ADJ 15 HEX BAR IP is a multi-colored, IP65-rated LED wash fixture with electronic dimming, DMX-512 protocol, and locking 5-pin XLR connections. It offers 10 DMX channel modes, allowing for various lighting effects and programming options. The unit can operate in standalone mode or be set up in a master/slave configuration for synchronized shows. It features multiple unit power linking capabilities and includes a removable frost/diffuser filter and glare shield for customizing the light output.

ADJ 15 HEX BAR IP is a multi-colored, IP65-rated LED wash fixture with electronic dimming, DMX-512 protocol, and locking 5-pin XLR connections. It offers 10 DMX channel modes, allowing for various lighting effects and programming options. The unit can operate in standalone mode or be set up in a master/slave configuration for synchronized shows. It features multiple unit power linking capabilities and includes a removable frost/diffuser filter and glare shield for customizing the light output.

User Instructions
15 HEX BAR IP
Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical prod-
ucts when they are not in use. To avoid power consumption in idle mode, disconnect all electrical
equipment from power when not in use. Thank you!
©2019 ADJ Products, LLC all rights reserved. Information, specications, diagrams, images, and
instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying
product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection
claimed includes all forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this document may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of
their respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic
loss associated with the use or reliance of any information contained within this document, and/or as
a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation
of this product.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installa
-
tion. This device uses and can radiate radio frequency energy and, if not installed and used in accordance
with the included instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by turning the device off and on, the
user is encouraged to try to correct the interference by one or more of the following methods:
· Reorient or relocate the device.
· Increase the separation between the device and the receiver.
· Connect the device to an electrical outlet on a circuit different from which the radio receiver is
connected.
· Consult the dealer or an experienced radio/TV technician for help.
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document
may be available online.
Please check www.adj.com for the latest revision/update of this manual before beginning
installation and/or programming.
06/10/19
1 1.02
6/9/12/14/17/
30/33/38/41/60
Initial Version
Date
Document
Version
Software
Version >
DMX Channel
Modes
Notes
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 2
15 Hex Bar IP Table of Contents
Introduction
Features I Warranty Registration I Installation
Safety Precautions
IP65 Notice
Overview I Installation
Manual Tilt Adjustment I Connections
DMX Set Up
DMX Addressing
DMX Modes & Values
Color Macro Chart
System Menu
Master-Slave Set Up
Pixel Zones
Dimmer Curve Chart
Glare Shield Installation I Filter Installation
Dimensional Drawings
Power Linking I Trouble Shooting I Cleaning
Limited Warranty (USA Only)
Specications
3
4
5
7
8
10
11
12
13
17
18
22
23
24
25
26
27
28
29
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 3
15 Hex Bar IP Introduction
Unpacking: Thank you for purchasing the 15 Hex Bar IP by ADJ Products, LLC. Every unit has been
thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping
carton for damage that may have occurred during shipping. If the carton appears to be damaged,
carefully inspect your xture for any damage and be sure all accessories necessary to operate the unit
has arrived intact. In the case damage has been found or parts are missing, please contact our toll free
customer support number for further instructions. Do not return this unit to your dealer without rst
contacting customer support.
Introduction: The 15 Hex Bar IP is a DMX intelligent, IP rated LED wash fixture. This xture can be
used in a stand alone mode or connected in a Master/Slave conguration.
This product is intended to be used by professionally trained personnel only and is not suitable for
private use.
Customer Support: Contact ADJ Service for any product related service and support needs. Also visit
forums.adj.com with questions, comments or suggestions.
Parts: To purchase parts online visit http://parts.americandj.com
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
Voice: 800-322-6337 | Fax: 323-582-2941 | [email protected]
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | [email protected]
ADJ PRODUCTS LLC USA
6122 S. Eastern Ave. Los Angeles, CA. 90040
323-582-2650 | Fax 323-532-2941 | www.adj.com | info@adj.com
ADJ SUPPLY Europe B.V
Junostraat 2 6468 EW Kerkrade, The Netherlands
+31 (0)45 546 85 00 | Fax +31 45 546 85 99
www.adj.eu | [email protected]
ADJ PRODUCTS GROUP Mexico
AV Santa Ana 30 Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself,
doing so will void your manufactures warranty. In the unlikely event your unit may require service
please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
15 Hex Bar IP Features
15 Hex Bar IP Warranty Registration
The 15 Hex Bar IP carries a 2 year limited warranty. Please fill out the enclosed warranty card to
validate your purchase. All returned service items whether under warranty or not, must be freight pre-
paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on
the outside of the return package. A brief description of the problem as well as the R.A. number must
also be written down on a piece of paper included in the shipping carton. If the unit is under warranty,
you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by con-
tacting our customer support team on our customer support number. All packages returned to the
service department not displaying a R.A. number on the outside of the package will be returned to the
shipper.
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 4
Multi-Colors
Five Operating Modes
Electronic Dimming 0-100%
DMX-512 protocol
IP65 Locking 5-Pin XLR Connections In/Out
10 DMX Channel Modes: 6 / 9 / 12 / 14 / 17 / 30 / 33 / 38 / 41 / 60
Multiple Unit Power Linking (See page 27)
Included:
1 x IP65 Locking Power Cable
1 x Removable Frost/Diffuser Filter
1 x Removable Glare Shield
2 x Omega Brackets
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 5
15 Hex Bar IP Safety Precautions
Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to
remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk
of electrical shock and re in case of an internal short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user serviceable parts inside.
Never operate this unit when it’s cover is removed.
Never plug this unit in to a dimmer pack
Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6”
(15cm) between this device and a wall.
Do not attempt to operate this unit, if it becomes damaged.
During long periods of non-use, disconnect the unit’s main power.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to be walked on or pinched by
items placed upon or against them, paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 27
for cleaning details.
Heat -The appliance should be situated away from heat sources such as radiators, heat registers,
stoves, or other appliances (including amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the fixture.
C. The fixture does not appear to operate normally or exhibits a marked change in performance.
D. The fixture has fallen and/or subjected to extreme handling.
15 Hex Bar IP Safety Precautions
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION!
FIXTURE EMITS HIGH INTENSITY ULTRAVIOLET (UV) LIGHT FROM THE UV LED.
WEAR PROPER EYE AND SKIN PROTECTION.
AVOID PROLONGED PERIODS OF EXPOSURE TO THE UV LED.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN.
AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m).
DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER.
DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW (UV) LIGHT DIRECTLY WITH
OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT.
INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE
DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE
DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE.
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 6
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 7
15 Hex Bar IP IP65 Notice
IP65 RATED
An IP rated lighting xture is one, which is commonly installed in outdoor environments
and has been designed with an enclosure that eectively protects the ingress (entry)
of external foreign objects such as dust and water. The International Protection (IP)
rating system is commonly expressed as "IP" (Ingress Protection) followed by two
numbers (i.e. IP65) where the numbers dene the degree of protection. The rst digit
(Foreign Bodies Protection) indicates the extent of protection against particles entering
the xture and the second digit (Water Protection) indicates the extent of protection
against water entering the xture. An IP65 rated lighting xture is one, which has been
designed and tested to protect against the ingress of dust (6) and low-pressure water
jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS
NOT suitable for marine and/or coastal environment installations. Installing
this xture in a marine and/or coastal environment may cause corrosion and/
or excessive wear to the interior and/or exterior components of the xture.
Damages and/or performance issues resulting from installation in a marine
and/or coastal environment will void the manufactures warranty and will NOT be subJect
to any warranty claims and/or repairs.
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 8
15 Hex Bar IP Installation
Always ensure that the unit is rmly xed to avoid vibration and slipping while operating. Always
ensure that the structure to which you are attaching the unit is secure and is able to support a weight
of 10 times the unit’s weight. ALWAYS use safety cables that can hold 12 times the weight of the
unit when installing the xture.
This equipment must be installed by a professional, and it must be installed in a place where it is out
of the reach of people’s grasp. Overhead mounting requires extensive experience, including calculat-
ing working load limits, installation material being used, and perodic safety inspection of all installa-
tion material and unit. If you lack these qualications, do not attempt the installation yourself. These
installaiton should be checked by a skilled person once a year.
Ensure ALL connections and end caps are properly sealed with a non-conductive dielectric
grease (available at most electrical suppliers) to prevent water ingress/condensation and/or
corrosion.
The 15 Hex Bar IP is fully operational in three dierent mounting positions; hanging upside-down,
mounted sideways on trussing, or set on a at level surface. Be sure this xture is kept at least 12m
(40ft) away from any ammable materials (decoration etc.). ALWAYS use and install the supplied
safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp
fails.
Screw one clamp via a M12 screw and nut into the Omega holder. Insert the quick-lock fasteners of
the Omega holder into the respective holes of the adjustable mounting bracket. Tighten the quick-
lock fasteners fully clockwise. Pull the safety-cable through the attachment openings and over the
trussing system or a safe xation spot. Insert the end in the carabine and tighten the safety screw.
PLEASE SEE THE NEXT PAGE FOR CLAMP AND SAFETY CABLE INSTALL.
15 Hex Bar IP Overview
LCD Screen
Mode Button
Up Button
Down Button
Enter Button
IP65 5-Pin XLR Connection In
IP65 5-Pin XLR Connection Out
IP65 Locking Power
Connection In
IP65 Locking Power
Connection Out
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 9
15 Hex Bar IP Installation
1. Attach a clamp (not included)
to each omega bracket.
2. Attach the omega brackets
to the bracket mounts located on
the 15 Hex Bar IP brackets.
3. Turn the quick-lock
fastners fully clockwise to lock
the Omega brackets into place.
4. Attach safety cables (not included)
to both safety cable attachment points.
NOTE: Safety cable attachment points are located
at both ends. Its recommended to use safety
cables on both ends.
ALWAYS ATTACH A SAFETY CABLE WHENEVER
INSTALLING THIS DEVICE IN A SUSPENEDED
ENVIRONMENT TO ENSURE THE FIXTURE WILL
NOT DROP IF THE CLAMP FAILS.
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 10
15 Hex Bar IP Connections
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC
GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION
AND/OR ELECTRICAL SHORT CIRCUIT.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE,
ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED.
15 Hex Bar IP Manual Tilt Adjustment
The bar angle is adjustable manually using the brackets located on each side
of the unit. Simply loosen the tilt adjustment knobs attached to each mounting
bracket and adjust the bracket accordingly. After making your desired set up,
securely tighten the tilt adjustment knobs. See picture below for a 90 degree set
up.
90 Degree Setting
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 11
15 Hex Bar IP DMX Set Up
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication
between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from
the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the
DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a
DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be
linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use
the shortest cable path possible. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed
anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that
unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The 15 Hex Bar IP can be controlled
via DMX-512 protocol. The 15 Hex Bar IP has 10 DMX channel modes. The DMX address is set on the
back panel of the 15 Hex Bar IP. Your unit and your DMX controller require a standard 5-pin XLR connec-
tor for data input and data output. We recommend Accu-Cable DMX cables. If you are making your own
cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all
pro lighting stores). Your cables should be made with a male and female XLR connector on either end
of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Special Note: Line Termination.
When longer runs of cable are used, you may need to use a terminator
on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected
between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female
XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ
part number Z-DMX/T) will decrease the possibilities of erratic behavior.
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 12
All xtures should be given a DMX starting address when using a DMX controller, so the correct xture
responds to the correct control signal. This digital starting address is the channel number from which
the xture starts to “listen” to the digital control signal sent out from the DMX controller. The assignment
of this starting DMX address is achieved by setting the correct DMX address on the digital control
display on the xture.
You can set the same starting address for all xtures or a group of xtures, or set dierent addresses
for each individual xture. Setting all xtures to the same DMX address will cause all xtures to react
in the same way, in other words, changing the settings of one channel will aect all the xtures
simultaneously.
If you set each xture to a dierent DMX address, each unit will start to “listen” to the channel number
you have set, based on the quantity of DMX channels of each xture. That means changing the settings
of one channel will only aect the selected xture.
In the case of the 15 Hex Bar IP, when in 6 channel mode you should set the starting DMX address of
the rst unit to 1, the second unit to 7 (6 + 1), the third unit to 13 (7 + 6), and so on. (See chart below
for more details.)
15 Hex Bar IP DMX Addressing
Channel Mode
Unit1
Address
Unit2
Address
Unit3
Address
Unit4
Address
6 Channels 1 7 13 19
9 Channels 1 10 19 28
12 Channels 1 13 25 37
14 Channels 1
15 29
43
17 Channels 1
18 35
52
33 Channels 1
34 67
100
30 Channels 1
31 61
91
41 Channels 1
42 83
124
38 Channels 1
39 77
115
60 Channels 1
61 121
181
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 13
15 Hex Bar IP DMX Modes & Values
VALUES FUNCTIONS
RED FINE (ZONE #1)
GREEN FINE (ZONE #1)
BLUE FINE (ZONE #1)
WHITE FINE (ZONE #1)
AMBER FINE (ZONE #1)
UV FINE (ZONE #1)
RED FINE (ZONE #2)
GREEN FINE (ZONE #2)
BLUE FINE (ZONE #2)
1
2
3
4
5
6
6 Ch 9 Ch 12 Ch 14 Ch 17 Ch 33 Ch
000-255
RED (ALL LEDS)
0-100%
000-255
GREEN (ALL LEDS)
0-100%
000-255
BLUE (ALL LEDS)
0-100%
000-255
WHITE (ALL LEDS)
0-100%
000-255
AMBER (ALL LEDS)
0-100%
000-255
UV (ALL LEDS)
0-100%
000-255
RED (ZONE #1)
0-100%
000-255
GREEN (ZONE #1)
0-100%
000-255
BLUE (ZONE #1)
0-100%
000-255
WHITE (ZONE #1)
0-100%
000-255
AMBER (ZONE #1)
0-100%
000-255
UV (ZONE #1)
0-100%
000-255
RED (ZONE #2)
0-100%
000-255
GREEN (ZONE #2)
0-100%
000-255
BLUE (ZONE #2)
0-100%
30 Ch
38 Ch 60 Ch41 Ch
RED FINE (ALL LEDS)000-255
GREEN FINE (ALL LEDS)000-255
BLUE FINE (ALL LEDS)000-255
WHITE FINE (ALL LEDS)000-255
AMBER FINE (ALL LEDS)000-255
UV FINE (ALL LEDS)000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
3
5
7
9
11
2
4
6
8
10
12
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
7
8
9
7
8
9
7
8
9
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 14
15 Hex Bar IP DMX Modes & Values
VALUES FUNCTIONS
WHITE FINE (ZONE #3)
AMBER FINE (ZONE #3)
UV FINE (ZONE #3)
RED FINE (ZONE #4)
GREEN FINE (ZONE #4)
BLUE FINE (ZONE #4)
WHITE FINE (ZONE #4)
AMBER FINE (ZONE #4)
UV FINE (ZONE #4)
6 Ch 9 Ch 12 Ch 14 Ch 17 Ch 33 Ch
000-255
WHITE (ZONE #2)
0-100%
000-255
AMBER (ZONE #2)
0-100%
000-255
UV (ZONE #2)
0-100%
000-255
RED (ZONE #3)
0-100%
000-255
GREEN (ZONE #3)
0-100%
000-255
BLUE (ZONE #3)
0-100%
000-255
WHITE (ZONE #3)
0-100%
000-255
AMBER (ZONE #3)
0-100%
000-255
UV (ZONE #3)
0-100%
000-255
RED (ZONE #4)
0-100%
000-255
GREEN (ZONE #4)
0-100%
000-255
BLUE (ZONE #4)
0-100%
000-255
WHITE (ZONE #4)
0-100%
000-255
AMBER (ZONE #4)
0-100%
000-255
UV (ZONE #4)
0-100%
30 Ch
38 Ch 60 Ch41 Ch
WHITE FINE (ZONE #2)000-255
AMBER FINE (ZONE #2)000-255
UV FINE (ZONE #2)000-255
RED FINE (ZONE #3)000-255
GREEN FINE (ZONE #3)000-255
BLUE FINE (ZONE #3)000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
31
33
35
37
39
41
43
45
47
32
34
36
38
40
42
44
46
48
19
20
21
22
23
24
25
26
27
28
29
30
16
17
18
19
20
21
22
23
24
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
10
11
12
13
14
15
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 15
15 Hex Bar IP DMX Modes & Values
VALUES FUNCTIONS6 Ch 9 Ch 12 Ch 14 Ch 17 Ch 33 Ch
000-255
RED (ZONE #5)
0-100%
000-255
GREEN (ZONE #5)
0-100%
000-255
BLUE (ZONE #5)
0-100%
000-255
WHITE (ZONE #5)
0-100%
000-255
AMBER (ZONE #5)
0-100%
000-255
UV (ZONE #5)
0-100%
30 Ch
38 Ch 60 Ch41 Ch
RED FINE (ZONE #5)000-255
GREEN FINE (ZONE #5)000-255
BLUE FINE (ZONE #5)000-255
WHITE FINE (ZONE #5)000-255
AMBER FINE (ZONE #5)000-255
UV FINE (ZONE #5)000-255
000-031
032-063
064-095
096-127
128-159
160-191
192-223
224-255
49
50
51
52
53
54
55
56
57
58
59
60
25
26
27
28
29
30
25
26
27
28
29
30
25
26
27
28
29
30
25
26
27
28
29
30
COLOR MACROS
See Color Macro Chart on page 16
000-255
COLOR TEMPERATURES
2700-7000K
000-255
SHUTTER & STROBE
LEDs Off
LEDs On
Strobing Slow - Fast
LEDs On
Pulse Strobing in Sequences
LEDs On
Random Strobing Slow - Fast
LEDs On
MASTER DIMMER
0% - 100%
000-255
DIMMER FINE
0% - 100%
000-255
7 7 3131
8 8 3232
9 9 3333317
10 10 3434328
11 11 3535339
000-010
011-026
027-043
044-060
061-076
077-093
094-110
111-126
127-143
144-160
161-176
177-193
194-210
211-226
227-255
AUTO PROGRAMS
Off
Auto Program 1
Auto Program 2
Auto Program 3
Auto Program 4
Auto Program 5
Auto Program 6
Auto Program 7
Auto Program 8
Auto Program 9
Auto Program 10
Auto Program 11
Auto Program 12
Auto Program 13
No Function
12 36
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 16
15 Hex Bar IP DMX Modes & Values
VALUES FUNCTIONS6 Ch 9 Ch 12 Ch 14 Ch 17 Ch 33 Ch30 Ch
38 Ch 60 Ch41 Ch
000-255
AUTO PROGRAM SPEED
Slow - Fast
000-255
AUTO PROGRAM FADE
Slow - Fast
13 37
14 38
DIMMER MODES
Standard
Stage
TV
Architectural
Theatre
Stage 2
DIMMER DELAY TIME
0.1Sec.
0.2Sec.
0.3Sec.
0.4Sec.
0.5Sec.
0.6Sec.
0.7Sec.
0.8Sec.
0.9Sec.
1.0Sec.
1.5Sec.
2.0Sec.
3.0Sec.
4.0Sec.
5.0Sec.
6.0Sec.
7.0Sec.
8.0Sec.
9.0Sec.
10Sec.
Default to Unit Setting
000-020
021-040
041-060
061-080
081-100
101-120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141-255
REFRESH RATES
Default to Unit Setting
900Hz
1000Hz
1100Hz
1200Hz
1300Hz
1400Hz
1500Hz
2500Hz
4000Hz
5000Hz
10000Hz
15000Hz
20000Hz
25000Hz
No Function
000-015
016-030
031-045
046-060
061-075
076-090
091-105
106-120
121-135
136-150
151-165
166-180
181-195
196-210
211-225
226-255
GAMMA
Default to Unit Setting
2.0
2.2
2.4
2.6
2.8
No Function
000-020
021-040
041-060
061-080
081-100
101-120
121-255
15 3912 36
16 4013 37
17 4114 38
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 17
15 Hex Bar IP Color Macro Chart
0-3=Off 64-67=B+W 128-131=G+B+W 192-195=R+B+W+A
4-7=Red 68-71=B+A 132-135=G+B+A 196-199=R+B+W+UV
8-11=Green 72-75=B+UV 136-139=G+B+UV 200-203=R+B+A+UV
12-15=Blue 76-79=W+A 140-143=G+W+A 204-207=R+W+A+UV
16-19=White 80-83=W+UV 144-147=G+W+UV 208-211=G+B+W+A
20-23=Amber 84-87=A+UV 148-151=G+A+UV 212-215=G+B+W+UV
24-27=UV 88-91=R+G+B 152-155=B+W+A 216-219=G+B+A+UV
28-31=R+G 92-95=R+G+W 156-159=B+W+UV 220-223=G+W+A+UV
32-35=R+B 96-99=R+G+A 160-163=B+A+UV 224-227=B+W+A+UV
36-39=R+W 100-103=R+G+UV 164-167=W+A+UV 228-231=R+G+B+W+A
40-43=R+A 104-107=R+B+W 168-171=R+G+B+W 232-235=R+G+B+W+UV
44-47=R+UV 108-111=R+B+A 172-175=R+G+B+A 236-239=R+G+B+A+UV
48-51
=G+B 112-115=R+B+UV 176-179=R+G+B+UV 240-243=R+G+W+A+UV
52-55=G+W 116-119=R+W+A 180-183=R+G+W+A 244-247=R+B+W+A=UV
56-59=G+A 120-123=R+W+UV 184-187=R+G+W+UV 248-251=G+B+W+A+UV
60-63=G+UV 124-127=R+A+UV 188-191=R+G+A+UV 252-255=R+G+B+W+A+UV
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 18
15 Hex Bar IP System Menu
SYSTEM MENU
The xture includes an easy to navigate system menu control panel display where all necessary
settings and adjustments are made. (See image below) During normal operation, pressing the MENU
button once will access the xture’s main menu. Once in the main menu, you can navigate through
the dierent functions and access the sub-menus with the UP and DOWN buttons. When you reach
a eld that requires adjusting, press the ENTER button to access that eld and use the UP and
DOWN buttons to adjust the eld. Pressing the ENTER button once more will conrm your setting.
You may exit the main menu at any time without making any adjustments by pressing the MENU
button.
ADJ Products, LLC - www.adj.com - 15 Hex Bar IP User Manual Page 19
15 Hex Bar IP System Menu
DMX SET
001-512
DMX Lost Status
DMX Channel Mode
Selection
DMX Addressing
6CH / 9CH / 12CH / 14 CH / 17CH / 30CH /
33CH / 38CH / 41CH / 60CH
MENU OPTIONS DESCRIPTIONSUBMENU
Slave Setting
Address
Ch. Mode
No DMX Hold / Blackout / Int. Prog
Persnlty
(Personality)
Manual
On / Off
On / Off
Manual Control Settings
Master Setting
Dim Mode
Dimming Curve Modes
Dimming Speed
Standard / Stage / TV / Archi (Architectural) /
Theatre / Stage 2
DimSpeed: 0.1-0.9s ~ 1-10s
LEDRfrsh
(LED Refresh Rate)
900 / 1000 / 1100 / 1200 / 1300 / 1400 / 1500 /
2500 / 4000 / 5000 / 10000 / 15000 / 20000 /
25000 (Hz)
LED Refresh Setting
Gamma
2.0 / 2.2 / 2.4 / 2.6 / 2.8 Gamma Brightness
Display
SaveDlay: 1~10M Display Shutoff Time
Service
Restore: YES / NO
(Pass Code = 011)
Calibration Adjustment
Restore Factory Settings
Red
Green
Blue
White
Amber
UV
Strobe
MastrDim
ClrMacro
ClrTemp
Lock: OFF / 1M~10M Display Control Lock
Pass Code = 50
Calibrat (Calibration)
(Pass Code = 050)
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-063
000-255
Master
Slave
IntProgs
(Internal Programs)
Prog 1
Prog 2
Prog 3
Prog 4
Prog 5
Program 6
Program 7
Program 8
Program 9
Program 10
Program 11
Program 12
Program 13
Program 1 with Adjustments
Program 2 with Adjustments
Program 3 with Adjustments
Program 4 with Adjustments
Program 5 with Adjustments
Program 6 with Adjustments
Program 7 with Adjustments
Program 8 with Adjustments
Program 9 with Adjustments
Program 10 with Adjustments
Program 11 with Adjustments
Program 12 with Adjustments
Program 13 with Adjustments
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
Speed: 000-255 Fade: 000-255
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

ADJ 15 HEX BAR IP User manual

Category
Floodlights
Type
User manual

ADJ 15 HEX BAR IP is a multi-colored, IP65-rated LED wash fixture with electronic dimming, DMX-512 protocol, and locking 5-pin XLR connections. It offers 10 DMX channel modes, allowing for various lighting effects and programming options. The unit can operate in standalone mode or be set up in a master/slave configuration for synchronized shows. It features multiple unit power linking capabilities and includes a removable frost/diffuser filter and glare shield for customizing the light output.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI