  • Hello! I've reviewed the provided mounting instructions for the ifm electronic Peek adapter E30132 and vibration sensor VSA001. This document outlines how to correctly mount the sensor to a machine, specifying the torque requirements and the importance of proper grounding to prevent ground currents. I'm ready to assist with any questions you have about the mounting procedures for these products.
  • What is the maximum permissible tightening torque for the adapter?
    Which vibration sensor type should be used with this adapter?
    Why is ground recommended when using sensors?
    When is it recommended to use the Peek adapter?
Mounting instruction
Peek adapter
E30132
704695 / 01 02 / 2010
2
Functions and features
If sensors are used with the machine, the machine must be grounded according
to the standard. If ground currents (earth potential) cannot be excluded in the
system, it is recommended to use the Peek adapter.
Mounting
Screw the vibration sensor type VSA001 into the adapter (figure 1).
Screw, by means of a torque wrench, adapter and vibration sensor in the
suitable hole of the machine / system via the spanner flat of the adapter
(figure 2), maximum permissible tightening torque 3.5 Nm.
3
Figure 1
vibration sensor type VSA0011:
peek adapter2:
Figure 2
/