Robinair 16600 User manual

Category
Measuring, testing & control
Type
User manual

This manual is also suitable for

Operating Manual — English
Refrigerant Leak Detector ..........................1
Manual de Operación — Spanish
Detector de Fugas de Refrigerante ............7
Manuel d’utilisation — French
Détecteur de fuites de frigorigène ..............13
Bedienungsanleitung — German
Kältemittel-Lecksuchegerät ........................19
Manuale dell’operatore — Italian
Sensore di perdite di refrigerante ...............25
16600
16600 Refrigerant Leak Detector
1
Introduction ................................................................................ 1
Controls and Indicators............................................................... 2
Features....................................................................................... 3
Operation .................................................................................... 4
Maintenance ............................................................................... 5
Replacement Parts ...................................................................... 6
Specifications ............................................................................. 6
Table of Contents
Introduction
The 16600 is an electronic leak detector used to detect refrigerant leaks in air
conditioning and refrigeration systems. It features a sensitivity selection switch
which allows it to be used with CFCs and HCFCs at one setting and HFCs at
the other. The unit is able to detect leaks smaller than 1/2 ounce per year.
Other features include audible and visual leak indicators, a volume control, a
threshold balancing control and a 16" gooseneck probe, which holds its
position for one-handed operations. When the unit is not being used, the probe
wraps into a retaining clip on the back of the case.
(2N08) Refrigerant Leak Detection Equipment Design Certified
by Underwriters Laboratories, Inc.
®
to meet SAE J-1627 (1993)
for R-12 and R-134a refrigerants.
1© 2000 Robinair, SPX Corporation
2
Description
Controls and Indicators
ON/OFF and BALANCE—The same control turns on the unit and gives you
infinite control for eliminating background contamination to find leaks fast.
VOLUME—Allows you to adjust the audible leak signal to the appropriate
volume for the working conditions.
SENSITIVITY LEVEL—The 16600 can be used for a wide range of
refrigerants, but because of different properties of the refrigerant, the correct
sensitivity level should be selected. Here are guidelines:
Level 1—HFCs such as R-134a, HP 62, AC 9000, AZ 20, and AZ 50
(refrigerant blends made up primarily of HFCs)
Level 2—CFCs and HCFCs such as R-12, R-22, R-500, and R-502
(refrigerant blends made up primarily of CFCs and HCFCs).
If you are not sure which refrigerant is in the system, start with Level 2 and
change to Level 1 if you have trouble pinpointing the leak after balancing the
leak detector several times.
VISUAL LEAK INDICATOR—The LEDs light up to show increasing levels
of concentration. One LED means a minimal amount of refrigerant is reaching
the sensor; when all LEDs are lit, there is a sizeable leak or concentration. The
LEDs illuminate in sequence from bottom to top.
LOW BATTERY INDICATOR—If only the top LED is lighted, the batteries
are low and should be replaced.
AUDIBLE LEAK INDICATOR—The normal operating sound is a steady
ticking. As you move the probe closer to a leak, the tone will change to a faster
ticking sound and then to an alarm sound (the loudness of this indicator can be
adjusted using the volume control).
16600 Refrigerant Leak Detector
3
WARNING
Wear safety goggles when working with refrigerants.
Contact with refrigerants can cause eye injury.
One-Hand Operation
The 16" gooseneck probe
holds its position, so you
can operate the detector
with one hand.
Audible and Visual Leak
Indicators—An alarm increases
in frequency as the tip nears a
high concentration of refrigerant.
LEDs light up to indicate a leak
and refrigerant concentration.
Volume Control—Adjust
the audible signal to the
volume that’s right for the
background noise in the
shop or at the job site.
Threshold Balancing
Control—Gives you infinite
control for eliminating
background contamination,
so you can zero in on the
leak site.
Battery Door—Located
on the back side of the
handle, the door is easy
to remove to change
batteries.
Sensing Selection Switch
Slide the switch to Level 1 or
Level 2, depending on the
type of refrigerant in the
system.
Features
1© 2000 Robinair, SPX Corporation
4
The first time you use the 16600 leak detector, install the batteries before
turning on the unit. Four “AA” alkaline batteries are included (see
“Maintenance Instructions”).
1. Remove the gooseneck probe from the retaining clip on the back of the leak
detector case.
2. Turn the ON/OFF switch to ON.
3. Select the sensitivity level by sliding the switch to either the “1” setting or
the “2” setting.
4. Adjust the balance. Turn the BALANCE control up to a loud alarm sound,
then turn it down until you hear a slow, steady ticking.
5. Begin searching for the leak. The recommended scan rate is two (2) inches
per second with the sensing tip as close as possible to the area being
searched. Run the probe under tubing and check carefully around bends,
fittings, and other typical leak points.
TIP: Refrigerant is heavier than air, so check for leaks at the top of the system
first, working your way toward the bottom. In strong wind conditions, you may
need to shield the area before searching for leaks.
6. To pinpoint a leak, you may need to adjust the balance. When you are near a
concentration of refrigerant, the alarm tone will sound. Keep the probe in
the same position and turn the balance control down until you hear the
ticking sound. Then continue searching for the leak. You may need to
balance the unit several times if there is a large leak and refrigerant has
accumulated.
7. If you find more than one leak, or if you suspect more than one, repair the
larger leak(s) first so pinpointing the smaller leak is easier.
Operation
16600 Refrigerant Leak Detector
5
Maintenance
Cleaning/Replacing the Sensing
Tip
The sensing tip is the most critical component of the leak detector.
Periodically it may become clogged with dirt, grease, and oil. If the tip looks
dirty, and you have difficulty pinpointing a leak or experience constant false
alarms, the tip probably needs to be cleaned or replaced.
To Clean the Tip:
1. Turn the ON/OFF switch to OFF.
2. Unscrew the tip from the gooseneck probe.
3. The tip can be cleaned in most vaporizable solvents, such as denatured
alcohol. We recommend using a solvent, but if this is not possible, wash
the tip in warm, soapy water. Rinse thoroughly with clear water and allow
to air dry completely before reinstalling the tip on the probe.
IMPORTANT! Allow adequate time for the tip to air-dry before using
the leak detector. Moisture in the tip can trigger false alarms.
Be sure your hands are clean and dry. Be careful not to contaminate
the tip with perspiration, grease, hand cleaners, etc.
Maintenance
To Change the Tip:
An extra tip comes with the unit. You can also buy replacement tips. One extra
tip stores in a special slot inside the battery compartment. Follow the
instructions in “INSTALLING/REPLACING BATTERIES” to open the battery
compartment.
1. Turn the ON/OFF switch to OFF.
2. Unscrew the tip from the gooseneck probe.
3. Thread the new tip onto the probe until it’s finger-tight. Do not overtighten.
4. When the leak detector is not in use, wrap the gooseneck probe into the
retaining clip to protect it.
1© 2000 Robinair, SPX Corporation
6
Specifications
Power Supply .............................................................. 4 “AA” alkaline batteries
Sensitivity ..................................................................... Less than
1
/2 oz. per year
Battery Life................................................................... Approximately 25 hours
Dimensions ........................................................................8
1
/2"L x 3
1
/4"W x 2"D
............................................................................... (21.59 cm x 8.26 cm x 5 cm)
Probe Length ...................................................................... 16 inches (40.6 CM)
Weight ................................................................. 1.14 lbs. (.52 kg) with batteries
Installing/Replacing Batteries
Your unit uses four (4) “AA” alkaline batteries. The batteries should be replaced
if the top LED (beside the words LOW BATTERY) lights up when the unit is
first turned on. The battery compartment is located on the back of the case.
1. Turn the ON/OFF switch to OFF.
2. Remove the screw holding the battery compartment door. If you are
replacing batteries, remove the old batteries.
3. Place the new batteries in the battery compartment, following polarity
indication.
4. Replace the battery compartment door, and secure the door with the screw.
Replacement Parts
16503 Replacement Sensing Tip
16604 Battery Compartment Door
Maintenance
123264 (Rev. B, 10/15/03) 16600 Refrigerant Leak Detector © SPX Corporation
Visit our web site at
www.robinair.com
or
call our Toll-Free Technical Support Line at:
1-800-822-5561
NATIONWIDE NETWORK OF AUTHORIZED
SERVICE CENTERS
If your unit needs replacement parts, contact the service center
in your area. For help in locating a service center, call the Toll-
Free Technical Support Line or visit our web site.
in the co
ntinental U.S. and Canada.
In all other locations, call your local distributor.
The 16600 Leak Detector is covered by Robinairs exclusive No Hassle
Over-the-Counter Exchange Warranty for a period of one year from the
date of sale. For details, see your local distributor or visit our web site.
SPX Corporation
655 Eisenhower Drive
Owatonna, MN 55060-0995 USA
Technical Services: 1-800-822-5561
Fax: 1-800-822-7805
Customer Service: 1-800-533-6127
Fax: 1-800-322-2890
Web Site: www.robinair. com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Robinair 16600 User manual

Category
Measuring, testing & control
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI