Paxton APN-1127-ZA User manual

Type
User manual

Paxton APN-1127-ZA is an Entry system designed for easy installation using a single network cable to link the Entry units. It allows you to have video intercom functionality with a simple setup of entry panels, control units, and internal video monitors. The system can operate with up to 100 panels and 1000 monitors, making it suitable for large buildings or campuses. You can integrate it with a Paxton10 or Net2 system for access control, allowing you to grant entry to authorized personnel remotely.

Paxton APN-1127-ZA is an Entry system designed for easy installation using a single network cable to link the Entry units. It allows you to have video intercom functionality with a simple setup of entry panels, control units, and internal video monitors. The system can operate with up to 100 panels and 1000 monitors, making it suitable for large buildings or campuses. You can integrate it with a Paxton10 or Net2 system for access control, allowing you to grant entry to authorized personnel remotely.

Entry - Planning and installation
Overview
The Entry system is designed to be as easy to install
as possible by using a single network cable to link the
Entry units.
The system consists of one or more entry panels, each
associated with a control unit and as many internal
video monitors as are required for the occupants.
A simple network can then be wired using Paxton or
3rd party PoE network switches to distribute power
and data for the required layout.
The Entry conguration utility is used to remotely view and edit the settings stored within the Entry system
devices. Individual devices or groups can be updated.
To ensure the best user experience and lifetime of your product we recommend your system is using the latest
version of the Entry conguration utility by going here: <www.paxton.info/1907>
When using Entry, the following minimum software versions are required:
Paxton10 – v3.2 or higher
Net2 – v4.27 or higher
Entry – v2.20 or higher
How many monitors and panels can I run ?
Positioning the panel
The Entry system can operate with up to 100 panels and 1000 monitors.
In order to oer the best picture possible, it is advised where possible to avoid positioning the panel where
the background will be signicantly brighter than the subject. As with most cameras this can create a
silhouetting eect due to the under exposure caused by the bright backlighting.
In situations where this cannot be avoided, additional lighting local to the panel will help to balance out the
light and improve the exposure.
Where possible, it is recommended that the panel should be installed out of direct sunlight. Prolonged
exposure to the sun can cause the panel to heat up well in excess of its specied operating temperature.
Where this cannot be avoided, the use of a rain hood is recommended. 1
APN-1127-ZA
Entry
One door / One monitor
Entry can be installed as a standalone system using one control unit, one Entry panel and one monitor.
The Entry control unit provides PoE (Power over Ethernet) for the two units.
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton Net2 plus
2
APN-1127-ZA
Entry
Adding Entry to a Net2 system
This layout is by far the easiest to install but you will need to discuss the following points with the building
IT manager. The network must:
1. Be compatible with IPv4 & IPv6 standards.
2. Support PoE network power.
3. Have the required bandwidth to handle the additional trac.
4. Have the permission of the IT sta.
The Entry system can be fully integrated into a Net2 Access control system by simply adding panels and
monitors to the existing Net2 network.
The Entry units require PoE power from a Entry control unit or a third party PoE switch. The Net2 system must
be running v4.25 software or later.
Once a panel has been plugged into the network, it will ask for the serial number of the ACU that it is to be
associated, which must be located on the same TCP/IP network (shown above in red). Multiple panels can
run on the same network but require their own ACU for association.
All monitors plugged into the network will then communicate with the panel(s) . They just require a local ID
to be assigned so the correct one can be called from a panel.
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton
Net2 plus
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton
Net2 plus
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton
Net2 plus
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton
Net2 plus
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton
Net2 plus
Net2 Server PC
Network
3
APN-1127-ZA
Entry
Paxton10 Server
Network
Adding Entry to a Paxton10 system
The Entry system can be fully integrated into a Paxton10 system by simply adding panels and monitors to
the existing Paxton10 network.
The Entry units require PoE power from a third party PoE switch. The Paxton10 system must be running v3.2
software or later.
The Entry panel must be on the same TCP/IP network as the Paxton10 system. Multiple panels can run on the
same network and require their own door controller. The Entry panels will need to be bound to the Paxton10
system and setup in the Paxton10 software, for more information on this see AN0045
<www.paxton.info/4931> .
All monitors plugged into the network will then communicate with the panel(s). They require a local ID to
be assigned so the correct monitor can be called from a panel.
The layout below is by far the easiest to install, but you will need to discuss the following points with the
building IT manager. The network must:
1. Be compatible with IPv4 & IPv6 standards
2. Support PoE network power
3. Have the required bandwidth to handle the additional trac
4. Have the permissions of the IT sta
4
APN-1127-ZA
Entry
One door / Multiple monitors
Net2 Server PC
Entry extension switch
Entry control unit
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton Net2 plus
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton Net2 plus
Network
The Entry control unit has four PoE ports and one standard network port. The PoE ports can be used to
power panels or monitors. All ve network ports can be used for data to expand the network.
The system can be congured to call more than one monitor in a single location by giving them the same
monitor ID.
The Entry extension switch has ve ports that can be used to expand the network. 3rd party PoE and
standard switches may also be used within the network for power and data.
5
APN-1127-ZA
Entry
Very large systems can be congured using multiple panels and monitors.
Each panel must be associated with its own ACU located on the same network.
Multiple Doors / Multiple Monitors
Network
Net2 Server PC
Entry extension switch
Entry extension switch
Entry control unit
Entry control unit
Entry control unit
All the monitors on a single network can be called by any panel. You should therefore ensure that the ID or
Name that you give a monitor clearly states its location to help the visitor call the correct monitor.
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton
Net2 plus
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton
Net2 plus
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton
Net2 plus
0V
0V
0V
0V
N.C.
N.O
2
COM
N.C.
N.O
COM
Data/D0
Clock/D1
CAT5
RS485
0V
10
TX RX
100
Data/D0
Clock/D1
10/100 Ethernet
N.C.
N.O
COM
12V - 24V
12V
1
2
12V
LED
LED
LED
12V
LED
LED
LED
LED
EXIT
12V DC 12V DC
I
1
Paxton
Net2 plus
6
APN-1127-ZA
Entry
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Paxton APN-1127-ZA User manual

Type
User manual

Paxton APN-1127-ZA is an Entry system designed for easy installation using a single network cable to link the Entry units. It allows you to have video intercom functionality with a simple setup of entry panels, control units, and internal video monitors. The system can operate with up to 100 panels and 1000 monitors, making it suitable for large buildings or campuses. You can integrate it with a Paxton10 or Net2 system for access control, allowing you to grant entry to authorized personnel remotely.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI