Gossen MetraWatt PROFITEST 0100S-II+ is a versatile electrical tester that can perform a wide range of measurements, including:
- Insulation resistance testing
- Continuity testing
- Loop impedance testing
- Earth resistance testing
- Phase sequence testing
- RCD tripping time and current testing
- Battery testing
The PROFITEST 0100S-II+ is a valuable tool for any electrician or engineer, as it can help to ensure the safety and reliability of electrical installations. With its easy-to-use interface and comprehensive measurement capabilities, the PROFITEST 0100S-II+ is the ideal choice for a wide range of electrical testing applications.
Kurzbedienungsanleitung Brevi istruzioni d’uso
Short-form Operating Instructions Verkorte gebruiksaanwijzing
Mode d’emploi en bref StruÎný n‰vod
Breves instrucciones de servicio
PROFITEST 0100S-II+ / PROFITEST⏐ONE
3-348-890-27
7/6.07
START
I
Δ
N
MENU
GMC-I Gossen-Metrawatt GmbH 7
U
L-N
/ U
L-PE
f
1. 3. 4.2.
U
L-N
U
L-PE
MENU
START
GB F E I NL CZD
GMC-I Gossen-Metrawatt GmbH 8
U3~U3~U3~U3~U3~U3~U3~
Drehfeld Phase sequence Champs tournant Trifásico Senso ciclico Draaiveld Sied fází
1. 2. 3.
U
L-PE
MENU
GMC-I Gossen-Metrawatt GmbH 9
4.
Rechtsdrehfeld
Right rotation
Rotation à droite
Sentido de giro normal
Senso ciclico DX
Rechts draaiveld
Pravotocivé pole
Linkssdrehfeld
Left rotation
Rotation à gauche
Sentido de giro inverso
Senso ciclico SX
Links draaiveld
Levotocivé pole
PE oder N an Phase
PE or N on phase
PE on N en phase
PE o N en fase
PE o N a fase
PE of N aan de fase
PE nebo N pod napetím
START
GB F E I NL CZD
GMC-I Gossen-Metrawatt GmbH 10
Z
ST
Z
ST
Z
ST
Z
ST
Z
ST
Z
ST
Z
ipo
Standort- Site insulation Isolement Aislado Resistività Vloerisolatie- Izolace
isolation du site pavimento weerstand stanovište
1. 3. 4.2.
R
E
MENU
START
GB F E I NL CZD
GMC-I Gossen-Metrawatt GmbH 11
Folgende Mes-
sungen sind nur
an spannungs-
freien Mess-
objekten
möglich.
Fremdspannung
sperrt die
Messung!
R
LO
/R
ISO
R
LO
/R
ISO
R
LO
/R
ISO
R
LO
/R
ISO
R
LO
/R
ISO
R
LO
/R
ISO
R
LO
/R
ISO
The following
measurements
are possible on
electrically dead
devices.
External voltage
disables the
measurement!
Les mesures
suivantes ne sont
possibles qu
’avec des
appareils sans
tension.
La tension indé-
pendante arrête
la mesure!
Las siguientes
mediciones son
factibles sólo
sobre objetos
exentos de
tensión.
La tensión ajena
bloquea la medi-
ción!
Le seguenti
misure sono
possibili soltano
se l’oggetto da
misura è privo di
tensione.
Le tensioni
esterne impedis-
cono la misura!
De volgende
metingen zijn
alleen aan
spanningsloze
meetobjecten
mogelijk.
Stoorspanning
blokkeert de
meting!
Následující
merení se
provádejí v zarí-
zeních bez
napetí.
Cizí napetí
blokuje merení!
GB F E I NL CZD
GMC-I Gossen-Metrawatt GmbH 15
Hilfe Request Demander Solicitar Chiedere Hulp Nápoveda
anfordern help help help help inroepen
1. 3.2. 4.
MENU MENU
I
ΔN
i
I
ΔN
i
I
ΔN
i
GMC-I Gossen-Metrawatt GmbH
Thomas-Mann-Str. 16-20
90471 Nürnberg •
Germany
Telefon +49 911 8602-111
Telefax +49 911 8602-777
E-Mail
www.gossenmetrawatt.com
Gedruckt in Deutschland Printed in Germany Imprimé en Allemagne Impreso en Alemania Stampato in Germania Gedrukt in Duitsland TiötÔno v
Änderungen vorbehalten Subject to change Sous réserve de Reservados todos los Con riserva di modifiche Wijzigingen voorbehouden NÔmecku
without notice modifications derechos
GB F E I NL CZD