1.2 Technical Characteristics
≤ 20 milliseconds Switch Time
24VDC @ 2.4 Amps or 48VDC @ 1.8 Amps, maximum
DC Switching
DB9 (female) Ext. Alarms In, M&C Connector
Front Panel Switch Auto/Manual
IF/L-Band Switch Characteristics
Alarm and Control, M&C
Connectors, Indicators
Connectors, Other
Latching Relay, 2PDT, No Termination
Type, Configuration
≤ 2.0 dB, at 10 to 25 MHz
1.5 dB max, ≤ 1.0 dB typical; 0.95 to 1.5 GHz
2.5 dB max, ≤ 2.0 dB typical; 1.5 to 2.15 GHz
Insertion Loss
≤ 50 dB, at 10 to 25 MHz
50 dB minimum, ≥ 55 dB typical,0.95 to 2.15 GHz
45 dB minimum, ≥ 50 dB typical; 1.5 to 2.15 GHz
Isolation
≤ ±0.5 dB, 40 MHz BW, ≤ ±1.5 dB, 0.95 to 2.15 GHz Frequency Response
RS232C or RS422/485, Selectable/9600 (Ethernet Optional)
M&C Interface / Baud Rate
Form C relay: 30VDC, 0.5A Maximum
Alarm Output Signal
12 dB minimum, ≥ 14 dB typical; 0.95 to 1.5 GHz
10 dB minimum, ≥ 12 dB typical; 1.5 to 2.15 GHz
Return Loss
75Ω / BNC Impedance / Connectors
TABLE 1.0 1582-122L 1:1 Switch, Specifications*
Redundant 100-240 ±10% VAC, 47-63 Hz.,
30 Watts maximum Power Supplies.
Power
1 RU, 19 inch Standard Chassis, 1.75” high x 12.0” deep Size
75Ω BNC (female) RF, Connectors
*10˚C to 40˚C; Specifications subject to change without notice. Cross Technologies, Inc.
Green, Yellow, Red, Red LED - Form C contact closure, M&C Power, Remote, Manual, Alarm
Front Panel Switches or M&C Switch Reset, History Reset
(Technical Characteristics continued on page 5...)
1582-122L Manual, Rev. 0 Page 4 10/06/14