Symmons S-4304-STN-1.5-TRM Installation guide

Category
Sanitary ware
Type
Installation guide
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3072 REV A 09/25/14
S-4304-TRM
Sereno
Tub/Hand Shower Trim
Operation & Maintenance Manual
Model Numbers Specifications
S-4304-TRM Tub/Hand Shower Trim
Tub/hand shower trim with lever handle and secondary
integral diverter handle includes wall connection, cradle
for hand shower mounting, non-diverter tub spout,
in-line vacuum breaker, exible metal hose and 1 mode
hand shower with 2.5 gpm (9.5 L/min) ow restrictor.
Components made from metal and nonmetallic materials
plated in standard polished chrome nish.
Modifications Warranty
-1.5 1.5 gpm (5.7 L/min) flow restrictor
-2.0 2.0 gpm (7.6 L/min) flow restrictor
-432HSB 30" slide bar in place of wall cradle on
hand shower units
-STN Satin nickel finish
Limited Lifetime - to the original end purchaser in
consumer installations.
5 Years - for commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Note: Append appropriate -sufx to model number.
2
Dimensions
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3072 REV A 09/25/14
Measurements
A Ø 2 1/4", 57 mm
B
Female 1/2" IPS thread must
be recessed 7/8" from
nished wall
C 5 3/4", 146 mm
D 9 1/4", 235 mm
E 3 1/2", 89 mm
F 32", 813 mm
G 12", 305 mm
H 4 1/2", 114 mm
I 3 1/4", 83 mm
J
(Rough in)
2 3/8" ± 1/2", 60 mm ± 13 mm
K Ø 2 3/8", 60 mm
L 1/2" NPT
M 1/2", 13 mm
N 8 1/2", 216 mm
Notes:
1) All dimensions measured from nominal rough-in (see J as reference).
2) Dimensions are subject to change without notice.
HH
I
I
AA
F
F
G
G
E
E
B
B
J
J
N
N
M
M
L
L
Floor
Floor
D
D
C
C
KK
3
Parts Breakdown
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3072 REV A 09/25/14
Replacement Parts
Item Description Part Number
A
T
Vacuum Breaker
60" Hose
EF-104
B
C
Wall Elbow
Flange
T-444-KIT
D
E
F
G
Plug Button
O-ring
Set Screw
Handle
T-251
H
I
Locknut
Dome Cover
T-19/20-PL
J
K
Mounting Screws
Shower Escutcheon
T-249A
L
M
N
O
P
Cradle Mount
Cradle Mounting Screws
Washer
Cradle Arm
Set Screw
T-545
Q Hand Shower 432W
R Diverter Handle T-30M
S Tub Spout 432TS
Notes:
1) Append -STN to part number for satin nickel nish.
2) Append -1.5 or -2.0 to hand shower for low ow.
Required for Installation
Adjustable wrench
Phillips head screwdriver
Plumber tape
C
Q
A
B
J
T
M
L
O
K
R
G
D
P
N
S
I
H
F
E
4
Installation
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3072 REV A 09/25/14
Note:
For valve body installation, please
see valve body installation guide.
1) Attach secondary integral
diverter (R) to shower
escutcheon (K).
2) Install shower escutcheon (K) to
shower valve. Secure with two
screws (J).
3) Install shower dome cover (I) to
shower valve and secure with
lock nut (H).
4) Install handle (G) to valve.
Secure handle with star washer
(E) and screw (F). Attach
plug button (D) to handle.
Notes: Handles should be facing
the 6 o'clock position.
5) Install tub spout (S) to pipe tting.
Turn clockwise to secure.
6) Install wall elbow
(B)
and ange (C)
to recessed pipe tting. Turn elbow
clockwise to tighten.
7) Press tab to remove mounting
plate (L2) from cradle mount
cover (L1).
Note:
Mounting plate (L2) center
tabs must be horizontal for removal.
R
K
1
2
J
K
1
2
I
H
1
2
3
D
E
F
G
1
2
S
1
2
B
C
2
1
L1
L2
5
Installation
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3072 REV A 09/25/14
8) Place mounting plate
(L2)
in
position, mark and drill 1/8" pilot
holes into stud.
Option:
Place mounting plate
(L2)
in
position, mark and drill 3/16" holes
into wall. Install anchors.
9) Install mounting plate
(L2)
.
Secure with two screws
(M)
.
Replace cradle mount cover (L1).
Note:
Mounting plate (L2) center tabs
must be horizontal for
installation.
10) Attach cradle arm (O) and
washer (N) to cradle mount (L).
Secure with screw (P).
11) Attach large end of
hand shower hose (T) to
hand shower (Q). Attach small
end of hand shower hose (T)
and gasket to in-line vacuum
breaker (A). Connect
in-line vacuum breaker to
wall elbow (B). Turn clockwise
to tighten.
1
3
2
L2
1
3
2
M
L2
L2
L1
3
1
4
2
T
Q
A
T
B
1
2
L2
1
2
L
P
N
O
6
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3072 REV A 09/25/14
Care and Cleaning
1) Clean nished trim area with a soft cloth using mild soap and water or a non-abrasive cleaner and then quickly rinse
with water.
Troubleshooting Chart
Problem Cause Solution
Finish is spotting. Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then
quickly rinse with water.
1) Turn shower handle counterclockwise approximately
1/4 turn to put valve in cold position.
2) Turn shower handle counterclockwise approximately
1/2 turn to put valve in warm position.
3) Turn shower handle counterclockwise approximately
3/4 turn to put valve in hot position.
1) Turn diverter left for tub spout operation.
2) Turn diverter right for hand shower operation.
Operation
Temperature Control Diverter Control
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Symmons S-4304-STN-1.5-TRM Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI