COOL-1

Sentinel COOL-1 User manual

  • Hello! I am an AI chatbot trained to assist you with the Sentinel COOL-1 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the power requirement for the COOL-1?
    What is the maximum capacity of the COOL-1?
    What is the temperature range that the COOL-1 can control?
    What is the temperature deadband for the COOL-1?
    What is the life expectancy of the COOL-1?
    What is the warranty period for the COOL-1?
    How do I install the COOL-1?
    How does the COOL-1 work?
    What is the purpose of the red indicator light on the side of the COOL-1?
    Can the COOL-1 be used as a high-temperature shutdown for HID lights?
Specifications COOL-1
Amps / Volts requirements 15 amps @ 120 volts
Min / Max temperature settings 50 to 115° F
Temperature Deadband 5 degrees F
Life Expectancy > 10 years
Maximum capacity 15-amps / 3/4 HP
Sentinel products are distributed by:
GPS / Global Product Solutions LLC.
www.growgps.com
All Sentinel Timers and
controllers offer a
3-year warranty.
Ask your retailer for
details.
Instruction Manual
COOL-1
*HIGH-TEMP SHUTDOWN OPTION
*This COOL-1 has been pre-configured to shut off you HID
lights if the temperature inside the growing area exceeds the
temperature you select on the COOL-1.
Any device that operates on 120 volts and is 15-amps or less
can be plugged into the COOL-1.
120 volt receptacle
CONTENTS
A quick look at the COOL-1
Installation of the COOL-1
Operating the COOL-1
Hi-temp Shutdown
Specifications
A quick look at the COOL-1…
Red indicator verifies when the
receptacle has power
Set temperature anywhere
from 51’F to 115’F
Enclosure plugs
directly into wall
receptacle
Remote bulb thermostat can
be placed 30” from the unit.
Installing the COOL-1
1) The unit requires a 120 volt power supply. The device that will
be controlled must be 15-amps or less.
2) The COOL-1 is plugged directly into a wall outlet. The 6/32
screw provided with the unit can be used to secure the
COOL-1 to the wall outlet. (remove existing screw first)
3) Connect the device you are controlling into the receptacle on
the front face of the unit.
4) Turn the dial on the COOL-1 to the desired maximum
temperature setting. When the temperature rises to the setting,
what ever is connected to the COOL-1 receptacle will be
turned off until the temperature drops by 5’F. Once the
temperature drops to the lower level, the device connected is
re-activated.
Operating the COOL-1
Once the COOL-1 is plugged in and has power, the temperature
probe will read the air temperature. When the air temperature gets
above the setpoint, the device connected to the COOL-1 will be
DE-activated.
Since the COOL-1 has a 5 degree F deadband, when the
temperature goes 5 degrees below the setpoint, the COOL-1 will
turn ON the device connected to it.
The RED indicator light on the side of the unit turns ON when
the receptacle on the front of the unit is powered. When the light
is ON, the device connected to the COOL-1 will be operating.
Hi-temp shutdown
THIS COOL-1 is already configured to be a hi-temp
shutdown for HID lights.
It can also act as a heating thermostat. When the temperature in
the area rises, the device connected is turned OFF.
/