Alloy POEGEM24T4SFP User manual

  • Hello! I am an AI chatbot trained to assist you with the Alloy POEGEM24T4SFP User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
POEGEM24T4SFPUserManual
1
POEGEM24T4SFP
24PortGigabitSNMPManagedPOE
Switchwith4PairedSFP/CopperPorts
UserManual
POEGEM24T4SFPUserManual
2
Version1.0.0.1August2009
ElectronicEmissionNotices _______________________________________________________ 6
AboutthisUserManual_____________________________________________________7
OverviewoftheUserManual________________________________________________7
1.Introduction____________________________________________________________8
1.1.OverviewofthePOEGEM24T4SFPSNMPManagedPOESwitch__________________ 8
1.2.Checklist_________________________________________________________________ 11
1.3.Features _________________________________________________________________ 11
1.4.FullViewofPOEGEM24T4SFP______________________________________________ 13
1.4.1.UserInterfacesontheFrontPanel(Button,LEDsandPlugs) __________________________ 13
1.4.2.ACPowersocketontheRearPanel________________________________________________ 14
1.5.OverviewoftheOptionalSFPmodules ______________________________________ 15
2.Installation____________________________________________________________17
2.1.StartingthePOEGEM24T4SFPSNMPManagedPOESwitch_____________________ 17
2.1.1.HardwareandCableInstallation__________________________________________________ 17
2.1.2.CablingRequirements___________________________________________________________ 19
2.1.2.1.CablingRequirementsforUTPPorts___________________________________________ 19
2.1.2.2.CablingRequirementsfor1000SX/LX/ZXSFPModules ___________________________ 19
2.1.3.ManagementoptionsavailablewiththePOEGEM24T4SFP ____________________________ 20
2.1.3.1.ConfiguringthePOEGEM24T4SFPthroughtheRS‐232serialport __________________ 20
2.1.3.2.ConfiguringthePOEGEM24T4SFPthroughtheEthernetPort ______________________ 22
3.OperationofWebbasedManagement_____________________________________24
3.1.WebManagementHomeOverview__________________________________________ 25
3.2.System___________________________________________________________________ 27
3.2.1SystemInformation_____________________________________________________________ 27
3.2.2.Account_______________________________________________________________________ 29
3.2.3.Time _________________________________________________________________________ 31
3.2.4.IPConfiguration________________________________________________________________ 33
3.2.5.LoopDetection_________________________________________________________________ 35
3.2.6.ManagementPolicy_____________________________________________________________ 36
3.2.7.SystemLog____________________________________________________________________ 38
3.2.8.VirtualStack___________________________________________________________________ 39
3.3.Port _____________________________________________________________________ 40
3.3.1Configuration __________________________________________________________________ 40
3.3.2.PortStatus ____________________________________________________________________ 42
3.3.3.SimpleCounter ________________________________________________________________ 45
3.3.4.DetailCounter _________________________________________________________________ 47
3.3.5.PowerSaving__________________________________________________________________ 50
3.4.VLAN ____________________________________________________________________ 51
POEGEM24T4SFPUserManual
3
3.4.1.VLANMode ___________________________________________________________________ 51
3.4.2.Tag‐basedGroup_______________________________________________________________ 53
3.4.3.Port‐basedGroup ______________________________________________________________ 55
3.4.4.Ports_________________________________________________________________________ 57
3.4.5.PortIsolation__________________________________________________________________ 59
3.4.6.ManagementVLAN _____________________________________________________________ 60
3.5.MAC _____________________________________________________________________ 61
3.5.1.MACAddressTable_____________________________________________________________ 61
3.5.2.StaticFilter____________________________________________________________________ 63
3.5.3.StaticForward_________________________________________________________________ 64
3.5.4.MACAlias_____________________________________________________________________ 66
3.5.5.MACTable ____________________________________________________________________ 67
3.6.POE______________________________________________________________________ 69
3.6.1.Configuration__________________________________________________________________ 69
3.6.2.Status ________________________________________________________________________ 71
3.7.GVRP ____________________________________________________________________ 73
3.7.1.Config ________________________________________________________________________ 73
3.7.2.Counter_______________________________________________________________________ 75
3.7.3.Group ________________________________________________________________________ 77
3.8.QoS(QualityofService)Configuration ______________________________________ 78
3.8.1.Ports_________________________________________________________________________ 78
3.8.2.QoSControlListConfiguration ___________________________________________________ 80
3.8.3.RateLimiters__________________________________________________________________ 86
3.8.4.StormControl _________________________________________________________________ 88
3.8.5.Wizard _______________________________________________________________________ 90
3.9.SNMP ___________________________________________________________________ 100
3.10.ACL____________________________________________________________________ 102
3.10.1.Ports_______________________________________________________________________ 102
3.10.2.RateLimiters________________________________________________________________ 104
3.10.3.AccessControlList ___________________________________________________________ 105
3.10.4.Wizard _____________________________________________________________________ 133
3.11.IPMACBinding_________________________________________________________ 141
3.11.1.Configuration________________________________________________________________ 141
3.11.2.DynamicEntry_______________________________________________________________ 143
3.12.802.1xConfiguration____________________________________________________ 144
3.12.1.Server______________________________________________________________________ 148
3.12.2.PortConfiguration____________________________________________________________ 150
3.12.3.Status ______________________________________________________________________ 153
3.12.4.Statistics____________________________________________________________________ 154
3.13.TrunkingConfiguration _________________________________________________ 155
3.13.1.Port________________________________________________________________________ 156
3.13.2.AggregatorView _____________________________________________________________ 158
3.13.2.1LACPDetail______________________________________________________________ 159
3.13.3.AggregationHashMode_______________________________________________________ 161
POEGEM24T4SFPUserManual
4
3.13.4.LACPSystemPriority _________________________________________________________ 162
3.14.STPConfiguration_______________________________________________________ 163
3.14.1.Status ______________________________________________________________________ 163
3.14.2.Configuration________________________________________________________________ 165
3.14.3.Port________________________________________________________________________ 167
3.15.MSTPConfigurati on_____________________________________________________ 169
3.15.1.State _______________________________________________________________________ 169
3.15.2.RegionConfig________________________________________________________________ 170
3.15.3.InstanceView _______________________________________________________________ 171
3.16.Mirror_________________________________________________________________ 180
3.17.IGMP __________________________________________________________________ 182
3.17.1.IGMPMode__________________________________________________________________ 182
3.17.2.Proxy ______________________________________________________________________ 183
3.17.3.Snooping ___________________________________________________________________ 185
3.16.4.GroupMembership___________________________________________________________ 186
3.17.5.MVR _______________________________________________________________________ 187
3.17.6.MVID_______________________________________________________________________ 188
3.17.7.GroupAllow_________________________________________________________________ 189
3.17.7.GroupAllow_________________________________________________________________ 189
3.17.8.MVRGroupMembership ______________________________________________________ 190
3.18.Alarm__________________________________________________________________ 191
3.18.1.Events______________________________________________________________________ 191
3.18.2.Email_______________________________________________________________________ 194
3.19.DHCPSnooping_________________________________________________________ 195
3.19.1.DHCPSnoopingState _________________________________________________________ 195
3.19.2.DHCPSnoopingEntry_________________________________________________________ 196
3.19.2.DHCPSnoopingClient_________________________________________________________ 198
3.19.2.DHCPSnoopingClient_________________________________________________________ 198
3.20.Save/Resto re___________________________________________________________ 199
3.20.1.FactoryDefaults _____________________________________________________________ 199
3.20.2.SaveStart___________________________________________________________________ 200
3.20.3.SaveUser ___________________________________________________________________ 201
3.20.4.RestoreUser ________________________________________________________________ 202
3.21.Export/Import__________________________________________________________ 203
3.22.Diagnostics_____________________________________________________________ 204
3.22.1.Diag________________________________________________________________________ 204
3.22.2.Ping________________________________________________________________________ 205
3.23.Maintenance ___________________________________________________________ 206
3.23.1.ResetDevice_________________________________________________________________ 206
3.23.2.FirmwareUpgrade ___________________________________________________________ 207
3.24.Logout_________________________________________________________________ 208
4.OperationofCLIManagement___________________________________________209
POEGEM24T4SFPUserManual
5
4.1.CLIManagement _________________________________________________________ 209
4.2.CommandsoftheCLI_____________________________________________________ 210
4.2.1.GlobalCommands _____________________________________________________________ 212
4.2.2.LocalCommands______________________________________________________________ 218
AppendixATechnicalSpecifications_______________________________________357
AppendixBNullModemCableSpecifications________________________________362
POEGEM24T4SFPUserManual
6
Caution
ElectronicCircuitdevicesaresensitivetostaticelectricity.Dryweatherconditionsorwalkingacross
acarpetedfloormaycauseyoutoacquireastaticelectricalcharge.
Toprotectyourswitch,always:
Touchthemetalchassisofyourcomputertogroundthestaticelectricalchargebeforeyou
handle
theswitch.
Pickuptheswitchbyholdingitontheleftandrightedgesonly.
ElectronicEmissionNotices
FederalCommunicationsCommission(FCC)Statement
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAcomputingdevice
pursuanttoSubpartJofPart15
ofFCCRules,whicharedesignedtoprovidereasonableprotection
againstsuchinterferencewhenoperatedinacommercialenvironment.
EuropeanCommunity (CE)ElectromagneticCom patibilityDirective
ThisequipmenthasbeentestedandfoundtocomplywiththeprotectionrequirementsofEuropean
EmissionStandardEN55022/EN605552andtheGenericEuropeanImmunityStandard
EN500821.
EMC:
AustralianCTickCompliance
ThisequipmentiscompliantwiththerequiredAustralianCTickstandard.
EN55022(1988)/CISPR22(1985) classA
EN605552(1995) classA
EN605553
IEC100042(1995) 4KVCD,8KV,AD
IEC100043(1995) 3V/m
IEC100044(1995) 1KV(powerline),0.5KV(signalline)
POEGEM24T4SFPUserManual
7
AboutthisUserManual
ThisUserManualwillguideyouonprocedurestoinstall,configureandmonitortheAlloy24port
GigabitSNMPManagedPOESwitchutilisingthebuiltinwebmanagementinterfaceandalsotheCLI.
OverviewoftheUserManual
Chapter1“Introduction”describesthefeaturesofthePOEGEM24T4SFPGigabitSNMP
ManagedPOEswitch
Chapter2“Installation”
Chapter3“OperationoftheWebbasedManagement”
Chapter4“OperationoftheCLI”
Chapter5“Maintenance”
POEGEM24T4SFPUserManual
8
1.Introduction
1.1.OverviewofthePOEGEM24T4SFPSNMPManagedPOESwitch
ThePOEGEM24T4SFPfeatures20PoEcompliantportsrunningat10/100/1000Mbpsand4paired
10/100/1000MbpsCopper/miniGBIC(SFP)ports.ThePOEGEM24T4SFPisdesignedforhighport
densityPoEapplicationssuchasVoIPphonedeploymentorIPsecuritycameraenvironments.The
IntelligentLayer2SNMPmanagementfeaturesenablereliabletransportofcritical
VoIPandSecurity
data,evenincongestednetworkenvironments.VoIPrequiresprioritisationofVoiceCallsover
generalNetworkDataandSecuritysystemsrequirenotonlyprioritisation,butalsoportbasedlink
securityandreportingoflinkfailurestointelligentSNMPapplications.Theseandotherintelligent
networkfeaturesareallsupported
fromthePOEGEM24T4SFPswitch.
AllportsofthePOEGEM24T4SFPsupporttheIEEE802.3afPoEstandardforPowerInjection(PSE).
ThisinjectsPoEpowerontotheCat5eoraboveCablewhenitdetectsthepresenceofaPoE
compliantdevice.WhenoperatingwithnonPoEdevicestheswitchwillshutdown
thepower
injectingcircuitryandassuchnotcauseanydamagetoyournetworkdevices‐butstillallowthemto
runontheswitchasinthecaseofanormalEthernetdevice.
ThePOEGEM24T4SFPusesaninjectionvoltageofabout48VDConpins1,2,3,6
IntelligentNetworkfeatures
offeracompletemanagementsolutionthatcanenableyoutoscaleyour
networkfromasingledepartmentalswitchrightuptoanyEnterpriseenvironme nt.STP,RSTPand
MSTPoffernetworkredundancyfeatures,IGMPsnoopingofferssupportforStreamingVideoand
Multicastingimages,TaggedVLANofferslogicalsecurityandmanagementof
nodeswithindefined
groups.QOSbasedonportpriorityqueuesandTOSbytesensureefficientforwardingofcritical
networkdata.
TheSFPportscansupportthefollowingoptionalminiGBICmodulesforfibreopticcableconnections
(eithersinglemodeormultimodeterminatedinLCtypeconnectors):
1000Mbpsmultimode1000BaseSX,
850nm,max.range500m
1000Mbpssinglemode1000BaseLX,1310nm,max.range10Km
1000Mbpssinglemode1000BaseLHX,1310nm,max.range40Km
1000Mbpssinglemode1000BaseLHX,1550nm,max.range40Km
1000Mbpssinglemode1000BaseZX,1550nm,max.range70Km
1000Mbpssinglemode1000BaseEZX,
1550nm,max.range100Km
1000MbpsWDMsinglemode/singlecore1310nm,max.range20Km
1000MbpsWDMsinglemode/singlecore1550nm,max.range20Km
Notes: *ThetwoWDM(WaveDivisionMultiplexer)miniGBICmodulesare
designedtofacilitatealinkoverasinglecoreofsinglemodefibrecable.

 Thetwounitsmustbeusedinapairedmanner,oneateitherendofthelink.
*MiniGBICmodulesthataredesignedtotherelevantstandardsshouldbe
compatiblewithanymakeofswitchwithSFPports.Ifyouhaveconcerns
regardingcompatibility,pleasecontactthe
supplierofyourminiGBIC 
product.
POEGEM24T4SFPUserManual
9
The 10/100/1000Mbps copper ports meet all IEEE 802.3/u/x/z Gigabit and Fast Ethernet
specifications.
The1000MbpsSFPfibreportsviaoptionalminiGBICmodulesarecompliantwithallIEEE802.3zand
1000BaseSX/LX/LHX/ZX/EZXstandards.
1000MbpssinglefibreWDMtransceiversaredesignedwithanopticWavelengthDivision
Multiplexing(WDM)technologythat
transportsbidirectionalfullduplexsignalsoverasinglefibre
core.
KeyFeaturesofthePOEGEM24T4SFPSNMPManagedSwitch
QoS: These switches offer pow erful Quali ty of Service (QoS) functions. QoS support is
important for realtime applications based on information taken from Layer 2 to
Layer4,suchas
VoIP.
STP: Theseswitchesoffer802.1D‐STP,802.1w‐RSTPand802.1s‐MSTPspanningtree
protocols.
VLAN: All switch models support Portbased VLAN and IEEE802.1Q Tagged VLAN, with
supportfor256activeVLANshavingVLANID’sfrom1to4094.TheVLANfeaturein
the switch offers the benefits of
both security and performance. VLAN is used to
isolate traffic between different users and thus provides better security. Limiting
the broadcast traffic to within the same VLAN broadcast domain also enhances
performance.
PortTrunking:Allows one or more links to be aggregated together to form a Link Aggregation
Group.Up
to12Gigabitportscanbesetuppertrunk,andaswitchcansupportup
to 12 trunking groups. Port trunks are useful for switchtoswitch cascading,
providing very high fullduplex connection speeds. Both static and LACP based
trunkingmethodsaresupported.
PortMirroring: Portmirroringcopies
trafficfromaspecificportto atargetport.Thismechanism
helps track network errors or abnormal packet transmission without interrupting
theflowofdata.
Bandwidth Both models support bandwidth allocation rating on a per
Control: port basis. Ingress and egress throughput can be limited to a preset

levelappropriatetothetrafficgenerallyhandledonaspecificport.
PortSecurity: Devicescanbeallowed/deniedaccessbasedonMACaddressonaperportbasis.
SNMP/RMON: SNMPisusedtoremotelymonitorandconfigureSNMPawaredevicesfroma
centralSNMPmanagementdevice,suchasSNMPsoftware.
RMON
istheabbreviationofRemoteNetworkMonitoringandisabranchofthe
SNMPMIB.
AllswitchmodelssupportMIB2(RFC1213),BridgeMIB(RFC1493),RMONMIB
(RFC1757)statisticsGroup1,2,3,9,VLANMIB(802.1 Q,RFC2674),EthernetMIB
(RFC1643)andsoon.
IGMPSnooping: IGMPSnoopingprovidesa
methodforintelligentforwardingofmulticastpackets
withinaLayer2broadcastdomain.BysnoopingIGMPregistrationinformation,a
distributionlistofworkstationsisformedthatdetermineswhichendstationswill
POEGEM24T4SFPUserManual
10
receivepacketswithaspecificmulticastaddress.AllGSMswitchessupportIGMP
version2(RFC2236).
IGMPProxy: TheimplementationofIPmulticastprocessing.TheGSMSeriessupportsIGMP
version1andIGMPversion2,efficientuseofnetworkbandwidth,andfast
responsetimeforchannelchanging.Hostsinteract
withthesystemthroughthe
exchangeofIGMPmessages.Similarly,whenyouconfigureIGMP proxy,the
systeminteractswithamulticastawarerouteronitsupstreaminterfacethrough
theexchangeofIGMPmessages.However,whenactingastheproxy,thesystem
performsthehostportionoftheIGMPtaskonthe
upstreaminterfaceasfollows:
Whenqueried,sendsgroupmembershipreportstothegroup.
Whenoneofitshostsjoinsamulticastaddressgrouptowhichnoneofits
otherhostsbelong,sendsunsolicitedgroupmembershipreportstothatgroup.
Whenthelastofitshostsinaparticularmulticastgroupleavesthegroup,
sendsanunsolicitedleavegroupmembershipreporttotheallroutersgroup
(244.0.0.2).
Note: *SeeAppendixATechnicalSpecifications”forfurtherdetails
POEGEM24T4SFPUserManual
11
1.2.Checklist
Beforeyoustartinstallingyourswitch,verifythatthepackagecontainsthefollowing:
APOEGEM24T4SFPGigabitSNMPManagedPOESwitch
MountingAccessories(for19”RackShelfmounting)
ThisUsersManualCDROM
RS232SerialCable
ACPowerCord
Pleasenotifyyoursupplierimmediatelyifany
oftheaforementioneditemsaremissingordamaged.
1.3.Feat ures
TheAlloyPOEGEM24T4SFPSwitchprovidesacomprehensiverangeoffeatures:
Hardware
24x10/100/1000MbpsIEEE802.3afCompliantPOEPorts
4x10/100/1000MbpsTPor1000MbpsSFPFibredualmediaautosensingports
1392KBonchipframebuffer
Supportjumboframeupto9600bytes
ProgrammableclassifierforQoS(Layer4/Multimedia)
8KMACaddressand4KVLANsupport(IEEE802.1Q)
Perportshaping,policing,andBroadcastStormControl
IEEE802.1QQinQnestedVLANsupport
Fullduplexflowcontrol(IEEE802.3x)andhalfduplexbackpressure
ExtensivefrontpaneldiagnosticLED's;System:Power,TPPort124:LINK/ACT,
10/100/1000Mbps,POE,SFPPort2124:SFP(LINK/ACT)
POEGEM24T4SFPUserManual
12
Management
Supportsdetailedportstatisticsandeasyportconfiguration
Supportsperporttrafficcounters
SupportsasnapshotofthesystemInformationwhenyoulogin
Supportsportmirrorfunctionwithingress/egresstraffic
Supportsstatictrunkfunction
Supports802.1QVLAN
Supportsusermanagementandlimitsthreeuserstologin
Maximumpacketlengthofupto9600bytesforjumboframeapplications
SupportsDHCPBroadcastSuppressiontoavoidnetworkcongestion
Supportssendingoftrapeventsbasedonparticularactions
Allowsdefaultconfigurationtoberestoredincaseofconfigurationissues
SupportsHotSwappingofMiniGBICmodules
SupportsQualityofService(QoS)forrealtimeapplicationsbasedontheinformationtaken
fromLayer2toLayer4,suchasVoIP
BuiltinwebbasedmanagementandCLImanagement,providing amoreconvenientUser
Interfacefortheuser
SupportsSpanningTreeProtocolsSTP,RSTPandMSTP
Supports802.1XportsecurityonaVLAN
SupportsIPMACPortBindingforLANsecurity
SNMPaccesscanbedisabledandpreventfromillegalSNMPaccess
SupportsIngress,NonunicastandEgressBandwidthratingmanagementwitharesolutionof
1Mbps
Supportsloopdetectiontoprotecttheswitchfromcras hingwhenthenetworkhasaloop
issue
HTTPandTFTPforfirmwareupgrade,systemloguploadandconfigurationfileimport/export
SupportsNTPnetworktimesynchronizationanddaylightsaving
POEGEM24T4SFPUserManual
13
1.4.FullViewofPOEGEM24T4SFP
Figure1.1
1.4.1.UserInterfacesontheFrontPanel(Button,LEDsandPlugs)
Figure1.2FrontviewofP OEGEM24T4SFP
RESET Button:
RESET button is used
to
r
eset
t
h
e
Gigabit Ethernet POE Port
SFP Fibre Port
RS-232 DB-9 Connector
Power Indication LED
Port Status Indication LEDs
POEGEM24T4SFPUserManual
14
LedIndicators
LED Color Function
SystemLED
POWER Green Litwhen+5VDCpowerison
10/100/1000EthernetTPPort1to24 LED
LINK/ACT Green
Litwhenconnectionwithremotedeviceisgood
Blinkswhenanytrafficispresent
Offwhencableconnectionisnotgood

10/100/1000Mbps
Green/
Amber
Litgreenwhen1000Mbpsspeedisactive
Litamberwhen100Mbpsspeedisactive
Offwhen10Mbpsspeedisactive
1000SX/LXGigabitFibre Port21 24LED
SFP(LINK/ACT) Green
Litwhenconnectionwiththeremotedeviceisgood
Blinkswhenanytrafficispresent
Offwhenmoduleconnectionisnotgood
POELED
POE Green
LitwhenconnectionwithPOEPowerisenabled
BlinkswhenPOEPowerispresent
OffwhenPOEPowerisinactive
1.4.2.ACPowersocketontheRearPanel
Figure1.3RearviewofPOEGEM24T4SFP
AC Line 100-240V 50/60 Hz
POEGEM24T4SFPUserManual
15
1.5.OverviewoftheOptionalSFPmodules
WiththePOEGEM24T4SFPswitch,theSFPportsarepairedwithRJ45copperports21to24.Only
oneofanygivenpairedportcanbeused.Inthismanner,thesepairedportscanbeseenas‘Dual
Media’portsthatsupport10/100/1000Mbpsor1000MbpsfibreviatheSFPinterfaces.
Optional
1000MbpsminiGBICfibretransceivermodulescanbeusedforhighspeeduplink
connectionstofibrebackbonesorservers,wheninstalledintheSFPports.ArangeofoptionalAlloy
miniGBICmodulesareavailable:
AlloyPartNo. Description
MGBICT
1000Mbps,miniGBIC,Copper,100metres
MGBICMLC
1000Mbpsmultimode1000BaseSX,850nm,max.range500m
MGBICSLC10
1000Mbpssinglemode1000BaseLX,1310nm,max.range10Km
MGBICSLC4013
1000Mbpssinglemode1000BaseLHX,1310nm,max.range40Km
MGBICSLC4015
1000Mbpssinglemode1000BaseLHX,1550nm,max.range40Km
MGBICSLC70
1000Mbpssinglemode1000BaseZX,1550nm,max.range70Km
MGBICSLC120
1000Mbpssinglemode1000BaseEZX,1550nm,max.range120Km
MGBICSLC200
1000Mbpssinglemode1000BaseEZX,1550nm,max.range200Km
MGBICWDMS3.20
1000MbpsWDMsinglemode/singlefibre1310nm,max.range20Km
MGBICWDMS3.20
1000MbpsWDMsinglemode/singlefibre1550nm,max.range20Km
MGBICWDMS3.40
1000MbpsWDMsinglemode/singlefibre1310nm,max.range40Km
MGBICWDMS3.40
1000MbpsWDMsinglemode/singlefibre1550nm,max.range40Km
MGBICCWDM40
1000MbpsCWDMsinglemode/singlefibre1470nm1610nm,max.range
40Km
MGBICCWDM70
1000MbpsCWDMsinglemode/singlefibre1470nm1610nm,max.range
70Km
Notes: *TheWDM(WaveDivisionMultiplexer)miniGBICm o dulesare
designedtofacilitatealinkoverasinglecoreofsinglemodefibrecable.
Thetwounitsmustbeusedinapairedmanner,oneateitherendofthelink.
*MiniGBICmodulesthataredesigned
totherelevantstandardsshouldbe
compatiblewithanymakeofswitchwithSFPports.Ifyouhaveconcerns
POEGEM24T4SFPUserManual
16
regardingcompatibility,pleasecontactthesupplierofyourminiGBIC
product.
*Theinformationgiveninthetableaboveiscurrentattimeofpublication;
availabilityofindividualAlloyminiGBICmodulesmayvaryovertime.
Fig.1.5FrontViewof1000Base
SX
/
LXLC
,
SFP Fibre Transceive
r
Fig. 1.6 Front View of 1000Base-LX
WDM LC, SFP Fibre Transceiver
POEGEM24T4SFPUserManual
17
2.Installation
2.1.StartingthePOEGEM24T4SFPSNMPManagedPOESwitch
Thissectionprovidesaquickstartguidefor:
HardwareandCableInstallation
ManagementStationInstallation
Softwarebootingandconfiguration
2.1.1.HardwareandCableInstallation
PleaseNote:
Wearagroundingstraptoavoiddamagingtheswitchwithelectrostaticdischarge
Besurethatthepowerswitchisinthe‘OFF’positionbeforeyouinsertthepowercord
InstallingOptionalSFPMiniGBICModules
ConnectingtheSFPMiniGBICModul etotheChassis:
TheoptionalSFPMiniGBICmodulesarehotswappable,soyoucanplug orunplugthemwhilethe
powerisappliedtotheswitch.
1. VerifythattheminiGBICmoduleis compatiblewiththeSFPportonthe
switch(forexample,
someswitchmanufacturersdesigntheirminiGBICmodulestobeoperableonlyintheirbranded
devices).
2. VerifythatthetypeofminiGBICyouhaveselectedforusewillbecompatiblewiththe
typeoffibreopticcablethatistobeused.
3. Verifythat
thetypeofminiGBICyouhaveselectedforusewillbecompatiblewiththe
fibreoptictransceiverattheotherendofthelink(e.g.compatiblewavelengthandstandard).
4. SlidethemodulealongtheslotandensurethatthemoduleisproperlyseatedagainsttheSFP
slot
socket/connector.
5. Installthemediacablefornetworkconnection.
6. Repeattheabovesteps,asneeded,foreachmoduletobeinstalledintotheswitch.
Fig.2.1:InstallationofoptionalSFPminiGBICmodul es
SFP
p
ort
Mini-GBIC module
POEGEM24T4SFPUserManual
18
CopperPorts‐CableInstallation
PleaseNote:
TheRJ45portsontheAlloyPOEGEM24T4SFPSwitchsupportsMDI/MDIXautocrossover
functionality.This enablesuseofeitherstraightthroughorcrossoverUTPcable
types;theRJ45portswillautomaticallybeconfiguredtosuitthecharacteristicsof
thedevice
attheremoteendofthelink.
TheRJ45portsontheAlloyPOEGEM24T4SFPSwitchsupportNwayautonegotiation;the
portswillautomaticallybeconfiguredtobecompatiblewiththespeedandduplex
settingsofthedeviceattheremoteendofthelink.
TheminimumgradeofcableforusewiththeswitchisCat.5gradeUTPorSTP.Higher
gradesofUTP/STPcablemayalsobeusedtoconnecttothecopperRJ45ports.
1. DepresstheclipontheRJ45connectorandpushintotheRJ45
port.Releaseconnectorand
ensurethatthecableconnectoris securelylocke dintotheRJ45port.
2. Repeattheabovesteps,asneeded,foreachRJ45porttobeconnected.
PowerOn
PleaseNote:
TheAlloy
POEGEM24T4SFP Switchusesa100240VAC,5060Hzpowersupply.Thepowersupply
willautomaticallyconvertyourlocalACpowersourcetoDCpowerforusebytheswitch.
1. Ensurethatthepowerswitchisturnedoffbeforeconnectingmainspower.
2. Connectthepowercordsuppliedwiththe
switchtoyournearestmainsoutlet.
3. ConnecttheotherendofthepowercordintotheIECpowerportontheswitch.
4. LockthepowercableintoplaceusingthepowercableclampmountedontheIECpowerport.
5. Turntheswitchon.
6. Wheninitialpower
isapplied,alltheLEDindicatorswilllightupforabriefperiodwhilethe
systemperformsitsstartuptests.Oncetheinitialtests(‘POSTtest’)havecompletedallexceptthe
powerLEDshouldreturntoanoffstate.
FirmwareLoading
Afterpoweron,thebootloaderwillload
theswitchfirmwareintothemainoperationalmemory.
Thisprocess willtakeabout30seconds.Oncecompleted,theswitchwillflashalltheLED’sonceand
thenswitchtoareadystate.
POEGEM24T4SFPUserManual
19
2.1.2.CablingRequirements
Tohelpensureasuccessfulinstallationandkeepnetworkperformanceatoptimuml evels,takecare
touseCat.5egradeorhighercabling.EnsurethatstrandedcoreUTPcable,ifused,runsfornomore
than10metres,andthatsolidcorerunsforamaximumof100metres.Poorcablingis
themost
commoncausefornetworkdropoutsorpoorperformance.
2.1.2.1.CablingRequirementsforUTPPorts
ForEthernetcoppernetw orkconnections,theUTPcableusedmustbeCat.3gradeasa
minimum,withamaximumlengthof100metres
ForFastEthernetcoppernetworkconnections,theUTPcableused mustbeCat.5gradeasa
minimum,withamaximumlengthof100metres

ForGigabitEthernetcoppe rnetwork connection,UTPcableusedmustbeCat.5gradeorhigher,
withamaximumlengthof100metres.Cat.5egradeUTPcableisrecommended.
2.1.2.2.CablingRequirementsfor1000SX/LX/ZXSFPModules
Therearetwocategoriesoffibreopticcable‐multimode(MM)andsinglemode(SM).Thelateris
categorisedintoseveralclassesbythedistanceitsupports.TheseareSX,LX,LHX,ZXandEZX.The
majorityofminiGBICmodulesavailableuseaLCtypeconnector.Theconnectortypesusedcurrently
onAlloyminiGBICmodulesareLCandWDMSC,forthefollowingmoduletypes:
GigabitFibrewithmultimodeLCSFPminiGBICmodules
GigabitFibrewithsinglemodeLCminiGBICmodules
GigabitFibrewithsinglemode/singlecoreWDMSC1310nmSFPminiGBICmodules
GigabitFibrewithsinglemode/singlecoreWDMSC1550nmSFPminiGBICmodules
ThefollowingtableliststhetypesoffibreopticcablethataresupportedbySFPminiGBICmodules
installedinAlloyPOEGEM24T4SFP.Othercabletypesnotlistedheremaybesupported;please
contactthesupplierofyour
switchfordetails.
IEEE802.3zGigabitEthernet1000SX
850nm
MultimodeFibreCableandModalBandwidth
Multimode2.5/125
μ
m Multimode50/125μm
Modal Range Modal Range
160MHzKm 220m 400MHzKm 500m
200MHzKm 275m 500MHzKm 550m
1000BaseLX/LHX/XD/ZX
SingleModeFibre9/125μm
SingleModetransceiver1310nm10Km,40Km
SingleModetransceiver1550nm40Km,70Km,100Km
1000BaseLXSingleFibre(WDMSC)
Singlemode
*20Km
TX(Transmit)1310nm
RX(Receive)1550nm
Singlemode
*20Km
TX(Transmit)1550nm
RX(Receive)1310nm
Cont.
POEGEM24T4SFPUserManual
20
PleaseNote:
Furtherinformationcanbefoundin section1.5
All figures denoting the range a given cable type can achieve must be treated as maximum
values.Anumberof variablescan limitthe actual rangethat can be achieved gradeof cable
used,qualityofcable,andpresenceofjoinsincableruns,forexample
2.1.3.ManagementoptionsavailablewiththePOEGEM24T4S FP
ThePOEGEM24T4SFPsupportsmultiplemanagementoptionstoallowadministratorstoquickly
configureandmonitortheswitchandnetworkperformance.Therearefourmanagementoptions
availableincludingRS232console,CommandLineInterface(CLI),SNMPorviathebuiltinWeb
Management.Thefollowingprocedureswillbrieflydescribehoweachmethod
canbeperformed
andwillalsobediscussedinmoredetai llaterinthismanual.
Section2131:ConfiguringthePOEGEM24T4SFPthroughtheRS232serialport.
Section2132:ConfiguringthePOEGEM24T4SFPthroughtheEthernetport.
2.1.3.1.ConfiguringthePOEGEM24T4SFPthroughtheRS232serialport
WhenconfiguringthePOEGEM24T4SFPviatheRS232consolepleaseconnecttheswitchviathe
providedserialcabletoaDCEdevicesuchasaPC.Onceyouhaveconnectionrunaterminal
emulationprogra msuchasHyperTerminal.Whenconnectingtotheswitchpleaseusetheserial
settingsofthe
switchtocreatetheconnection,thedefaultsettingsarebelow:
BaudRate:115200
DataBits:8
Parity:None
StopBits:1
FlowControl:None
BypressingEnteryouwillnowbepromptedtologintotheswitch.
Thedefaultusernameandpasswordfortheswitchis:
Username:admin
Password:admin
TheRS232consoleportontheswitchismainlyusedfortheinitialsetupoftheswitchincluding
settingtheIPAddress,SubnetMaskandGate way.Itisrecommendedthatallothermanagement
dutiesthatneedtobeperformedshouldbedoneviatheWebManagementorCLI.
/