Astria Fireplaces DRC3500 Instruction Sheet

Category
Fireplaces
Type
Instruction Sheet

This manual is also suitable for

Instructions for Field Service Upgrade
on Specified IHP Contemporary
Direct-Vent Gas Fireplaces
Applicable Models Listed Below*
P/N 900915-00 Rev. B 11/2018
For more information, visit IHP.US.com
INSTALLATION INSTRUCTIONS
1. Remove the barrier and glass door. Remove the Porcelain panels,
glass media and the contemporary panel (see Figure 1).
2. Remove the floor and remove both sets of door latch assemblies.
Replace with new door latch assemblies (see Figures 2 and 3).
NOTE: They can be identified by the extra hole above the pull latch
(see Figure 3).
Figure 1
Figure 2
Figure 3
KIT CONTENTS
1 ea. Rear Block-Off Baffle
1 ea. Base, Flue Restrictor
1 ea. Flap, Restrictor
1 ea. Plate, Restrictor Extension
2 ea. Assembly, Door Latch
2 ea. Screw, HWH 10-16X1/2 Typ AB Blk
4 ea. Screw, 10-16x.38 HWH "B" Blk
1 ea. Pilot Hood
1 ea. Installation Instructions
FIELD SERVICE UPGRADES SHALL ONLY BE COMPLETED BY A
QUALIFIED SERVICE TECHNICIAN
TOOLS NEEDED
- 4mm Allen type wrench manual drive
- 1/8” Dia. Flat screw driver manual drive
- 5/16” Hex socket wrench, manual or electric powered
- Mechanical pliers
CAUTION
SHARP EDGES - WATCH YOUR
FINGERS
Wear gloves to guard against any
sharp metal edges.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Field Service Upgrade Kit
Cat. No. F3771 35", 40" and 45" Models
* Affected Fireplace Models
Astria
®
Models Superior
®
Models
ScorpioCD35DEN-B ScorpioCD40DEP-B DRC3535DEN-B DRC3540DEP-B
ScorpioCD35DEP-B ScorpioCD45DEN-B DRC3535DEP-B DRC3545DEN-B
ScorpioCD40DEN-B ScorpioCD45DEP-B DRC3540DEN-B DRC3545DEP-B
Contemporary Panel
Extra hole indicates this is
the new door latch assembly
2
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 4
Figure 5 - Horizontal Restrictor Installation Figure 7
Figure 8
3. If the unit is top vented or has a vent restrictor installed then it should
be removed. The new hinged restrictor will replace it (see Figures
4 through 8).
To Termination
Flap Must
Move Up
Freely
Exhaust
From
Inside
Fireplace
To Termination
Flap Must Move
Up Freely
Exhaust From Inside Fireplace
Base
Restrictor
1
3
20
40
6
20
40
25 ft Maximum
horizontal run (flat to near level)
60 ft Maximum
vertical run *
60
1.9 25
Horizontal Distance (ft)
Vertical Height (ft) from top of unit
Vertical Height (ft)
2
5
Elbow**
5 10 15
Base restrictor
+ wing
6 ft Minimum vertical run*
6 ft Minimum vertical run
None
Base Restrictor
Base Restrictor
+ Wing
Wing
Base
Base
Figure 6 - Vertical Restrictor Installation
3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 9
Figure 10
Figure 11
4. If the unit has the rear block off baffle installed remove the old baffle
and install the new baffle provided in this kit. This baffle is only to
be used on rear vented fireplaces that have no elbows or vertical
pipe sections installed (see Figures 9, 10 and 11).
5. Remove pilot hood by pulling up firmly, discard it and verify proper
pilot gas setting. For Natural gas units the orifice should be turned
counter-clockwise. For Propane (LP) gas units the orifice should
turned clockwise. Some pilot orifices require a small flat standard
screwdriver and some require a 4mm allen type wrench (see Figures
12 and 13).
6. Install new pilot hood provided in this kit by pressing down firmly
until a click is heard. Verify that the pilot hood is properly installed
by lightly pulling up and verifying the spring is still installed (see
Figure 13). NOTE: the pilot hood has a flat spot that will align with
a flat spot inside the pilot cavity.
Figure 12 - Turn Pilot Orifice
Pilot Assemblies may vary. Type ‘A’ pilot will require a flat standard
screwdriver and Type ‘B’ pilot will require a 4mm allen wrench.
AB
Figure 13 - Pilot Hood
Bend Here 90°
Attachment Holes
Pilot Hood
Screwdriver
4 mm Allen
Wrench
Pilot Hood Removed
4
Printed in U.S.A. © 2018 Innovative Hearth Products
P/N 900915-00 Rev. B 11/2018
Innovative Hearth Products (IHP) reserves the right to make changes at any time, without
notice, in design, materials, specifications, prices and also to discontinue colors, styles and
products. Consult your local distributor for fireplace code information.
1769 East Lawrence Street • Russellville, AL 35654
CONTEMPORARY MODELS - IMPORTANT NOTE: Ensure
media does not fall inside the bracket or through the pilot hole.
Figure 14 - Pilot Hole Bracket
Figure 15 - Pilot Hole Bracket
Pilot Hole
Bracket
7. Reinstall the floor, contemporary panel, and glass media. Verify the
contemporary panel (or any other obstruction) will not prevent the
pilot flame from igniting the burner effectively. See Figures 14 and
15.
8. Reinstall the glass door (making sure the gasket if properly seated
against the glass and does not bunch up on top). This door should
swing freely at the bottom and have no scrapping on metal firebox.
9. Reinstall the barrier.
NOTE: Pilot hood shall be as seen above with a unobstructed path.
Pilot Hole
Bracket