Ingersoll-Rand 14/85 User manual

Category
Power supply units
Type
User manual
7/120, 9/110, 10/105, 14/85
7/170, 10/125, 14/115
This manual contains
important safety information
and must be made available to
personnel who operate and
maintain this machine.
7/120 9/110
–>SERIAL No : 32000110/105 14/85
C.C.N. : 22191225 GB
DATE : SEPTEMBER 2003
OPERATION AND MAINTENANCE MANUAL
7/170 10/125 14/115
Machine models represented in this manual may be used in various locations world–wide. Machines sold
and shipped into European Union Territories require that the machine display the EC Mark and conform
to various directives. In such cases, the design specification of this machine has been certified as
complying with EC directives. Any modification to any part is absolutely prohibited and would result in
the CE Certification and marking being rendered invalid. A declaration of that conformity follows:
DECLARATION OF CONFORMITY WITH EC DIRECTIVES
We
Declare that, under our sole responsibility for manufacture and supply, the product(s)
98/37/EC, 93/68/EEC, 89/336/EEC
IngersollRand Company
P.O. Box 868
501 Sanford Avenue
Mocksville, North Carolina 27028
IngersollRand Company Limited
Swan Lane
Hindley Green
Wigan WN2 4EZ
United Kingdom
Represented in EC by:
to which this declaration relates, is (are) in conformity with the provisions of the above
directives using the following principal standards
Issued at Mocksville on
112003
Issued at Hindley Green on
112003
EN29001 : EN292, EN602041, EN10121, PN8NTC2, EN50081, EN50082
________________________________
________________________________
7/120 (P425AWIR) 9/110 (XP375AWIR) 10/105 (HP375AWIR)
14/85 (VHP300AWIR)
Harry Seddon
Quality assurance manager
Ric Lunsford
Manager of quality control
CONFORMITY WITH NOISE DIRECTIVE 2000/14/EC
IngersollRand Company Limited declare that the following Portable Compressors have been
manufactured in conformity with the directive as shown
Machine
Mean
Guaranteed
Directive
Type kW
measured
value
Guaranteed
Level
Notified body
14/85WIR
2000/14/EC
10/105WIR
A V Technology
Annex VI
Part I
9/110WIR
93 100.2 L
WA
101 L
WA
Stockport UK
Nr 1067Part I
7/120WIR
Nr 1067
________________________________
Issued at Mocksville, NC. . . . . . . . .
1st Declaration January 11, 2003. . . .
Ric Lunsford
Manager of quality control
EC Pressure Equipment Directive and Related Regulations
We declare that this product has been assessed according to the Pressure Equipment Directive (97/23/EC)
and, in accordance with the terms of this Directive, has been excluded from the scope of this Directive.
It may carry ”CE” marking in compliance with other applicable EC Directives.
Machine models represented in this manual may be used in various locations worldwide. Machines sold
and shipped into European Union Territories require that the machine display the EC Mark and conform
to various directives. In such cases, the design specification of this machine has been certified as
complying with EC directives. Any modification to any part is absolutely prohibited and would result in
the CE Certification and marking being rendered invalid. A declaration of that conformity follows:
We
Declare that, under our sole responsibility for manufacture and supply, the product(s)
98/37/EC, 93/68/EEC, 89/336/EEC
IngersollRand Company
P.O. Box 868
501 Sanford Avenue
Mocksville, North Carolina 27028
IngersollRand Company Limited
Swan Lane
Hindley Green
Wigan WN2 4EZ
United Kingdom
Represented in EC by:
to which this declaration relates, is (are) in conformity with the provisions of the above
directives using the following principal standards
Issued at Mocksville on
112003
Issued at Hindley Green on
112003
EN29001 : EN292, EN602041, EN10121, PN8NTC2, EN50081, EN50082
________________________________
________________________________
7/170 (P600WIR) 10/125 (HP450WIR) 14/115 (VHP400WIR)
Harry Seddon
Quality assurance manager
Ric Lunsford
Manager of quality control
DECLARATION OF CONFORMITY WITH EC DIRECTIVES
CONFORMITY WITH NOISE DIRECTIVE 2000/14/EC
IngersollRand Company Limited declare that the following Portable Compressors have been
manufactured in conformity with the directive as shown
Machine
Mean
Guaranteed
Directive
Type kW
measured
value
Guaranteed
Level
Notified body
2000/14/EC
14/115
A V Technology
2000/14/EC
Annex VI
10/125
126.5 100.2 L
WA
101 L
WA
A V Technology
Stockport UK
Part I
7/170
WA WA
Nr 1067
________________________________
Issued at Mocksville, NC. . . . . . . . .
1st Declaration January 11, 2003. . . .
Ric Lunsford
Manager of quality control
EC Pressure Equipment Directive and Related Regulations
We declare that this product has been assessed according to the Pressure Equipment Directive (97/23/EC)
and, in accordance with the terms of this Directive, has been excluded from the scope of this Directive.
It may carry CE marking in compliance with other applicable EC Directives.
1
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
1 CONTENTS
2 FOREWORD
3 WARRANTY
9 DECALS
13 SAFETY
16 GENERAL INFORMATION
Dimensions
Data
21 OPERATING INSTRUCTIONS
Commissioning
Prior to starting
Starting
Stopping
Emergency stopping
Restarting
Monitoring during operation
Decommissioning
29 ENGINE INSTRUCTION MANUAL
46 MAINTENANCE
Routine maintenance
Lubrication
Speed & pressure regulation
Torque settings table
Compressor lubrication
58 MACHINE SYSTEMS
Electrical system
Piping & instrumentation system
61 SERVICE TOOLS
65 FAULT FINDING
67 OPTIONS
70 PARTS ORDERING
ABBREVIATIONS & SYMBOLS
#### Contact IngersollRand for serial
number
>#### Up to Serial No.
####> From Serial No.
* Not illustrated
Option
AR As required
D Germany
DK Denmark
E Spain
F France
GB Great Britain
HA High ambient machine
I Italy
N Norway
NL Netherlands
P Portugal
S Sweden
SF Finland
F.H.R.G. Fixed height running gear
V.H.R.G. Variable height running gear
2
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
FOREWORD
The contents of this manual are considered to be proprietary
and confidential to IngersollRand and should not be
reproduced without the prior written permission of
IngersollRand.
Nothing contained in this document is intended to extend any
promise, warranty or representation, expressed or implied,
regarding the IngersollRand products described herein. Any
such warranties or other terms and conditions of sale of
products shall be in accordance with the standard terms and
conditions of sale for such products, which are available upon
request.
This manual contains instructions and technical data to
cover all routine operation and scheduled maintenance tasks by
operation and maintenance staff. Major overhauls are outside
the scope of this manual and should be referred to an authorised
IngersollRand service department.
The design specification of this machine has been certified
as complying with EC directives. As a result:
(a)Any machine modifications are strictly prohibited, and will
invalidate EC certification.
(b)A unique specification for USA/Canada is adopted and
tailored to the territory.
All components, accessories, pipes and connectors added
to the compressed air system should be:
. of good quality, procured from a reputable manufacturer and,
wherever possible, be of a type approved by IngersollRand.
. clearly rated for a pressure at least equal to the machine
maximum allowable working pressure.
. compatible with the compressor lubricant/coolant.
. accompanied with instructions for safe installation,
operation and maintenance.
Details of approved equipment are available from
Ingersoll–Rand Service departments.
The use of repair parts / lubricants / fluids other than those
included within the IngersollRand approved parts list may
create hazardous conditions over which IngersollRand has no
control. Therefore IngersollRand cannot be held responsible
for equipment in which nonapproved repair parts are installed.
IngersollRand reserves the right to make changes and
improvements to products without notice and without incurring
any obligation to make such changes or add such
improvements to products sold previously.
The intended uses of this machine are outlined below and
examples of unapproved usage are also given, however
IngersollRand cannot anticipate every application or work
situation that may arise.
IF IN DOUBT CONSULT SUPERVISION.
This machine has been designed and supplied for use only in
the following specified conditions and applications:
. Compression of normal ambient air containing no known or
detectable additional gases, vapours. or particles
. Operation within the ambient temperature range specified in
the GENERAL INFORMATION section of this manual.
UNITS MANUFACTURED IN NORTH AMERICA: Generation
of electricity at 120V (1ph) at 60 Hertz.
UNITS MANUFACTURED IN EUROPE: Generation of
electricity not applicable.
The use of the machine in any of the situation types
listed in table 1:
a) Is not approved by IngersollRand,
b) May impair the safety of users and other persons, and
c) May prejudice any claims made against IngersollRand.
TABLE 1
Use of the machine to produce compressed air for:
a) direct human consumption
b) indirect human consumption, without suitable filtration and
purity checks.
Use of the machine outside the ambient temperature range
specified in the GENERAL INFORMATION SECTION of this
manual.
This machine is not intended and must not be used in
potentially explosive atmospheres, including situations where
flammable gases or vapours may be present.
Use of the machine fitted with non IngersollRand approved
components / lubricants / fluids.
Use of the machine with safety or control components
missing or disabled.
Use of the machine for storage or transportation of materials
inside or on the enclosure except when contained within the
toolbox.
GENERATOR
Use of the generator to supply load(s) greater than those
specified.
Use of unsafe or unserviceable electrical equipment
connected to the generator.
Use of electrical equipment:
(a) Having incorrect voltage and/or frequency ratings.
(b) Containing computer equipment and/or similar electronics.
The company accepts no responsibility for errors in
translation of this manual from the original English version.
COPYRIGHT 2003
INGERSOLLRAND COMPANY
3
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
WARRANTY
IngersollRand, through its distributor, warrants that each item
of equipment manufactured by it and delivered hereunder to the
initial user will be free of defects in material and workmanship.
With respect to the following types of equipment, the warranty
period enumerated below will apply.
A. Aftercoolers The earlier of nine (9) months from date
of shipment to or six (6) months from start up by initial user.
B. Portable Compressors, Portable Generator Sets
(GENSET), Portable Light Towers and Air Dyers The
earlier of twelve (12) months from shipment to or the
accumulation of 2,000 hours of service by the initial user.
C. Portable Compressor Air Ends The earlier of
twentyfour (24) months from shipment to or the
accumulation of 4,000 hours of service by the initial user.
For Air Ends, the warranty against defects will include
replacement of the complete Air End, provided the original
Air End, is returned assembled and unopened.
C.1 Portable Compressor Airend Limited Optional
Warranty The earlier of sixty (60) months from shipment
to or the accumulation of 10,000 hours of service. The
optional warranty is limited to defects in rotors, housings,
bearings and gears and provided all the following
conditions are met:
The original airend is returned assembled and unopened.
Continued use of genuine IngersollRand parts, fluids,
oils and filters.
Maintenance is performed at prescribed intervals.
D. Genset Generators The earlier of twentyfour (24)
months from shipment to or the accumulation of 4,000
hours of service by the initial user.
E. Portable Light Tower Generators The earlier of twelve
(12) months from shipment to or the accumulation of 2,000
hours of service by the initial user. Light Source model
only, the earlier of twentyfour (24) months from shipment
to or the accumulation of 4,000 hours of service.
F. IngersollRand Engines The earlier of twentyfour
(24) months from shipment to or the accumulation of 4,000
hours of service.
G. IngersollRand Platinum Drive Train Warranty
(Optional) Platinum drive train pertains to the
IngersollRand Engine and Airend combination. The
earlier of sixty (60) months from shipment to, or the
accumulation of 10,000 hours of service. The starter,
alternator, fuel injection system and all electrical
components are excluded from the extended warranty.
The airend seal and drive coupling are included in the
warranty (airend drive belts are not included). The
optional warranty is automatically available when meeting
the following conditions:
The original airend is returned assembled and unopened.
Continued use of genuine IngersollRand parts, fluids, oil
and filters.
Maintenance is performed at prescribed intervals.
It is the obligation of the user to provide verification that
these conditions have been satisfied when submitting
warranty claims.
H. Spare Parts Six (6) months from date of installation
IngersollRand will provide a new part or repaired part, at its
election, in place of any part which is found upon its inspection
to be defective in material and workmanship during the period
prescribed above. Such part will be repaired or replaced without
charge to the initial user during normal working hours at the
place of business of an IngersollRand distributor authorized to
sell the type of equipment involved or other establishment
authorized by Ingersoll Rand. User must present proof of
purchase at the time of exercising warranty.
The above warranty does not apply to failures occurring as a re-
sult of abuse; misuse, negligent repairs, corrosion, erosion and
normal wear and tear, alterations or modifications made to the
product without express written consent of IngersollRand; or
failure to follow the recommended operating practices and
maintenance procedures as provided in the products operating
and maintenance publications.
Accessories or equipment furnished by IngersollRand, but
manufactured by others, including, but not limited to, engines,
tires, batteries, engine electrical equipment, hydraulic
transmissions, carriers, shall carry whatever warranty the
manufacturers have conveyed to IngersollRand and which
can be passed on to the initial user.
THIS WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES EXPRESSED OR IMPLIED, (EXCEPT THAT
OF TITLE), AND THERE ARE NO WARRANTIES OF
MERCHANTABILITY OR OF FITNESS FORA PARTICULAR
PURPOSE.
4
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
GENERAL WARRANTY INFORMATION
GENERAL WARRANTY Extended Coverage
Portable Compressor Package 1 year/2000 hrs
Airend 2 yrs/4000 hrs 5 yrs/10,000 hrs
Limited warranty, major compo-
nents (refer to operators manual).
Portable Genset 8kW, 11KW,
20KVA thru 575KVA
Package 1 yr/2000 hrs None
Generator 2 yrs/4000 hrs None
Portable Genset 3.5KW thru
7.0KW and 10KW
Package 1 yr/2000 hrs (parts only) None
Generator 1 yrs/2000 hrs (parts only) None
Light Tower Package 1 yr/2000 hrs
Generator 1 yr/2000 hrs 2 years/4000 hours, for Lightsource
introduced 8/16/99.
ENGINES
CATERPILLAR Months Hours Extended Coverage
12 unlimited Available at dealer
CUMMINS 24 2000 Major components 3 yrs/10,000 hrs
Available at dealer
JOHN DEERE (in compressors) 24 2000 5 yrs/5000 hrs using OEM fluids and filters
with $250 deductible
(in generators as of 1/1/01) 24 2000 2 yrs/4000 hrs using IR fluids and filters
DEUTZ 24 2000 Available at dealer
INGERSOLLRAND 24 4000 5 yrs/10,000 hrs when using genuine Inger-
sollRand fluids and parts. Refer to operators
manual.
KUBOTA (North America only) 24 2000 Major components 36 mo/3000 hrs (parts only)
(Western Europe & Oceania) 24 2000 None
(Central & South America, Asia, Middle East &
Africa)
12 1000 None
MITSUBISHI 24 2000 2 yrs/4000 hrs using IR fluids and filters
VOLVO 24 2000 2 yrs/4000 hrs using IR fluids and filters
HONDA 12 unlimited None
VANGUARD 24 unlimited None
5
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
PARTS
Months Hours Coverage
IngersollRand
6 No Limit Parts Only
AIREND EXCHANGE
Months Hours Extended Coverage
Airend
12 2000 2 yrs/4000 hrs available from
IR.
Note: Actual warranty times may change. Consult the manufacturers warranty policy as shipped with
each new product.
6
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
Extended Limited Airend Warranty
IngersollRand Portable Compressor Division is pleased to announce the availability of extended limited airend warranty.
Announcement of the extended warranty coincides with the introduction of ProTe c Compressor Fluid. ProTe c Compressor Fluid
is an amber coloured fluid specially formulated for Portable Compressors and is being provided as the factory filled fluid for all machines
except
1
XHP650/900/1070
All machines have the standard airend warranty, The earlier of 24 months from shipment to, or the accumulation of 4000 hours of
service by the initial user.
The warranty against defects will include replacement of the complete Airend, provided the original Airend is returned assembled and
unopened.
The optional limited warranty is the earlier of 60 months from shipment to, or the accumulation of 10,000 hours of service. The optional
warranty is limited to defects in major components (rotors, housings, gears and bearings), and is automatically available when the
following conditions are met:
1. The original airend is returned assembled and unopened.
2. Submissions of proof that IngersollRand fluid, filters and separators have been used. Refer to the Operation and Parts manual for
the correct fluids, filters and separator elements required.
3. Submissions of proof that maintenance intervals have been followed.
WARRANTY TIME *BARE AIREND **AIREND COMPONENTS
STANDARD 2YRS / 4,000HRS 100% PARTS & LABOUR 100% PARTS & LABOUR
OPTIONAL 5YRS / 10,000HRS 100% PARTS & LABOUR 0%
*BARE AIREND pertains to major airend parts (rotors, housings, gears and bearings).
**AIREND COMPONENTS pertains to auxiliary attachments to the bare airend (seals, pumps, valves, tubes, hoses, fittings and filter
housing).
ProTec and XHP505 Compressor Fluids are available from your local IngersollRand branch or distributor.
For units operating within the USA & Canada, call the Mocksville Product Support Department on 18006335206
1
XHP650/900/1070 will continue to use XHP505 and will have the extended warranty when above conditions are met.
7
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
WARRANTY REGISTRATION
FOR UNITS SOURCED FROM HINDLEY GREEN, UK
Complete Machine Registration
To initiate the machine warranty, fill out the Warranty Registration form 83242 11/99 supplied as part of the machine documentation,
keep a copy for your records and mail the original to:
Ingersoll Rand European Sales Ltd
Portable Power Business
Swan Lane
Hindley Green
Wigan
Lancashire
WN2 4EZ
U.K.
Attn: Customer Service Department
Note: Completion of this form validates the warranty.
Engine Registration:
IR powered machines do not require separate engine registration.
Deutz require a separate engine registration form to be completed and mailed direct to their Cologne office. The form is supplied as part
of the machine documentation for Deutz powered machines.
Caterpillar, Cummins and Perkins do not require a separate registration form but they stipulate that any new engine should be registered
with their local dealer to initiate warranty.
You MUST provide proof of the inservice date when requesting engine warranty repairs.
8
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
Selling Distributor Servicing Distributor
WARRANTY REGISTRATION
Name Name Owner/User Name
Address Address Address
City City City
County County County
State State State
Zip code Zip code Zip code
Telephone Telephone Telephone
Complete the Applicable Blocks
Owner/User Type of Business (check one only)
ConstructionHeavy
(highway, excavation, etc.)
Asphalt Contractor Coal Mining Other Mining
ConstructionLight
(carpentry, plumbing, pools,
mason, etc.)
Government
(municipal, state,
county, etc.)
Quarry Shallow Oil &
Gas
Rental (rental center, rental
fleet, etc.)
Building Contractor Water well Utility
Company
(gas, electric,
water, etc.)
Industrial
(plant use)
Other
specify
Exploration Utility
Contractor
Model S/N Unit S/N Engine S/N Date delivered
UnitHours Airend S/N Truck S/N Truck Engine S/N
SERVICING DISTRIBUTOR / USER ACKNOWLEDGEMENT
1. The Purchaser has been instructed and/or has read the manual and understands proper preventative
maintenance, general operation and safety precautions.
2. The warranty and limitation of liability has been reviewed and understood by the owner/user.
3. In the event that this unit is to be used within a nuclear facility, the owner/user shall notify
IngersollRand of such use so that IngersollRand may arrange for appropriate nuclear liability
protection from the ownerlicensee of the facility.
4. IngersollRand reserves the right to make design changes or modifications of IngersollRand products
at anytime without incurring any obligation to make similar changes or modifications on previously sold
units.
9
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
DECALS
Look for these signs on machines manufactured in Europe, which point out potential hazards to
the safety of you and others. Read and understand thoroughly. Heed warnings and follow
instructions. If you do not understand, inform you supervisor.
GRAPHIC FORM AND MEANING OF ISO SYMBOLS
Prohibition / Mandatory Information / Instructions Warning
WARNING: Electrical shock risk. WARNING Pressurised component or
system.
WARNING Hot surface.
WARNING Pressure control. WARNING Corrosion risk.
WARNING Air/gas flow or Air
discharge.
X,XBAR
WARNING Pressurised vessel.
WARNING Hot and harmful exhaust
gas.
WARNING Maintain correct tyre
pressure. (Refer to the GENERAL
INFORMATION section of this manual).
10
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
0C
WARNING Flammable liquid.
WARNING Before connecting the tow
bar or commencing to tow consult the
operation and maintenance manual.
WARNING For operating temperature
below 0C, consult the operation and
maintenance manual.
WARNING Do not undertake any
maintenance on this machine until the
electrical supply is disconnected and
the air pressure is totally relieved.
WARNING Consult the operation and
maintenance manual before
commencing any maintenance.
Do not breathe the compressed air from
this machine.
Do not remove the Operating and
Maintenance manual and manual holder
from this machine.
Do not stack.
Do not operate the machine without the
guard being fitted.
11
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
Do not stand on any service valve or other
parts of the pressure system.
Do not operate with the doors or enclosure
open.
Do not use fork lift truck from this side.
XX
km/h
Do not exceed the trailer speed limit. No naked lights.
Do not open the service valve before the
airhose is attached.
Use fork lift truck from this side only. Emergency stop. Tie down point
Lifting point. On (power). Off (power).
Read the Operation and Maintenance
manual before operation or maintenance
of this machine is undertaken.
When parking use prop stand, handrake
and wheel chocks.
Compressor oil filling
Diesel fuel
No open flame.
Parking brake.
Rough Service Designation.
Wet Location Operation.
12
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
Replace any cracked protective shield.
Oil drain. Engine Oil
Fuel level/point Pressure control Malfunction
Battery charging condition Low pressure High pressure
Engine malfunction
High compressor temperature
Compressor malfunction
Low engine oil pressure
Engine high temperature
13
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
SAFETY
WARNINGS
Warnings call attention to instructions which must be
followed precisely to avoid injury or death.
CAUTIONS
Cautions call attention to instructions which must be
followed precisely to avoid damaging the product, process or its
surroundings.
NOTES
Notes are used for supplementary information.
General Information
Never operate unit without first observing all safety warnings
and carefully reading the operation and maintenance manual
shipped from the factory with this machine.
Ensure that the operator reads and understands the decals
and consults the manuals before maintenance or operation.
Ensure that the Operation and Maintenance manual, and the
manual holder, are not removed permanently from the machine.
Ensure that maintenance personnel are adequately trained,
competent and have read the Maintenance Manuals.
Make sure that all protective covers are in place and that the
canopy/doors are closed during operation.
The specification of this machine is such that the machine is
not suitable for use in flammable gas risk areas. If such an
application is required then all local regulations, codes of
practice and site rules must be observed. To ensure that the
machine can operate in a safe and reliable manner, additional
equipment such as gas detection, exhaust spark arrestors, and
intake (shutoff) valves may be required, dependant on local
regulations or the degree of risk involved.
A weekly visual check must be made on all fasteners/fixing
screws securing mechanical parts. In particular, safetyrelated
parts such as coupling hitch, drawbar components,
roadwheels, and lifting bail should be checked for total
security.
All components which are loose, damaged or unserviceable,
must be rectified without delay.
Air discharged from this machine may contain carbon
monoxide or other contaminants which will cause serious injury
or death. Do not breathe this air.
This machine produces loud noise with the doors open or
service valve vented. Extended exposure to loud noise can
cause hearing loss. Always wear hearing protection when doors
are open or service valve is vented.
Never inspect or service unit without first disconnecting
battery cable(s) to prevent accidental starting.
Do not use petroleum products (solvents or fuels) under high
pressure as this can penetrate the skin and result in serious
illness. wear eye protection while cleaning unit with compressed
air to prevent debris from injuring eye(s).
Rotating fan blade can cause serious injury. Do not operate
without guard in place.
Use care to avoid contacting hot surfaces (engine exhaust
manifold and piping, air receiver and air discharge piping, etc.).
Ether is an extremely volatile, highly inflammable gas. When
it is specified as a starting aid, use sparingly. DO NOT USE
ETHER IF THE MACHINE HAS GLOW PLUGS OR INLET
HEATER STARTING AIDS OR ENGINE DAMAGE WILL
RESULT.
Never operate unit with guards, covers or screens removed.
Keep hands, hair, clothing, tools, blow gun tips, etc. well away
from moving parts.
Compressed air
Compressed air can be dangerous if incorrectly handled.
Before doing any work on the unit, ensure that all pressure is
vented from the system and that the machine cannot be started
accidentally.
Ensure that the machine is operating at the rated pressure
and that the rated pressure is known to all relevant personnel.
All air pressure equipment installed in or connected to the
machine must have safe working pressure ratings of at least the
machine rated pressure.
If more than one compressor is connected to one common
downstream plant, effective check valves and isolation valves
must be fitted and controlled by work procedures, so that one
machine cannot accidently be pressurised / over pressurised by
another.
Compressed air must not be used for a direct feed to any
form of breathing apparatus or mask.
High Pressure Air can cause serious injury or death. Relieve
pressure before removing filler plugs/caps, fittings or covers.
Air pressure can remain trapped in air supply line which can
result in serious injury or death. Always carefully vent air supply
line at tool or vent valve before performing any service.
The discharged air contains a very small percentage of
compressor lubricating oil and care should be taken to ensure
that downstream equipment is compatible.
If the discharged air is to be ultimately released into a
confined space, adequate ventilation must be provided.
When using compressed air always use appropriate
personal protective equipment.
All pressure containing parts, especially flexible hoses and
their couplings, must be regularly inspected, be free from
defects and be replaced according to the Manual instructions.
Avoid bodily contact with compressed air.
The safety valve located in the separator tank must be
checked periodically for correct operation.
14
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
Whenever the machine is stopped, air will flow back into the
compressor system from devices or systems downstream of
the machine unless the service valve is closed. Install a check
valve at the machine service valve to prevent reverse flow in the
event of an unexpected shutdown when the service valve is
open.
Disconnected air hoses whip and can cause serious injury
or death. Always attach a safety flow restrictor to each hose at
the source of supply or branch line in accordance with OSHA
Regulation 29CFR Section 1926.302(b).
Never allow the unit to sit stopped with pressure in the
receiverseparator system.
Materials
The following substances may be produced during the
operation of this machine:
. brake lining dust
. engine exhaust fumes
AVOID INHALATION
Ensure that adequate ventilation of the cooling system and
exhaust gases is maintained at all times.
The following substances are used in the manufacture of this
machine and may be hazardous to health if used incorrectly:
. antifreeze
. compressor lubricant
. engine lubricant
. preservative grease
. rust preventative
. diesel fuel
. battery electrolyte
AVOID INGESTION, SKIN CONTACT AND INHALATION OF
FUMES
Should compressor lubricant come into contact with the
eyes, then irrigate with water for at least 5 minutes.
Should compressor lubricant come into contact with the
skin, then wash off immediately.
Consult a physician if large amounts of compressor lubricant
are ingested.
Consult a physician if compressor lubricant is inhaled.
Never give fluids or induce vomiting if the patient is
unconscious or having convulsions.
Safety data sheets for compressor and engine lubricants
should be obtained from the lubricant supplier.
Never operate the engine of this machine inside a building
without adequate ventilation. Avoid breathing exhaust fumes
when working on or near the machine.
This machine may include such materials as oil, diesel fuel,
antifreeze, brake fluid, oil/air filters and batteries which may
require proper disposal when performing maintenance and
service tasks. Contact local authorities for proper disposal of
these materials.
Battery
A battery contains sulphuric acid and can give off gases
which are corrosive and potentially explosive. Avoid contact
with skin, eyes and clothing. In case of contact, flush area
immediately with water.
DO NOT ATTEMPT TO SLAVE START A FROZEN BATTERY
SINCE THIS MAY CAUSE IT TO EXPLODE.
Exercise extreme caution when using booster battery. To
jump battery, connect ends of one booster cable to the positive
(+) terminal of each battery. Connect one end of other cable to
the negative () terminal of the booster battery and other end to
a ground connection away from dead battery (to avoid a spark
occurring near any explosive gases that may be present). After
starting unit, always disconnect cables in reverse order.
Radiator
Hot engine coolant and steam can cause injury. Ensure that
the radiator filler cap is removed with due care and attention.
Do not remove the pressure cap from a HOT radiator. Allow
radiator to cool down before removing pressure cap.
Transport
When loading or transporting machines ensure that the
specified lifting and tie down points are used.
When loading or transporting machines ensure that the
towing vehicle, its size, weight, towing hitch and electrical
supply are all suitable to provide safe and stable towing at
speeds either, up to the legal maximum for the country in which
it is being towed or, as specified for the machine model if lower
than the legal maximum.
Ensure that the maximum trailer weight does not exceed the
maximum gross weight of the machine (by limiting the
equipment load), limited by the capacity of the running gear.
Note:
Gross mass (on data plate) is for the basic machine and fuel
only, excluding any fitted options, tools, equipment and foreign
materials.
Before towing the machine, ensure that:
. the tyres and towing hitch are in a serviceable condition.
. the canopy is secure.
. all ancillary equipment is stored in a safe and secure manner.
. the brakes and lights are functioning correctly and meet
necessary
road traffic requirements.
. break-away cables/safety chains are connected to the
towing
vehicle.
The machine must be towed in a level attitude in order to
maintain correct handling, braking and lighting functions. This
can be achieved by correct selection and adjustment of the
vehicle towing hitch and, on variable height running gear,
adjustment of the drawbar.
To ensure full braking efficiency, the front (towing eye)
section must always be set level.
When adjusting variable height running gear:
15
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
Ensure front (towing eye) section is set level
When raising towing eye, set rear joint first, then front joint.
When lowering towing eye, set front joint first, then rear joint.
After setting, fully tighten each joint by hand and then tighten fur-
ther to the next pin. Refit the pin.
When parking always use the handbrake and, if necessary,
suitable wheel chocks.
Make sure wheels, tyres and tow bar connectors are in safe
operating condition and tow bar is properly connected before
towing.
Safety chains / connections and their adjustment
The legal requirements for the joint operation of the
breakaway cable and safety chains are as yet unidentified by
71/320/EEC or UK regulations. Consequently we offer the
following advice / instructions.
Where brakes only are fitted:
a) Ensure that the breakaway cable is securely coupled to the
handbrake lever and also to a substantial point on the towing
vehicle.
b) Ensure that the effective cable length is as short as possible,
whilst still allowing enough slackness for the trailer to articulate
without the handbrake being applied.
Where brakes and safety chains are fitted:
a) Loop the chains onto the towing vehicle using the towing
vehicle hitch as an anchorage point, or any other point of similar
strength.
b) Ensure that the effective chain length is as short as possible
whilst still allowing normal articulation of the trailer and effective
operation of the breakaway cable.
Where safety chains only are fitted:
a) Loop the chains onto the towing vehicle using the towing
vehicle hitch as an anchorage point, or any other point of similar
strength.
b) When adjusting the safety chains there should be sufficient
free length in the chains to allow normal articulation, whilst also
being short enough to prevent the towbar from touching the
ground in the event of an accidental separation of the towing
vehicle from the trailer.
16
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
MANUFACTURED IN EUROPE
FRONT VIEW
SIDE VIEW
REAR VIEW
TOP VIEW
7/120 9/110 10/105 14/85
P425AWIR XP375AWIR HP375AWIR
VHP300AWIR
All dimensions in inches(mm)
A Instrument panel access door
B Package air inlet
C Access items:
Separator element & fill
Compressor oil filter
Fuel filters
Dipstick
Engine oil fill
Coolant bottle fill
D Access items:
Fuel fill
Engine oil filter
Fuel filter
Engine and compressor air filter
E Access items:
Radiator fill
F Package air outlet
G Track width
H Variable height drawbar
162 (4114) minimum / 168 (4277) maximum
J Variable height drawbar
17 (420) minimum / 35 (880) maximum
17
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
MANUFACTURED IN EUROPE
FRONT VIEW
SIDE VIEW
REAR VIEW
TOP VIEW
7/170 10/125 14/115
P600WIR HP450WIR VHP400WIR
All dimensions in inches(mm)
A Instrument panel access door
B Package air inlet
C Access items:
Separator element & fill
Compressor oil filter
Fuel filters
Dipstick
Engine oil fill
Coolant bottle fill
D Access items:
Fuel fill
Engine oil filter
Fuel filter
Engine and compressor air filter
E Access items:
Radiator fill
F Package air outlet
G Track width
H Variable height drawbar
184.29 (4681) minimum / 189.21 (4806) maximum
J Variable height drawbar
18.98 (482) minimum / 37.17 (944) maximum
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Ingersoll-Rand 14/85 User manual

Category
Power supply units
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI