ADJ Hydro Beam X2 User manual

Category
Floodlights
Type
User manual
User Instructions
HYDRO BEAM X2
Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when
they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power
when not in use. Thank you!
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document
may be available online.
Please check www.adj.com for the latest revision/update of this manual before beginning
installation and/or programming.
©2019 ADJ Products, LLC all rights reserved. Information, specications, diagrams, images, and
instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying
product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection
claimed includes all forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this document may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of
their respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic
loss associated with the use or reliance of any information contained within this document, and/or as
a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation
of this product.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installa
-
tion. This device uses and can radiate radio frequency energy and, if not installed and used in accordance
with the included instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by turning the device off and on, the
user is encouraged to try to correct the interference by one or more of the following methods:
· Reorient or relocate the device.
· Increase the separation between the device and the receiver.
· Connect the device to an electrical outlet on a circuit different from which the radio receiver is
connected.
· Consult the dealer or an experienced radio/TV technician for help.
10/30/19
1 1.5
15 / 17 Initial Version
Date
Document
Version
Software
Version >
DMX Channel
Mode
Notes
12/17/19
1.2
1.7
N/C Updated Display Lock/Unlock Feature
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 2
Hydro Beam X2 Table of Contents
Introduction
Features I Warranty Registration
IP65 Notice
Safety Guidelines
Overview
Discharge Lamp Warning
Lamp Installation
Gobo Specications I Gobos
Gobo Installation
Fixture Installation
Connections
DMX Set Up
DMX Addressing
DMX Channel Modes
System Menu
WiFly Control
Error Codes
Dimensional Drawings
Power Linking I Cleaning
Limited Warranty (USA Only)
Technical Specications
3
4
5
6
10
11
13
17
18
22
25
26
27
28
31
38
40
42
43
44
45
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 3
Hydro Beam X2 Introduction
Unpacking: Thank you for purchasing the Hydro Beam X2 by ADJ Products, LLC. Every Hydro Beam
X2 has been thoroughly tested and has been shipped in perfect operating condition. Carefully check
the shipping carton for damage that may have occurred during shipping. If the carton appears to be
damaged, carefully inspect your xture for any damage and be sure all accessories necessary to operate
the unit has arrived intact. In the case damage has been found or parts are missing, please contact our
toll free customer support number for further instructions. Do not return this unit to your dealer without
rst contacting customer support.
Introduction: The ADJ Hydro Beam X2 is a DMX intelligent, IP rated, high powered, moving head fixture.
To optimize the performance of this product, please read these operating instructions carefully to
familiarize yourself with the basic operations of this unit. This product is intended to be used by
professionally trained personnel only and is not suitable for private use.
These instructions contain important safety information regarding the use and maintenance of this
unit. Please keep this manual with the unit, for future reference.
Customer Support: Contact ADJ Service for any product related service and support needs. Also visit
forums.adj.com with questions, comments or suggestions.
Parts: To purchase parts online visit:
http://parts.adj.com (US)
http://www.adjparts.eu (EU)
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
Voice: 800-322-6337 | Fax: 323-582-2941 | [email protected]
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | [email protected]
ADJ PRODUCTS LLC USA
6122 S. Eastern Ave. Los Angeles, CA. 90040
323-582-2650 | Fax 323-532-2941 | www.adj.com | info@adj.com
ADJ SUPPLY Europe B.V
Junostraat 2 6468 EW Kerkrade, The Netherlands
+31 (0)45 546 85 00 | Fax +31 45 546 85 99
www.adj.eu | [email protected]
ADJ PRODUCTS GROUP Mexico
AV Santa Ana 30 Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself,
doing so will void your manufactures warranty. In the unlikely event your unit may require service
please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
Hydro Beam X2 Features
IP65 Outdoor Rated
Electronic Dimming 0-100%
DMX-512 protocol
IP65 Locking 5-Pin XLR Connectors In & Out
Multiple DMX Modes
IP65 Locking Power Connectors In & Out
Colors: 10 + Open (Including 3200K, 5600K, UV, and Quad Split Color)
Gobos: 11 Rotating/Replaceable Gobos + Open
Prism 1: Rotating 6-Facet Linear
Prism 2: Rotating 8-Facet Circular
Frost Effect
Motorized Focus
Multiple Unit Power Linking (See page 43)
Included:
1 x IP65 Locking Power Cable
2 x Omega Brackets
Hydro Beam X2 Warranty Registration
The Hydro Beam X2 carries a 2 year limited warranty. Please fill out the enclosed warranty card to
validate your purchase. All returned service items whether under warranty or not, must be freight pre-
paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on
the outside of the return package. A brief description of the problem as well as the R.A. number must
also be written down on a piece of paper included in the shipping carton. If the unit is under war-
ranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by
contacting our customer support team on our customer support number. All packages returned to the
service department not displaying a R.A. number on the outside of the package will be returned to the
shipper.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 4
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 5
Hydro Beam X2 IP Notice
IP65 RATED
An IP rated lighting xture is one, which is commonly installed in outdoor environments
and has been designed with an enclosure that eectively protects the ingress (entry)
of external foreign objects such as dust and water. The International Protection (IP)
rating system is commonly expressed as "IP" (Ingress Protection) followed by two
numbers (i.e. IP65) where the numbers dene the degree of protection. The rst digit
(Foreign Bodies Protection) indicates the extent of protection against particles entering
the xture and the second digit (Water Protection) indicates the extent of protection
against water entering the xture. An IP65 rated lighting xture is one, which has been
designed and tested to protect against the ingress of dust (6) and low-pressure water
jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS
NOT suitable for marine and/or coastal environment installations. Installing
this xture in a marine and/or coastal environment may cause corrosion and/
or excessive wear to the interior and/or exterior components of the xture.
Damages and/or performance issues resulting from installation in a marine
and/or coastal environment will void the manufactures warranty and will NOT be subject
to any warranty claims and/or repairs.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 6
Hydro Beam X2 Safety Guidelines
FOR YOUR OWN PERSONAL SAFETY, PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY
BEFORE YOU ATTEMPT TO INSTALL OR OPERATE THIS UNIT!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS
YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM
MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND
GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO
ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG THE FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH THE FIXTURE DURING OPERATION AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE
(AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR
ELECTRICAL SHORT CIRCUIT.
IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH AS RELOCATION
FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, DO NOT POWER THE FIXTURE
ON IMMEDIATELY. INTERNAL CONDENSATION AS A RESULT OF ENVIROMENTAL TEMPERATURE
CHANGE CAN CAUSE INTERNAL FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS
REACHED ROOM TEMPERATURE BEFORE POWERING ON.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
Be sure that the local power outlet is compatible with the required voltage for your unit.
Do not attempt to operate this unit if the power cord has been frayed or broken.
Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to
reduce the risk of electrical shock and re in case of an internal short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user serviceable parts inside.
Never operate this unit when it’s cover is removed.
Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this
device and a wall.
Do not attempt to operate this unit, if it becomes damaged.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed
upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point
where they exit from the appliance.
Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 43 for cleaning
details.
Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other
appliances (including amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when the appliance does not appear to operate
normally or exhibits a marked change in performance.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 7
Hydro Beam X2 Safety Guidelines
SAFETY G U I DELI NES
To guarantee a smooth operation, it is important to follow all instructions and guidelines in
this manual. ADJ Products, LLC is not responsible for injury and/or damages resulting
from the misuse of this fixture due to the disregard of the information printed in this
manual. Only qualified and/or certified personnel should perform installation of this fixture
and only the original rigging parts included with this fixture should be used for installation.
Any modifications to the fixture and/or the included mounting hardware will void the
original manufactures warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID
YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM
MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF
SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID
THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY
WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY
SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST
ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR
ELECTRICAL SHORT CIRCUIT.
IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE
CHANGES SUCH AS RELOCATION FROM AN OUTDOOR COLD TO AN
INDOOR WARM ENVIRONMENT, DO NOT POWER THE FIXTURE ON
IMMEDIATELY. INTERNAL CONDENSATION AS A RESULT OF
ENVIRONMENTAL TEMPERATURE CHANGE CAN CAUSE INTERNAL
FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT
HAS REACHED ROOM TEMPERATURE BEFORE POWERING ON.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 8
Hydro Beam X2 Safety Guidelines
S A FETY GUI D ELI N E S
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET UV
RADIATION! FIXTURE EMITS HIGH INTENSITY WAVELENGTH
OF ULTRAVIOLET UV LIGHT FROM THE UV COLOR FILTER.
WEAR PROPER EYE AND SKIN PROTECTION. AVOID
PROLONGED PERIODS OF EXPOSURE TO UV COLOR FILTER.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING
UV PAINTS ON SKIN. AVOID DIRECT EYE AND/OR SKIN
EXPOSURE AT DISTANCES LESS THAN 11 feet (3.3m). DO NOT OPERATE FIXTURE
WITH DAMAGED/MISSING EXTERNAL COVERS. DO NOT LOOK DIRECTLY INTO THE
UV LIGHT AND/OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT
MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT. INDIVIDUALS SUFFERING
FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DIS-ORDERS, OR
INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT
IF EXPOSED TO THE ULTRAVIOLET UV LIGHT EMITTED FROM THE UV LED.
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow
approximately 60 minutes for the fixture to cool down before servicing.
DO NOT shake fixture; avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped, damaged and/or if any
of the power cord connectors are damaged and do not insert into the fixture securely with
ease.
NEVER force a power cord connector into the fixture. If the power cord or any of its
connectors are damaged, replace it immediately with a new one of similar power rating.
DO NOT block any air ventilation slots; these must remain clean and never blocked.
Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
When installing fixture in a suspended environment, always use mounting hardware that is no
less than M10 x 25 mm, and always attach an appropriately rated safety cable.
ALWAYS disconnect fixture from main power source before performing any type of service
and/or cleaning procedure. Only handle the power cord by the plug end; never pull out the
plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the interior
of the fixture. This is a normal process and is caused by excess paint in the interior of the casing
burning off from the heat associated with the lamp and will decrease gradually over time.
Consistent operational breaks will ensure fixture will function properly for many years.
ONLY use the original packaging and materials to transport the fixture in for service.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 9
POTENTIAL INTERNAL FIXTURE DAMAGE FROM EXTERNAL SOURCES OF LIGHT BEAMS
External sources of light beams from direct sunlight, lighting moving head xtures, and lasers, which
are focused directly towards the exterior housing and/or penetrate the front lens opening of ADJ
lighting xtures, can cause severe internal damage including burning to optics, dichroic color lters,
glass and metal gobos, prisms, animation wheels, frost lters, iris, shutters, motors, belts, wiring,
discharge lamps, and LEDs.
This issue is not specic only to ADJ lighting xtures, it is a common issue with lighting xtures
from all manufacturers. Although there is no true way to fully prevent this issue from happening, the
guidelines below can prevent any potential damage from occurring if followed. Contact ADJ Service
for more details.
DO NOT EXPOSE THE FIXTURE AND/OR FRONT LENS OPENING TO LIGHT BEAMS FROM DIRECT
SUNLIGHT, OTHER LIGHTING MOVING HEAD FIXTURES, AND LASERS WHILE UNPACKING,
INSTALLATION, USE, AND EXTENDED IDLE TIMES OUTDOORS.
DO NOT FOCUS A LIGHT BEAM FROM ONE LIGHTING FIXTURE DIRECTLY TOWARDS ANOTHER.
Hydro Beam X2 Safety Guidelines
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 10
Hydro Beam X2 Overview
3 4 5 96 87 10
1
11
MENU
ENTER
2
1. Lens
2. MENU Button
3. ENTER Button
4. LCD Menu Control Display
5. DOWN Button
6. UP Button
7. IP65 Locking 5-Pin XLR Connector OUT
8. IP65 Locking 5-Pin XLR Connector IN
9. Gore Valve
10. IP65 Locking Power Connector IN
11. IP65 Locking Power Connector OUT
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 11
Hydro Beam X2 Discharge Lamp Warning
D I SCHARGE L A M P W ARNI N G
This fixture is fitted with a DISCHARGE LAMP, which is highly
susceptible to damage if improperly handled. NEVER touch the
lamp with your bare hands as the oil from your hands will shorten
the life of the lamp. Also, NEVER move the fixture until the lamp
has had ample time to cool. Lamps are NOT covered under
warranty conditions. Avoid switching the fixture ON and OFF
repeatedly in short intervals as this will reduce lamp life and
intensity. To achieve the intensity associated with discharge
lamps, these lamps use gas sealed in a high-pressure
environment to emit a brilliant output.
Due to the high pressure involved with the construction of the lamp, the lamp MAY
EXPLODE DURING PROLONGED EXTENSIVE USE. This risk is increased with age;
added care is encouraged when dealing with older lamps. Thus, the lamp must always
be replaced at the end of their recommended duty cycle. Extreme caution should be
used when operating this or any fixture fitted with a gas discharge lamp.
U V RADI ATI ON NOT I C E
This fixture emits intense UV radiation, which is harmful to the
eyes and skin.
The intense luminance of the lamp can cause
severe damage to the retina. NEVER operate this fixture with
ANY of the protective covers removed. These covers have been
specially designed to shield against UV radiation.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 12
Hydro Beam X2 Discharge Lamp Warning
LAMP REPLACEMENT WARNING
NOTE: The lamp life is represented in “Percentages”.
When the unit reaches 15% of lamp life left, the display will ash the message “Replace The Lamp Soon.
This message will ash for up to 10 minutes. To conrm this warning and return to normal operation,
press the ENTER button.
When the unit reaches 10% of lamp life left, the display will again ash the message “Replace The Lamp
Soon”. This message will ash for up to 10 minutes. To conrm this warning and return to normal
operation, press the ENTER button. NOTE: When the xture is powered OFF and then back ON
again, the xture display will ash the following message: “Replace The Lamp Soon”.
When the unit reaches between 5%-0%% of lamp life left, the display will ash the message
“Replace The Lamp Immediately”. The unit will now NO longer respond to DMX commands and
enter hibernation mode which will discontinue all xture functionality with the exception of a few
menu commands.The xture will continue to enter into hibernation mode until the lamp is replaced
and the lamp time (LAMP ON TIME-R) has been reset. See page 36 “LAMP ON TIME-R” under the
“TOTAL LAMP TIME” submenu.
NOTE: After replacing the lamp, the lamp time MUST be reset. The lamp time must be reset to
gain access to the full system menu.
Lamp Life may vary depending on several factors including but not limited to:
Enviromental Conditions, Power/Voltage, Usage Patterns (On-O Cycling), Control,
and Dimming.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 13
2. Unscrew the (4x) allen head screws to remove the rear cover. When removing the rear cover,
please be advised that the cover is connected to the unit via a safety cable and connected wire
cable.
Hydro Beam X2 Lamp Installation
LAMP INSTALLATION
WARNING! LAMP REPLACEMENT SHOULD ONLY BE DONE BY A TRAINED TECHNICIAN.
1. Turn OFF power and allow approximately 60 minutes for the xture to cool down.
4. Loosen the Phillips head screw to unlock
the lamp holding slider.
3. Gently remove the (2x) spade terminals
connected to the lamp.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 14
Hydro Beam X2 Lamp Installation
5. Carefully slide the lamp to the right and tighten the Phillips head screw. Carefully remove the lamp
from its holder and replace with the same type lamp.
6. Once the new lamp has been inserted, loosen the Phillips head screw again to allow the lamp
holding mechanism to slide back to its closed position. Tighten the Phillips head screw.
Reconnect the (2x) spade terminal and replace the cover and tighten the (4x) Allen screws.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 15
Hydro Beam X2 Torque Settings & IP Tester
TORQUE SETTINGS FOR SCREWS
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are Allen Head
screws. Please see below for screw locations, screw quantity and torque settings. The number listed
in the “#” column corresponds to the location on the xture. See the xture diagram and number on
the next page for SCREW LOCATION depictions.
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES!
TO CONFIRM THE IP65 INTENGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTURE
USING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE DETAILS.
1 Lens Assembly to Head Casting (x14) 6.5-8.7 In-Lb / 3mm Hex
2 Lamp Cover to Head Casting (x4) 6.7-9.6 In-Lb / 4mm Hex
3 Plastic Head Cover to Head Casting (4 x Each Side = 8 Total) 6.5-8.7 In-Lb / 3mm Hex
4 Yoke Arm Cover to Yoke Frame (11 x Each Side = 22 Total) 6.5-8.7 In-Lb / 3mm Hex
5 Access Cover to Yoke Frame (x4) Manual Screwdriver / 3mm Hex
6 Bottom Cover to Base Casting (x16) 6.7-9.6 In-Lb / 3mm Hex
7 Power & Data Connector to Base Casting (x8) 6.5-8.7 In-Lb / Torx T8
8 1/4 Turn Adaptor Plate to Bottom Cover (x16) 6.5-8.7 In-Lb / 3mm Hex
SCREW LOCATIONS TORQUE SETTING & TOOL SIZE#
TORQUE DRIVERS (Recommended):
UTICA TS-30 (Shown)
ALTERNATIVE DRIVERS:
Proto J6107A
Wiha 28887
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 16
Hydro Beam X2 Screw Locations
4 4
3
3
5
5
1
2
8
8
6
6
6
6
7
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 17
Hydro Beam X2 Gobos
GOBO 1 GOBO 2 GOBO 3 GOBO 4 GOBO 5 GOBO 6
GOBO 7 GOBO 8 GOBO 9 GOBO 10 GOBO 11
Hydro Beam X2 Gobo Specifications
* * * IMPORTANT NOTICE REGARDING CUSTOM GOBOS * * *
Due to the extreme high temperature optical system, special BOROFLOAT glass material and design criteria
are required.
Due to varying gobo manufacturing processes and tolerances, it is highly recommended to provide a gobo
sample and gobo holder/wheel sample from the xture to the custom gobo vendor for accurate sizing. Gobo
specications below including diameter, thickness, and materials have been tested and are compatible in
this xture.
Using custom gobos that do not match the gobo specications below, is not recommended and any damage
to the xture as a result of using a custom gobo is NOT covered under warranty. Extended testing of custom
gobo designs is highly recommended prior to using.
PLEASE CONTACT ADJ CUSTOMER SUPPORT FOR FURTHER INFORMATION.
ROTATING GLASS GOBOS
Gobo O.D. (Max. Outer Diameter) ø9.7mm
Gobo I.D. (Max. Image Diameter) ø6.5mm
Gobo Holder Diameter ø10mm
Gobo Thickness ø0.5mm
Gobo Material BOROFLOAT
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 18
Hydro Beam X2 Gobo Installation
GOBO INSTALLATION
WARNING! GOBO REPLACEMENT SHOULD ONLY BE DONE BY A TRAINED TECHNICAN.
TURN OFF POWER AND ALLOW APPROXIMATELY 60 MINUTES FOR THE FIXTURE
TO COOL DOWN.
4 x Screws Total
2 x Screws on each side
4 x Screws Total
2 x Screws on
each side
Remove both moving head shells
Unscrew and remove the 8 screws
that secure the moving head shells.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 19
Hydro Beam X2 Gobo Installation
4 x Screws Total
2 x Screws on each side
4 x Screws Total
2 x Screws on
each side
Remove both moving head shells
Unscrew and remove the 8 screws
that secure the moving head shells.
After the moving head shells have been removed unscrew and remove the 10 screws
that secure the head in place. Carefully remove the head to access the inside module.
10 x Screws Total
5 x Screws on each side
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

ADJ Hydro Beam X2 User manual

Category
Floodlights
Type
User manual