Allied Telesis x600-24Ts User manual

Category
Network switches
Type
User manual
613-001248 Rev. A
x600 Series
Layer 3 Gigabit
Ethernet Switches
x600-24Ts
x600-24Ts/XP
x600-48Ts
x600-48Ts/XP
x600-24Ts-POE
Installation Guide
Copyright © 2009 Allied Telesis, Inc.
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
Allied Telesis, Alliedware Plus and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product
names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their
respective owners.
Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document
without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied
Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to
lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc. has been
advised of, known, or should have known, the possibility of such damages.
3
Electrical Safety and Emissions Standards
This product meets the following standards.
RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI
Class A, C-TICK, CE
Warning
In a domestic environment this product may cause radio interference in which case the user
may be required to take adequate measures.
EMC (Immunity) EN55024
Electrical Safety EN60950-1 (TUV), EN60825-1 (TUV), UL 60950-1 (
C
UL
US
), CSA-C22-2
No. 60950-1 (
C
UL
US
)
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15
of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate
this equipment.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Laser Safety EN60825
4
Translated Safety Statements
Important: The indicates that a translation of the safety statement is available in a PDF
document titled “Translated Safety Statements” (613-000990) posted on the Allied Telesis website at
www.alliedtelesis.com.
5
Contents
Product Documentation .................................................................................................................................... 14
Starting a Management Session ...................................................................................................................... 15
Safety Symbols Used in this Document ........................................................................................................... 16
Where to Find Web-based Guides ................................................................................................................... 17
Contacting Allied Telesis .................................................................................................................................. 18
Online Support ........................................................................................................................................... 18
Email and Telephone Support.................................................................................................................... 18
Warranty..................................................................................................................................................... 18
Returning Products .................................................................................................................................... 18
Sales or Corporate Information .................................................................................................................. 18
Management Software Updates................................................................................................................. 18
Chapter 1: Overview ...................................................................................................................................... 19
Introduction....................................................................................................................................................... 20
Switch Descriptions .......................................................................................................................................... 21
x600-24Ts Switch....................................................................................................................................... 21
x600-24Ts/XP Switch................................................................................................................................. 22
x600-48Ts Switch....................................................................................................................................... 23
x600-48Ts/XP Switch................................................................................................................................. 24
x600-24TS-POE......................................................................................................................................... 25
10/100/1000Base-T Ports................................................................................................................................. 26
Connector Type.......................................................................................................................................... 26
Speed......................................................................................................................................................... 26
Duplex Mode .............................................................................................................................................. 26
Maximum Distance..................................................................................................................................... 26
Cable Type................................................................................................................................................. 27
Auto-MDI/MDI-X......................................................................................................................................... 27
Port Pinouts................................................................................................................................................ 27
SFP Transceiver Slots...................................................................................................................................... 28
XFP Transceiver Slots...................................................................................................................................... 29
Combo Ports..................................................................................................................................................... 30
SD Card Slot..................................................................................................................................................... 31
Port LEDs ......................................................................................................................................................... 32
10/100/1000
Base-T LEDs .................................................................................................................................................... 32
SFP LEDs .................................................................................................................................................. 34
XFP Transceiver Slot LEDs ....................................................................................................................... 35
System STATUS LEDs..................................................................................................................................... 36
STACK LEDs.................................................................................................................................................... 37
Secure Digital (SD) LED................................................................................................................................... 39
Terminal Port .................................................................................................................................................... 40
Power Over Ethernet ........................................................................................................................................ 41
Power Budgeting........................................................................................................................................ 41
Implementation........................................................................................................................................... 42
Redundant Power Supplies .............................................................................................................................. 44
AT-LBM (Loop Back) Module ........................................................................................................................... 45
Contents
6
VCS Stacking Module ....................................................................................................................................... 46
AC Power Connector ........................................................................................................................................ 47
Chapter 2: Virtual Chassis Stacking ............................................................................................................49
VCStack
TM
Introduction ....................................................................................................................................50
Features of VCStacking..............................................................................................................................50
The Physical Stack .....................................................................................................................................50
Resiliency Link............................................................................................................................................52
VCStack Recovery States ..........................................................................................................................52
Resiliency Link Configurations via Switch Ports......................................................................................... 54
Resilient Stacked Topology ........................................................................................................................55
Stack Formation................................................................................................................................................ 56
The Role of the Stack Master .....................................................................................................................56
Stack Member Failure and Recovery .........................................................................................................59
VCS Failure Recovery ................................................................................................................................ 60
Stack Maintenance .....................................................................................................................................61
Chapter 3: Installing the Hardware ............................................................................................................... 63
Reviewing Safety Precautions ..........................................................................................................................64
Unpacking a Switch ..........................................................................................................................................67
Installing the Power Cord Retaining Clip .......................................................................................................... 68
Installing the Switches in an Equipment Rack ..................................................................................................69
Resetting the Switch ......................................................................................................................................... 71
VC Stacking Module Installation .......................................................................................................................72
Overview..................................................................................................................................................... 72
Preparation .................................................................................................................................................72
Installing the AT-StackXG Module..............................................................................................................73
Chapter 4: Cabling the Network Ports .........................................................................................................77
Twisted Pair and Fiber Optic Specifications ..................................................................................................... 78
Twisted Pair Cable Specifications ..............................................................................................................78
SFP/XFP Transceiver Specifications..........................................................................................................79
Installing SFP/XFP Transceivers ...................................................................................................................... 80
Installing an SFP Transceiver.....................................................................................................................80
Installing an XFP Transceiver.....................................................................................................................83
Cabling the 10/100/1000Base-T and Fiber Optic Ports ....................................................................................85
Powering on a Switch .......................................................................................................................................86
Starting a Local Management Session....................................................................................................... 87
Warranty Registration .......................................................................................................................................89
Chapter 5: Troubleshooting ..........................................................................................................................91
Power LED is Off ..............................................................................................................................................92
Twisted Pair Port Link LED is Off......................................................................................................................93
SFP or XFP LED is Off .....................................................................................................................................94
Transceiver is Installed but the Status is “Not Present” ....................................................................................95
System Fault LED is Blinking ............................................................................................................................ 96
System Fault LED is Steadily On ...................................................................................................................... 97
Cannot Establish a Local (Out-of-Band) Management Session........................................................................ 98
Switch Functions Intermittently .........................................................................................................................99
Issues with Virtual Stacking Chassis Configuration ........................................................................................100
Appendix A: Technical Specifications .......................................................................................................101
Physical Specifications ...................................................................................................................................101
Environmental Specifications ..........................................................................................................................101
Power Specifications.......................................................................................................................................103
Certifications ...................................................................................................................................................103
RJ-45 Twisted Pair Port Pinouts .....................................................................................................................104
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide
7
RJ-45 Style Serial Terminal Port Pinouts ....................................................................................................... 106
AT-RPS3104 17-pin Connector Pinouts......................................................................................................... 106
AT-RPS3204 21-pin D-combo Port and Connector Pinouts........................................................................... 108
Contents
8
9
Figure 1. x600-24Ts Switch.................................................................................................................................................21
Figure 2. x600-24Ts/XP Switch ...........................................................................................................................................22
Figure 3. x600-48Ts Switch.................................................................................................................................................23
Figure 4. x600-48Ts/XP Switch ...........................................................................................................................................24
Figure 5. x600-24Ts-POE Switch ........................................................................................................................................25
Figure 6. SFP Transceiver...................................................................................................................................................28
Figure 7. XFP Transceiver...................................................................................................................................................29
Figure 8. SD Card Slot ........................................................................................................................................................31
Figure 9. SD Card................................................................................................................................................................31
Figure 10. Port LEDs on x600-24Ts and x600-24Ts/XP Switches......................................................................................32
Figure 11. Port LEDs on x600-48Ts and the x600-48Ts/XP Switches................................................................................32
Figure 12. Port LEDs on x600-24Ts-POE Switch................................................................................................................33
Figure 13. SFP LEDs - x600-24 Port Switch .......................................................................................................................34
Figure 14. SFP LEDs - x600-48 Port Switch .......................................................................................................................35
Figure 15. XFP LEDs on x600-24Ts/XP and x600-48Ts/XP Switches................................................................................35
Figure 16. System STATUS LEDs.......................................................................................................................................36
Figure 17. Non PoE Switch STACK LEDs...........................................................................................................................37
Figure 18. x600-24/Ts-POE STACK LEDs..........................................................................................................................37
Figure 19. Secure Digital Slot LED......................................................................................................................................39
Figure 20. AT-RPS3204 Redundant Power Supply Unit .....................................................................................................44
Figure 21. AT-LBM Module installed in x600-48Ts/XP Expansion Slot...............................................................................45
Figure 22. VCS Stacking Module (AT-StackXG) .................................................................................................................46
Figure 23. Back-to-Back Topology (x600 Switches)............................................................................................................51
Figure 24. VCS Ring Topology Using x600 Switches..........................................................................................................52
Figure 25. Resiliency link connecting to switch ports over the ResiliencyLink VLAN ..........................................................54
Figure 26. Resiliency link connecting to switch ports over the ResiliencyLink VLAN using a network hub.........................54
Figure 27. STACK and STATUS LEDs................................................................................................................................58
Figure 28. Power Cord Retaining Clip .................................................................................................................................68
Figure 29. Inserting the Retaining Clip into the Retaining Bracket ......................................................................................68
Figure 30. Removing the Feet .............................................................................................................................................69
Figure 31. Attaching Rack-Mount Brackets .........................................................................................................................69
Figure 32. Mounting the Switch in a Rack ...........................................................................................................................70
Figure 33. Resetting the Switch...........................................................................................................................................71
Figure 34. VC Stacking (AT-StackXG) Module....................................................................................................................72
Figure 35. Removing the Blank Panel from the Expansion Slot..........................................................................................73
Figure 36. Installing the AT-StackXG Stacking Module.......................................................................................................74
Figure 37. Securing the AT-StackXG Stacking Module.......................................................................................................74
Figure 38. Removing the Plastic Protector ..........................................................................................................................75
Figure 39. Removing a Dust Plug from an SFP Slot ...........................................................................................................80
Figure 40. Installing an SFP Transceiver.............................................................................................................................81
Figure 41. Positioning Handles on the x600-24Ts and x600-24Ts/XP Switches.................................................................81
Figure 42. Positioning SFP Handles on the x600-48Ts and x600-48Ts/XP Switches.........................................................82
Figure 43. Removing an XFP Dust Plug..............................................................................................................................83
Figure 44. Installing an XFP Transceiver.............................................................................................................................83
Figure 45. Power Cord Retaining Clip in the Up Position ....................................................................................................86
Figure 46. Connecting the AC Power Cord .........................................................................................................................86
Figure 47. Connecting the Management Cable to the RJ-45 Terminal Port on the Switch .................................................87
Figure 48. RJ-45 Connector and Port Pin Layout..............................................................................................................104
Figure 49. AT-RPS3104 17-Pin Connector Layout............................................................................................................106
Figure 50. AT-RPS3204 21-pin D-combo Connector and Port Pin Layout........................................................................108
List of Figures
Figures
10
11
Table 1. Safety Symbols .....................................................................................................................................................16
Table 2. 10/100/1000Base-T Ports Matched with SFP Slots ..............................................................................................30
Table 3. Non-PoE Switch Base-T LED Descriptions ..........................................................................................................33
Table 4. SFP Slot LED Descriptions ...................................................................................................................................35
Table 5. XFP Slot LED .......................................................................................................................................................35
Table 6. System STATUS LEDs .........................................................................................................................................36
Table 7. STACK LEDs ........................................................................................................................................................38
Table 8. Secure Digital LED ...............................................................................................................................................39
Table 9. IEEE 802.3af Class vs. Power Levels ..................................................................................................................42
Table 10. Stacking Compatibility by Product Type .............................................................................................................50
Table 11. State Change Table ............................................................................................................................................53
Table 12. Stacking LED Functions .....................................................................................................................................58
Table 13. Twisted Pair Cabling and Distances ...................................................................................................................78
Table 14. MDI Pin Signals - 10 or 100 Mbps ....................................................................................................................104
Table 15. MDI-X Pin Signals - 10 or 100 Mbps ................................................................................................................104
Table 16. Pin Signals - 1000 Mbps ...................................................................................................................................105
Table 17. RJ-45 Style Serial Terminal Port Pin Signals ...................................................................................................106
Table 18. AT-RPS3104 17-Pin Connector Pinout Definitions ...........................................................................................107
Table 19. AT-RPS3204 21-pin Connector Pinout Definitions ...........................................................................................108
List of Tables
Tables
12
13
Preface
This guide contains the installation instructions for the x600 Series Layer 3
Gigabit Ethernet Switches. This preface contains the following sections:
“Product Documentation” on page 14
“Starting a Management Session” on page 15
“Safety Symbols Used in this Document” on page 16
“Where to Find Web-based Guides” on page 17
“Contacting Allied Telesis” on page 18
Preface
14
Product Documentation
For overview information about the software features of the AlliedWare
Plus
Operating System Software which runs on the x600 Series Switches,
refer to:
AlliedWare Plus
Operating System Software Reference Guide
Virtual Chassis Stacking (VCS) How To Note
AT-StackXG Stacking Module Installation Guide
x600 Layer 3 Gigabit Ethernet Switch Installation Guide
15
Starting a Management Session
For instructions that describe how to start a local management session on
an x600 switch, refer to the “Starting a Local Management Session” on
page 87. For information that describes how to log onto the AlliedPlus
TM
Operating System Software, see the AlliedWare Plus
Operating System
Software Reference Guide.
Preface
16
Safety Symbols Used in this Document
This document uses the safety symbols defined in Table 1.
Table 1. Safety Symbols
Symbol Meaning Description
Caution Performing or omitting a specific action may
result in equipment damage or loss of data.
Warning Performing or omitting a specific action may
result in electrical shock.
x600 Layer 3 Gigabit Ethernet Switch Installation Guide
17
Where to Find Web-based Guides
The installation and user guides for all Allied Telesis products are available
in portable document format (PDF) on our web site at
www.alliedtelesis.com. You can view the documents online or download
them onto a local workstation or server.
Preface
18
Contacting Allied Telesis
This section provides Allied Telesis contact information for technical
support as well as sales and corporate information.
Online Support You can request technical support online by accessing the Allied Telesis
Knowledge Base at www.alliedtelesis.com/support and selecting the
“Read More” link under Knowledge Base. You can use the Knowledge
Base to submit questions to our technical support staff and review
answers to previously asked questions.
Email and
Telephone
Support
For Technical Support via email or telephone, refer to the Support section
of the Allied Telesis web site: www.alliedtelesis.com.
Warranty For warranty information on the x600 Series Layer 3 Gigabit Ethernet
Switches, go to www.alliedtelesis.com/warranty for the specific terms
and conditions of the warranty and for warranty registration.
Returning
Products
Products for return or repair must first be assigned a return materials
authorization (RMA) number. A product sent to Allied Telesis without an
RMA number will be returned to the sender at the sender’s expense. For
instructions on how to obtain an RMA number, go to the Support section
on our web site at www.alliedtelesis.com.
Sales or
Corporate
Information
You can contact Allied Telesis for sales or corporate information through
our web site at www.alliedtelesis.com.
Management
Software Updates
New releases of the management software for our managed products are
available from the following Internet sites:
Allied Telesis web site: www.alliedtelesis.com
Allied Telesis FTP server: ftp://ftp.alliedtelesis.com
If the FTP server prompts you to log on, enter “anonymous” as the user
name and your email address as the password.
19
Chapter 1
Overview
This chapter contains the following sections:
“Introduction” on page 20
“Switch Descriptions” on page 21
“10/100/1000Base-T Ports” on page 26
“SFP Transceiver Slots” on page 28
“XFP Transceiver Slots” on page 29
“Combo Ports” on page 30
“SD Card Slot” on page 31
“Port LEDs” on page 32
“System STATUS LEDs” on page 36
“STACK LEDs” on page 37
“Secure Digital (SD) LED” on page 39
“Terminal Port” on page 40
“Power Over Ethernet” on page 41
“Redundant Power Supplies” on page 44
“AT-LBM (Loop Back) Module” on page 45
“VCS Stacking Module” on page 46
“AC Power Connector” on page 47
Note
Do not begin the installation procedures in this guide until you have
read the AlliedWare Plus
Operating System Software Release Notes
that are included with the latest release of the AlliedWare Plus
Operating System Software.
Chapter 1: Overview
20
Introduction
The x600 Series Switches are managed Gigabit Ethernet switches that act
as standalone units. There are five Basic Layer 3 switches in the series:
x600-24Ts Switch
x600-24Ts/XP Switch
x600-48Ts Switch
x600-48Ts/XP Switch
x600-24Ts-POE Switch
The AlliedWare Plus
Operating System Software (AW+) runs on all the
x600 switches. The x600-24Ts-POE requires AW+ software version 5.3.3
or later for IEEE 802.3af support
For more detailed information about the switches, including illustrations,
see “Switch Descriptions” on page 21.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110

Allied Telesis x600-24Ts User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI