Mountz MDC Tpm Operation Manual

Type
Tpm Operation Manual

This manual is also suitable for

TPM Operation Manual
Revision 1.1
July 17, 2017
Parameter setting, monitoring and auto data memory for MDC & ADC
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
1
Index
1. Main feature
3
2. Specification
3
3. Operation
4
3.1 Connection
4
3.2 Menu
5
3.2.1 Standard menu
5
3.2.2 Setting menu
7
1) Extended 99 pesets
7
2) Extended 99 models
8
3) Communication
9
4) Barcode
11
5) I/O
12
4. Layout drawing
15
5. Data memory in SD card
16
6. Firmware & UI graphic file upgrade
17
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
2
1. Main features
- Parameter setting & monitoring same as ParaMon PC software
- Extended 99 Presets and Models
- Data auto saving in file system. One file a day / monthly folder, yearly folder
- Barcode scanner available to call preset or model
- Available for MDC or ADC ( two models )
- 8” TFT LCD with touch screen
2. Specification
Item Description Remark
Power supply AC100-240V~ 50/60Hz, 1.5A AC-DC adapter SW24
Input power DC24V, 1A
Size 207(W) 160 (H) 52 (D)
Weight 1.2 Kg
Display
8 TFT LCD with touch screen
COM port
2 - RS232C (MDC & Barcode scanner)
2 - RS422 (ADC IN & OUT)
1 - USB
1 - Ethernet
Digital I/O
8 - Inputs
6 - Outputs
Program
99 - extended Presets
99 - extended Models
** Preset, screw number, I/O & time
managing in 10 step process
Programs are saved in
ParaMon Touch
Memory
8 GB SD card.
Auto fastening data saving.
Auto file and folder creating
One file a day. Monthly and
yearly folder
** Standard packing
**
1 x ParaMon Touch, 1 x 24VDC adapter
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
3
3. Operation
3.1 Connection
ParaMon Touch is connected to MDC or ADC controller as below.
MDC controller : Serial RS232C
ADC drive : Serial RS422
The COM port connection requires the information about COM port, Baud rate and the
device ID
ParaMon Touch - MDC
ParaMon Touch - ADC
SD memory card
Mini USB
No use
24V DC, 1A
Ethernet
RS422 (ADC)
RS422 (Not used)
RS232C-1 (MDC)
RS232C-2 (Scanner)
I/O
2 X RS422
2 X RS232
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
4
2
x RS232 2 x RS422
There are two RS232C ports on the back side of ParaMon Touch.
# RS232C-1 : Labeled as SENSOR. It is connected to the MDC controller
To activate RS232C-1 port, select RS232 on Communication1 menu
# RS232C-2 : Labeled as RS232. It is connected to the barcode scanner
To activate RS232C-2 port, select RS232 on Communication2 menu
There are two RS422 ports on the side of ParaMon Touch.
# RS422-1 : Labeled as DR1. It is connected to the ADC controller
To activate RS232C-1 port, select RS232 on Communication1 menu
# RS422-2 : Labeled as DR2. Not used
To activate RS232C-2 port, select RS422 on Communication2 menu
RS232C – MDC
RS232C – Scanner
ADC Spindle drive
switchable
2 X RS422
2 X RS232
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
5
3.2 Menu
There are 2 group of menu.
3.2.1 Standard menu Parameter, Monitoring & Remote
Use the operation manual of MDC or ADC
Standard MD parameter
setting
& monitoring
1. Extended 99 Presets
2. Extended 99 Models
3. Barcode scanner sett
i
ng
4.
A
uto data saving on SD card
5.
ParaMon
T
ouch I/O
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
6
3.2.2 Setting Menu
1) Extended 99 presets
There are total 99 presets with 15 standard parameter settings. These presets are
saved in ParaMon Touch itself, not in the MDC controller. Whenever the preset is
selected from 99 presets, it replaces parameters on the Preset #1 of the MDC
controller via RS232C.
The extended Preset menu is effective only with two parameter settings below
Setting > Mode : Preset / Extended setting enable : YES
Click to select the number of preset
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
7
2) Extended 99 Models
There are total 99 models with 10 standard steps. These models are saved in
ParaMon Touch itself, not in the MDC controller. Whenever the Model is selected
from 99 models, it replaces settings on the Model #1 of the MDC controller via
RS232C.
The extended Preset menu is effective only with two parameter settings below
Setting > Mode : Model / Extended setting enable : YES
Click to select the number of Model
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
8
3) Communication
The communication menu manages two RS232C & RS422 ports. One works for
connecting to MDC or ADC controller (DR1 & SESNOR). The other works for
Barcode scanner or any other device ( DR2 & RS232 )
Communication 1 > Type : RS232 for MDC (labeled SENSOR)
or RS422 for ADC (labeled DR1).
2 X RS422
2 X RS232
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
9
Communication 2
> Enable : YES / Type : RS232 or RS422
To connect the RS232 Barcode scanner, select type RS232. And select the same
baudrate with the barcode scanner. To connect the RS422 barcode scanner, select
type RS422 and ID number.
2 X RS422
2 X RS232
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
10
4) Barcode
Once Communication 2 was done with proper setting for the connected barcode
scanner, Barcode menu is available to be programed.
1) Key in the Preset or Model number to be selected
2) Key in the barcode data address
3) Click READ and scan the barcode
4)
Select the digit number for starting and ending from the rea
d data
Barcode data : P X C H 2 0 4 5 A 9 8 4 6 3 0 6 4 2 ( example )
Start : 5 End : 7 Selected data : 204
1
Click to select the number of preset
1 2 3 4 5 6 7 8 9 10 11 12 Digit number
2
3
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
11
5) I/O setting
There are 8 inputs and 6 outputs.
Pin No Description Factory setting
1 IN 1 Preset / Model #1
2 IN 2 Preset / Model #2
3 IN 3 Preset / Model #3
4 IN 4 Preset / Model #4
5 IN 5 Preset / Model #5
6 IN 6 Preset / Model #6
7 IN 7 Preset / Model #7
8 IN 8 -
9 X
10 OUT 1 Ready
11 OUT 2 Alarm
12 OUT 3 -
13 OUT 4 -
14 OUT 5 -
15 OUT 6 -
16 X
17 X
18 X
19 X
20 X
21 Out COM
22 In COM
23 X
24 X
25 X
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
12
25P I/O schematic
Pin 10
Pin 11
Pin 12
Pin 13
Pin 14
Pin 15
Output #1
Output #2
Output #3
Output #4
Output #5
Output #6
Pin 21
Output com
24V 100mA max.
Input #1
Input #2
Input #3
Input #4
Input #5
Input #6
Input #7
Input #8
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 22
Input com
24V
25P D-Sub connector
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
13
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
14
4. Layout drawing
6 - M3, 6mm depth hole for mounting
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
15
5. Data memory in SD card
All fastening data is automatically saved in the SD card.
To read the saved data, remove the SD card and read them in the PC.
The SD card have the following folder and file system
SD card >
History >
2017 (year) >
07 (month) >
17.csv ( file name with the number of date )
6.
Firmw
are
& UI graph
ic file update
[ Firmware upgrade ]
Make folder name of update on the root of the SD card.
Copy the firmware file into the update folder.
Power ON the ParaMon Touch after inserting of SD card.
Then the system will detect the update folder and start updating
the firmware automatically
SD card >
update >
MD_ParaMonTouch.bin ( firmware file for MDC )
AD_ParaMonTouch.bin ( firmware file for ADC )
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
16
[ UI graphic file upgrade ]
Save all the graphic files into the following folder name in SD card.
Folder name : DWIN_SET
Open the top frame of the ParaMon Touch by loosening 3 screws on top
And two screws on both top side.
Power ON the ParaMon Touch after inserting of SD card.
Then the system will detect the UI graphic folder and start upgrading the graphic files
automatically. After upgrading the files, Power OFF and remove the SD card.
SD card >
DWIN_SET >
Jpg files
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
17
www.mountztorque.com - 1080 N 11th St - San Jose CA 95112 - 408.292.2214
18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Mountz MDC Tpm Operation Manual

Type
Tpm Operation Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI