Dynasty Spas 9919-100418-B User manual

Type
User manual

This manual is also suitable for

Quick Reference Card
The Quick Reference Card provides a quick overview of your spa's main
functions and the operations accessible with your digital control pad.
Press Pump 1 to turn Pump 1 on at low speed.
Press a second time to turn pump to high speed.
Press a third time to turn pump off. When at high
speed, a built-in timer turns pump off after 20 min-
utes and when at low speed after 2 hours, unless
manually deactivated first.
The "Pump 1" indicator lights up
when Pump 1 is on at high speed.
It flashes when Pump 1 is on at low
speed.
Starting Pump 1:
Press and hold Light key for 5 seconds to display
water temperature in either Fahrenheit (˚F) or
Celsius (˚C). If a power-up occurs, system re-
turns to default setting (˚F).
Temperature display unit:
Press Econo key to switch from Normal mode to
Economy mode. In Economy mode, system main-
tains temperature at the desired Set Point during
filter cycles only. Set Point is 20˚F (11˚C) below
the Normal mode Set Point for the rest of the
time. In Economy mode, the display will toggle
between the current water temperature and the
"Econ" message.
Economy mode:
SC-MP-DY1 / Dual-Pump System
Turning the light on:
Press Pump 2 to turn Pump 2 on. Press a second
time to turn Pump 2 off. A built-in timer automati-
cally turns pump off after 20 minutes, unless pump
has been manually deactivated.
The "Pump 2" indicator lights up
when Pump 2 is on.
Starting Pump 2:
Use Up or Down arrow keys to regulate water
temperature. The temperature setting will be
displayed for 5 seconds to confirm your new
selection.
The "Set Point" indicator displays the
desired temperature, NOT the current
water temperature!
Water temperature can be adjusted by 1˚ in-
crements from 59 to 104˚F (15 to 40˚C).
Setting water temperature:
When water temperature is 1˚F (0.5˚C) lower
than the Set Point, the heater will automatically
turn on until water temperature reaches Set Point
plus 1˚F (0.5˚C).
The "Heater" indicator lights up when
the heater is on. It flashes when there
is a request for more heat but the heater
has not yet started.
N.B.: If your system is configured in Low Current Mode,
the heater will not start if a pump is on at high speed.
Automatic water heater start:
Neptune Series Spas feature an easy-to-change selection of nine
different LED color/display settings. To activate the LED lights,
press the "LIGHT" button on the topside panel one time. To
advance to the next color/display setting, press the "LIGHT" button
twice in a row. The LED's will go off with the first press, then back
on in the next setting with the second press. If the LED's remain off
for more than 5 seconds, the color/display sequence will reset and
start back at the beginning the next time the "LIGHT" button is
pressed. The color/display sequence is:
Setting #1 LED's light up and slowly cycle throught all six color.
The slow cycle then restarts at the beginning and repeats.
Setting#2 LED's light up and remain on in Aqua.
Setting#3 LED's light up and remain on in Purple.
Setting#4 LED's light up and remain on in Blue.
Setting#5 LED's light up and remain on in Gold.
Setting#6 LED's light up and remain on in Green.
Setting#7 LED's light up and remain on in Red.
Setting#8 LED's light up for 2 sec, flash off, then flash on in the
next color, until all six colors have been displayed. The flashing
cycle then restarts at the beginning and repeats.
Setting#9 LED's flash on/off quickly, for a strobe light effect.
The LED lights will automatically turn themselves off after 2 hours
in any one setting.
PROGRAMMING FILTER CYCLE DURAT ION
The system automatically performs two filter cycles per day, at 12-hour intervals. During a filter cycle:
Pump 2 runs for one minute, then
Pump 1 runs at low speed for the programmed number of hours
The "Filter Cycle" indicator lights up when the filter cycle is on.
To set filter cycle duration:
3 flashing dots are displayed.
A problem has been detected.
Do not enter the water! Check and open water valves.
Clean filter if necessary. Check water level. Add water
if needed.
Shut power off and power your spa up again to reset the
system.
Call your dealer or service supplier if problem persists.
Water temperature is flashing. Water temperature in the spa has reached 112 ˚F (44˚C).
Do not enter the water! Allow water to cool down. The
system will reset automatically when water temperature
reaches 109 ˚F (43˚C).
Call your dealer or service supplier if problem persists.
The display is flashing. A power failure has occurred.
Press any key to reset the system, then reprogram all
desired parameters.
TROUBLESHOOTING
Pumps have started up for one
minute on several occasions and
"Filter Cycle" indicator is flashing.
Not a bug but a feature!
Our Smart Winter Mode protects your spa from the
cold by automatically turning pumps on for one minute
several times a day to prevent water from freezing in pipes.
N.B.: After a power failure, the filter cycle duration
will return to its de fault value (2 hours). In this case,
the first filter cycle will start one minute after power
has been restored.
Press and hold Filter key
until the display shows " xx",
representing the currently
set filter cycle duration in
hours.
When the desired setting is dis-
played, press Filter key to confirm.
A filter cycle starts immediately.
Use Up or Down arrow keys
to change setting.
0 = no filtration
12 = continuous filtration
E
Q
U
I
P
P
E
D
W
I
T
H
G
E
C
K
O
'
S
E
X
C
L
U
S
I
V
E
Smart
Winter
Mode
TM
9919-100418-B
The filter cycle is suspended if the water temperature
raises more than 2 ˚F (1˚C) above Set Point or if spa
is in use (pumps and light started manually). The "Filte r"
icon will blink (on 0.5 second, off 0.5 second, on 0.5
second, off 1.5 seconds).