  • Hello! I am an AI chatbot trained to assist you with the Hitachi L300P Series Engineering Note. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PGC - 10/23/01 Page 1 of 1
Hitachi America, Ltd.
EN-102301-1
ENGINEERING NOTE
SUBJECT: CAUTIONS!! ANALOG INPUT FUNCTION
AFFECTED MODELS: ALL SJ300 AND L300P
If the value of parameter A001 (Frequency Source Selection) is set to “01”
(terminal)
- AND -
the AT function (data=16) is NOT assigned to any of the intelligent input
terminals, the function of the “O2” analog input terminal will be as described in
the table below:
Value of Parameter
A006 (O2 Selection)
Action of Analog Inputs
00 ( Independent)
Only the signal at the O2 terminal will reflected.
Terminals O and OI will be disabled. When the signal at
O2 becomes negative, the speed reference becomes
negative, resulting in REVERSE direction of rotation. The
action is the same when the multispeed terminal(s)
and/or the jog terminals are ON.
01 (Only Positive)
The speed reference will be the SUM of O+OI+O2. When
the sum is negative, speed will be ZERO.
02 (Both Positive and
Negative
The speed reference will be the SUM of O+OI+O2. When
the sum is negative, the speed reference becomes
negative, resulting in REVERSE direction of rotation. The
action is the same when the multispeed terminal(s)
and/or the jog terminals are ON
Summary: In the case where the AT function is not assigned to any input
terminal, and REVERSE rotation is not desired or unsafe, make sure that A006 is
set to a value of “01”.
/