Symmons 3501-B-LR-X Installation guide

Category
Sanitary ware
Type
Installation guide
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2023 Symmons Industries, Inc. Symmons.com gethelp@symmons.com ZV-3558 REV 0 032723
Shower Trim
Operation and Maintenance Manual
Limited Lifetime - to the original end
purchaser in consumer/residential
installations.
10 Years - for commercial/industrial
installations. Refer to
www.symmons.com/warranty for
complete warranty information.
Warranty
1Remove Test Cap
Valve Setup
Installation - Setting Limit Stop Screw
WARNING: Failure to adjust limit stop screw properly may result in serious scalding.
1) Turn hot and cold supplies on. Valve will not operate unless both hot and cold water supply pressures are on.
2) Place handle on flow control spindle and open valve to maximum desired temperature.
3) Turn limit stop screw clockwise until it seats.
Installation - Adjust Rotation Resistance
1) Turn hot and cold supplies on. Valve will not operate unless both hot and cold water supply pressures are on.
2) Place handle over flow control spindle.
3) Tighten packing nut for positive frictional resistance as handle is rotated from shut-o position across adjustment range.
Warnings:
1. Test cap for pressure testing up to 200 psi maximum (for water). DO NOT exceed 200 psi while pressure testing valve body.
2. Do not expose valve with test cap to heat for longer than 2 minutes when soldering copper tubing. Doing so may damage the internal compo-
nents of the valve and will void the product warranty.
3. Ensure test cap is re-torqued to 30 lb-ft after soldering valve body.
2Install Spindle and Cap
Clean finished trim area with a soft cloth using mild
soap and water or a non-abrasive cleaner and then
quickly rinse with water.
Product Care
Installation Instructions
Tools Required:
Packing Nut
Limit Stop
Screw
For rough-in dimensions refer to submittal
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2023 Symmons Industries, Inc. Symmons.com gethelp@symmons.com ZV-3558 REV 0 032723
1
2
3
Showerhead Installation Shower/Diverter Valve Trim Installation
Hand Shower and Slide Bar Installation
Grab Bar Installation
Wall Cradle Installation
VersaFlex Trim Installation
Plumber's
Tape
Plumber's Tape
For rough-in
dimension refer
to submittal
Screw must be
fastened into
backing board
Screw must be fastened
into backing board
Temptrol Valve
Diverter Valve
Check for
leaks
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2023 Symmons Industries, Inc. Symmons.com gethelp@symmons.com ZV-3558 REV 0 032723
Hand Shower Holder Installation
Tub Spout Installation
1
2
For tub spout rough-in dimensions refer to submittal
TUB/ACCESSORY SHOWER/ACCESSORY
INCREASE DECREASE
Operation (VersaflexTM Diverter Control)
Turn diverter control handle clockwise to
divert to tub spout or other Symmons acces-
sory.
Turn diverter control handle counterclockwise
to divert to shower or other Symmons acces-
sory.
Operation (Volume Control)
Turn volume control handle clockwise to in-
crease volume.
Turn volume control handle counterclockwise
to decrease volume.
Operation Guide
Don't over
tighten
Warning: Remove
burrs before as-
sembly
Slip On Tub Spout
Thread On Tub
Spout
Plumber's Tape
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2023 Symmons Industries, Inc. Symmons.com gethelp@symmons.com ZV-3558 REV 0 032723
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to
cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
1 2 3
Operation (Dual Outlet Diverter Control)
1. Cartridge is factory set to divert to
function 1
2. Turn handle to position 2 to diverter to
function 2
3. Turn handle to position 3 to share
functions 1 and 2
Note: Additional handle positions for same
output are illustrated.
1
POSITION 1
2
POSITION 2
3
POSITION 3
POSITION 4
2
3
POSITION 5
3
1
POSITION 6
2
1
Triple Outlet Diverter Operation
1. Cartridge is factory set to divert
to function 1.
2. Turn handle to position to divert
to function 2.
3. Turn handle to position 3 to divert
to function 3.
4. Turn handle to position 4 to share
functions 2 and 3.
5. Turb handle to position 5 to share
functions 1 and 3.
6. Turn handle to position 6 to share
functions 1 and 2.
12 3
Operation (Temperature Control)
1. Turn shower handle counterclockwise
approximately 1/4 turn to put valve in
cold position
2. Turn shower handle counter-clockwise
approximately 1/2 turn to put valve in
warm position
3. Turn shower handle counter-clockwise
approximately 3/4 turn to put valve in
hot position