitbreakeroperatingonall
wireswithadistancebetweencontactof3mmforthisproduct.
•Toprotectthepersons,earth(ground)theproductcorrectly,andusethepowercable
combinedwithanEarthLeakageCircuitBreaker(ELCB).
•Thisproductisnotexplosionproof,andthereforeshouldnotbeinstalledinanexplo-
siveatmosphere.
•Toavoidgettinganelectricshock,nevertouchtheelectricalcomponentssoonafterthe
powersupplyhasbeenturnedoff.Afterturningoffthepower,alwayswait5minutesor
morebeforeyoutouchtheelectricalcomponents.
•Thisproductcontainsnouser-serviceableparts.Alwaysconsultexperiencedservice
techniciansforrepairing.
•Whenmovingorrelocatingtheairconditioner,consultexperiencedservicetechnicians
fordisconnectionandreinstallationoftheproduct.
•Donottouchthealuminumnsofheatexchangerbuilt-intheindoororoutdoorunitto
avoidpersonalinjurywhenyouinstallormaintaintheunit.
•Donotplaceanyotherelectricalproductsorhouseholdbelongingsundertheproduct.
Condensationdrippingfromtheproductmightgetthemwet,andmaycausedamage
ormalfunctiontotheproperty.
2. ABOUT THE PRODUCT
2.1. Precautions for using R410A refrigerant
Thebasicinstallationworkproceduresarethesameasconventionalrefrigerant(R22)
models.
However,paycarefulattentiontothefollowingpoints:
Sincetheworkingpressureis1.6timeshigherthanthatofconventionalrefrigerant
(R22)models,someofthepipingandinstallationandservicetoolsarespecial.(See
thetablebelow.)
Especially,whenreplacingaconventionalrefrigerant(R22)modelwithanewrefrigerant
R410Amodel,alwaysreplacetheconventionalpipingandflarenutswiththeR410Apiping
andarenuts.
ModelsthatuserefrigerantR410Ahaveadifferentchargingportthreaddiametertopre-
venterroneouschargingwithconventionalrefrigerant(R22)andforsafety.Therefore,
checkbeforehand.[ThechargingportthreaddiameterforR410Ais1/2-20UNF.]
Bemorecarefulthatforeignmatter(oil,water,etc.)doesnotenterthepipingthanwith
refrigerant(R22)models.Also,whenstoringthepiping,securelysealtheopeningby
pinching,taping,etc.
Whenchargingtherefrigerant,takeintoaccounttheslightchangeinthecompositionof
thegasandliquidphases.Andalwayschargefromtheliquidphasewhererefrigerant
compositionisstable.
2.2. Special tools for R410A
Tool name Contents of change
Gauge manifold
Pressureishighandcannotbemeasuredwith a conven-
tional(R22)gauge.Topreventerroneousmixing of other
refrigerants,thediameterofeachporthasbeenchanged.
Itisrecommended thegaugewith seals -0.1to5.3 MPa
(-1to53bar)forhighpressure.
-0.1to3.8MPa(-1to38bar)forlowpressure.
Charge hose
Toincreasepressureresistance,thehosematerialandbase
sizewerechanged.
Vacuum pump
A conventionalvacuumpumpcanbeusedbyinstallinga
vacuumpumpadapter.
Gas leakage detector SpecialgasleakagedetectorforHFCrefrigerantR410A.
Copper pipes
Itisnecessarytouseseamlesscopperpipesanditisdesirablethattheamountofresidual
oilisless than 40mg/10m.Do notusecopperpipeshaving a collapsed,deformedor
discoloredportion(especially on the interior surface). Otherwise, the expansion valueor
capillarytubemaybecomeblockedwithcontaminants.
AsanairconditionerusingR410AincurspressurehigherthanwhenusingR22,itisneces-
sarytochooseadequatematerials.
WARNING
Do not use the existing (for R22) piping and are nuts.
Iftheexistingmaterialsareused,thepressureinsidetherefrigerantcyclewillriseand
causefailure,injury,etc.(UsethespecialR410Amaterials.)
When installing and relocating the air conditioner, do not mix gases other than
the specied refrigerant (R410A) to enter the refrigerant cycle.
Ifairorothergasenterstherefrigerantcycle,thepressureinsidethecyclewillriseto
anabnormallyhighvalueandcausefailure,injury,etc.
AIRCONDITIONER
WallMountedType
INSTALLATION MANUAL
Contents
1. SAFETYPRECAUTIONS.................................................................. 1
2. ABOUTTHEPRODUCT.................................................................... 1
3. GENERALSPECIFICATION............................................................. 2
4. ELECTRICALREQUIREMENT......................................................... 2
5. SELECTINGTHEMOUNTINGPOSITION....................................... 2
6. INSTALLATIONWORK..................................................................... 3
7. ELECTRICALWIRING...................................................................... 5
8. FINISHING......................................................................................... 5
9. FRONTPANELREMOVALANDINSTALLATION............................. 6
10. REMOTECONTROLLERINSTALLATION........................................ 6
11. OPTIONALKITINSTALLATION........................................................ 6
12. FUNCTIONSETTING........................................................................ 9
13. TESTRUN....................................................................................... 10
14. CUSTOMERGUIDANCE................................................................ 10
15. ERRORCODES...............................................................................11
PARTNo.9333005225
EnglishРусский
[Originalinstructions] Forauthorizedservicepersonnelonly.
9333005225_IM_2L.indb 1 10/12/2017 08:48:28
En-2
2.3. For authorized service personnel only
WARNING
•Fortheairconditionertooperatesatisfactorily,installitasoutlinedinthisinstallation
manual.
•Connecttheindoorunitandoutdoorunitwiththeairconditionerpipingandcables
availablefromyourlocaldistributor.Thisinstallationmanualdescribesthecorrect
connectionsusingtheinstallationsetavailablefromyourlocaldistributor.
•Installationworkmustbeperformedinaccordancewithnationalwiringstandardsby
authorizedpersonnelonly.
•Donotturnonthepoweruntilallinstallationworkiscomplete.
CAUTION
Thisinstallationmanualdescribeshowtoinstalltheindoorunitonly.
Toinstalltheoutdoorunit,refertotheinstallationmanualincludedwiththeoutdoorunit.
• Becarefulnottoscratchtheairconditionerwhenhandlingit.
2.4. Accessories
Thefollowinginstallationaccessoriesaresupplied.Usethemasrequired.
Name and Shape
Q’ty
Name and Shape
Q’ty
OperatingManual
1
Clothtape
1
InstallationManual
(Thismanual)
1
SealA
Itisusedwhenthediameterof
gaspipeisØ12.70ormore.
ItisnecessarywhenusingAS14.
