Topcon DL-502 User manual

Type
User manual

This manual is also suitable for

DL-502
DL-503
INSTRUCTION MANUAL
DIGITAL LEVEL
FC11808-A022-02
DL-500 SERIES
http://www.topcon.co.jp
GLOBAL GATEWAY http://global.topcon.com/
Please see the attached address list or the following website for contact addresses.
Cover1-4.fm 1 ページ 2010年4月5日 月曜日 午後12時0分
1
SURVEYING INSTRUMENTS
Thank you for selecting the Digital Level DL-502/503.
Please read this operator's manual carefully before using this
product.
Verify that all equipment is included. See "20.1 Standard Equip-
ment".
DL-502/503 has a function to output data saved in DL-502/503 to
a connected computer. Commands operations from a computer
can also be performed. For details, refer to the “Output Formats
and Command Explanations (DL Edition)” manual and ask your
local dealer.
The specifications and general appearance of the instrument are
subject to change without prior notice and without obligation by
TOPCON Corporation and may differ from those appearing in this
manual.
The content of this manual is subject to change without notice.
Some of the diagrams in this manual may be simplified for easier
understanding.
DIGITAL LEVEL
DL-502
DL-503
DL-500 SERIES
INSTRUCTION MANUAL
DL502-503.book 1 ページ 2010年4月5日 月曜日 午前9時47
2
CONTENTS
Read This First
Introduction
Preliminaries
Surveying
Managing
Recorded Data
1. Precautions for Safe Operation ..........................4
2. Precautions.........................................................7
3. DL Functions ......................................................9
3.1 Parts of the Instrument and Operation .......9
3.2 Display......................................................11
3.3 Operating Keys.........................................15
3.4 Operating Modes ......................................16
4. Installing and Removing the Battery.................18
5. Setting Up the Instrument.................................19
6. Focusing and Sighting ......................................20
7. Basic Operation ................................................22
7.1 Reading the Staff......................................22
7.2 Measuring in Status Mode........................25
7.3 Measuring using Wave-and-Read ............26
8. Setting Up Data Storage...................................29
8.1 JOB Setting ..............................................29
8.2 Record Conditions ....................................31
8.3 Double-run Measurement.........................32
8.4 Flow of Recording Data ............................32
9. Measuring Height Difference ............................36
10. Measuring Elevation .........................................39
11. Setting Out Height Difference, Distance, and
Elevation...........................................................42
11.1 Setting Out Height Difference...................42
11.2 Setting Out Distance.................................44
11.3 Setting Out Elevation................................45
12. Other Measurement Functions .........................48
12.1 Measuring Horizontal Angle .....................48
12.2 Using the Instrument as a Standard
Level .........................................................48
13. Displaying Recorded Data................................49
13.1 Data Check and Edit.................................49
DL502-503.book 2 ページ 2010年4月5日 月曜日 午前9時47
3
Managing
Recorded Data
Other
Procedures
Specifications
Regulations
13.2Number of Recorded Points............................50
14. JOB Delete .......................................................51
15. Sending Recorded Data ...................................53
15.1 Connecting to a Computer or Data
Collector ...................................................53
15.2 Data Output ..............................................54
16. Changing the Settings ......................................56
16.1 Measuring Mode.......................................56
16.2 Fractional / Decimal representation of
Height Unit................................................57
16.3 Communication Parameters .....................58
16.4 Auto Power-Off .........................................58
16.5 Unit of Measurement ................................59
17. Warnings and Error Messages .........................60
18. Charging the Battery.........................................63
19. Checks and Adjustments..................................65
19.1 Adjusting the Circular Level......................65
19.2 Adjusting the Reticle.................................66
20. Equipment and Accessories .............................72
20.1 Standard Equipment.................................72
20.2 Optional Accessory...................................73
20.3 Staffs ........................................................74
21. Specifications ...................................................76
22. Regulations.......................................................80
DL502-503.book 3 ページ 2010年4月5日 月曜日 午前9時47
4
Read This First
1. Precautions for Safe Operation
For the safe use of the product and prevention of injury to operators
and other persons as well as prevention of property damage, items
which should be observed are indicated in this operator's manual by
WARNING and CAUTION indications.
The definitions of the indications are listed below. Be sure you
understand them before reading the manual's main text.
Definitions of Indications
Do not use voltage other than the specified power supply voltage.
Fire or electrical shock could result.
Do not use the unit in areas exposed to high amounts of dust or
ash, in areas where there is inadequate ventilation, or near
combustible materials. An explosion could occur.
Do not perform disassembly or rebuilding. Fire, electric shock or
burns could result.
Never look at the sun through the telescope. Loss of eyesight could
result.
Do not look at reflected sunlight from a prism or other reflecting
object through the telescope. Loss of eyesight could result.
Do not use the carrying case as a footstool. The case is slippery
and unstable so a person could slip and fall off it.
Do not place the instrument in a case with a damaged catch, belt or
handle. The case or instrument could be dropped and cause injury.
WARNING
Ignoring this indication and making an operation
error could possibly result in death or serious
injury to the operator.
CAUTION
Ignoring this indication and making an operation
error could possibly result in minor injury or
property damage.
General
Warning
Caution
DL502-503.book 4 ページ 2010年4月5日 月曜日 午前9時47
Read This First
5
Do not use under thunderous weather conditions. This unit is
conductive and if struck by lightning, death or injury could result.
Handle with care when using near high voltage cables or
transformers. This unit is conductive and contact could result in
electric shock.
When mounting the instrument to the tripod, tighten the centering
screw securely. Failure to tighten the screw properly could result in
the instrument falling off the tripod, causing injury.
Tighten securely the leg fixing screws of the tripod on which the
instrument is mounted. Failure to tighten the screws could result in
the tripod collapsing, causing injury.
Do not carry the tripod with the tripod shoes pointed at other
persons. A person could be injured if struck by the tripod shoes.
Keep hands and feet away from the tripod shoes when fixing the
tripod in the ground. A hand or foot stab wound could result.
Tighten the leg fixing screws securely before carrying the tripod.
Failure to tighten the screws could lead to the tripod legs extending,
causing injury.
Use only the specified battery charger to recharge batteries. Other
chargers may be of different voltage rating or polarity, causing
sparking which could lead to fire or burns.
Do not place articles such as clothing on the battery charger while
charging batteries. Sparks could be induced, leading to fire.
Do not use damaged power cords, plugs or loose outlets. Fire or
electric shock could result.
Do not use batteries or the battery charger if wet. Resultant
shorting could lead to fire or burns.
Staff
Warning
Tripod
Caution
Power Supply
Warning
DL502-503.book 5 ページ 2010年4月5日 月曜日 午前9時47
6
Read This First
To prevent shorting of the battery in storage, apply insulating tape
or equivalent to the terminals. Otherwise shorting could occur
resulting in fire or burns.
Do not heat or throw batteries into fire. An explosion could occur,
resulting in injury.
Do not connect or disconnect power supply plugs with wet hands.
Electric shock could result.
Do not touch liquid leaking from batteries. Harmful chemicals could
cause burns or blisters
Caution
DL502-503.book 6 ページ 2010年4月5日 月曜日 午前9時47
7
Read This First
2. Precautions
Using the Instrument
The DL-502/503 is a precision instrument. Avoid severe shocks or
vibration.
Be careful when removing the instrument from its case.
Do not place the DL-502/503 directly on the ground.
When the operator leaves the DL-502/503, the vinyl cover should
be placed on the instrument.
Never carry the DL-502/503 on the tripod to another site.
Always turn the instrument off and remove the battery before
storing the instrument in its case.
When the instrument is placed in the carrying case, see "20.1
Standard Equipment".
Always wipe off moisture and dirt adhering to the instrument during
survey work. Moisture or dirt on the lens may result in incorrect
readings.
Consult your local dealer before using the instrument under special
conditions such as long periods of continuous use or high levels of
humidity. In general, special conditions are treated as being outside
the scope of the product warranty.
Maintenance
Always clean the instrument before returning it to the case. The
lens requires special care. Dust it off with the lens brush first, to
remove tiny particles. Then, after providing a little condensation by
breathing on the lens, wipe it with the supplied cleaning cloth or
lens tissue.
If the display is dirty, carefully wipe it with a soft, dry cloth. To clean
other parts of the instrument or the carrying case, lightly moisten a
a soft cloth in a mild detergent solution. Wring out excess water
until the cloth is slightly damp, then carefully wipe the surface of the
unit. Do not use any organic solvents or alkaline cleaning solutions.
Store the instrument and accessories in a dry room where the
temperature remains fairly constant.
If any trouble is found with the screws or optical parts (e.g. lens),
contact your local dealer.
DL502-503.book 7 ページ 2010年4月5日 月曜日 午前9時47
8
Read This First
Always close the case when empty to protect the interior from
humidity and dust.
Regular checking and adjustment is recommended to maintain
instrument precision.
Exceptions from responsibility
The user of this product is expected to follow all operating
instructions and make periodic checks (hardware only) of the
product’s performance.
The manufacturer, or its representatives, assumes no responsibility
for results of faulty or intentional usage or misuse including any
direct, indirect, consequential damage, or loss of profits.
The manufacturer, or its representatives, assumes no responsibility
for consequential damage, or loss of profits due to any natural
disaster, (earthquake, storms, floods etc.), fire, accident, or an act
of a third party and/or usage under unusual conditions.
The manufacturer, or its representatives, assumes no responsibility
for any damage (change of data, loss of data, loss of profits, an
interruption of business etc.) caused by use of the product or an
unusable product.
The manufacturer, or its representatives, assumes no responsibility
for any damage, and loss of profits caused by usage different to
that explained in the operator’s manual.
The manufacturer, or its representatives, assumes no responsibility
for damage caused by incorrect operation, or action resulting from
connecting to other products.
DL502-503.book 8 ページ 2010年4月5日 月曜日 午前9時47
9
Introduction
3. DL Functions
3.1 Parts of the Instrument and Operation
Handle
Bubble mirror
When the instrument is placed high up and cannot be viewed
from above, you can use the mirror to check the position of the
bubble in the tube.
Circular level
Objective lens
Focusing knob
Use this knob to focus on the staff.
Except where stated, screens and illustrations appearing in this
manual are of DL-502/503.
In principle, screens used in procedures are based on the factory
setting.
Important:
1
2
3
4
5
DL502-503.book 9 ページ 2010年4月5日 月曜日 午前9時47
10
Introduction
Measure key (appears as in this manual)
Starts measurement.
(See "3.3 Operating Keys".)
Horizontal fine motion knobs (both sides)
Use these knobs to finely adjust the instrument's horizontal
position.
Data output connector
You can connect a data collector or computer to this connector.
Leveling foot screw
Base plate
Horizontal circle positioning ring
You can rotate the horizontal scale while the instrument is fixed
in position. Use to align benchmarks with '0', etc.
Horizontal circle
Reticle adjusting screw and screw cover
Use this screw to mechanically adjust the reticle.
Battery cover
Eyepiece
Adjust the reticle focus to suit your eyesight.
Keyboard (See "3.3 Operating Keys".)
Display (See "3.2 Display".)
Gunsight
Use for coarse adjustment of the orientation of the instrument.
6
Measure
7
8
9
10
11
12
13
14
15
16
17
18
DL502-503.book 10 ページ 2010年4月5日 月曜日 午前9時47分
11
Introduction
3.2 Display
The display includes the following marks which indicate the
operating status and current mode, and help the operator to
keep track of the measurement procedure.
Point number display
The next point number to be recorded is displayed.
Mode display
The displayed mark shows the current mode.
: Status mode or Measurement mode
: Menu mode
: JOB setting mode
: Record setting mode
: Height difference measurement mode
: Elevation measurement mode
: Setting out mode
: Configuration mode
: Data review menu
Version number
Currently selected
JOB
Measurement
Battery level
conditions
indicator
Mode indicator
Attribute•Measure-
Point number
ment step
Measurement values and other data
DL502-503.book 11 ページ 2010年4月5日 月曜日 午前9時47分
12
Introduction
Attribute•Measurement step display
Displays the backsight and foresight (in Height difference, Setting
out, or Measuring elevation modes).
: Backsight
: Foresight
Displays the attribute of the recorded measurement value (Height
difference measurement mode, Elevation measurement mode).
: Backsight point
: Foresight point
: Intermediate sight
: Fixed point
:Off
Displays the measurement step (when Adjustment is selected in
the Configuration mode).
At position A
: Take a reading on staff a.
: Take a reading on staff b.
: Take a reading on staff a with the tripod turned 180°.
: Take a reading on staff b with the tripod turned 180°.
At position B
: Take a reading on staff a.
: Take a reading on staff b.
: Take a reading on staff a with the tripod turned 180°.
: Take a reading on staff b with the tripod turned 180°.
Displays the page number of the active menu (when the Menu
mode or Configuration mode is selected).
:First page
: Second page
Measuring mode (not displayed on menu screens)
Displays the currently selected measuring mode.
: Single measurement
: Average measurement
: Wave-and-Read measurement
: Repeat measurement
: Tracking measurement
DL502-503.book 12 ページ 2010年4月5日 月曜日 午前9時47分
13
Introduction
Battery level (not displayed on menu screens)
Displays the current power level of the battery.
: Level 3: Full power.
: Level 2: Plenty of power remains.
: Level 1: Half or less power remains.
: Level 0: Little power remains. Charge the battery.
: Low: No power remains (A beep tone sounds and the
battery symbol blinks.) Charge the battery. Operation
cannot be performed. After a short time the instrument
automatically powers off.
Measurements
The following symbols are displayed.
: Staff reading (height)
: Horizontal distance to staff
: Height difference
:Elevation
The fractional/decimal display format for measurement value,
calculation value and input value depends on the settings in
measuring mode and fractional/decimal representation of height
units. (See "16. Changing the Settings".)
When the fractional/decimal display format is set to "0.0001m" and
the unit of measurement is "m", the display is as follows:
When measuring mode is "Single",
"Average" or "Repeat"
Height: Up to 4 decimals
Distance: Up to 2 decimals
When measuring mode is "Tracking"
Height: Up to 3 decimals
Distance: Up to 1 decimal
DL502-503.book 13 ページ 2010年4月5日 月曜日 午前9時47分
14
Introduction
When the fractional/decimal display format is set to "0.001m" and
the unit of measurement is "m", the display is as follows:
When the fractional/decimal display format is set to "0.001ft" and
the unit of measurement is "ft", data is displayed as follows:
When measuring mode is "Single", "Average" or "Repeat"
Height: Up to 3 decimals
Distance: Up to 1 decimal
When measuring mode is "Tracking"
Height: Up to 2 decimals
Distance: 0 decimal
When the fractional/decimal display format is set to "0.01ft" and the
unit of measurement is "ft", data is displayed as follows:
When measuring mode is "Single", "Average" or "Repeat"
Height: Up to 2 decimals
Distance: Up to 1 decimal
When measuring mode is "Tracking"
Height: Up to 1 decimal
Distance: 0 decimal
When the fractional/decimal display format is set to "1/8" and the
unit of measurement is "inch", the display is as follows:
When measuring mode is "Single",
"Average" or "Repeat"
Height: Up to 3 decimals
Distance: Up to 2 decimals
When measuring mode is "Tracking"
Height: Up to 2 decimals
Distance: Up to 1 decimal
When measuring mode is "Single",
"Average" or "Repeat"
Height: **-**-*/
*
Distance: **-**
When measuring mode is "Tracking"
Height: **-**-*/
*
Distance: **
DL502-503.book 14 ページ 2010年4月5日 月曜日 午前9時47分
15
Introduction
3.3 Operating Keys
Learn main key operations here.
Power ON/OFF
: Power the instrument ON
(hold) + : Power the instrument OFF
Light up the display
: Switch the display backlight ON / OFF
Measurement start / stop
: Start measurement
/ : Stop measurement (in repeat, average or tracking
mode)
: Cancel measurement
Select / cancel (return to former procedure) menus and options
/ : Scroll to next position (JOB selection, item selection,
etc.)
: Accept the option
: Enter Menu mode
: Return to former procedure or to Status mode
Value input / cancel
: Advance the numeral
Toggle the +/- sign
: Change the position of the inverted cursor
: Accept the input value
• The fractional/decimal display format for distance measurements
depends on the setting in measuring mode only.
Note:
Measure
Measure
DL502-503.book 15 ページ 2010年4月5日 月曜日 午前9時47分
16
Introduction
3.4 Operating Modes
The DL has a number of functional modes. This section
shows the screens that can be displayed in each mode.
: Key operation for selecting each menu
: Key operation for returning to previous screen
[Instrument information mode]
[Measurement mode]
[Job setting mode]
[Record setting mode]
[Status mode]
ESC
ESC
ESC
Select
Measure
[At completion of a
measurement]
[Menu of selected
function is displayed]
ESC
Select
[Menu of selected
function is displayed]
[Menu mode]
(Page 1)
(Page 2)
MENU
[Screen showing the number
of points that can be
recorded is displayed]
Select
A B
DL502-503.book 16 ページ 2010年4月5日 月曜日 午前9時47分
17
Introduction
[Height difference measurement mode]
ESC
Select
[Menu of selected
function is displayed]
Select
[Menu of selected
function is displayed]
[Elevation measurement mode]
[Setting out .....]
[Config. mode]
(Page 1)
(Page 2)
MENU
A B
DL502-503.book 17 ページ 2010年4月5日 月曜日 午前9時47分
18
Preliminaries
4. Installing and Removing the Battery
Install a fully-charged battery (see "18. Charging the Battery").
1
2
3
Procedure
Always turn off the power before removing the battery from the
instrument. If the battery is removed when the power is still on,
stored data may be lost.
Important:
DL502-503.book 18 ページ 2010年4月5日 月曜日 午前9時47分
19
Preliminaries
5. Setting Up the Instrument
1 Set up the tripod.
Spread the tripod legs about the same distance apart so that the
tripod head is approximately level. Tread the tripod shoes firmly into
the ground.
2 Mount the instrument on the tripod.
Hold the instrument on the tripod head and tighten the centering
screw.
3 Level the instrument.
Spherical head tripod: Loosen the centering screw and slide the
instrument across the tripod head until the
bubble is centered in the circular level.
Tighten the centering screw.
Flat head tripod: Extend or push in the tripod legs until the
bubble is centered in the circular level.
When the bubble is more or less centered,
turn the leveling foot screws until the
bubble is exactly centered in the circle.
When you turn a screw clockwise, raising
the instrument, the bubble will move toward
the position of that screw.
Procedure
DL502-503.book 19 ページ 2010年4月5日 月曜日 午前9時47分
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

Topcon DL-502 User manual