Using MODBUS with Series C Controllers
iv Ó Omega. 900M062U00
3.8.2.2 If Controller Is Configured to Support Decimal Places, Then the
Controller’s Storage Method for a Parameter Affects Values Read
and Written ........................................................................................ 4-11
3.8.2.3 Relative Addresses in 10X Region Are 1000 More Than the
Corresponding Address in the Base Region ...................................... 4-12
3.8.2.4 Because of Range Limits, the 10X Region Not Recommended
for FV
* Parameters When a Linear Input Is Used ............................. 4-12
3.8.3 Interpreting Fractional Controller Values Stored With Decimal Point
Transmitted in the 10X Region 1000 to 1999 ......................................... 4-12
3.8.3.1 Principles.............................................................................................. 4-12
3.8.3.2 Examples.............................................................................................. 4-13
3.8.3.2.1 Reading an FV* Parameter with Temperature Input....................... 4-13
3.8.3.2.2 Reading an FV Parameter ............................................................... 4-13
3.8.3.2.3 Writing to an FV Parameter ............................................................. 4-14
3.8.4 Interpreting Fractional Controller Values Stored Without Decimal
Point Transmitted in the 10X Region 1000 to 1999 ................................ 4-15
3.8.4.1 Principles.............................................................................................. 4-15
3.8.4.2 Examples.............................................................................................. 4-16
3.8.4.2.1 Reading an FV* Parameter from a Controller with a Linear Input –
Range Not Exceeded.................................................................... 4-16
3.8.4.2.2 Writing an FV* Parameter to a Controller with a Linear Input –
Range Not Exceeded.................................................................... 4-16
3.8.4.2.3 Reading an FV* Parameter from a Controller with a Linear Input –
Range Exceeded .......................................................................... 4-17
3.9 32-bit IEEE Mirror of Base Fractional Value Region: Register Addresses
8000 to 9999 ................................................................................................ 4-18
3.9.1 General Principles.................................................................................... 4-18
3.9.1.1 Introduction........................................................................................... 4-18
3.9.1.2 32-Bit IEEE Region Uses Two Registers Per Value Transmitted........ 4-18
3.9.1.3 Range of Values That Can Be Transmitted in the 32-Bit IEEE Region 4-18
3.9.1.4 If the Controller Is Configured to Use Decimal Places, Then the
Controller’s Storage Method for a Parameter Affects Values Read
and Written ........................................................................................ 4-18
3.9.1.5 32-Bit IEEE Region Allows You to Configure the Controller to Use
Values with More Than Four Digits ................................................... 4-19
3.9.1.6 Relative Addresses in 32-Bit IEEE Region Can Be Calculated from
the Relative Address of a Parameter in the Base Region................. 4-19
3.9.1.7 A MODBUS Command to Transmit a Value Using the 8000 to 9999
Region Always Addresses an Even-Numbered Relative Address .... 4-19
3.9.1.8 Sequence in Which the Two Registers for a 32-Bit IEEE Value
Will Be Transmitted ............................................................................ 4-20
3.9.2 Interpreting Fractional Controller Values Stored With Decimal Point
Transmitted in the 32-Bit IEEE Region 8000 to 9999 ............................ 4-20
3.9.2.1 Principles.............................................................................................. 4-20
3.9.2.2 Examples.............................................................................................. 4-20
3.9.2.2.1 Reading an FV* Parameter with Temperature Input...................... 4-20
3.9.2.2.2 Reading an FV Parameter .............................................................. 4-21