HoMedics UV CLEAN, SANC050 Instruction book

  • Hello! I am an AI chatbot trained to assist you with the HoMedics UV CLEAN Instruction book. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
www.homedics.com/register
Your valuable input regarding this
product will help us create the
products you will want in the future.
PLEASE TAKE A
MOMENT NOW
REGISTER YOUR PRODUCT AT:
INSTRUCTION MANUAL AND WARRANTY INFORMATION
1-YEAR LIMITED WARRANTY
SAN-C
SANITIZER CASE
EN
TABLE OF CONTENTS
English ...................................................................................................................................... 4
Français ..................................................................................................................................12
Español ..................................................................................................................................22
Deutsch ..................................................................................................................................32
Italiano ...................................................................................................................................42
IMPORTANT SAFETY INSTRUCTIONS
WHEN USING ELECTRICAL PRODUCTS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING.
DANGER
TO REDUCE THE RISK OF ELECTRIC SHOCK:
DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
DO NOT place in or drop into water or other liquids.
WARNING –
TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS:
THIS PRODUCT IS PROVIDED WITH A SAFETY MECHANISM TO REDUCE
THE RISK OF EXPOSURE TO ULTRAVIOLET RADIATION. DO NOT DEFEAT
ITS PURPOSE. USE THE DEVICE WITH THE UNIT AND CLASP COMPLETELY
CLOSED.
DO NOT attempt to look directly at the UV LEDs while the unit is on. UV
light can be irritating to the eyes and skin.
DO NOT attempt to modify this product. It has been designed to contain
UV exposure.
SAVE THESE INSTRUCTIONS
CAUTION –
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.
DO NOT expose the device to fire or excessive temperature. Exposure to fire
or temperatures above 265°F may cause explosion.
Follow all operating instructions and do not use the device outside of the
temperature range specified. Operating improperly or at temperatures
outside of the specified range may damage the product and increase the
risk of fire. Product operating range: 32°F - 104°F/0°C - 40°C.
EN
UNIQUE FEATURES & SPECIFICATIONS
UV-C TECHNOLOGY
Ultraviolet (UV) light is a short wavelength light invisible to the human eye.
It kills up to 99.9% of bacteria and viruses. There are cold-, heat-, and drug-
resistant germs. There are no common UV-C resistant germs.
REVOLUTIONARY LED TECHNOLOGY
Environmentally friendly, and is mercury and chemical free.
PROPRIETARY FUNCTIONALITY
Through research, simulations, and third-party lab testing, we’ve derived
the maximum sanitization ecacy between light dispersion angle and UV-C
intensity. Our thermoform design ensures optimal ultraviolet light exposure
across your device for maximum ecacy.
FITS MOST PHONES
Designed and built to accommodate phones, including most larger models,
like the iPhone 8+ and Google Pixel 3a XL.
ULTRAFAST SANITIZATION
Sanitizes in just 90 seconds per side.
SAFE
Safety lock ensures device can only be used when it is fully closed and the
clasp closure is positioned magnetically in the on position.
ANTIBACTERIAL COATING
Prevents spread of germs from one side of device to the other.
POWER
MAGNETIC
CLASP LOCK
USB POWER
PORT
SANITIZER CASE
EN
POWERING YOUR PHONE SANITIZER
To function, your sanitizer must be plugged into a power source. Connect the
included USB cable to a power socket, portable power bank, laptop, etc. while
product is in use.
LED INDICATORS
Alternating
red and blue
flashing for 3
seconds
UV-C LED malfunction. Contact Consumer Relations.
Flashing red for
3 seconds
Case not closed properly, check magnetic clasp.
Flashing blue
In sanitizing mode.
HOW TO USE
1. Use provided USB cable to plug the sanitizer into a wall outlet or other
USB charger.
2. Open up (Fig. 1).
3. Place phone or other items inside (Fig. 2).
4. Close and secure clasp lock (Fig. 3).
5. Press power button (Fig. 4).
6. Blue light stops flashing when sanitizing is complete.
7. Undo clasp lock.
8. Flip phone or other items and repeat to sanitize both sides.
NOTE: The case will not work if it is not completely closed and the clasp
situated magnetically in the on position.
Fig. 1 Fig. 2
Fig. 3 Fig. 4
EN
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Doesn’t work
Not connected to
power source
Case not closed and
clasp not placed in the
magnetic on position
Plug into power
source using the
included USB
cable
Ensure case
is completely
closed and align
the clasp in the
magnetic on
position
Indicator flashes red
and blue
UV-C LEDs are
damaged
Do not attempt
to use again.
Contact
HoMedics
Consumer
Relations
FAQS
HOW DO I KNOW IF THE CASE IS WORKING?
The power icon will flash blue indicating the UV-C LEDs are on and sanitizing.
LED INDICATOR KEEPS FLASHING RED. WHAT DOES IT MEAN?
Flashing red means the case is not properly closed. Please make sure to
completely close the case, and ensure the clasp is situated magnetically in the
on position.
IS THIS SAFE FOR MY PHONE?
Yes, UV CLEAN uses UV-C light, not water or chemicals. UV-C light kills germs
and is completely safe for your phone. Safety features ensure no UV-C light can
escape and anything placed inside the case is not harmed.
CAN IT CLEAN ANYTHING ELSE?
UV CLEAN was designed primarily for phones, however you can use it to
sanitize just about anything. If it’s inside, UV CLEAN will sanitize it. For more
information about how UV-C works, please visit www.homedics.com.
FAQS (CONT.)
CAN I RUN MULTIPLE CONSECUTIVE CLEANING CYCLES?
Yes, you can! Though the first cycle will have cleaned your device up to 99.9%,
there is no harm to your device to run another cycle if you wish.
CARE AND MAINTENANCE
Clean product with soft, damp cloth.
DO NOT use harsh chemicals.

EN
FCC AND IC STATEMENTS
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.
NOTE: HoMedics is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void
the user authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules and CAN ICES-3 (B)/
NMB-3 (B). These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
RSS INFORMATION
This device complies with RSS-210 of the IC Rules. Operation is subject to the
following 2 conditions: (1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation. This Class B digital apparatus complies with
Canadian ICES-003.
SUPPLIER’S DECLARATION OF CONFORMITY
Product Description: UV CLEAN SANITIZER CASE
Model Number: SAN-C050
Trade Name: HoMedics
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including interference
that may cause undesired operation.
U.S. Contact Information
Company: HoMedics LLC
Address: 3000 N Pontiac Trail, Commerce Township, MI 48390
8:30am-7:00pm EST Monday-Friday 1-800-466-3342

HoMedics sells its products with the intent that they are free of defects in manufacture and
workmanship for a period of 1 year from the date of original purchase, except as noted below.
HoMedics warrants that its products will be free of defects in material and workmanship under
normal use and service. This warranty extends only to consumers and does not extend to Retailers.
To obtain warranty service on your HoMedics product, contact a Consumer Relations representative
for assistance. Please make sure to have the model number of the product available.
HoMedics does not authorize anyone, including but not limited to Retailers, the subsequent
consumer purchaser of the product from a Retailer, or remote purchasers, to obligate HoMedics
in any way beyond the terms set forth herein. This warranty does not cover damage caused by
misuse or abuse; accident; the attachment of any unauthorized accessory; alteration to the product;
improper installation; unauthorized repairs or modifications; improper use of electrical/power supply;
loss of power; dropped product; malfunction or damage of an operating part from failure to provide
manufacturer’s recommended maintenance; transportation damage; theft; neglect; vandalism; or
environmental conditions; loss of use during the period the product is at a repair facility or otherwise
awaiting parts or repair; or any other conditions whatsoever that are beyond the control of HoMedics.
This warranty is effective only if the product is purchased and operated in the country in which the
product is purchased. A product that requires modifications or adoption to enable it to operate
in any other country than the country for which it was designed, manufactured, approved, and/or
authorized, or repair of products damaged by these modifications is not covered under this warranty.
THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE
SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY
WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL HAVE NO
LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES. IN NO EVENT SHALL
THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR PARTS
THAT ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE WARRANTY.
NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE MATERIALS ARE NOT
AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU
OF REPAIR OR REPLACEMENT.
This warranty does not extend to the purchase of opened, used, repaired, repackaged, and/or
resealed products, including but not limited to sale of such products on internet auction sites and/
or sales of such products by surplus or bulk resellers. Any and all warranties or guarantees shall
immediately cease and terminate as to any products or parts thereof that are repaired, replaced,
altered, or modified, without the prior express and written consent of HoMedics.
This warranty provides you with specific legal rights. You may have additional rights that may vary
from country to country. Because of individual country regulations, some of the above limitations
and exclusions may not apply to you.
For more information regarding our product line in the USA, please visit www.homedics.com.
For Canada, please visit www.homedics.ca.
FOR SERVICE IN THE USA
8:30am–7:00pm EST Monday–Friday
1-800-466-3342
1-YEAR LIMITED WARRANTY
©2020 HoMedics, LLC. All rights reserved. HoMedics is a registered trademark of HoMedics, LLC.
Distributed by HoMedics, LLC, 3000 N Pontiac Trail, Commerce Township, MI 48390
IB-SANC050
Made in China
FOR SERVICE IN CANADA
8:30am–5:00pm EST Monday–Friday
1-888-225-7378

SAN-C
www.homedics.com/register
Votre contribution précieuse concernant
ce produit nous aidera à créer les
produits que vous désirez.
NOUS VOUS
REMERCIONS DE
PRENDRE LE TEMPS
D’ENREGISTRER VOTRE PRODUIT À L’ADRESSE :
MODE D’EMPLOI ET INFORMATIONS SUR LA GARANTIE
GARANTIE LIMITÉE DE 1 AN
CAS DE DÉSINFECTANT
FRENCH

SAN-C
MANUAL DE INSTRUCCIONES E INFORMACIÓN SOBRE LA GARANTÍA
GARANTÍA LIMITADA DE 1 AÑO
ESTUCHE DESINFECTANTE
SPANISH

ES
ENCENDIDO/APAGADO
CIERRE DE CIERRE
MAGNÉTICO
PUERTO
DE ALIMENTACIÓN
USB
ESTUCHE DESINFECTANTE

www.homedics.com/register
I commenti degli utenti su questo
prodotto sono molto apprezzati e
ci aiutano a creare prodotti che
rispondono alle loro esigenze.
SI
PREGA DI
REGISTRARE IL PRODOTTO ORA A:
MANUALE PER L’USO E GARANZIA
GARANZIA LIMITATA DI 1 ANNO
CUSTODIA DISINFETTANTE
ITALIAN
SAN-C

IT
ALIMENTAZIONE
CHIUSURA
MAGNETICA
PORTA DI
ALIMENTAZIONE
USB
CUSTODIA DISINFETTANTE
/