INSTALLATION INSTRUCTIONS FOR P84167, P84500, PB3030027,
P84166 AND PB3042227 WITH UNO AND ARIA BI-FOLD HANDLES
Twin Bolt Lock Overall Dimensions:
Figure 1. Twin Bolt Lock Dimensions
Figure 2. Face Routing
Routing Details:
Detail not required for
Non Locking configuration
58.1 (Low Profile Aria and Uno)
Ø16
Ø10
Ø3.3
R5
38
58
26
43
Threaded shoot bolts shown fully extended
199.7
43
21.5
273
190
M5 holes for possible side fixing to extrusion
32 (max unthrown)
24 (max thrown)
17.75 (max)
TWIN BOLT LOCK 18MM THROW -
BI-FOLD DOORS
ASSA ABLOY New Zealand Limited, 6 Armstrong Road, Albany,
North Shore City 0632, New Zealand, Tel 09 415 8031, Fax 0800 478 297
2-02/08NZ
Page 2 of 3
Part #: 077226
INSTALLATION INSTRUCTIONS FOR P84167, P84500, PB3030027,
P84166 AND PB3042227 WITH UNO AND ARIA BI-FOLD HANDLES
1. Cut the rods to length allowing for a lock throw of 18mm.
Note: Allowance must also be made for the clearance between
the door and frame, the D-tip length of 44mm and the multi
point rod threaded 14mm into the lock.
2. Press the D-tips onto the end of the multi point rod. Crimp
the rods onto the D-tip to ensure a solid fit (a crimping tool
– P84042 – is available for this task).
3. Screw the rods to the lock, tightening the lock nuts against the
throw bolts (see fig 4). Locking nuts only need to be used when
D-tips are retained by a round rod guide (i.e not needed with
D-shaped guide) to prevent the rod from unwinding.
4. Select the packers to be used and clip this onto the lock body.
Note: The remaining packer can be clipped onto the back of the
lock to hold it for easier fixing in the section.
5. Mount the lock assembly onto the door stile checking lock
function, D-tip protrusion and D-tip orientation. Fix the handle
and lock assembly to the extrusion using the M5 fixing screws.
Note: The 8mm square drive bar should protrude through the
entire lock for adequate performance.
6. For Locking Version: Screw the CYL4 lock housing onto the
lock body using the M4 fixing screw (see Fig 6 for the packer
selection guide). Assemble the lock barrel and housing cover
using the retainer wafer of the lock to hold the assembly
together.
Important Note: The cylinder should not be used externally.
7. Screw the lock escutcheon in place.
Note on Rods: The vertical locking rods supplied cater for a
maximum door height of 2300mm. For taller applications
a multi-point extension kit is available which caters for a
maximum door height of 3300mm, the part number for the
multi-point kit is P84017, one kit required per twin bolt lock
body.
Warning: When tightening lock nut use a spanner to support
the lock bolt. This will prevent any damage to the lock.
See Fig 4.
Fig 4. Rod Assembly with Lock Nut
Assembly Details:
For assembly through the end of the extrusion:
Short bolt
Lock nut
Multi Point rod
Twin bolt lock
Spanners
D-Tip Stainless Steel
(2 of)
Multi-point Rod
(Cut to Correct Length)
Twin Bolt Lock
Lock Nut
(2 of, if required)
Packer
Cyl4 Lock & Components
Low Profile
Uno Escutcheon
Low Profile
Aria Escutcheon
M4 CSK TT Escutcheon
fixing screws
M5 CSK TT Handle
fixing screws
Uno Bi-fold Handle
Aria Bi-fold Handle
M4 CSK TT Cylinder
fixing screws
Fig 3. Lock Assembly
TWIN BOLT LOCK 18MM THROW -
BI-FOLD DOORS
ASSA ABLOY New Zealand Limited, 6 Armstrong Road, Albany,
North Shore City 0632, New Zealand, Tel 09 415 8031, Fax 0800 478 297
2-02/08NZ
Page 3 of 3
Part #: 077226
INSTALLATION INSTRUCTIONS FOR P84167, P84500, PB3030027,
P84166 AND PB3042227 WITH UNO AND ARIA BI-FOLD HANDLES
The length of the M5 fixing screws is critical to the performance of
the lock.
If the screw is too short the lock will not be held correctly.
If the screw is too long the lock may bind and not operate.
Screw Length = E + X + P + (4.5 ± 0.5) mm – refer opposite
Fig 7. Packing system for locking cylinder
In the situation where the lock is assembled into composite (wood and
aluminium) sections, the locking cylinder assembly may require packing to
ensure it sits proud of the door, see Fig 7.
Screw Length Formula:
Sections Non Locking - Use: Locking with Low Profile Lock Escutcheon - Use:
Aluminium
• 38mm internal extrusion width
• 1.6mm extrusion thickness
• M5 x 17mm Screws
• 6.25mm Packer (interior side)
• 6.25mm x 2 Packer (exterior side)
• M5 x 26mm Screws
• M4 x 10mm Screw
• 14.8mm Packer (interior side)
• 5mm Packer (exterior side)
Aluminium
• 38mm internal extrusion width
• 3.6mm extrusion thickness
• M5 x 26 Screws
• 14.8mm Packer (interior side)
• 5mm Packer (exterior side)
• M5 x 26mm Screws
• M4 x 10mm Screw
• 14.8mm Packer (interior side)
• 5mm Packer (exterior side)
This guide shows the M5 screws required for fixing the lock and the M4 screws for fixing the locking cylinder (if locking version), and the
packers that should be used in each situation. For all other section configurations use the formula above.
Screw and Packer Selection Guide:
Cylinder Packing:
Fig 5. Top view of Components in Folding Panel Section
Twin Bolt Lock
Packed Cyl Adapter
Cyl Packer
Cyl Housing
Cyl Housing Cover
M4 CSK Taptite Fixing Screw
Lock Cylinder
Packer (Thickness P)
Extrusion (Thickness X)
Handle Escutcheon
(Thickness E)
E
X
P
Fig 6. Screw Length Formula
  • Page 1 1
  • Page 2 2
  • Page 3 3

Assa Abloy INTERLOCK P84167 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI