Morningstar ProStar User guide

Type
User guide

Morningstar ProStar is a versatile charge controller designed for off-grid solar applications. It efficiently manages power flow between solar panels, batteries, and loads, ensuring optimal battery charging and system performance. With advanced features like programmable battery charging parameters, equalization modes, and system voltage selection, it caters to a wide range of battery types and system configurations. The ProStar also offers comprehensive protection against overcharging, over-discharging, reverse current, and ground faults, ensuring the longevity of your system components.

Morningstar ProStar is a versatile charge controller designed for off-grid solar applications. It efficiently manages power flow between solar panels, batteries, and loads, ensuring optimal battery charging and system performance. With advanced features like programmable battery charging parameters, equalization modes, and system voltage selection, it caters to a wide range of battery types and system configurations. The ProStar also offers comprehensive protection against overcharging, over-discharging, reverse current, and ground faults, ensuring the longevity of your system components.

Optional Accessories
Quick Start Guide
14
Warning: Shock Hazard
Testbetweenallterminalsand
groundbeforetouching.
PoweroraccessoryterminalsareNOT
electricallyisolatedfromDCinputandmay
be energized with hazardous
solar voltage.
Switch 1: Load/Lighting Switches 2 & 3: System Voltage
Specifications:
Switches 4, 5, & 6: Battery Type Selection
Switch 7: Battery Equalization Switch 8: Current Switching
Operational Configuration:
Lighting
Normal
PS15/PS15M
NominalBatteryVoltage 12/24V
Max.PVOpenCircuitVoltage 30/60V
MaximumInputCurrent 15A
RatedLoadCurrent 15A
PS30/PS30M
12/24V
30/60V
30A
30A
©2022MorningstarCorporation.AllRightsReserved.
In the box:
Tools Required:
#2PhilipsScrewdriver
3/16(5mm)&3/32"(2.5mm)FlatheadScrewdriver
RemoteMeter(RM1)
EthernetMeterBus
Converter(EMC1)
Safety Information:
Warning: Shock Hazard
TheProStarGen3controllermustbeinstalledbya
qualifiedtechnicianinaccordancewiththeelectrical
regulationsofthecountryofinstallation.
Warning: Shock Hazard
ThisunitisnotprovidedwithaGFDIdevice.Thischarge
controllermustbeusedwithanexternalGFDIdeviceas
requiredbytheArticle690oftheNationalElectricalCode
fortheinstallationlocation.
IMPORTANT: READtheProStarGen3Installation
Manualforsafetyandregulatoryinformation,
instructionsonconfigurationandoperation,and
warrantyinformation.
PVGroundFaultProtection
(GFPD150V)
RemoteTemperature
Sensor(RTS)
Scan QR Code to go
directly to the
ProStar Gen3
Installation Manual
and warranty
information online.
Contact Information:
TechnicalSupport:Support.morningstarcorp.com
Phone:12153214457
AUTO 12V
24V
ManualEQ AutoEQ
ProStarChargeController
SlowSwitchingPWMSwitching
SystemVoltage Switch2
Auto OFF
12 OFF
Switch3
OFF
ON
24 ON OFF
Mode Switch1
Normal OFF
Lighting ON
Mode Switch8
PWMSwitching OFF
SlowSwitching ON
1Sealed*3Sealed*4AGM/
Flooded*
5Flooded 6Flooded 7L162Sealed*Custom**
Mode Switch7
ManualEqualization OFF
AutoEqualization ON
WarrantyRegistration:https://www.morningstarcorp.com/productregistration/
FloatCancelVoltage 12.10Volts
FloatExitTimeOut 30minutes
AbsorptionExtensionTime AbsorptionTime+30minutes
AbsorptionExtensionVoltage 12.50Volts
SharedSettings SetPoint SharedSettings SetPoint
TemperatureCompensationCoEfficient –30millivolts/°C/12Volts
EqualizeTimeOut EqualizeTime+60minutes
DIPSwitch
SettingBatteryType
Absorption
Stage
(Volts)
Float
Stage
(Volts)
Equalize
Stage
(Volts)
Absorption
Time
(Minutes)
Equalize
Time
(Minutes)
Equalize
Timeout
(Minutes)
Equalize
Interval
(days)
LVD
(Volts)
LVR
Volts)
456
OFFOFFOFF1Sealed*14.0013.50 ‐‐‐ 150 ‐‐‐ ‐‐‐ ‐‐‐ 11.512.6
OFFOFFON2Sealed*14.1513.5014.40150601202811.512.6
OFFONOFF3Sealed*14.3013.5014.60150601202811.512.6
OFFONON4AGM/Flooded*14.4013.5015.101801201802811.512.6
ONOFFOFF5Flooded14.6013.5015.301801201802811.512.6
ONOFFON6Flooded14.7013.5015.401801802402811.512.6
ONONOFF7L1615.4013.4016.001801802401411.512.6
ONONON8Custom**CustomCustomCustomCustomCustomCustomCustomCustomCustom
*“Sealed”batterytypesincludeGelandAGMBatteries
**Lithiumionandsomeotherbatterytypesrequirecustomprogramming.Morningstarprovidesdownloadablesettingsforselectedbattery
manufacturershere:https://www.morningstarcorp.com/energystoragepartnerprogram/
NOTE:TheProStarGen3canbeprogrammedtoaccommodateawiderangeofchargingparameters.
Consultthebatterymanufacturerforoptimalbatterychargingsettings.
ToChangeSettings:
Onmeteredmodels,usetheinterfaceonthemeterorusethesoftwareavailableathttps://www.morningstarcorp.com/msview/.
Onnonmeteredmodels,usethesoftwareavailableathttps://www.morningstarcorp.com/msview/.
SeetheProStarInstallation,Operations,andMaintenanceManualforadditionalinformation/guidance.
Meteredversionshown.
PCMeterBusAdapter
(MSC)
USBCommunications
Adapter(UMC1)
MenuMap(2pages)
SelfTapping
Mounting
Screws(x4)
MS001534rev. D
DIP
ON
1 2 34 5 6 7 8
SENSE
BATTERY
SOLAR
RTS
LOAD
Charging
Status/
Error LED
Battery Status/
Fault LEDs
32
ProStar Gen3 Charge Controller
Quick Start Guide
6"(15cm)MAXIMUMDistance
fromBattery(+)Terminal
(+)
(–)
(+) (–)
Solar Disconnect*
(PV GFP required per
NEC 690)
Photovoltaic (PV) Array
Battery / Battery Bank
Battery Disconnect*
*Fuseorbreakersizingbased
onrequiredwireampacity
Fuse
Primary Ground
Electrode Conductor
(System Ground)
12345678
DIP Switch Block
(enlarged)
(SeePage4forsettings)
DCtoGround
Bond
Power UP Sequence:
1. ConnectBattery/BatteryBank.
2. ConnectSolar.
Power DOWN Sequence:
1. DisconnectSolar.
2. DisconnectBattery/BatteryBank.
Mounting:
#2
Minimum
Clearance
Requirements
Caution: Equipment Damage
DonotexposetheProStarCCtoweather.Locate
inadry,protectedareatopreventequipment
damage.Ensuretheminimumclearance
requirementsarefollowedtoprovideadequate
ventilationandpreventtheunitfromoverheating.
6"
6"
2"
IMPORTANT: Exampleonly.Actualwiringmayvary.READ
theProStarGen3Installation,Operations,andMaintenance
Manualformandatorysafetyrequirements.Allconfiguration
mustcomplywithlocalandnationalelectriccodes.Consultyour
localelectricauthoritytoensurecompliance.
Thisillustrationrepresentsatypicaloffgridinstallation.Foruse
withaninverter,refertotheinverter’sinstallationmanualfor
additionalinformation.
SeetheMorningstarPVStringCalculatorat:
http://stringcalculator.morningstarcorp.com/
Component
PowerTerminals
WireSize
2.5‐16mm2/
#14‐6AWG
ToolRequired
3/16"(5mm)
FlatheadScrewdriver
BatteryVoltage
Sense
0.25‐1.0mm2/
#24‐16AWG
3/32"(2.5mm)
FlatheadScrewdriver
MountingScrews ‐‐‐ #2PhilipsScrewdriver
Wiring and Torque Requirements
Torque(Max)
35inlbs.(3.9Nm)
5inlbs.(0.56Nm)
5inlbs.(0.56Nm)
RemoteTemperature
Sensor (included) 3/32"(2.5mm)
FlatheadScrewdriver 5inlbs.(0.56Nm)
Securinghardware
notshown.
DC Load
Disconnect*
Pushtabsoutwardto
releasetheterminalcover.
Pulltheterminalcover
forwardtoremoveit.
2"
Tightenthe4selftapping
screwsjustenoughto
holdtheProStarinplace.
1
2
3
RJ11
Cable
Optional Accessories
RemoteMeter EthernetMeterBus
Converter
PCMeterBus
Adapter(MSC)
USBCommunications
Adapter(UMC1)
Battery(–)
(—)VoltageSense
Conductor
(+)VoltageSense
Conductor
RemoteTemperature
SensorConductor
Battery(+)
IMPORTANT:
Ensurethereisonly 1
DCNegativetoGround
Bondintheentiresystem.
IMPORTANT:
Mountintheorientationshown
herewiththeheatsinkfins
vertical.
Top
Bottom
IMPORTANT:
DoNOTovertighten.
ON
1 2 34 5 6 7 8
SENSE
BATTERYSOLAR
RTS
LOAD
ON
1 2 34 5 6 7 8
SENSE
BATTERYSOLAR
RTS
LOAD
DC Load(s)
Communications Lighting
Industrial
Security
Residential
LEDIndicators:
SeetheProStarGen3
InstallationManualfordetails.
Ground
LEGEND
Negative (–)
Positive (+)
  • Page 1 1
  • Page 2 2

Morningstar ProStar User guide

Type
User guide

Morningstar ProStar is a versatile charge controller designed for off-grid solar applications. It efficiently manages power flow between solar panels, batteries, and loads, ensuring optimal battery charging and system performance. With advanced features like programmable battery charging parameters, equalization modes, and system voltage selection, it caters to a wide range of battery types and system configurations. The ProStar also offers comprehensive protection against overcharging, over-discharging, reverse current, and ground faults, ensuring the longevity of your system components.