1
Wallhookbracket
1
Tappingscrews
(large)
5
Remotecontroller
1
Tappingscrews
(small)
2
Battery
2
Aircleaningfilter
2
Remotecontrollerholder
1
Filterholders
2
Thefollowingitemsarenecessarytoinstallthisairconditioner.(Theitemsarenotinclud-
edwiththeairconditionerandmustbepurchasedseparately.)
Name Q’ty Name Q’ty
Connectionpipeassembly 1 Wallcap 1
Connectioncable(4-conductor)
1 Saddle 1set
Wallpipe 1 Drainhose 1
Decorativetape 1 Tappingscrews 1set
Vinyltape 1 Sealant 1
2.5. Optional parts
Refertoeachinstallationmanualforthemethodofinstallingoptionalparts.
Parts name Model No. Application
WiredRemoteController* UTY-RVNÜM Forairconditioneroperation
WiredRemoteController* UTY-RNNÜM Forairconditioneroperation
SimpleRemoteController* UTY-RSNÜM Forairconditioneroperation
Externalconnectkit* UTY-XWZXZ5 Forcontrolinput/outputport
Communicationkit UTY-XCBXZ2 Fortheinstallationofoptionalparts
*Optionalcommunicationkitisnecessaryfortheinstallation.
3. GENERAL SPECIFICATION
ThisINSTALLATIONMANUALbrieyoutlineswhereandhowtoinstalltheairconditioningsystem.
Pleasereadovertheentire setofinstructionsfortheindoorand outdoor unitsandmakesureall
accessorypartslistedarewiththesystembeforebeginning.
3.1. Type of copper pipe and insulation material
CAUTION
Refertotheinstallationmanualfortheoutdoorunitfordescriptionofallowablepipelength
andheightdifference.
Model
Gas pipe size (thickness)
[mm]
Liquid pipe size (thickness)
[mm]
7,9,12
Ø
9.52(0.8)
Ø
6.35(0.8)
14
Ø
12.70(0.8)
Ø
6.35(0.8)
CAUTION
•Installheatinsulationaroundboththegasandliquidpipes.Failuretodosomay
causewaterleaks.
•
Useheatinsulationwithheatresistanceabove120°C.Reversecyclemodelonly)
•Inaddition,ifthehumiditylevelattheinstallationlocationoftherefrigerantpipingis
expectedtoexceed70%,installheatinsulationaroundtherefrigerantpiping.Ifthe
expectedhumiditylevelis70-80%,useheatinsulationthatis15mmorthickerandif
theexpectedhumidityexceeds80%,useheatinsulationthatis20mmorthicker.
•
I
fheatinsulationisusedthatisnotasthickasspecied,condensationmayformon
thesu
rfaceoftheinsulation.
•Inaddition,useheatinsulationwithheatconductivityof0.045W/(m•K)orless20°C.
3.2. Additional materials required for installation
A.Refrigeration(armored)tape
B.Insulatedstaplesorclampsforconnectingwire(Seeyourlocalelectricalcodes.)
C.Putty
D.Refrigerationlubricant
E.Clampsorsaddlestosecurerefrigerantpiping
4. ELECTRICAL REQUIREMENT
Theindoorunitispoweredfromtheoutdoorunit.Donotpowerindoorunitfromseparate
powersource.
WARNING
Refertolocalcodesforacceptablecabletype.
Cable
Cable size
Remarks
Connectioncable
Type60245IEC57
(1.5mm
2
)
3cable+Ground,1.5Ø230V
CableLength:Limitvoltagedroptolessthan2%.Increasecablegaugeifvoltagedropis
2%ormore.
5. SELECTING THE MOUNTING POSITION
Decidethemountingpositionwiththecustomerasfollows:
5.1. Indoor unit
(1) Installtheindoorunitlevelonastrongwallwhichisnotsubjecttovibration.
(2) Theinletandoutletportsshouldnotbeobstructed:theairshouldbeabletoblowall
overtheroom.
(3)
Installtheunitadedicatedelectricalbranchcircuit.
(4)
Donotinstalltheunitwhereitwillbeexposedtodirectsunlight.
(5)
Installtheunitwhereconnectiontotheoutdoorunitiseasy.
(6) Installtheunitwherethedrainpipecanbeeasilyinstalled.
(7) Takeservicing,etc.intoconsiderationandleavethespacesshownin[6.1.Installation
dimensions].Alsoinstalltheunitwheretheltercanberemoved.
Correctinitialinstallationlocationisimportantbecauseitisdifculttomoveunitafteritis
installed.
WARNING
Selectinstallationlocationsthatcanproperlysupporttheweightoftheindoorunit.
Installtheunitssecurelysothattheydonottoppleorfall.
CAUTION
Donotinstalltheunitinthefollowingareas:
•Areawithhighsaltcontent,suchasattheseaside.Itwilldeterioratemetalparts,caus-
ingthepartstofailortheunittoleakwater.
•Arealledwithmineraloilorcontainingalargeamountofsplashedoilorsteam,such
asakitchen.
Itwilldeteriorateplasticparts,causingthepartstofailortheunittoleakwater.
•Areathatgeneratessubstancesthatadverselyaffecttheequipment,suchassulfuric
gas,chlorinegas,acid,oralkali.
Itwillcausethecopperpipesandbrazedjointstocorrode,whichcancauserefrigerant
leakage.
•Areathatcancausecombustiblegastoleak,containssuspendedcarbonbersor
ammabledust,orvolatileinammablessuchaspaintthinnerorgasoline.
•Ifgasleaksandsettlesaroundtheunit,itcancauseare.
•Areawhereanimalsmayurinateontheunitorammoniamaybegenerated.
•Donotusetheunitforspecialpurposes,suchasstoringfood,raisinganimals,grow-
ingplants,orpreservingprecisiondevicesorartobjects.
•Itcandegradethequalityofthepreservedorstoredobjects.
•Donotinstallwherethereisthedangerofcombustiblegasleakage.
9333005225_IM_2L.indb 2 10/12/2017 08:48:34
En-3
•Donotinstalltheunitnearasourceofheat,steam,orammablegas.
•Installtheunitwheredrainagedoesnotcauseanytrouble.
•Installtheindoorunit,outdoorunit,powersupplycable,connectioncable,andremote
controlcableatleast1mawayfromatelevisionorradioreceivers.Thepurposeof
thisistopreventTVreceptioninterferenceorradionoise.
•(Eveniftheyareinstalledmorethan1mapart,youcouldstillreceivenoiseunder
somesignalconditions.)
•Ifchildrenunder10yearsoldmayapproachtheunit,takepreventivemeasuresso
thattheycannotreachtheunit.
•Installtheindoorunitonthewallwheretheheightfromtheoorsmorethan1800mm.
6. INSTALLATION WORK
6.1. Installation dimensions
Outlineoftheindoorunit
Unit:mm
Wallhookbracket
144or
more
1,500
ormore
1,800ormore
(52or
more)
(25or
more)
86or
more
63or
more
(45or
more)
6.2. Indoor unit piping direction
Thepipingcanbeconnectedinthe
6
directionsindicatedinthefollowing.
Whenthepipingisconnectedindirection
2
,
3
,
4
or
5
,
cutalongthepipinggroovein
thesideofthefrontcoverwithahacksaw.
2
Right
outlet
5
Left
outlet
6
Leftrear
outlet
3
Bottomoutlet
1
Rearoutlet
4
Leftbottomoutlet
(Rear)
6.3.
Cutting the hole in the wall for the connecting piping
(1) Cuta65mmdiameterholeinthewallatthepositionshowninthefollowing.
(2) Cuttheholesothattheoutsideendislower(5to10mm)thantheinsideend.
(3) Alwaysalignthecenterofthewallhole.Ifmisaligned,waterleakagewilloccur.
(4)
Cutthewallpipetomatchthewallthickness,stickitintothewallcap,fastenthecapwith
vinyltape,andstickthepipethroughthehole.
(5) Forleftpipingandrightpiping,cuttheholealittlelowersothatdrainwaterwillow
freely.
Wall
Fastenwith
vinyltape*
65mmdia.hole
65mmdia.hole
Wallhookbracket
Centermark
Centermark
Wallcap*
Wallpipe*
(Inside)
(Outside)
5to10mmlow
*Locallypurchased
WARNING
Ifthewallpipeisnotused,thecableinterconnectingtheindoorunit(s)andoutdoorunit
maytouchmetalandcauseelectricdischarge.
6.4. Installing the wall hook bracket
•Removethewallhookbracketfromtheindoorunit.(Remove2screws).
(1)Installthewallhookbracketsothatitiscorrectlypositionedhorizontallyandvertically.
Ifthewallhookbracketistitled,waterwilldriptotheoor.
(2)
Installthewallhookbracketsothatitisstrongenoughtosupporttheweightoftheunit.
•Fasten thewallhook brackettothe wallwith5 or morescrewsthrough theholes
neartheouteredgeofthebracket.
•Checkthatthereisnorattleatthewallhookbracket.
Wallhookbracket
Tappingscrews(large,accessories)
CAUTION
Installthewallhookbracketbothhorizontallyandverticallyaligned.Misalignedinstalla-
tionmaycausewaterleakage.
6.5. Forming the drain hose and pipe
[Rear piping, Right piping, Bottom piping]
•Installtheindoorunitpipinginthedirectionofthewallholeandbind thedrainhose
andpipetogetherwithvinyltape.
•Installthepipingsothatthedrainhoseisatthebottom.
•Wrapthepipesoftheindoorunitthatarevisiblefromtheoutsidewithdecorativetape.
[For Left rear piping, Left piping]
Interchangethedraincapandthedrainhose.
CAUTION
Insertdrainhoseanddraincapsecurely.Drainshouldslopedowntoavoidwaterleakage.
•When inserting,besurenottoattachanymaterialbesideswater.Ifanyother
materialisattached,itwillcausedeteriorationandwaterleakage.
•Afterremovingdrainhose,besurenottoforgetmountingdraincap.
•Besuretoxthedrainhosewithtapetothebottomofpiping.
•Preventdrainwaterfreezingunderlowtemperatureenvironment.
Wheninstallingindoorunit’sdrainhoseoutdoors,necessarymeasureforfrost
protectionshouldbetakentopreventdrainwaterfreezing.
Underlowtemperatureenvironment(whenoutdoortemperatureunder0°C),after
coolingoperationisexecuted,waterinthedrainhosecouldbefrozen.Oncedrainwater
isfrozen,thedrainhosewillbeblockedandwaterleakagemayresultattheindoorunit.
Installation method of Drain cap
Useahexagonalwrench4mmatoppositesidetoinsert
thedraincap,tillthedraincapcontactsthetipofdrain
cock.
Rightpiping
Bottompiping
Bindwithvinyltape
Refrigerantpipes(top)
Rearpiping
Indoorunitdrainhose(bottom)
Forleftoutletpiping,
cutoffthepiping
outletcuttinggroove
withahacksaw.
Indoorunit
drainhose
Draincap
Removethedraincapbypull-
ingattheprojectionattheend
ofthecapwithpliers,etc.
Nogap
Hexagonal
wrench
Drain
cock
Draincap
9333005225_IM_2L.indb 3 10/12/2017 08:48:41
En-4
Removal method of drain hose
Removethescrewattheleftofdrain
hoseandpulloutdrainhose.
Installation method of drain hose
Verticallyinsertthedrainhosetowardthe
inside,sothatthedrainxture(white)canac
-
curatelyalign with the screw hole around the
draincock.
Afterinserting and before replacing,please
reinstallandxtheremovedscrews.
• Pleaseholdaroundthejointofthedrainhoseduringworking.
•
Asthescrewisinside,besuretousescrewdrivertreatedwithmagnet.
Screw
Drainfixture
Drainhose
Screwhole
Draincock
Drainhose
Screw
Drainfixture
•
Forleftpipingandleftrearpiping,alignthemarksonthewallhookbracketandshapethe
connectionpipe.
•Bendtheconnectionpipingatabendradiusof70mmormoreandinstallnomorethan
35mmfromthewall.
•
Afterpassingtheindoorpipinganddrainhosethroughthewallhole,hangtheindooruniton
thehooksatthetopandbottomofthewallhookbracket.
[Installing the indoor unit]
• Hangtheindoorunitfromthehooksatthetopofthewallhookbracket.
• Insertthespacer,etc.betweentheindoorunitandthewallhookbracketandseparate
thebottomoftheindoorunitfromthewall.
Indoorunit
Wallhookbracket
(Spacer)
Connectionpipe(6.35mmdia.)
Alignthemarks
Indoorunit
Connectionpipe(9.52or12.7mmdia.)
Tophooks
Bottomhooks
Wallhookbracket
BendR70mmwith
apipebender
Afterhookingtheindoorunittothetophook,hookthettingsoftheindoorunittothe2
bottomhookswhileloweringtheunitandpushingitagainstthewall.
6.6. Flare connection (Pipe connection)
CAUTION
Tightenthearenutswithatorquewrenchusingthespeciedtighteningmethod.Oth-
erwise,thearenutscouldbreakafteraprolongedperiod,causingrefrigeranttoleak
andgeneratehazardousgasiftherefrigerantcomesintocontactwithaame.
6.6.1. Flaring
UsespecialpipecutterandaretoolexclusiveforR410A.
(1) Cuttheconnectionpipetothenecessarylengthwithapipecutter.
(2) Holdthepipedownwardsothatcuttingswillnotenterthepipeandremoveanyburrs.
(3)
Inserttheare nut (always use the are nutattachedtothe indoor unit(s) and outdoor
unitrespectively)ontothepipeandperformtheareprocessingwithaaretool.Usethe
specialR410Aaretool,ortheconventionalaretool.Leakageofrefrigerantmayresultif
otherarenutsareused.
(4) Protectthepipes bypinchingthem orwithtape topreventdust, dirt, orwaterfrom
enteringthepipes.
Die
A
Pipe
B
L
Checkif[L]isflareduniformly
andisnotcrackedorscratched.
Pipe outside diameter
[mm (in.)]
Dimension A [mm]
Dimension B
[mm]
Flare tool for R410A, clutch type
6.35(1/4)
0to0.5
9.1
9.52(3/8) 13.2
12.70(1/2) 16.6
15.88(5/8) 19.7
19.05(3/4) 24.0
WhenusingconventionalaretoolstoareR410Apipes,thedimensionAshouldbeap-
proximately0.5mmmorethanindicatedinthetable(foraringwithR410Aaretools)to
achievethespeciedaring.UseathicknessgaugetomeasurethedimensionA.
Widthacross
flats
Pipe outside diameter
[mm (in.)]
Width across flats of Flare
nut [mm]
6.35(1/4) 17
9.52(3/8) 22
12.70(1/2) 26
15.88(5/8) 29
19.05(3/4) 36
6.6.2. Bending pipes
• Ifpipesareshapedbyhand,becarefulnottocollapsethem.
• Donotbendthepipesinananglemorethan90°.
• Whenpipesarerepeatedlybendorstretched,thematerialwillharden,makingitdifcult
tobendorstretchthemanymore.
• Donotbendorstretchthepipesmorethan3times.
CAUTION
•Topreventbreakingofthepipe,avoidsharpbends.
•Ifthepipeisbentrepeatedlyatthesameplace,itwillbreak.
6.6.3. Pipe connection
CAUTION
•Besuretoinstallthepipeagainsttheportontheindoorunitcorrectly.Ifthecenter-
ingis improper,the are nut cannot tighten smoothly. If theare nut is forcedto
turn,thethreadswillbedamaged.
•Donotremovethearenutfromtheindoorunitpipeuntilimmediatelybeforecon-
nectingtheconnectionpipe.
•Holdthetorquewrenchatitsgrip,keepingitintherightanglewiththepipe,inorder
totightenthearenutcorrectly.
Tightenthe are nuts with a torque wrench using the specied tightening method.
Otherwise,thearenutscouldbreakafteraprolongedperiod,causingrefrigerantto
leakandgeneratehazardousgasiftherefrigerantcomesintocontactwithaame.
CAUTION
•Connectthepipingsothatthecontrolboxcovercaneasilyberemovedforservic-
ingwhennecessary.
•Inordertopreventwaterfromleakingintothecontrolbox,makesurethatthepip-
ingiswellinsulated.
Whentheflarenutistightenedproperlybyyourhand,holdthebodysidecouplingwitha
wrench,thentightenwithatorquewrench.(Seethetablebelowfortheflarenuttightening
torques.)
Tightenwithtwowrenches.
Holdingwrench
Flarenut
Connectionpipe
Torquewrench
Indoorunitpipe
(Bodyside)
Flarenut[mm(in.)] Tighteningtorque[N·m(kgf·cm)]
6.35(1/4)dia. 16to18(160to180)
9.52(3/8)dia. 32to42(320to420)
12.70(1/2)dia. 49to61(490to610)
15.88(5/8)dia. 63to75(630to750)
19.05(3/4)dia. 90to110(900to1,100)
9333005225_IM_2L.indb 4 10/12/2017 08:48:43
En-5
7. ELECTRICAL WIRING
7.1. Wiring system diagram
WARNING
•Everywiremustbeconnectedrmly.
•Nowireshouldbeallowedtotouchrefrigeranttubing,thecompressororanymov-
ingpart.
•Loosewiringmaycausetheterminaltooverheatorresultinunitmalfunction.Are
hazardmayalsoexist.Therefore,besureallwiringistightlyconnected.
•Connectwirestothematchingnumbersofterminals.
Groundingline
Type60245IEC57
(Inter-unit)
OUTDOORUNIT
Pleaseconnectitto
thespeciedterminal.
INDOORUNIT
TERMINAL
Powerline
Controlline
7.2. Indoor unit wiring
1.Removethewirecover.(Remove1screw.)
2.Removethecableclamp.
3.Ringterminalsconnecttotheconnectioncable.
4.Connecttheringterminalsfullyintotheterminalblock.
5.Fastentheconnectioncablewithacableclamp.
Wirecover
Wirecover
Screw
Screw
Screw
Screw
Insertthewirecovertabintothesquarehole
oftheindoorunitandfastenwithascrew.
Connectioncable
60mm
40mm
Cableclamp
Cableclamp
Earth(Ground)wire
7.3. How to connect wiring to the terminals
Cautionwhenwiringcable
Whenstrippingofftheinsulationofaleadwire,alwaysuseaspecialtoolsuchasawire
stripper.Ifthereisnospecialtoolavailable,carefullystriptheinsulationwithaknifeetc.
(1) Usering terminalswith insulatingsleevesasshowninthegureto connect to the
terminalblock.
(2) Securelyclamptheringterminalstothewiresbyusinganappropriatetoolsothatthe
wiresdonotcomeloose.
Strip:10mm
Ringterminal
Sleeve
(3) Usethespeciedwires,connectthemsecurely,andfastenthemsothatthereisno
stressplacedontheterminals.
(4) Useanappropriatescrewdrivertotightentheterminalscrews.Donotuseascrew-
driverthatistoosmall,otherwise,thescrewheadsmaybedamagedandpreventthe
screwsfrombeingproperlytightened.
(5) Donottightentheterminalscrewstoomuch,otherwise,thescrewsmaybreak.
Screwwithspecialwasher
Wire
Ringterminal
Terminalblocks
Wire
Screwwithspecialwasher
Ringterminal
(6) Seethefollowingtablefortheterminalscrewtighteningtorques.
Tighteningtorque[N·m(kgf·cm)]
M4screw 1.2to1.8(12to18)
CAUTION
•Matchtheterminalblocknumbersandconnectioncablecolorswiththoseofthe
outdoorunit.
Erroneouswiringmaycauseburningoftheelectricparts.
•Connecttheconnectioncablesrmlytotheterminalblock.Imperfectinstallationmay
causeare.
•Alwaysfastentheoutsidecoveringoftheconnectioncablewiththecableclamp.(If
theinsulatorischafed,electricdischargemayoccur.)
•Alwaysconnectthegroundwire.
•Donotusetheearthscrewoftheindoorunitfortheconnectionotherthanaspecied
outdoorunit.
8. FINISHING
(1) Insulatebetweenpipes.
• Insulatesuctionanddischargepipesseparately.
• Forrear,right,andbottompiping,overlaptheconnectionpipeheatinsulationand
indoorunitpipeheatinsulationandbindthemwithvinyltapesothatthereisnogap.
• Forleftandleftrearpiping,butttheconnectionpipeheatinsulationandindoorunit
pipeheatinsulationtogetherandbindthemwithandvinyltapesothatthereisnogap.
• Forleftandleftrearpiping,wraptheareawhichaccommodatestherearpiping
housingsectionwithclothtape.
• Forleftandleftrearpiping,bindtheconnectioncabletothetopofthepipewith
vinyltape.
• Forleftandleftrearpiping,bundlethepipinganddrainhosetogetherbywrapping
themwithclothtapeovertherangewithinwhichtheytintotherearpiping
housingsection.
(2) Temporarilyfastentheconnectioncablealongtheconnectionpipewithvinyltape.
(Wraptoabout1/3thewidthofthetapefromthebottomofthepipesothatwater
doesnotenter.)
(3) Fastentheconnectionpipetotheoutsidewallwithasaddle,etc.
(4) Fillthegapbetweentheoutsidewallpipeholeandthepipewithsealersothatrain
waterandwindcannotblowin.
(5) Fastenthedrainhosetotheoutsidewall,etc.
*Locallypurchased
Pipe
Saddle*
Outsidewallcap*
Sealerputty*
(Outdoors)
Wall
Overlaptheinsulation
Vinyltape*
Wrapwithclothtape
Clothtape(accessory)
Drainhose*
Connectioncable
Pipe
Drainhose
Checkthefollowing:
GOOD
Drainhose
Saddle
Liftedup Wave Endinwater
Drainhose Connectionpipe
Wallpipe Connectioncable
Left piping For connection from the left rear
Pipe
Connectionpipe
(heatinsulation)
Indoorunitpipe
(heatinsulation)
PROHIBITED
Bindthepipestogether
sothatthereisnogap.
SealAisusedwhenthediameter
ofgaspipeisØ12.70ormore.
Buttconnectionpipe(heat
insulation)againsttheindoor
unitpipe(heatinsulation)and
wrapwithsealAsothatthere
isnogap.
9333005225_IM_2L.indb 5 10/12/2017 08:48:45
En-6
9. FRONT PANEL REMOVAL AND INSTALLATION
Intake grille removal Intake grille installation
b
a
Opentheintake
grille.Whilegently
pressingtheleft
andrightmounting
shaftsoftheintake
grilleoutward“a”,
removetheintake
grilleindirectionof
thearrow“b”.
c
Whileholdingthe
grillehorizontal,set
theleftandright
mountingshaftsinto
thepillowblocksat
thetopofthepanel
“c”.
Tolatcheachshaft
properly,insertthe
shaftuntilitsnaps.
Press4placeson
theintakegrilleto
closeitcompletely.
9.1. Front panel removal
(1) Removeintakegrille(Refertothe“Intakegrilleremoval”.)
(2) Removewirecover.
(3) Remove6screws.
Screws(6places)
4screws(Donotremove.)
Wirecover
(4) Pullthefrontpaneltothefront,thenraiseittoremove.
Frontpanel
9.2. Front panel installation
(1) First,t thelower part of the frontpanel, and insert top andbottom hooks. (3 top
sides,2center)
Indoorunit
Frontpanel
Latches(2places)
Centerhooks
(2places)
Tophooks
(3places)
Topholes(6places)
(2) Attachthe6screws.
(3) Attachthewirecover.
(4) Attachtheintakegrille.
CAUTION
InstalltheFrontpanelandIntakegrillesecurely.Ifinstallationisimperfect,theFront
panelorIntakegrillemayfalloffandcauseinjury.
10. REMOTE CONTROLLER INSTALLATION
CAUTION
•Checkthattheindoorunitcorrectlyreceivesthesignalfromtheremotecontroller,
theninstalltheremotecontrollerholder.
•Selecttheremotecontrollerholderselectionsitebypayingcarefulattentiontothe
following:
Avoidplacesindirectsunlight.
Selectaplacethatwillnotbeaffectedbytheheatfromastove,etc.
10.1. Remote controller holder installation
Installtheremotecontrolleramaximumdistanceof7mfromtheremotecontrollerre-
ceiver.However,wheninstallingtheremotecontroller,checkthatitoperatescorrectly.
I
nstalltheremotecontrollerholdertoawall,pillar,etc.withthetappingscrew.
Remote controller
holder xing
Remote
controllerholder
Tappingscrew
(small)
Remote controller
mounting
Remote
controller
2
Push
1
Set
10.2. Remote controller custom setting
Usethefollowingstepstoselectthecustomcodeoftheremotecontroller.(Notethatthe
airconditionercannotreceiveasignaliftheairconditionerhasnotbeensetforthematch-
ingcustomcode.)
(1) Pressthe“START/STOP(
)”buttonuntilonlythe
clockisdisplayedontheremotecontrollerdisplay.
(2) Pressthe“MODE”buttonforatleast5secondstodis-
playthecurrentcustomcode(initiallysettoA).
(3) Pressthe“TEMP.”(
/ )buttonstochangethecus-
tomcodebetween
A↔B↔C↔D
.
Matchthecodeonthedisplaytotheairconditioner
customcode.
(4) Pressthe“MODE”buttonagaintoreturntotheclock
display.Thecustomcodewillbechanged.
•Ifnobuttonsarepressedwithin30secondsafterthecustomcodeisdisplayed,the
systemreturnstotheoriginalclockdisplay.Inthiscase,startagainfromstep1.
•TheairconditionercustomcodeissettoApriortoshipment.
11. OPTIONAL KIT INSTALLATION
Thisairconditionercanbeconnectedwiththefollowingoptionalkits.
• Wiredremotecontroller
• Simpleremotecontroller
• Externalconnectkit
CAUTION
•Beforeinstalling,besuretodisconnectallpowersupply.
•Don’ttouchtheheatexchanger.
•Duringinstallingorremovingoperation,besurenottohavewirecaughtbypartsor
drawithard.Oritmayresulttroublestotheair-conditioner.
•Avoidplaceindirectsunlight.
•Selectplacethatwillnotbeaffectedbytheheatfromastove,etc.
•Beforesettinguptheoptionalkit,pleaseconrmwhetherair-conditionercanreceive
thesignal.
•Donotconnectthewiredremotecontrollertotheterminalforpowersupply.
•Whenconnectingthewiredremotecontrollerwiththeindoorunit,usetheconnecting
cable(suppliedwithwiredremotecontrollerorsimpleremotecontroller).
•Recommendedcablelengthofwiredremotecontrolleris10m.Makesuretoinsulate
theconnectingpartwhenextendingthecable.
• Whenyouusewiredremotecontroller,somefunctionsmaynotbeused.
•
Donotconnectpowersupplywiththeterminal.
INDOORUNIT
PCB
TERMINAL
9333005225_IM_2L.indb 6 10/12/2017 08:48:51
En-7
11.3.
Installing communication box
11.3.1. Removing intake grille
( Refer to “9.1. Front panel removal” )
11.3.2. Removing control box
(1) Removethescrews(x4).(Usethesamescrewswheninstalling.)
(2) Pullthecontrolboxcovertowardsyouandremove.
(1)
(1)
(2)
(1)
(1)
(3) Removetheconnectors(x4).
• Removeandpulloffthelockatthesideoftheconnectorinsertionpart.
CAUTION
•Becarefulnottodamagethepartsontheboard.
Otherwise,itwillcausemalfunction.
Connectornumber:CN5*
Connectornumber:CN4*
Connectornumber:CN3*
Connectornumber:CN7*
*:Symbolindicatingthelocationprintedontheboard
(4) Removethewiresfromthethreefixtures.(Seethefigurebelow)
• LeavethethickgreenwireinfixtureCandremovetherestofthewires.
CAUTION
•Donotpullthewiresforcibly.Youmaydamagethem.
FixtureA
Before After
FixtureB
FixtureC
FixtureC
(5) Whilepullingthecontrolboxtowardsyou,removeintherightdirection.
• Donotremovethethermistor.
• Donotdamagetheterminalsontheremovedwires.
Thermistor
Controlbox
Terminals
11.1. Remote controller cable modication
(1) Useatooltocutofftheterminalontheendoftheremotecontrollercable,andthen
removetheinsulationfromthecutendofthecable.
(2) Connecttheremotecontrollercableandconnectingcable.
(suppliedwithwiredremotecontroller)
Important:Besuretosolderwirestoconnect.Besuretoinsulatetheconnection
betweenthewires.
Connectingcable
White
Red
White
Red
Black
Black
Insulated
connection
Remote
controllercable
Remote
controllercable
20mm
11.2. Installing wired remote controller terminal /
external connect kit terminal (sold separately)
(1) Removethescrewonthecontrolboxasshownonthetoprightofthefigurebelow.
(2) Releasebothbottomclaspsatthesidesinthedirectionofthearrowascircledin
thebottomleftofthefigurebelow.Pullandremovethecover.
(2)
(1)
Cover
(3) Connectthewiredremotecontrollerterminal/externalconnectkitterminal(sold
separately)tothespecifiedterminalontheboardasshownbelow.Pleaseconnect
totheconnectorwithnecessaryfunctionaccordingtotheactualusage.
(4) Afterconnectingeachterminal,threadthecablesthroughthenotchascircledon
thebottomrightofthefigurebelow.
(3) Controlinput(Operation/
StoporForcedstop)
connector
:CNA01(White)*
(3) Wiredremotecontroller
connector
:CNC01(White)*
*:Symbolindicatingthelocationprintedontheboard
(3) ErrorStatusoutput
connector
:CNB02(Black)*
(3) Operationstatus
outputconnector
:CNB01(White)*
(4)
(5)Installthecontrolboxcoverasshownbelow.
(Alignthecoverwiththeupperandlowerrightcornersasindicatedbythetriangular
symbolsonthefigure.
Inserttheclaspsonthecoverintobothsidesatthebottomofthetwodotted
circles.)
• Wheninstallingthecontrolboxcover,makesurethatthecablesarenotcaughtas
showninthedetailview.
(6)Installonescrew.
(7)Screwtheearthwireofwiredremotecontrollerasshowninthefigure.(AUSTRALIA
modelonly).
(7)
(5)
(5)(6)Cover
Detailview
9333005225_IM_2L.indb 7 10/12/2017 08:48:53
En-8
Controlbox
(5)
11.3.3. Installing communication box
(1) Installthecommunicationboxonthemainunitandsecureitwiththeprovided
screwatthelocationshownbelow.
ViewA(Detailview)
Screw
Motorcover
ViewA(Detailview)
(2) Usetheholeonthemotorcoverandsecurethewirefromthecommunicationbox
withtheprovidedcabletie(accessoryforoption).
(Seethefigurebelow)
Cabletie
Cutawaythetipof
thecabletie.
Hole
11.3.4. Installing control box
(1) Setthecontrolboxtowardthebottomsothatittouchesthemotorcoverfromthe
right.
Inserttheprotrudingpartofthemain
unitonthexture(1location)into
thecontrolbox.
Controlbox
• Theinstallationmethodofthecontrolboxisdifferentforeachdestinationcountry.
(Wheninstalling,reusethescrewthatwasremovedin11.3.2. Removing control
box.)
(2) Securethecontrolboxwithascrew.(Usealongscrew.)
(3)
(2)
(3) Fastentheearthwiresoftheheatexchangertogetherasshownintheleftfigure
above.(Useashortscrewhere.)
(4) Hitchthewiresontothefixturesasshownintheovalcirclesbelow.Thenconnect
theconnectorsinthesquarestotheterminalsrespectively.
(Eachterminalshouldformapairwithaconnector.)
CAUTION
•Ensurethattheconnectorisproperlyinserted.
Otherwise,itmayresultinerroneousoperation.
•Becarefulnottodamagethepartsontheboard.
Otherwise,itwillcausemalfunction.
(4)
(5) Fastentheearthwire(green)inthecommunicationboxtogetherwiththeearthwire
(green)ontheboardofthecontrolboxasshowninthefollowingfigure.
(5)
(6) Installthecoverofthecontrolboxontotheinnersideoftheribasfollows.
CAUTION
•Donotcutortuckthewireswiththeelectricalcomponentboxcover.
Anelectricshockmayoccurifthewiresaredamaged.
9333005225_IM_2L.indb 8 10/12/2017 08:49:01
En-9
(7) Tightenwithscrewstopreventthecoverofthecontrolboxfromfallingoff.
(Wheninstalling,reusethescrewsthatwasremovedin13.3.2.Removingcontrol
box.)
(7)
(7)
(6)
(8) Pasteprotectseals(2locations)topreventthewiresfromstickingout.
(8)
11.3.5. Installing front panel
( Refer to “9.2. Front panel installation” )
12. FUNCTION SETTING
Performthe“FUNCTIONSETTING”accordingtotheinstallationconditionsusingthe
remotecontroller.
CAUTION
•ConrmwhetherthewiringworkforOutdoorunithasbeennished.
•Conrmthatthecoverfortheelectricalenclosureontheoutdoorunitisinplace.
• Thisprocedurechangesthefunctionsettingsusedtocontroltheindoorunitaccording
totheinstallationconditions.Incorrectsettingscancausetheindoorunittomalfunction.
• Afterthepoweristurnedon,performthe“FUNCTIONSETTING”accordingtothe
installationconditionsusingtheremotecontroller.
• Thesettingsmaybeselectedbetweenthefollowingtwo:FunctionNumberorSetting
Value.
• Settingswillnotbechangedifinvalidnumbersorsettingvaluesareselected.
• Refertotheinstallationmanualenclosedwiththeremotecontrollerwhenthewired
remotecontroller(option)isused.
Entering the Function Setting Mode
WhilepressingthePOWERFULbuttonandSETTEMP.( )simultaneously,pressthe
RESETbuttontoenterthefunctionsettingmode.
STEP 1
Selecting the Remote Controller Custom Code
UsethefollowingstepstoselectthecustomcodeoftheRemoteController.(Notethatthe
airconditionercannotreceiveasignaliftheairconditionerhasnotbeensetforthematch-
ingcustomcode.)
Thecustomcodesthataresetthroughthisprocessareapplicableonlytothesignalsin
theFUNCTIONSETTING.Fordetailsonhowtosetthecustomcodesthroughthenormal
process,referto“Remotecontrollercustomcode”.
(1) Press SETTEMP. (
/ ) button to change the custom
codebetween
A↔B↔C↔D
.Matchthecodeonthe
displaytotheairconditionercustomcode.(initiallysettoA)
(Ifthecustomcodedoesnotneedtobeselected,pressthe
10°CHEATbuttonandproceedtoSTEP2.)
(2) PresstheMODEbuttonandcheckthattheindoorunitcan
receivesignalsatthedisplayedcustomcode.
(3) Pressthe10°C HEAT button to accept the customcode,
andproceedtoSTEP2.
TheairconditionercustomcodeissettoApriortoshipment.
STEP 2
Selecting the Function Number and Setting Value
(1) PresstheSETTEMP.( / )buttonstoselectthe
functionnumber.(Pressthe10
°C
HEATbuttonto
switchbetweentheleftandrightdigits.)
(2) Pressthe
POWERFUL
buttontoproceedtosetting
value.(Press the
POWERFUL
button again to return
tothefunctionnumberselection.)
(3) PresstheSETTEMP.(
/ )buttonstoselectthe
settingvalue.(Pressthe10
°C
HEATbuttontoswitch
betweentheleftandrightdigits.)
(4) PresstheMODEbutton,andSTART/STOPbutton,in
theorderlistedtoconrmthesettings.
(5) PresstheRESETbuttontocancelthefunctionset-
tingmode.
(6) AftercompletingtheFunctionSetting,besuretodis-
connectthepowersupplyandthenreconnectit.
CAUTION
Afterdisconnectingthepowersupply,wait30secondsormorebeforereconnectingit.
TheFunctionSettingwillnotbecomeactiveunlessthepowersupplyisdisconnected
andthenreconnected.
Filter sign
Selectappropriateintervalsfordisplayingtheltersignontheindoorunitaccordingtothe
estimatedamountofdustintheairoftheroom.
Iftheindicationisnotrequired,select“Noindication”(03).
(♦...Factorysetting)
Function
Number
Setting
Value
Setting Description
11
00 Standard(400hours)
01 Longinterval(1,000hours)
02 Shortinterval(200hours)
03 Noindication
Room temperature sensor control for cooling
Dependingontheinstalledenvironment,correctionoftheroomtemperaturesensormay
berequired.
Selecttheappropriatecontrolsettingaccordingtotheinstalledenvironment.
(♦...Factorysetting)
Function
Number
Setting
Value
Setting Description
30
00 Standard
01 Slightlylowercontrol
02 Lowercontrol
03 Highercontrol
Room temperature sensor control for heating
Dependingontheinstalledenvironment,correctionoftheroomtemperaturesensormay
berequired.
Selecttheappropriatecontrolsettingaccordingtotheinstalledenvironment.
(♦...Factorysetting)
Function
Number
Setting
Value
Setting Description
31
00 Standard
01 Lowercontrol
02 Slightlyhighercontrol
03 Highercontrol
Auto restart
Enableordisableautomaticrestartafterapowerinterruption.
(♦...Factorysetting)
Function
Number
Setting
Value
Setting Description
40
00 Enable
01 Disable
*Autorestartisanemergencyfunctionsuchasforpoweroutageetc.Donotattemptto
usethisfunctioninnormaloperation.Besuretooperatetheunitbyremotecontrolleror
externaldevice.
Function Number
Setting
Value
9333005225_IM_2L.indb 9 10/12/2017 08:49:03
En-10
Room temperature sensor switching
(Onlyforwiredremotecontroller)
WhenusingtheWiredremotecontrollertemperaturesensor,changethesettingto“Both”(01).
(♦...Factorysetting)
Function
Number
Setting
Value
Setting Description
42
00 Indoorunit
01 Both
00:Sensorontheindoorunitisactive.
01:Sensorsonbothindoorunitandwiredremotecontrollerareactive.
*
Remotecontrollersensormustbeturnedonbyusingtheremotecontroller.
Remote controller custom code
(Onlyforwirelessremotecontroller)
Theindoorunitcustomcodecanbechanged.Selecttheappropriatecustomcode.
(♦...Factorysetting)
Function
Number
Setting
Value
Setting Description
44
00 A
01 B
02 C
03 D
External input control
“Operation/Stop”modeor“Forcedstop”modecanbeselected.
(♦...Factorysetting)
Function
Number
Setting
Value
Setting Description
46
00 Operation/Stopmode
01 (Settingprohibited)
02 Forcedstopmode
Room temperature sensor switching (Aux.)
Tousethetemperaturesensoronthewiredremotecontrolleronly,changethesettingto“Wired
remotecontroller”(01).Thisfunctionwillonlyworkifthefunctionsetting42issetat“Both”(01)
(♦...Factorysetting)
Function
Number
Setting
Value
Setting Description
48
00 Both
01 Wiredremotecontroller
Indoor unit fan control for energy saving for cooling
Enablesordisablesthepower-savingfunctionbycontrollingtheindoorunitfanrotationwhen
theoutdoorunitisstoppedduringcoolingoperation.
(♦...Factorysetting)
Function
Number
Setting
Value
Setting description
49
00 Disable
01 Enable
00:Whentheoutdoorunitisstopped,theindoorunitfanoperatescontinuouslyfollowing
thesettingontheremotecontroller.
01:Whentheoutdoorunitisstopped,theindoorunitfanoperatesintermittentlyatavery
lowspeed.
Setting record
Recordanychangestothesettingsinthefollowingtable.
Setting Description Setting Value
Filtersign
Roomtemperaturesensorcontrolforcooling
Roomtemperaturesensorcontrolforheating
Autorestart
Roomtemperaturesensorswitching
Remotecontrollercustomcode
Externalinputcontrol
Roomtemperaturesensorswitching(Aux.)
Indoorunitfancontrolforenergysavingforcooling
AftercompletingtheFunction Setting,besure todisconnectthe powersupplyand then
reconnectit.
13. TEST RUN
Check items
(1) Isoperationofeachbuttonontheremotecontrollernormal?
(2) Doeseachlamplightnormally?
(3) Doairowdirectionlouversoperatenormally?
(4) Isthedrainnormal?
(5) Donothaveanabnormalnoiseandvibrationduringoperation?
Donotoperatetheairconditionerintestrunforalongtime.
[Operation method]
Fortheoperationmethod,refertotheoperatingmanual.
Theoutdoorunit,maynotoperate,dependingontheroomtemperature.Inthis
case,keeponpressingtheMANUALAUTObuttonoftheindoorunitformorethan
10seconds.Theoperationindicatorlampandtimerindicatorlampwillbegintoash
simultaneouslyduringcoolingtestrun.Then,heatingtestrunwillbegininaboutthree
minuteswhenHEATisselectedbytheremotecontroloperation.(Pleasefollowthe
operatingmanualforremotecontroloperation.)
Toendtestoperation,presstheremotecontrollerSTART/STOPbutton.
(Whentheairconditionerisrunningbypressingthetestrunbutton,theOPERATION
LampandTIMERLampwillsimultaneouslyashslowly.)
[Using the wired remote controller] (Option)
Fortheoperationmethod,refertotheoperatingmanual.
(1) Stoptheairconditioneroperation.
(2) Pressthemastercontrolbuttonandthefancontrolbuttonsimultaneouslyfor2
secondsormoretostartthetestrun.
Testrundisplay
(3) Pressthestart/stopbuttontostopthetestrun.
14. CUSTOMER GUIDANCE
Explainthefollowingtothecustomerinaccordancewiththeoperatingmanual:
(1)Startingandstoppingmethod,operationswitching,temperatureadjustment,timer,air-
owswitching,andotherremotecontrolleroperations.
(2)Airlterremovalandcleaning,andhowtousetheairlouvers.
(3)Givetheoperatingmanualtothecustomer.
9333005225_IM_2L.indb 10 10/12/2017 08:49:03
En-11
15. ERROR CODES
Ifyouuseawirelessremotecontroller,thelamponthephotodetectorunitwilloutputerror
codesbywayofblinkingpatterns.Ifyouuseawiredremotecontroller,errorcodeswillap-
pearontheremotecontroldisplay.Seethelampblinkingpatternsanderrorcodesinthe
table.Anerrordisplayisdisplayedonlyduringoperation.
Error display
Error code Description
OPERATION
lamp
(green)
TIMER
lamp
(orange)
ECONOMY
lamp
(green)
(1)
(1)
Serialcommunicationerror
(1)
(2)
•Wiredremotecontroller
communicationerror
•Serverroomcontrol
communicationerror
(1)
(5)
Checkrununfinished
(1)
(6)
PeripheralunittransmissionPCB
connectionerror
(1)
(8)
Externalcommunicationerror
(2)
(1)
UnitnumberorRefrigerantcircuit
addresssettingerror
[SimultaneousMulti]
(2)
(2)
Indoorunitcapacityerror
(2)
(3)
Combinationerror
(2)
(4)
•Connectionunitnumbererror
(indoorsecondaryunit)
[SimultaneousMulti]
•Connectionunitnumbererror
(indoorunitorbranchbox)
[FlexibleMulti]
(2)
(6)
Addresssettingerrorinwired
remotecontrollersystem
(2)
(7)
Primaryunit,secondaryunitset-
uperror[SimultaneousMulti]
(3)
(2)
IndoorunitPCBmodel
informationerror
(3)
(5)
Manualautoswitcherror
(4)
(1)
Roomtemp.sensorerror
(4)
(2)
IndoorunitHeatEx.Middletemp.
sensorerror
(5)
(1)
Indoorunitfanmotor1error
(Mainfan)
(5)
(3)
Drainpumperror
(5)
(4)
ElectricaircleanerreverseVDD
error
(5)
(5)
Filterseterror
(5)
(7)
Dampererror
(5)
(8)
Intakegrilleerror
(5)
(9)
Indoorunitfanmotor2error
(Leftsidefan)
(5)
(10)
Indoorunitfanmotor3error
(Rightsidefan)
(5)
(15)
Indooruniterror
(6)
(2)
OutdoorunitmainPCBmodel
informationerroror
communicationerror
(6)
(3)
Invertererror
(6)
(4)
Activefiltererror,PFCcircuiterror
(6)
(5)
TripterminalLerror
(6)
(8)
Outdoorunitrushcurrentlimiting
resistertemp.riseerror
Error display
Error code Description
OPERATION
lamp
(green)
TIMER
lamp
(orange)
ECONOMY
lamp
(green)
(6)
(10)
DisplayPCBmicrocomputers
communicationerror
(7)
(1)
Dischargetemp.sensorerror
(7)
(2)
Compressortemp.sensorerror
(7)
(3)
OutdoorunitHeatEx.liquidtemp.
sensorerror
(7)
(4)
Outdoortemp.sensorerror
(7)
(5)
SuctionGastemp.sensorerror
(7)
(6)
•2-wayvalvetemp.sensorerror
•3-wayvalvetemp.sensorerror
(7)
(7)
Heatsinktemp.sensorerror
(8)
(2)
•Sub-coolHeatEx.gasinlet
temp.sensorerror
•Sub-coolHeatEx.gasoutlet
temp.sensorerror
(8)
(3)
Liquidpipetemp.sensorerror
(8)
(4)
Currentsensorerror
(8)
(6)
•Dischargepressuresensorerror
•Suctionpressuresensorerror
•Highpressureswitcherror
(9)
(4)
Tripdetection
(9)
(5)
Compressorrotorposition
detectionerror
(9)
(7)
Outdoorunitfanmotorerror
(9)
(9)
4-wayvalveerror
(10)
(1)
Dischargetemp.error
(10)
(3)
Compressortemp.error
(10)
(4)
Highpressureerror
(10)
(5)
Lowpressureerror
(13)
(2)
Branchboxeserror
[FlexibleMulti]
Displaymode
:0.5sON/0.5sOFF
:0.1sON/0.1sOFF
():Numberofflashing
[Troubleshooting with the indoor unit display]
OPERATIONindicator(green)
TIMERindicator(orange)
ECONOMYindicator(green)
[Troubleshooting with the Wired Remote Controller Display (Option)]
Ifan error occurs, the followingdisplaywill be shown. (“Er” willappear in the set room
temperaturedisplay.)
Errorcode
9333005225_IM_2L.indb 11 10/12/2017 08:49:12
9333005225_IM_2L.indb 12 10/12/2017 08:49:12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Fujitsu ASYG14LMCE-R Installation guide

Category
Split-system air conditioners
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI