Wolf MGK-300 Operating Instructions Manual

Type
Operating Instructions Manual

This manual is also suitable for

Wolf MGK-300

Below you will find brief product information for Wolf MGK-300:

The Wolf MGK-300 is a gas condensing boiler that is part of a range of high-grade products that incorporate the latest safety technology, such as frost protection and balanced flue routing. It is suitable for installation in rooms that are free from the risk of frost, and comes with a 2-year warranty period and requires an annual service.

Wolf MGK-300

Below you will find brief product information for Wolf MGK-300:

The Wolf MGK-300 is a gas condensing boiler that is part of a range of high-grade products that incorporate the latest safety technology, such as frost protection and balanced flue routing. It is suitable for installation in rooms that are free from the risk of frost, and comes with a 2-year warranty period and requires an annual service.

Document no. 3062881_0910 Subjecttotechnicalmodications
Operating instructions
Gas condensing boilers
MGK-130
MGK-170
MGK-210
MGK-250
MGK-300
GB
Wolf GmbH · Postfach 1380 · D-84048 Mainburg · Tel. +49 8751/74-0 · Fax +49 8751/741600 · Internet: www.wolf-heiztechnik.de
2
3062881_0910
Contents
Contents ..............................................................................................................................................Page
Warranty / General information .................................................................................................................. 2
Safetyinstructions ...................................................................................................................................... 3
Installationinformation/Maintenanceinformation ..................................................................................... 4
Waterconnectionsandgassupplyconnection .......................................................................................... 5
Controlunitoperation ................................................................................................................................. 6
Informationforenergyefcientoperation/Faults ................................................................................... 7-8
General information Gasisanenvironmentallyfriendlyfuelthatdoesnotrepresentanydanger
unlesshandledwithgrossnegligence.Yourgascondensingboilerisa
highgradeproductthatincorporatesthelatestsafetytechnology.
Warranty period Gascondensingboilersareguaranteedfor2years.
Warranty Our warranty is subject to the installation being carried out by a
recognised heating contractor and adherence to all operating and
installationinstructions.
These safety instructions should protect you from
potential risks.
• Immediately switchOFF the emergencystop switch ofthe heating
system(ifoutsidetheinstallationroom).
• Closethegasshut-offvalve.
• Incaseofre,useasuitablereextinguisher.
In case of risk of re
Non-observance of these references can lead to risks to
individuals and the risk of material losses.
Risk to life!
3
3062881_0910
Safety instructions
Balanced ue routing Withlowoutsidetemperatures,thewatervapourcontainedintheuegas
maycondenseandfreezeonthebalancedue.This ice may fall from
the roof causing injury or material losses.Preventicefromfallingby
takingon-sitemeasures,e.g.theinstallationofasnowguard.
Caution - risk of injury!
Frost protection Theuseofantifreezeisnotpermissible.
Thecontrolunitprotectsthegascondensingboileragainstfrost.Therisk
offrostcannotbetotallyprevented,e.g.duringlongerpowerfailures.
Thereforeonlyinstallthegascondensingboilerinroomsthatarefree
fromtheriskoffrost.Shouldtherebeariskoffrostduringlongeridle
periods,e.g.whentheheatingsystemisswitchedoff,askyourlocal
heatingcontractortodraintheboilerandtheheatingsystemtoprevent
pipesfrombursting.
Caution - risk of water damage and malfunction through
freezing.
When changing a fuse - Isolatetheappliancefromthepowersupplypriortochangingafuse.
Themainsterminalsoftheboilerare'live'evenwhentheON/OFF
switchhasbeenswitchedOFF.
Caution - risk of electrocution!
If you smell ue gas - Shutdownthesystem.
- Openwindowsanddoors.
- Notifyyourlocalcontractor.
Caution - risk of poisoning!
- Donotoperateanylightswitch.
- Donotoperateanyelectricalswitches.
- Keepnakedamesaway.
- Closethegasshut-offvalve.
- Openwindowsanddoors.
- Notifyyourgassupplyutility;useatelephoneoutsideofthedanger
area.
Caution - risk of poisoning, suffocation and explosion!
If you smell gas
SAFETY INSTRUCTIONS
4
3062881_0910
Installation information /
Maintenance information
Care Cleanthecasingwithadampclothandmilddetergent.
Thecomponentsinsidethegascondensingboilermayonlybecleaned
byaheatingcontractor.
Corrosion protection Never use or store sprays, solvents, chlorinated cleaning agents,
paints, adhesives, etc. in the vicinity of the gas condensing boiler.
Underunfavourableconditions,thesematerialsmayleadtocorrosion
inthegascondensingboilerandtheuesystem.Ductedventsrouted
througha roofmay alsocontain corrosive vapours. For thatreason,
maintainasufcientlylargedistancetotheair/uegasterminal(minimum
recommendation:5m).
NB - only the heating contractor offers the required
knowledge and expertise!
- Theuserisresponsibleforarrangingaregularserviceofthesystem,
inordertoensurethereliableandsafefunctionofthegascondensing
boiler.
- Yourgascondensingboilershouldbeservicedannually.
- Maintenanceisexplicitlydetailedintheinstallationinstructions.
- Isolatetheappliancefromthepowersupplybeforeanymaintenance
work.
- Afteraserviceandbeforethegascondensingboilerisreturnedinto
use,checkthatallcomponentsthatwereremovedformaintenance
havebeenrettedcorrectly.
- Werecommendyouarrangeamaintenancecontractwithanapproved
heatingcontractor.
Service
Positioning / modications - Your gas condensing boiler should only be installed and modied
byanapprovedheatingcontractor,asonlytheyhavetheessential
knowledgetocarryoutsuchwork.
- Nevermodifyuegascomponents.
- Never close or restrict the ventilation apertures in doors or walls
when operating the boiler in open ue mode; only start the boiler
when the ue has been fully installed.
- For operation in balanced ue mode, only take the appliance into
use if the balanced ue system has been fully installed and the
wind protector is not covered up.
- Thegascondensingboilermayonlybeinstalledinroomsthatare
protectedfromfrost.
- Never isolate the appliance from the power supply when outside
temperaturesfallbelowzero,otherwisethereisariskofthesystem
freezingup.
- Nevermodifythedrainorthesafetyvalve.
Caution - failure to observe this rule may lead to a risk of re
as well as a risk of destruction, poisoning or explosion!
Do not use or store explosive and/or ammable materials, e.g.
petrol, thinners, paints, paper etc. inside the boiler room!
5
3062881_0910
Water connections and gas
supply connection
Checking the water level Regularly check the water level. The pressure gauge must indicate
between2.0and2.5bar.Yourheatingcontractorwillexplainhowtotop
upyoursystem.Donotsupplementyourheatingwaterwithadditives,
otherwisecomponentsmaybedamaged.
Filling the siphon Thesiphonmustbettedandlled.
Filling the system Connectawaterhosetotheboilerdrain&ll(BDF)valveandopenthe
mainswatertap.OpentheBDFvalvetoprovideamoderateowrateand
lltheheatingsystemtoapprox.1.5bar.Checkthewaterpressureatthe
pressuregauge.Ventthesystem.Theboilermustbetoppedup,since
heatingwaterwillonlyfullydeaerateafterseveralhours’heatingoperation.
Generallyleavethesystemfull-exceptwherethereisariskoffrost.
Theconnectionrequiredforllingbetweenthetapwaterandheating
watermust beremovedafterthellhasbeencompleted.Otherwise
thereisariskthatyourtapwaterwillbecontaminatedbyheatingwater.
The appliance may overheat if it is operated without water.
Please observe before
commissioning
Dependingonyourspecicheatingsystem,thesafetyequipment
mustbetestedbyaheatingcontractor.
Theheatingsystemmustbecompletelylledwithwater.Subjecttothe
boileroutputandoperatingtemperatureoftheheatingsystem,thewater
qualityforheatingsystemsisregulatedbylocalregulationsgoverning
"Waterqualityinheatingsystemswithhotwaterboilers".
Observethesystempressure.Ifnecessarytopupwithwater.
Neveruseboilerwaterfordomesticuse.
Checkwhethertheventilationoftheboilerroomisensuredinaccordance
withlocalregulations.
Theairsupplytotheboilermustnotbeobstructed,otherwise
there is a risk of suffocation.
Neverpositionobjectsdirectlyontheboiler-maintainaminimum
clearance of 40 cm. Otherwise there is a high risk of re.
If necessary top up with water. When lling the heatingsystem, the
shut-offvalvesmustbeopen.
6
3062881_0910
Control unit operation
Note:
TheBMprogrammingmodulecanalsobeintegratedintothecontrolunit.
ThatmeansthatallsettingsaremadeattheMGK.Forinstallationand
operation,seetheBMprogrammingmoduleoperatinginstructions.
ON/OFF
switch
DHW
temperature
selector
Pressuregauge
Resetbutton
Heatingwater
temperatureselector
Illuminated
ring
Thermometer
Illuminated status indicator ring
Illuminated ring Explanation
Flashinggreen Standby(powersupplyON,burnerOFF,e.g.summermode)
Constantgreenlight Wintermode:Pumprunning,burnerOFF
Flashingyellow Emissionstestmode
Constantyellowlight BurneroperatingameON
Flashingred Fault
Summer mode (centralheatingOFF)
Winter mode Setting2to8
Emissionstestmode (indicatorringashesyellow)
DHWtemperatureselector 1(15°C)...9(65°C) 7(55°C)recommendation
Heatingwatertemperatureselector 2(20°C)...8(75°C)
7
3062881_0910
Information for energy efcient operation
Heating mode Saving energy with modern heating technology: gas condensing
technology saves your cash
In conventional heating systems energy is expelled unused to the
atmosphere along with the ue gas. Modern condensing technology
utilisesthatenergyforheating.
Use as little electrical energy as possible
Operate your system with multi stage heating pumps at the lowest
requiredlevel.
Regular heating system maintenance pays for itself
A contaminated burner or poorly adjustedappliance canreduce the
heatingsystemefciency.Regularheatingsystemmaintenancethrough
yourlocalcontractorquicklypaysforitself.
Heating at the lowest energy level
Operateyourheatingsystem,wherepossible,withaowtemperature
oflessthan60°Coraatheatingcurve.
A heating system control unit also regulates your heating costs
Aheatingsysteminstandbymodesavesenergy.Withautomaticnight
setbackandthermostaticvalves,amodernweather-compensatedor
roomtemperature-dependentheatingsystemcontrolunitensuresthat
thesystemonlyoperateswhenheatisrequired,savingyoumoneythe
restofthetime.
- Equip your heating system with a weather-compensated heating
controllerfromtheWolfrangeofaccessories.Yourheatingcontractor
willbehappytoadviseyouhowtoachieveoptimumsettings.
- In conjunction with the Wolf control unit accessory, use the night
setback function to match the energy level to the actual demand
period.
- Usetheoptionalsummermodesetting.
Never overheat your system
Adjust the room temperatureas accuratelyas possible.This leaves
occupants comfortable and energy is not wasted on providing
heatingoutputthatnobodyneeds.Youcandifferentiatebetweenthe
optimumtemperaturesforindividualrooms,suchaslivingroomsand
bedrooms.
Aroomtemperaturethatisonedegreehigherthannecessaryrepresents
anadditionalenergyconsumptionofapprox.6%.
- Useroomthermostatstomatchtheroomtemperaturetotheactual
useoftheroom.
- Inany roomwhereyouhaveinstalleda room temperaturesensor,
openthethermostaticvalvefully.Thisenablesyoutoachieveoptimum
controlcharacteristicsforyourheatingsystem.
Ensure adequate air circulation
Air must be able tocirculate freely nearthe radiators andthe room
temperaturesensors,otherwisetheheatingsystemwillloseworkless
effectively.Badlypositionedlongcurtainsorfurniture"swallow"upto
20%ofyourheat.
8
3062881_0910
Information for energy efcient operation /
Faults
Keep the heat inside the room - at night too
Atnight,closingshuttersanddrawingcurtainsnoticeablyreducesheat
lossesviathewindowareas.Insulatingtheradiatorrecessesandhaving
lightcolouredpaintworkcansaveupto4%offyourheatingbills.Airtight
jointsatwindowsanddoorsalsohelptokeepenergyinsidetheroom.
Minimise energy consumption through sensible ventilation
Ventilatingforhourslosesheatstoredinwallsandobjects.Asaresult,the
roomclimatewillonlybecomecomfortableagainafterprolongedheating.
Shortandthoroughventilationismoreeffectiveandpleasant.
Bleeding the radiators
Bleedtheradiatorsregularlyineveryroom.Thissafeguardstheperfect
functionofradiatorsandthermostats,particularlyintheupperapartments
ofapartment blocks.The radiator respondsquicklytochangingheat
demands.
Intelligent use of DHW circulation pumps
AlwayscontrolDHWcirculationpumpsviatimeswitches.Programthese
inaccordancewithyourDHWdemandpatterns.
The optimum DHW temperature
Only ever set the DHW temperature or that of the cylinder to the
temperatureyoureallyrequire.Anyadditionalheatingusesadditional
energy.
Sensible handling of DHW
Showeringconsumesonlyapprox.1/3ofthewatervolumerequiredfor
abath.Repairanydrippingtapsimmediately.
DHW mode
Keep your operating instructions safe in an easily accessible place near your gas condensing boiler.
Faults / Fault codes Ifthe statusindicator ringashes red, where possible read the fault
codeontheconnectedcontrolunitaccessoryandnotethecode.The
appliancecanbereturnedintousebypressingtheresetbutton.Incase
of repeated faults, shut down the appliance and notify your heating
contractor.
Gas condensing boilers are equipped with an electronic ue gas
temperaturelimiter.Theapplianceautomaticallyshutsdownwhenthe
uegastemperatureexceeds110°C.Theboilerrestartswhenthereset
buttonispressed.Ifthisrecurs,askyourheatingcontractortocheck
theuesystem.
NB - risk of damage, poisoning and suffocation work less
effectively.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Wolf MGK-300 Operating Instructions Manual

Type
Operating Instructions Manual
This manual is also suitable for

Wolf MGK-300

Below you will find brief product information for Wolf MGK-300:

The Wolf MGK-300 is a gas condensing boiler that is part of a range of high-grade products that incorporate the latest safety technology, such as frost protection and balanced flue routing. It is suitable for installation in rooms that are free from the risk of frost, and comes with a 2-year warranty period and requires an annual service.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI